Resilient Solar PV Structures a.k.a. the "Nuts and Bolts" of PV Resilience

Solar photovoltaic (PV) systems can and has survived many extreme weather events. On occasion, however, solar PV systems have been damaged. This damage is related more to the features of individual PV systems rather than the magnitude of the weather events. Much of this damage can be avoided with relatively simple, cost-effective measures that include design, installation, inspection, and O&M best practices.

14 SOLAR ENERGY↗

Cybersecurity Assessment for a Behind-the-Meter Solar PV System: A Use Case for the DER-CF

The world's energy production is shifting toward lower-cost, cleaner, more efficient, and sustainable sources. The increasing numbers of distributed energy resources (DERs) are allowing for the rapid transformation of electric grids toward achieving the goal of energy decarbonization. Along with cleaner and more efficient energy, however, we must also aim for a secure energy future. Solar photovoltaic (PV) systems are an important part of this transition. This paper discusses a cybersecurity risk assessment for behind-the-meter DERs using a solar PV system as a use case of the Distributed Energy Resource Cybersecurity Framework (DER-CF) developed by the National Renewable Energy Laboratory. This poster presents a conference paper on the risk assessment processes and summarizes the DER-CF's use case recommendations to strengthen the cybersecurity posture of the electric grid.

cybersecurity↗

Solar PV and BESS Plant-Level Voltage Control and Interactions: Experiments and Analysis

In real world operation, low-frequency oscillations associated with plant-level voltage control of inverter-based resources (IBRs) have been a concern of grid operators. Here, this research aims to demonstrate and analyze the effect of plant-level voltage control on system stability and potential interactions among IBRs. The experiment results of a 13.2-kV system interconnected with two IBRs—a 1-MW battery energy storage system (BESS) and a 430-kW solar photovoltaic (PV) plant—are presented. Both 0.5-Hz and 3-Hz oscillations become visible at certain conditions. The phenomenon is further explained by use of a feedback system consisting of the plant-level droop control and the effect of reactive power or var injection on voltage. The main components of the block diagram are obtained via frequency scan measurements. The analysis offers an understanding of the main contributors and other influencing factors of the 3-Hz and 0.5-Hz modes. It also reveals the role of the volt-var droop gain, the low-pass filter time constant, and the system impedance in stability.

14 SOLAR ENERGY↗

International Applications for Floating Solar PV (FPV) [Slides]

Floating solar is a comparatively new concept. Floating solar is about to form a third pillar in the market for solar energy next to ground mounted and rooftop solar. The Asia-Pacific region already dominates the fast-emerging market in floating solar PV (FPV), and it looks set to build on that position as more nations get on board and costs fall. Asia-Pacific is set to increase its market share from 74% in 2020 to 87% in 2026 in terms of global installed FPV capacity. However, since floating solar systems are still a new application, there is a lack of information on its performance, cost, technical complexity, and operations and maintenance (O&M). This seminar series seeks to partially remedy that through presenting case studies that highlight the benefits, challenges, and applications of FPV in South and Southeast Asia.

14 SOLAR ENERGY↗

Solar PV on U.S. Houses of Worship: Overview of Market Activity and Trends [Slides]

Rooftop solar photovoltaic systems on houses of worship can provide unique community benefits and can raise local awareness and acceptance of solar energy. Recognizing that potential, a stakeholder team selected under DOE’s Solar Energy Innovation Network is working to develop a scalable model for recruiting and installing solar PV on houses of worship in underserved communities. Berkeley Lab is providing analytical support to this stakeholder team through several work products, including this report, which provides a data-oriented overview of market activity and trends related to solar PV installations on U.S. houses of worship (HoW). Drawing on Berkeley Lab’s project-level dataset of U.S. solar PV installations, the report describes: -market size and growth trends for PV on HoW -demographic characteristics of the communities in which HoW with PV are located, including income, race and ethnicity, and educational levels -key characteristics of the PV systems installed on HoW, including system size, installed costs, prevalence of third-party ownership, and pairing with storage -characteristics of the installer network servicing PV installations on HoW The purpose of the market overview is to inform business development and policy-making efforts aimed at supporting solar adoption by HoW.

14 SOLAR ENERGY↗

Community Center and Administration Solar PV Project

The Tribe installed two (2) roof mounted solar PV systems with a total production of approximately 146 kW on the Paskenta Band of Nomlaki Indians’ Community Center in Corning, CA. One of the two solar PV arrays provided 90% of the Community Center’s energy, while the second array provided nearly 100% of the adjacent administration building’s energy.

14 SOLAR ENERGY↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Fundamentals of Solar PV Bolted Joint Loosening and Prevention

The photovoltaic (PV) industry has long reported anecdotal accounts of systems exhibiting intermittent or chronic fastener loosening, including joints that fail to maintain preload despite multiple re-tightening attempts. These occurrences are frequently, and often incorrectly, attributed to installer errors, vibration, or loading beyond design expectations (e.g., extreme weather events). Loose fasteners have serious implications and can significantly impact solar PV systems’ performance, reliability, and safety. However, effective bolted joint design and proper assembly practices can mitigate or eliminate loosening. Until the US Department of Energy’s Solar Energy Technologies Office (SETO) funded research on fasteners and solar PV structures, there was a notable gap in understanding the causes of loosening in solar PV systems.

14 SOLAR ENERGY↗

Addressing the split incentive challenge for rooftop solar PV and battery energy storage in multifamily rental buildings (CRADA 638 Final Report)

This project advances the understanding of how roof solar PV systems and battery energy storage systems (BESS) can be effectively deployed in multifamily residential buildings, a sector that has historically faced barriers due to misaligned incentives between landlords and tenants. By leveraging high-resolution building stock data and simulation tools, the research demonstrates how energy consumption patterns vary across building types, climates, and occupant characteristics, and how these variations influence the optimal sizing and operation of distributed energy resources. A key contribution is the development of a publicly accessible, web-based tool named RESIDE (Residential Energy Systems & Infrastructure Data Evaluation) that allows users to explore building energy use and evaluate solar and battery configurations without requiring specialized expertise. This significantly lowers the barrier to entry for stakeholders such as property owners, utilities, and policymakers. From a technical perspective, the project shows that integrating rooftop solar PV with battery energy storage can substantially reduce electricity costs and peak demand through strategies such as energy arbitrage and peak shaving. The modeling framework incorporates real-world constraints, including time-of-use electricity pricing and battery degradation, providing realistic and actionable insights. Economically, the results indicate that properly sized systems can deliver meaningful cost savings, improving the feasibility of energy investments in multifamily housing. More broadly, the project benefits the public by supporting the transition to affordable and reliable energy, particularly in rental multifamily housing where adoption has traditionally lagged.

14 SOLAR ENERGY↗

Equity-driven Planning of Distributed Solar PV using Optimal Transport

Typically, distribution system planning processes do not explicitly incorporate energy equity considerations, such as identifying consumers most affected by energy costs and determining how investments in the distribution system can address existing energy burden imbalances. This paper proposes a novel optimal transport (OT)-based method to improve the energy burden distribution of consumers. The approach involves the strategic siting and sizing of solar PV in order to assist customers with high energy burden and improve the overall energy burden distribution of the community. The desired energy burden distribution is defined using the equal distribution equivalent (EDE) concept. The OT-based method is then used to estimate the distributed solar PV capacity to be installed at various locations and the tariffs to be adjusted, all while improving the energy burden distribution and providing valuable insights into distributed generation (DG) planning. The results on IEEE 37 bus test system demonstrate how DG planning, considering EDE and OT, can help reduce the energy burden of low-income consumers. Additionally, the approach also reveals optimal tariff adjustments needed to ensure revenue neutrality for distribution utilities.

Optimal transport, equal distribution equivalent, ↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Cost Benefit Analysis of Solar PV for the City of Oldsmar, FL

The City of Oldsmar is in the early stages of exploring renewable energy opportunities as a part of their initiative to reduce energy costs, improve backup power capacity, and begin the transition to more sustainable operations. The city is particularly interested in deploying a floating or ground-mounted solar PV system at its wastewater treatment plant. Currently, there are no solar PV installations in Oldsmar and there has been hesitancy to implement such a project due to the possible capital costs and limited technical capacity. Despite this the initiative has gained internal buy-in among staff working for the city. To assist with gaining more buy-in and making future decisions the city sought technical assistance (TA) from the Energy to Communities (E2C) Expert Match Program. Through the Expert Match Program, the city received TA provided by the Pacific Northwest National Lab (PNNL) to evaluate the cost effectiveness of several solar options. This report details the analysis and results of the work performed for TA.

14 SOLAR ENERGY↗

Maturing Rational Design Methodologies and Industry Consensus Engineering Standards: Critical Fastened Joints - Solar PV Industry

Critical structural joints can be seen throughout a solar array and are called upon to secure modules and keep racking assembled and able to resist large demands from winds and snow loads. In the relatively new and fast-growing solar PV industry, the important role these hardware assemblies (e.g. clips, clamps, bolts, nuts, washers) play is not well understood by product designers. Failures with critical structural joints are surprisingly common and point to the need for maturing the engineering and assembly of these joints. The wide variety of design concepts (Figure 2&2) demonstrate interesting and innovative ideas but are lacking the basics of fastener engineering seen in matured industries (e.g. transportation, buildings). Complicating the maturing process for critical structural joints is that they are one component in rack supporting structures that exhibits a systems behavior; each component will affect the other and play a key role in maintaining structural integrity. When wind loads the surface of a module, the underlying racking members deflect and twist which in turn imparts forces back into the joints and into the mounted modules. Often, these supporting rack structures exhibit high deflections and low natural frequencies which amplify the demands placed into the joints even in moderate winds. Current engineering practices and associated structural conventions view solar racking support structures as they would a high mass building that exhibit more static behaviors in wind events. Solar structures are unique from high mass buildings and require the development of solar specific industry engineering consensus standards.

14 SOLAR ENERGY↗

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

Building efficiency, electrification, and distributed solar PV bill savings under time-based retail rate designs

Building energy technologies and distributed generation, including energy efficiency (EE), distributed solar PV (DPV), and building electrification, are critical to meeting decarbonization goals. Rate design may play an important role in determining the customer economics of adopting these technologies, but it is unclear whether – and to what extent – current rate design trends support or impede progress toward these goals. In this study, we answer these questions by quantifying the range of residential customer bill impacts of EE, DPV, and building electrification investments under current and emerging time-based retail electricity rate designs (i.e., time-of-use, event-based pricing, coincident demand charges, and real time pricing). We also compare these customer bill savings to power system and societal benefits and assess how well the investments are compensated relative to the societal value they provide.

14 SOLAR ENERGY↗

U.S. Wind and Solar PV Supply Curves with Future Land-use Change

This dataset provides future supply curves representing the total resource potential for land-based wind and solar photovoltaic (PV) deployment in the conterminous United States after accounting for the impact of land-use and land-cover change (LULC). We use LULC projections from 2010 to 2050 developed based on the Intergovernmental Panel on Climate Change (IPCC) Special Report on Emission Scenarios. The LULC projections are subsequently fed into the renewable energy potential model (reV), which estimates total available wind and solar capacity after excluding non-developable land. Supply curves are provided for four IPCC scenarios in 2050: A1B, A2, B1, and B2. As a baseline, we also provide the supply curve from the B2 scenario in 2010. In addition to the supply curves, we also provide representative wind and solar generation profiles for each supply curve point. These generation profiles are provided as capacity factors and are based on a 2012 weather year using NSRDB and WindToolkit resource data. For more details on the supply curve and profile datasets included here please refer to README. Additional information on the supply curves and the LULC projections used to generate them, as well as an analysis of their impact on wind and solar deployment under decarbonization can be found in the publication linked below: "U.S. Wind and Solar PV Supply Curves with Future Land-use Change Publication".

Array↗

Optimizing Solar PV Deployment in Manufacturing: A Morphological Matrix and Fuzzy TOPSIS Approach

The growing energy demand of the industrial sector and the need for sustainable solutions highlight the importance of efficient decision making in solar photovoltaic (PV) implementation. Selecting optimal PV configuration is complex due to the interdependent technical, economic, environmental, and social factors involved. This study introduces an integrated decision-making method combining a morphological matrix and fuzzy TOPSIS to systematically select and rank optimal PV system configurations for manufacturing firms. While the morphological matrix exhaustively examines possible design solutions based on sensing, smart, sustainable, and social (S4) attributes, the fuzzy TOPSIS method ranks the alternatives by handling uncertainty in decision making. A case study conducted in a Mexican manufacturing company validates the methodology’s effectiveness. The optimal PV configuration identified comprehensively addresses operational and sustainability criteria, covering all lifecycle stages. This approach demonstrates quantitative superiority and greater robustness compared to existing fuzzy TOPSIS-based methods for solar PV applications. The findings highlight the practical value of data-driven, multi-criteria decision making for industrial solar energy adoption, enhancing project feasibility, cost efficiency, and environmental compliance. Future research will incorporate discrete event simulation (DES) to further refine energy consumption strategies in manufacturing.

Briceño, Citlaly Pérez↗