Cb-1zr Pumped Sodium Loop
Cb-1Zr pumped sodium loop tests to evaluate loop components, EM pump, pressure transducers, and instrumentation techniques
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Cb-1Zr pumped sodium loop tests to evaluate loop components, EM pump, pressure transducers, and instrumentation techniques
To support operations in the HFEF Hot Cell and the FCF Hot Cell, multiple components were designed to support the Bottle Cutter Project and the Sodium Loop Project. These components were designed and analyzed to ensure they can function in their environment and be operated remotely. FEA analysis were performed, prototypes were made, and parts were manufactured to complete this project. This poster documents these parts and test results.
This report documents sodium chemistry characterization and the initiation of forced‑convection sodium exposure experiments for two structural materials for sodium‑cooled fast reactors (SFRs): Alloy 709 (solution‑annealed and with an additional 775 °C/10 h precipitation treatment) and laser powder bed fusion (LPBF) 316H stainless steel tensile specimens printed with an as‑built surface condition. The sodium exposure experiment was conducted in a forced‑convection sodium loop with two vessels operated at 550 °C and 600 °C, and a cold trap maintained at <130 °C. Carbon activity in sodium was quantified using a nickel‑foil equilibration method. Initial post‑exposure evaluation after ~1,000 h indicates negligible thickness change for Alloy 709 and a small but measurable mass decrease. To isolate thermal effects from sodium effects, parallel thermal‑aging experiments were performed on Alloy 709 at 550 °C and 600 °C. Baseline tensile tests at room temperature, 550 °C, and 600 °C show expected reduction in strength with increasing temperature and serration tensile curves at elevated temperatures, consistent with dynamic strain aging. After 3,000 h thermal aging, Alloy 709 exhibits modest strengthening and reduced ductility at 550 °C. Together, these results establish the loop chemistry conditions and provide the initial corrosion and mechanical property results for ongoing long‑duration sodium exposure of Alloy 709 and LPBF 316H stainless steel.
Design, fabrication and testing of Cb-1Zr thermal convection loop for evaluation of refractory metals in boiling and condensing potassium environments
SNAP 8 simulator using primary sodium-potassium loop, mercury loop operating on Rankine cycle, and heat rejection sodium-potassium loop
Eutectic sodium potassium and OS-124 considered as coolant fluids for SNAP-8 third loop - optimum loop operating parameters
Alkali metal heat transfer technology was used in the development of conceptual designs for the transport and storage of sensible and latent heat thermal energy in distributed concentrator, solar Stirling power conversion systems at a power level of 15 kWe per unit. Both liquid metal pumped loop and heat pipe thermal transport were considered; system configurations included: (1) an integrated, focal mounted sodium heat pipe solar receiver (HPSR) with latent heat thermal energy storage; (2) a liquid sodium pumped loop with the latent heat storage, Stirling engine-generator, pump and valves located on the back side of the concentrator; and (3) similar pumped loops serving several concentrators with more centralized power conversion and storage. The focus mounted HPSR was most efficient, lightest and lowest in estimated cost. Design confirmation testing indicated satisfactory performance at all angles of inclination of the primary heat pipes to be used in the solar receiver.
Corrosion test loop, and purification, analysis, and handling of sodium and potassium
A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.
Performance tests on liquid metal pumps for sodium potassium loops
The design feasibility study is documented of a single cylinder, free piston Stirling engine/linear alternator (FPSE/LA) power module generating 150 kW-electric (kW sub e), and the determination of the module's maximum feasible power level. The power module configuration was specified to be a single cylinder (single piston, single displacer) FPSE/LA, with tuning capacitors if required. The design requirements were as follows: (1) Maximum electrical power output; (2) Power module thermal efficiency equal to or greater than 20 percent at a specific mass of 5 to 8 kg/kW(sub e); (3) Heater wall temperature/cooler wall temperature = 1050 K/525 K; (4) Sodium heat-pipe heat transport system, pumped loop NaK (sodium-potassium eutectic mixture) rejection system; (5) Maximum power module vibration amplitude = 0.0038 cm; and (6) Design life = 7 years (60,000 hr). The results show that a single cylinder FPSE/LA is capable of meeting program goals and has attractive scaling attributes over the power range from 25 to 150 kW(sub e). Scaling beyond the 150 kW(sub e) power level, the power module efficiency falls and the power module specific mass reaches 10 kg/kW(sub e) at a power output of 500 kW(sub e). A discussion of scaling rules for the engine, alternator, and heat transport systems is presented, along with a detailed description of the conceptual design of a 150 kW(sub e) power module that meets the requirements. Included is a discussion of the design of a dynamic balance system. A parametric study of power module performance conducted over the power output range of 25 to 150 kW(sub e) for temperature ratios of 1.7, 2.0, 2.5, and 3.0 is presented and discussed. The results show that as the temperature ratio decreases, the efficiency falls and specific mass increases. At a temperature ratio of 1.7, the 150 kW(sub e) power module cannot satisfy both efficiency and specific mass goals. As the power level increases from 25 to 150 kW(sub e) at a fixed temperature ratio, power module efficiency is seen to increase slightly, but at the expense of increased specific mass. An empirical equation relating power module thermal efficiency as a function of power module specific mass, power output, and temperature ratio is developed. Alternative configurations to the single cylinder, direct coupled linear alternator approach are also evaluated, but are shown to have technical drawbacks that lessen their attractiveness. The dynamic balance assembly mass (moving mass and structure) represents 20 to 30 percent of the total single cylinder power module mass. Joining two modules in a balanced opposed configuration eliminates the need for the balancer, and a hot end junction can be made without significant addition of structural mass. Recommendations are made for evaluation of advanced heat pipe concepts, tests of radial flow heat exchangers, and evaluation of high temperature alternator materials.
Self-seeking liquid sodium level and sodium impurity measurements for fast reactor test loop
Heat transfer to auxiliary sodium coolant radiator loop of space power reactor
Free-piston Stirling power conversion has been identified as a viable option for potential Fission Surface Power (FSP) systems on the Moon and Mars. Proposed systems consist of two or more Stirling convertors, in a dual-opposed configuration, coupled to a low-temperature uranium-dioxide-fueled, liquid-metal-cooled reactor. To reduce developmental risks associated with liquid-metal loop integration, a test rig has been built to evaluate the performance of a pair of 1-kW free-piston Stirling convertors using a pumped sodium-potassium (NaK) loop for thermal energy input. Baseline performance maps have been generated at the Glenn Research Center (GRC) for these 1-kW convertors operating with an electric heat source. Each convertor was then retrofitted with a custom-made NaK heater head and integrated into a pumped NaK system at the Marshall Space Flight Center (MSFC). This paper documents baseline testing at GRC as well as the progress made in integrating the Stirling convertors into the pumped NaK loop.
Mechanistic assessments of radionuclide release during postulated accidents are expected to be included in advanced reactor license applications. The mechanistic source term (MST) provides an opportunity for vendors to realistically evaluate the radiological consequences of an incident, and may aid in justifying reduced emergency planning zones and plant sites. However, the development of MSTs for advanced nuclear reactors is challenging because there are numerous phenomena that can affect the transport and retention of radionuclides. As part of a trial MST assessment for a metal-fueled, pool-type sodium cooled fast reactor (SFR), led by Argonne National Laboratory, a simplified radionuclide transport code (SRT code) was developed, which includes models to estimate the quantity of fission product aerosols scrubbed in the sodium pool during postulated accident scenarios. In a pool-type SFR, when fission products are released into the coolant pool due to failure of fuel pins, most of the radionuclides are scrubbed by the coolant pool, but some have the potential to migrate to the cover gas region through entrainment within gas bubbles. The SRT code contains a model that evaluates this scrubbing behavior and calculates the fraction of fission product aerosols that reach the cover gas. Due to a lack of available validation data for sodium pool scrubbing, the U.S. Department of Energy funded an experiment at the University of Wisconsin-Madison to measure aerosol scrubbing by injecting air bubbles containing aerosol into a coolant pool. Prior to performing an experiment with liquid sodium, a water loop experiment was performed. Their experiment evaluated the effect of changing the aerosol size, aerosol density, aerosol concentration, bubble size, and pool depth on the aerosol scrubbing efficiency of the pool. In this benchmark experiment, the base tests were conducted by repeated tests of isolated bubbles. Afterwards, more prototypic tests with bubble swarms were performed to evaluate the interactions between the bubbles. The bubble swarm test was able to confirm that a larger amount of aerosol scrubbing occurred than the single bubble test. It was also confirmed that as the bubble size, aerosol density, and pool height increase, the extent of pool scrubbing also increases and does not change with the aerosol concentration. In addition, since the degree of scrubbing is the lowest at aerosol sizes between 0.01 and 1 μm, that is, the largest amount of aerosol is emitted, it was confirmed that the analysis of this size in MST is the most important. This benchmark experiment informs the direction of future sodium experiments.
The work function determinations of candidate materials for low temperature (1400 K) thermionics through vacuum emission tests are discussed. Two systems, a vacuum emission test vehicle and a thermionic emission microscope are used for emission measurements. Some nickel and cobalt based super alloys were preliminarily examined. High temperature physical properties and corrosion behavior of some super alloy candidates are presented. The corrosion behavior of sodium is of particular interest since topping cycles might use sodium heat transfer loops. A Marchuk tube was designed for plasma discharge studies with the carbide and possibly some super alloy samples. A series of metal carbides and other alloys were fabricated and tested in a special high temperature mass spectrometer. This information coupled with work function determinations was evaluated in an attempt to learn how electron bonding occurs in transition alloys.
Several methods for coupling the SP-100 space nuclear reactor to the NASA Lewis Research Center's Free Piston Stirling Power Convertor (FPSPC) are presented. A 25 kWe, dual opposed Stirling convertor configuration is used in these designs. The concepts use radiative coupling between the SP-100 lithium loop and the sodium heat pipe of the Stirling convertor to transfer the heat from the reactor to the convertor. Four separate configurations are presented. Masses for the four designs vary from 41 to 176 kgs. Each design's structure, heat transfer characteristics, and heat pipe performance are analytically modeled.
The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodium-potassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated cold-end fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to high-cost composite radiators in an end-to-end TDU test.