Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SnCl4”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Radiolytic preparation of anhydrous tin (2) chloride

Anhydrous tin (2) chloride (SnCl2) is prepared by radiolysis with high energy electrons of a tin (4) chloride (SnCl4) solution in heptane. The SnCl4 is reduced to insoluble SNCl2. The energy yield, G(SnCl2), molecules of SnCl2, produced per 100 eV, increases with SnCl4 concentration from 1.6 at 0.15 M SnCl4 to 3.1 at 3.0 M SnCl4. Other parameters such as temperature total dose and beam current have little influence on G(SnCl2). The method may be used to prepare other metal halides if the higher valence, more covalent metal halide is soluble in aliphatic hydrocarbons and the lower more ionic metal halide is insoluble. The reaction mechanism is discussed; the radiolysis of both heptane and SnCl4 is involved. At high SnCl4 concentration G(SnCl2) appears to be limited by the yield of SnC13 radicals.

Philipp, W. H.↗

An ultra-sensitive coherent detector capable of single photon detection for lidar applications

The properties of Ultra-Sensitive Coherent Detectors (USCD's) are nearly that of an ideal detector for lidar applications. Recent progress in the development of USCD's is briefly reviewed, and its imaging capability is demonstrated. These new detectors possess properties with significant improvements over conventional technology. These improvements include a high quantum efficiency of 0.95, gain in excess of 10 exp 13, a narrow bandwidth of 180-300 MHz at 1 micron, imaging capability, and phase conjugation ability. We have constructed a USCD using two Nd:YAG laser amplifiers and a four-wave Brillouin mirror (FWBM) using SnCl4 as the Brillouin medium. Using a 10 Hz repetitively-pulsed single frequency laser, we have shown that the Brillouin medium is free from thermal blooming and from optical breakdown.

Amimoto, Sherwin↗

Electrically conducting polyimide film containing tin complexes

Disclosed is a thermally-stable SnO2-surfaced polyimide film wherein the electrical conductivity of the SnO2 surface is within the range of about 3.0 x 10(exp -3) to about 1 x 10(exp -2) ohms(exp -1). Also disclosed is a method of preparing this film from a solution containing a polyamic acid and SnCl4 (DMSO)2.

St.clair, Anne K.↗

Intermediate Temperature Fluids Life Tests - Experiments

There are a number of different applications that could use heat pipes or loop heat pipes (LHPs) in the intermediate temperature range of 450 to 725 K (170 to 450 C), including space nuclear power system radiators, fuel cells, and high temperature electronics cooling. Historically, water has been used in heat pipes at temperatures up to about 425 K (150 C). Recent life tests, updated below, demonstrate that titanium/water and Monel/water heat pipes can be used at temperatures up to 550 K (277 C), due to water's favorable transport properties. At temperatures above roughly 570 K (300 C), water is no longer a suitable fluid, due to high vapor pressure and low surface tension as the critical point is approached. At higher temperatures, another working fluid/envelope combination is required, either an organic or halide working fluid. An electromotive force method was used to predict the compatibility of halide working fluids with envelope materials. This procedure was used to reject aluminum and aluminum alloys as envelope materials, due to their high decomposition potential. Titanium and three corrosion resistant superalloys were chosen as envelope materials. Life tests were conducted with these envelopes and six different working fluids: AlBr3, GaCl3, SnCl4, TiCl4, TiBr4, and eutectic diphenyl/diphenyl oxide (Therminol VP-1/Dowtherm A). All of the life tests except for the GaCl3 are ongoing; the GaCl3 was incompatible. As the temperature approaches 725 K (450 C), cesium is a potential heat pipe working fluid. Life tests results are also presented for cesium/Monel 400 and cesium/70-30 copper/nickel heat pipes operating near 750 K (477 C). These materials are not suitable for long term operation, due to copper transport from the condenser to the evaporator.

Anderson, William G.↗