Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Small pixel effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gamma-ray Spectra from a 3x3 CsPbBr 3 Array

CsPbBr 3 is a promising semiconductor material for X- and γ-ray detection at room temperature due to a wide bandgap of 2.3eV, high stopping power, and relatively high mobility-lifetime products of electrons and holes, and the capability of growing large crystals. In this paper we report on fabrication and testing of a 3.8 mm thick, 3 X 3 array with 1.2 mm pitch. Raw 137 Cs spectra were acquired with applied bias of 400 V, 500 V, and 600 V. Energy resolution of between 2 and 3 % FWHM at 662 keV was obtained from most pixels without any correction at room temperature. After 15 days under continuous bias at 600 V, no polarization effects were observed.

36 MATERIALS SCIENCE↗

Deep-learning-based workflow for boundary and small target segmentation in digital rock images using UNet++ and IK-EBM

We report three-dimensional (3D) X-ray micro-computed tomography (μCT) has been widely used in petroleum engineering because it can provide detailed pore structural information for a reservoir rock, which can be imported into a pore-scale numerical model to simulate the transport and distribution of multiple fluids in the pore space. The partial volume blurring (PVB) problem is a major challenge in segmenting raw μCT images of rock samples, which impacts boundaries and small targets near the resolution limit. We developed a deep-learning (DL)-based workflow for accurate and fast partial volume segmentation. The DL model's performance depends primarily on the training data quality and model architecture. This study employed the entropy-based-masking indicator kriging (IK-EBM) to segment 3D Berea sandstone images as training datasets. The comparison between IK-EBM and manual segmentation using a 3D synthetic sphere pack, which had a known ground truth, showed that IK-EBM had higher accuracy on partial volume segmentation. We then trained and tested the UNet++ model, a state-of-the-art supervised encoder-decoder model, for binary (i.e., void and solid) and four-class segmentation. We compared the UNet++ with the commonly used U-Net and wide U-Net models and showed that the UNet++ had the best performance in terms of pixel-wise and physics-based evaluation metrics. Specifically, boundary-scaled accuracy demonstrated that the UNet++ architecture outperformed the regular U-Net architecture in the segmentation of pixels near boundaries and small targets, which were subjected to the PVB effect. Feature map visualization illustrated that the UNet++ bridged the semantic gaps between the feature maps extracted at different depths of the network, thereby enabling faster convergence and more accurate extraction of fine-scale features. The developed workflow significantly enhances the performance of supervised encoder-decoder models in partial volume segmentation, which has extensive applications in fundamental studies of subsurface energy, water, and environmental systems.

02 PETROLEUM↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TinyTPC: A Test Stand for LAr Doping

LArTPCs are widely used in neutrino experiments at the GeV scale. They measure the charge and light produced by interactions between charged particles and argon atoms. While charge is collected efficiently, light is not. TinyTPC is a small scale LArTPC with a pixelated readout for R&D with photosensitive dopants, which convert light into charge. TinyTPC studies the effects of adding photosensitive dopants and xenon to liquid argon to enhance charge signals of events in the MeV scale.

Rodriguez Thorne, Paloma↗

Quantifying Operational Drivers of Multimodal Biometric Verification in Aerial Surveillance

Multimodal biometric verification is increasingly applied across operational contexts ranging from close-range security cameras and building-mounted surveillance to long-range ground sensors and unmanned aerial system (UAS) imagery. Variations in acquisition conditions—such as image resolution, viewing geometry, and motion artifacts—pose significant challenges for cross-domain algorithmic generalization. This study evaluates two independent multimodal biometric verification systems developed under the Intelligence Advanced Research Projects Activity (IARPA) Biometric Recognition and Identification at Altitude and Range (BRIAR) program, comparing performance on close-range and aerial datasets. Close-range video served as a baseline to quantify the decline in verification performance on aerial footage. The dataset included six UAS platforms, spanning small quadcopters at 10m altitude to medium-sized fixed-wing aircraft at 360m. Mixed-effects logistic regression identified image resolution (head and body pixel counts), head height, sensor characteristics, and algorithm selection as primary determinants of verification success, whereas demographic attributes and mission gait were not significant predictors. Activity type and collection site influenced performance in close-range data but had negligible impact on UAS imagery. These results clarify modality-specific strengths and limitations and highlight opportunities to enhance cross-domain biometric verification.

Peluso, Alina [ORNL] (ORCID:0000000328950406)↗

Photometry, Centroid and Point-spread Function Measurements in the LSST Camera Focal Plane Using Artificial Stars

Abstract The Vera C. Rubin Observatory’s LSST Camera (LSSTCam) pixel response has been characterized using laboratory measurements with a grid of artificial stars. We quantify the contributions to photometry, centroid, point-spread function size, and shape measurement errors due to small anomalies in the LSSTCam CCDs. The main sources of those anomalies are quantum efficiency variations and pixel area variations induced by the amplifier segmentation boundaries and “tree-rings”—circular variations in silicon doping concentration. This laboratory study using artificial stars projected on the sensors shows overall small effects. The residual effects on point-spread function (PSF) size and shape are below 0.1%, meeting the ten-year LSST survey science requirements. However, the CCD mid-line presents distortions that can have a moderate impact on PSF measurements. This feature can be avoided by masking the affected regions. Effects of tree-rings are observed on centroids and PSFs of the artificial stars and the nature of the effect is confirmed by a study of the flat-field response. Nevertheless, further studies of the full-focal plane with stellar data should more completely probe variations and might reveal new features, e.g., wavelength-dependent effects. The results of this study can be used as a guide for the on-sky operation of LSSTCam.

79 ASTRONOMY AND ASTROPHYSICS↗

The CMOS Pseudo-Thyristor: a zero-static current discriminator circuit

We report a very low power discriminator circuit for pixelized detectors, called the Pseudo-Thyristor is described in this document. It is a positive feedback topology using regular PMOS and NMOS field-effect transistors (FET's) with zero static current. When a small charge is injected into the circuit, it flips rapidly due to the positive feedback and outputs a logic transition for further digitization. Simulation shows that in a 65 nm process, it is possible to achieve a detecting threshold below 5 fC while maintain the average power consumption below 10 micro-Watts when the hit occupancy is <10% for 40 MHz operation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Image Distinguishability Analysis Testing Through Principal Components and Its Application to Hot Spot Scale Invariance

Hot spots are spatial regions of intense energy localization that govern initiation of secondary high explosives. Studies that characterize or compare simulated hot spots are frequently either qualitatively descriptive or resort to quantitative distribution functions that neglect stochastic variations and spatial correlations—effects that are also neglected in common comparison tests like the Kolmogorov–Smirnov test. To this end, we develop an image distinguishability analysis (IDA) test based on principal component (PC) analysis that makes pixel-by-pixel comparisons between small, for example, O(<10), image data sets. The IDA test makes comparisons through a generalized distance metric in the PC space and a test statistic that is derived to calculate mathematical equation-values. Here, we derive a statistical distribution and criticality criterion to determine whether images are distinguishable from established baselines. We apply the IDA test on images generated from molecular dynamics simulations of hot spots from pore collapse in TATB to assess scale invariance in the complex patterns of hot spots that form in a representative high explosive crystal. The IDA test shows that TATB hot spot spatial temperature fields and their derived temperature histograms exhibit scale-invariant features over specific intervals of shock orientation, strength, and initial pore diameter. However, the IDA test also shows that qualitatively different conclusions regarding invariance can be reached depending on whether the hot spot is treated as a spatially correlated field as opposed to a distribution function that lacks spatial information.

organic↗

Photon noise correlations in millimeter-wave telescopes

Many modern millimeter and submillimeter (“mm-wave”) telescopes for astronomy are deploying more detectors by increasing the detector pixel density and, with the rise of lithographed detector architectures and high-throughput readout techniques, it is becoming increasingly practical to overfill the focal plane. However, when the pixel pitch p pix is small compared to the product of the wavelength λ and the focal ratio F , or p pix ≲1.2 F λ , the Bose term of the photon noise correlates between neighboring detector pixels due to the Hanbury Brown and Twiss (HBT) effect. When this HBT effect is non-negligible, the array-averaged sensitivity scales with the detector count N det less favorably than the uncorrelated limit of N det −1/2 . In this paper, we present a general prescription to calculate this HBT correlation based on a quantum optics formalism and extend it to polarization-sensitive detectors. We then estimate the impact of HBT correlations on the sensitivity of a model mm-wave telescope and discuss the implications for a focal plane design.

Hill, Charles A. (ORCID:0000000226416878)↗

Calibration of the IXPE Focal Plane X-Ray Polarimeters to Polarized Radiation

The Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission—in partnership with the Italian Space Agency—dedicated to X-ray polarimetry in the 2–8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector, a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units at INAF-IAPS, in Italy, where a dedicated facility was setup at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.

79 ASTRONOMY AND ASTROPHYSICS↗

Remote Sensing Low Signal-to-Noise-Ratio Target Detection Enhancement

In real-time remote sensing application, frames of data are continuously flowing into the processing system. The capability of detecting objects of interest and tracking them as they move is crucial to many critical surveillance and monitoring missions. Detecting small objects using remote sensors is an ongoing, challenging problem. Since object(s) are located far away from the sensor, the target’s Signal-to-Noise-Ratio (SNR) is low. The Limit of Detection (LOD) for remote sensors is bounded by what is observable on each image frame. In this paper, we present a new method, a “Multi-frame Moving Object Detection System (MMODS)”, to detect small, low SNR objects that are beyond what a human can observe in a single video frame. This is demonstrated by using simulated data where our technology-detected objects are as small as one pixel with a targeted SNR, close to 1:1. We also demonstrate a similar improvement using live data collected with a remote camera. The MMODS technology fills a major technology gap in remote sensing surveillance applications for small target detection. Our method does not require prior knowledge about the environment, pre-labeled targets, or training data to effectively detect and track slow- and fast-moving targets, regardless of the size or the distance.

47 OTHER INSTRUMENTATION↗

A new paradigm in electron microscopy: Automated microstructure analysis utilizing a dynamic segmentation convolutional neutral network

Over the past half century, the transmission electron microscope enabled insight into the fundamental arrangements and structures of materials. State-of-the-art electron microscopes can acquire large image datasets across multiple imaging modalities. However, the manual annotation process for feature or defect quantification may not be feasible with the modern microscope. Convolutional neural networks emerged to characterize individual microstructural features from an image in a cost-effective, consistent manner. However, many of these neural network approaches rely on thousands to hundreds of thousands of manual annotations of each feature type across hundreds of images to train the network for adequate performance. This work focused on the development and application of a pixel-wise defect detection machine-learning dynamic segmentation convolutional neural network with associated automated acquisition and postprocessing to identify microstructural features rapidly and quantitatively from a small initial dataset incorporating multiple imaging modes. The approach was demonstrated for characterization of superalloy 718 from both single image acquisition on multiple detectors to in-situ evolution captured with a single detector on a standard desktop computer to demonstrate the low barrier to entry required for widespread adoption. Pixel-by-pixel class identification was excellent with strong identification of chemically distinct phases, structurally distinct phases, and defect structures, thus demonstrating the new paradigm of machine learning-assisted characterization.

36 MATERIALS SCIENCE↗

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE↗

Understanding Formation of Irradiation-Induced Defects through 4D-STEM, Electron Tomography, and WBDF-STEM

A major challenge in advancing nuclear materials for next-generation fission and proposed fusion reactors is to comprehensively understand the formation of irradiation-induced defects. Here it is essential to correlate the evolution of irradiation-induced defects and the degradation of mechanical properties, as they collectively dictate the material's lifespan and ensure nuclear safety. Scanning transmission electron microscopy (STEM) based techniques have emerged as indispensable tools for irradiation-induced defect characterization, offering high spatial resolution imaging and chemical analysis, such as electron energy loss spectroscopy (EELS) and energy dispersive X-ray spectroscopy (EDXS). These techniques have been effectively used to obtain an atomic-scale view of the defect structure. Recent advances in electron microscopy, particularly in 4D-STEM, offer detailed insight into microstructural evolution by capturing full 2D diffraction patterns at every pixel position. Using high-speed direct electron detectors, this technology generates a four-dimensional dataset, overcoming the limitations of traditional STEM imaging.

36 MATERIALS SCIENCE↗

Evaluation of Electron Tomography Capabilities for Shale Imaging

Despite the advantageous resolution of electron tomography (ET), reconstruction of three-dimensional (3D) images from multiple two-dimensional (2D) projections presents several challenges, including small signal-to-noise ratios, and a limited projection range. This study evaluates the capabilities of ET for thin sections of shale, a complex nanoporous medium. A numerical phantom with 1.24 nm pixel size is constructed based on the tomographic reconstruction of a Barnett shale. A dataset of 2D projection images is numerically generated from the 3D phantom and studied over a range of conditions. First, common reconstruction techniques are used to reconstruct the shale structure. The reconstruction uncertainty is quantified by comparing overall values of storage and transport metrics, as well as the misclassification of pore voxels compared to the phantom. We then select the most robust reconstruction technique and we vary the acquisition conditions to quantify the effect of artifacts. We find a strong agreement for large pores over the different acquisition workflows, while a wider variability exists for nanometer-scale features. Furthermore, the limited projection range and reconstruction are identified as the main experimental bottlenecks, thereby suggesting that sample thinning, advanced holders, and advanced reconstruction algorithms offer opportunities for improvement.

3D scanning transmission electron microscopy↗

Simulating image coaddition with the Nancy Grace Roman Space Telescope – II. Analysis of the simulated images and implications for weak lensing

One challenge for applying current weak lensing analysis tools to the Nancy Grace Roman Space Telescope is that individual images will be undersampled. Our companion paper presented an initial application of Imcom – an algorithm that builds an optimal mapping from input to output pixels to reconstruct a fully sampled combined image – on the Roman image simulations. In this paper, we measure the output noise power spectra, identify the sources of the major features in the power spectra, and show that simple analytic models that ignore sampling effects underestimate the power spectra of the coadded noise images. We compute the moments of both idealized injected stars and fully simulated stars in the coadded images, and their one- and two-point statistics. We show that the idealized injected stars have root-mean-square ellipticity errors (1–6) × 10 -4 per component depending on the band; the correlation functions are ≥2 orders of magnitude below requirements, indicating that the image combination step itself is using a small fraction of the overall Roman second moment error budget, although the fourth moments are larger and warrant further investigation. The stars in the simulated sky images, which include blending and chromaticity effects, have correlation functions near the requirement level (and below the requirement level in a wide-band image constructed by stacking all four filters). We evaluate the noise-induced biases in the ellipticities of injected stars, and explain the resulting trends with an analytical model. We conclude by enumerating the next steps in developing an image coaddition pipeline for Roman.

79 ASTRONOMY AND ASTROPHYSICS↗

INR-TEM: Robust cavity detection in multifocus TEM images via implicit neural representations

When characterizing materials using transmission electron microscopy (TEM) images, detecting and quantifying small features in microstructures, such as cavities, pose significant challenges. Off-the-shelf object detection models, including YOLOv8, show considerable performance degradation, particularly when images vary in resolution and the objects of interest possess a low percentage of the total image region of interest. In this study, we introduce a novel detection pipeline that incorporates an implicit neural representation (INR)-based detection method, INR-TEM, and two-modality imaging (e.g., under-focused and over-focused images typically acquired during materials characterization) to improve object detection performance. The INR-TEM method incorporates a pixel-wise prediction principle inspired by pixel-wise centerness weighting. INR-TEM demonstrates superior robustness to resolution variability, maintaining high detection accuracy even at low image resolutions compared to YOLOv8. To leverage INR-TEM effectively in real-world two-modality characterization applications, we further integrate a two-stage motion correction pipeline designed explicitly for aligning multifocus TEM images. The alignment process, comprising keypoint (based on scale-invariant feature transform, SIFT) and intensity matching, significantly mitigates the adverse effects of perceived motion-induced image degradation during through-focal TEM imaging, directly enhancing INR-TEM’s detection capability over conventional single-focus images. Our integrated INR-TEM cavity detection framework notably improves performance across various cavity sizes, outperforming off-the-shelf YOLOv8 detections that rely on a single image modality.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Snowmass2021 CMB-HD White Paper

CMB-HD is a proposed millimeter-wave survey over half the sky that would be ultra-deep (0.5 uK-arcmin) and have unprecedented resolution (15 arcseconds at 150 GHz). Such a survey would answer many outstanding questions about the fundamental physics of the Universe. Major advances would be 1.) the use of gravitational lensing of the primordial microwave background to map the distribution of matter on small scales (k~10 h Mpc^(-1)), which probes dark matter particle properties. It will also allow 2.) measurements of the thermal and kinetic Sunyaev-Zel'dovich effects on small scales to map the gas density and velocity, another probe of cosmic structure. In addition, CMB-HD would allow us to cross critical thresholds: 3.) ruling out or detecting any new, light (< 0.1 eV) particles that were in thermal equilibrium with known particles in the early Universe, 4.) testing a wide class of multi-field models that could explain an epoch of inflation in the early Universe, and 5.) ruling out or detecting inflationary magnetic fields. CMB-HD would also provide world-leading constraints on 6.) axion-like particles, 7.) cosmic birefringence, 8.) the sum of the neutrino masses, and 9.) the dark energy equation of state. The CMB-HD survey would be delivered in 7.5 years of observing 20,000 square degrees of sky, using two new 30-meter-class off-axis crossed Dragone telescopes to be located at Cerro Toco in the Atacama Desert. Each telescope would field 800,000 detectors (200,000 pixels), for a total of 1.6 million detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗