At least 19 records

Validation of Procedures for Monitoring Crewmember Immune Function SDBI-1900, SMO-015 - Integrated Immune

There is ample evidence to suggest that space flight leads to immune system dysregulation. This may be a result of microgravity, confinement, physiological stress, radiation, environment or other mission-associated factors. The clinical risk from prolonged immune dysregulation during space flight are not yet determined, but may include increased incidence of infection, allergy, hypersensitivity, hematological malignancy or altered wound healing. Each of the clinical events resulting from immune dysfunction has the potential to impact mission critical objectives during exploration-class missions. To date, precious little in-flight immune data has been generated to assess this phenomenon. The majority of recent flight immune studies have been post-flight assessments, which may not accurately reflect the in-flight condition. There are no procedures currently in place to monitor immune function or its effect on crew health. The objective of this Supplemental Medical Objective (SMO) is to develop and validate an immune monitoring strategy consistent with operational flight requirements and constraints. This SMO will assess the clinical risks resulting from the adverse effects of space flight on the human immune system and will validate a flight-compatible immune monitoring strategy. Characterization of the clinical risk and the development of a monitoring strategy are necessary prerequisite activities prior to validating countermeasures. This study will determine, to the best level allowed by current technology, the in-flight status of crewmembers immune system. Pre-flight, in-flight and post-flight assessments of immune status, immune function, viral reactivation and physiological stress will be performed. The in-flight samples will allow a distinction between legitimate in-flight alterations and the physiological stresses of landing and readaptation which are believed to alter landing day assessments. The overall status of the immune system during flight (activation, deficiency, dysregulation) and the response of the immune system to specific latent virus reactivation (known to occur during space flight) will be thoroughly assessed. Following completion of the SMO the data will be evaluated to determine the optimal set of assays for routine monitoring of crewmember immune system function, should the clinical risk warrant such monitoring.

Crucian, Brian↗

Nutritional Status Assessment (SMO 016E)

It has not been possible to assess nutritional status of crew members on the ISS during flight because blood and urine could not be collected during ISS missions. Postflight observations of alterations in nutritional status for several nutrients are troubling, and we require the ability to monitor the status of these nutrients during flight to determine if there is a specific impetus or timeframe for these changes. In addition to the monitoring of crew nutritional status during flight, in-flight sample collection would allow better assessment of countermeasure effectiveness. SMO 016E is also designed to expand the current medical requirement for nutritional assessment (MR016L) to include additional normative markers for assessing crew health and countermeasure effectiveness. Additional markers of bone metabolism will be measured to better monitor bone health and the effectiveness of countermeasures to prevent bone resorption. New markers of oxidative damage will be measured to better assess the type of oxidative insults that occur during space flight. The array of nutritional assessment parameters will be expanded to include parameters that will allow us to better understand changes in folate and vitamin B6 status, and related cardiovascular risk factors during and after flight. Additionally, stress hormones and hormones that affect bone and muscle metabolism will also be measured. This additional assessment will allow us to better monitor the health of crew members and make more accurate recommendations for their rehabilitation. Several nutritional assessment parameters are altered at landing, but it is not known how long these changes persist. We extended the current protocol to include an additional postflight blood and urine sample collection 30 days after landing. Data are being collected before, during, and after flight. These data will provide a complete survey of how nutritional status and related systems are affected by space flight. Analyzing the data will help us to define nutritional requirements for long-duration missions. This expanded set of measurements will also aid in the identification of nutritional countermeasures to counteract, for example, the deleterious effects of microgravity on bone and muscle and the effects of space radiation.

Smith, S. M.↗

Nutritional Status Assessment (SMO 016E)

Until 2006, it was not been possible to assess nutritional status of crewmembers on the ISS during flight because blood and urine could not be collected during ISS missions. Postflight observations of alterations in status of several nutrients are troubling, and we require the ability to monitor the status of these nutrients during flight to determine if there is a specific impetus or timeframe for these changes. In addition to the monitoring of crew nutritional status during flight, in-flight sample collection would allow better assessment of countermeasure effectiveness. Collecting samples during flight is one of the objectives of SMO 016E, and it is also designed to expand the current medical requirement for nutritional assessment (MR016L) to include additional normative markers for assessing crew health and countermeasure effectiveness. Additional markers of bone metabolism will be measured to better monitor bone health and the effectiveness of countermeasures to prevent bone resorption. New markers of oxidative damage will be measured to better assess the type of oxidative insults that occur during space flight. The array of nutritional assessment variables will be expanded to include ones that will allow us to better understand changes in folate, vitamin K, and vitamin B6 status, as well as risk factors for cardiovascular and oxidative damage during and after flight. Stress hormones and hormones that affect bone and muscle metabolism will also be measured. Measuring these additional variables will allow us to better monitor the health of crewmembers and make more accurate recommendations for their rehabilitation. Several nutritional assessment variables are altered at landing, but it is not known how long these changes persist. We extended the original protocol to include an additional postflight blood and urine sample collection 30 days after landing. Data are being collected before, during, and after flight. These data will provide a complete survey of how nutritional status and related systems are affected by space flight. Analyzing the data will help us to define nutritional requirements for long-duration missions. This expanded set of measurements will also aid in the identification of nutritional countermeasures to counteract, for example, the deleterious effects of microgravity on bone and muscle and the effects of space radiation.

Smith, S. M.↗

Nutritional Status Assessment (SMO 016E)

The Nutritional Status Assessment Supplemental Medical Objective was initiated to expand nominal clinical nutrition testing of ISS astronauts, and to gain a better understanding of the time course of changes in nutritional status during flight. The primary activity of this effort was collecting blood and urine samples during flight for analysis after return to Earth. Samples were subjected to a battery of tests. The resulting data provide a comprehensive survey of how nutritional status and related systems are affected by 4-6 months of space flight. Analysis of these data has yielded many findings to date, including: Vision. Documented evidence that biochemical markers involved in one-carbon metabolism were altered in crewmembers who experienced vision-related issues during and after flight (1). Iron, Oxidative Stress, and Bone. In-flight data document a clear association of increased iron stores, markers of oxidative damage to DNA, and bone loss (2). Exercise. Documented that well-nourished crewmembers performing heavy resistance exercise returned from ISS with bone mineral densities unchanged from preflight (3). Furthermore, the response of bone to space flight and exercise countermeasures was the same in men and women (4). Body Mass. Crewmembers lose 2-5% of their body mass in the first month of flight, and maintain the lower body mass during flight (5). Additionally, the two devices to measure body mass on orbit, the SLAMMD and BMMD, provide similar results (5). Cytokines. Findings indicated that a pattern of persistent physiological adaptations occurs during space flight that includes shifts in immune and hormonal regulation (6). Fish/Bone. Documented a relationship between fish intake and bone loss in astronauts (that is, those who ate more fish lost less bone) (7). Vitamin K. Documented that in generally well-fed and otherwise healthy individuals, vitamin K status and bone vitamin K-dependent proteins are unaffected by space flight (and bed rest) (8). Testosterone. Documented that blood concentrations of testosterone were unchanged during flight, but a transient decline occurred after landing (9). Calcium. Nutrition SMO data contributed to the ISS Program by helping understand how and why the Urine Processor Assembly clogged with calcium sulfate precipitate (10). Sample Processing. Ground-based analytical testing results have also been published (11).

Smith, S. M.↗

Nutritional Status Assessment (SMO -16E)

The Nutritional Status Assessment Supplemental Medical Objective was an experiment initiated to expand nominal pre- and postflight clinical nutrition testing, and to gain a better understanding of the time course of changes during flight. The primary activity of this effort was collecting blood and urine samples 5 times during flight for analysis after return to Earth. Samples were subjected to a battery of tests, including nutritional, physiological, general chemistry, and endocrinology indices. These data provide a comprehensive survey of how nutritional status and related systems are affected by 4-6 months of space flight. Analyzing the data will help us to define nutritional requirements for long-duration missions, and better understand human adaptation to microgravity. This expanded set of measurements will also aid in the identification of nutritional countermeasures to counteract, for example, the deleterious effects of microgravity on bone and muscle and the effects of space radiation.

Smith, Scott M.↗

Validation of Procedures for Monitoring Crewmember Immune Function

There is ample evidence to suggest that space flight leads to immune system dysregulation. This may be a result of microgravity, confinement, physiological stress, radiation, environment or other mission-associated factors. The clinical risk (if any) from prolonged immune dysregulation during exploration-class space flight has not yet been determined, but may include increased incidence of infection, allergy, hypersensitivity, hematological malignancy or altered wound healing. Each of the clinical events resulting from immune dysfunction has the potential to impact mission critical objectives during exploration-class missions. To date, precious little in-flight immune data has been generated to assess this phenomenon. The majority of recent flight immune studies have been post-flight assessments, which may not accurately reflect the in-flight status of immunity as it resolves over prolonged flight. There are no procedures currently in place to monitor immune function or its effect on crew health. The objective of this Supplemental Medical Objective (SMO) is to develop and validate an immune monitoring strategy consistent with operational flight requirements and constraints. This SMO will assess immunity, latent viral reactivation and physiological stress during both short and long duration flights. Upon completion, it is expected that any clinical risks resulting from the adverse effects of space flight on the human immune system will have been determined. In addition, a flight-compatible immune monitoring strategy will have been developed with which countermeasures validation could be performed. This study will determine, to the best level allowed by current technology, the in-flight status of crewmembers' immune systems. The in-flight samples will allow a distinction between legitimate in-flight alterations and the physiological stresses of landing and readaptation which are believed to alter R+0 assessments. The overall status of the immune system during flight (activation, deficiency, dysregulation) and the response of the immune system to specific latent virus reactivation (known to occur during space flight) will be thoroughly assessed. The first in-flight activity for integrated immunity very recently occurred during the STS-120 Space Shuttle mission. The protocols functioned well from a technical perspective, and accurate in-flight data was obtained from 1 Shuttle and 2 ISS crewmembers. Crew participation rates for the study continue to be robust.

Crucian, Brian↗

Electrochemical Impedance Spectroscopy of Alloys in a Simulated Space Shuttle Launch Environment

Corrosion studies began at NASA/Kennedy Space Center in 1966 during the Gemini/Apollo Programs with the evaluation of long-term protective coatings for the atmospheric protection of carbon steel. An outdoor exposure facility on the beach near the launch pad was established for this purpose at that time. The site has provided over 35 years of technical information on the evaluation of the long-term corrosion performance of many materials and coatings as well as on maintenance procedures. Results from these evaluations have helped NASA find new materials and processes that increase the safety and reliability of our flight hardware, launch structures, and ground support equipment. The launch environment at the Kennedy Space Center (KSC) is extremely corrosive due to the combination of ocean salt spray, heat, humidity, and sunlight. With the introduction of the Space Shuttle in 1981, the already highly corrosive conditions at the launch pad were rendered even more severe by the acidic exhaust from the solid rocket boosters. Over the years, many materials have been evaluated for their corrosion performance under conditions similar to those found at the launch pads. These studies have typically included atmospheric exposure and evaluation with conventional electrochemical methods such as open circuit potential (OCP) measurements, polarization techniques, and electrochemical impedance spectroscopy (EIS). The atmosphere at the Space Shuttle launch site is aggressive to most metals and causes severe pitting in many of the common stainless steel alloys such as type 304L stainless steel (304L SS). A study was undertaken to find a more corrosion resistant material to replace the existing 304L SS tubing. This paper presents the results from atmospheric exposure as well as electrochemical measurements on the corrosion resistance of AL-6XN (UNS N08367) and 254-SMO (UNS S32154). Type 304L SS (UNS S30403) was used as a control. Conditions at the Space Shuttle launch pad were simulated by using a hydrochloric acid (HC1) and alumina (Al203) slurry rinse for the atmospheric exposure and an electrolyte consisting of 3.55% sodium chloride (NaC1) with increased concentrations of hydrochloric acid (HC1) for the electrochemical measurements. The results from both types of measurements revealed the superior corrosion performance of the higher-alloyed materials. Unlike 304L SS, 254-SMO and AL-6XN exhibited a significantly improved resistance to corrosion as the concentration of hydrochloric acid in he 3.55% NaCl electrolyte solution was increased.

Calle, L. M.↗

Electrochemical Evaluation of Stainless Steels in Acidified Sodium Chloride Solutions

This paper presents the results of an investigation in which several 300-series stainless steels (SS): AISI S30403 SS (UNS S30403), AISI 316L SS (UNS S31603), and AISI 317L SS (LINS S31703), as well as highly-alloyed: SS 254-SMO (UNS S32154), AL-6XN (N08367) and AL29-4C (UNS S44735), were evaluated using DC electrochemical techniques in three different electrolyte solutions. The solutions consisted of neutral 3.55% NaCl, 3.55% NaCl in 0.1N HCl, and 3.55% NaCl in 1.0N HCl. These solutions were chosen to simulate environments that are less, similar, and more aggressive, respectively, than the conditions at the Space Shuttle launch pads. The electrochemical test results were compared to atmospheric exposure data and evaluated for their ability to predict the long-term corrosion performance of the subject alloys. The electrochemical measurements for the six alloys indicated that the higher-alloyed SS 254-SMO, AL29-4C, and AL-6XN exhibited significantly higher resistance to localized corrosion than the 300-series SS. There was a correlation between the corrosion performance of the alloys during a two-year atmospheric exposure and the corrosion rates calculated from electrochemical (polarization resistance) measurements.

Calle, L. M.↗

Development of 2.05 µm Fiber Lasers for CO2 DIAL Lidar Measuring Martian CO2 and Pressure

The Decadal Survey by the National Academy of Sciences in the United States and NASA’s Science Mission Directorate (SMD) Science Plan both require global CO 2 observations for the Martian atmospheric pressure, dynamics and chemistry. However, there are significant observational gaps in polar regions and during nighttime for global air pressure and CO 2 on Mars. Therefore, recently we proposed a new concept of Martian differential absorption lidar (DIAL) operating in the 2.05 µm CO 2 absorption band for global, including poles, atmospheric CO 2 and pressure observations day and night [1]. Based on the concept, we are awarded to develop 2.05 µm fiber lasers by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Program. The laser is designed to be an all-fiber master oscillator and power amplifier (MOPA) system with laser output of ~3 mJ at a repetition frequency of 2 kHz. The primary master oscillator (PMO) is locked to the center (2.0504280 µm) of the selected CO 2 absorption line. The frequency of a second MO (SMO) is locked to that of PMO. This SMO frequency is adjustable and switched between the online (2.05044156 µm) and offline (2.05050812 µm) wavelengths. The online wavelength is optimally selected so that the CO 2 absorption optical depth (AOD) is ~1.1 at 3 km and the measurement in the low Martian atmosphere has largest signal-to-noise ratio. The online wavelength can also be adjusted to a line slope location where AOD is larger to observe atmospheric pressure at higher altitudes. We will present more detail about this project and instrument development at the conference.

Zhaoyan Liu↗

Progress of 2.05 μm Fiber Laser Development for CO2 DIAL Measurements of Martian CO2 and Pressure

The Decadal Survey by the US National Academy of Sciences in the United States and NASA’s Science Mission Directorate (SMD) Science Plan both require global CO2 observations for the Martian atmospheric pressure, dynamics and CO2 variations. However, there are significant observational gaps in polar regions and during nighttime for global air pressure and CO2 on Mars. Therefore, recently we proposed a new concept of Martian differential absorption lidar (DIAL) operating in the 2.05 μm CO2 absorption band for global, including poles, atmospheric CO2 and pressure observations day and night. Based on the concept, we are awarded to develop 2.05 μm fiber lasers by the NASA Planetary Instrument Concepts for the Advancement of Solar System Observations (PICASSO) Program. The laser is designed to be an all-fiber master oscillator and power amplifier (MOPA) system with laser out put of ~3 mJ at a repetition frequency of 2 kHz. The primary master oscillator (PMO) is locked to the center (2.0504280 μm) of the selected CO2 absorption line. The frequency of a second MO (SMO) is locked to that of PMO. This SMO frequency is adjustable and switched between the online (2.05044156 μm) and offline (2.05050812 μm) wavelengths. The online wavelength is optimally selected so that the CO2 absorption optical depth (AOD) is ~1.1 at 3 km and the measurement in the low Martian atmosphere has largest signal-to-noise ratio. The online wavelength can also be adjusted to a line slope location where AOD is larger to observe atmospheric pressure at higher altitudes. We will present more details about this project and instrument development.

CO2↗

Program and Project Management Framework

The primary objective of this project was to develop a framework and system architecture for integrating program and project management tools that may be applied consistently throughout Kennedy Space Center (KSC) to optimize planning, cost estimating, risk management, and project control. Project management methodology used in building interactive systems to accommodate the needs of the project managers is applied as a key component in assessing the usefulness and applicability of the framework and tools developed. Research for the project included investigation and analysis of industrial practices, KSC standards, policies, and techniques, Systems Management Office (SMO) personnel, and other documented experiences of project management experts. In addition, this project documents best practices derived from the literature as well as new or developing project management models, practices, and techniques.

Butler, Cassandra D.↗

Validation of Procedures for Monitoring Crewmember Immune Function

There is ample evidence to suggest that space flight leads to immune system dysregulation, however the nature of the phenomenon as it equilibrates over longer flights has not been determined. This dysregulation may be a result of microgravity, confinement, physiological stress, radiation, environment or other mission-associated factors. The clinical risk (if any) for exploration-class space flight is unknown, but may include increased incidence of infection, allergy, hypersensitivity, hematological malignancy or altered wound healing. The objective of this Supplemental Medical Objective (SMO) is to determine the status of the immune system, physiological stress and latent viral reactivation (a clinical outcome that can be measured) during both short and long-duration spaceflight. In addition, this study will develop and validate an immune monitoring strategy consistent with operational flight requirements and constraints. Pre-mission, in-flight and post-flight blood and saliva samples will be obtained from participating crewmembers. Assays included peripheral immunophenotype, T cell function, cytokine profiles (RNA, intracellular, secreted), viral-specific immunity, latent viral reactivation (EBV, CMV, VZV), and stress hormone measurements. This study is currently ongoing. To date, 10 short duration and 5 long-duration crewmembers have completed the study. Technically, the study is progressing well. In-flight blood samples are being collected, and returned for analysis, including functional assays that require live cells. For all in-flight samples to date, sample viability has been acceptable. Preliminary data (n = 4/7; long/short duration, respectively) indicate that distribution of most peripheral leukocyte subsets is largely unaltered during flight. Exceptions include elevated T cells, reduced B/NK cells, increased memory T cells and increased central memory CD8+ T cells. General T cell function, early blastogenesis response to mitogenic stimulation, is markedly reduced in-flight. In-vivo cytokine production profiles are altered, with in-flight dysregulation observed in the Th1/Th2/Treg equilibrium. EBV specific T cell levels are increased during flight, whereas their function is reduced. VZV reactivation was observed inflight and several days post flight with highest levels measured later during long-duration flight. The shedding of CMV in the urine was detected of 4/5 long duration and 4/7 short duration crewmembers. Plasma cortisol was not elevated during flight. Further data will be required to validate the initial observations.

Crucian, Brian↗

Biosensors for EVA: Improved Instrumentation for Ground-based Studies

During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group has developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO 2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO 2 on the leg during cycling. Our NSBRI project has 4 objectives: (1) increase the accuracy of the metabolic rate calculation through improved prediction of stroke volume; (2) investigate the relative contributions of calf and thigh oxygen consumption to metabolic rate calculation for walking and running; (3) demonstrate that the NIRS-based noninvasive metabolic rate methodology is sensitive enough to detect decrement in VO 2 in a space analog; and (4) improve instrumentation to allow testing within a spacesuit. Over the past year we have made progress on all four objectives, but the most significant progress was made in improving the instrumentation. The NIRS system currently in use at JSC is based on fiber optics technology. Optical fiber bundles are used to deliver light from a light source in the monitor to the patient, and light reflected back from the patient s muscle to the monitor for spectroscopic analysis. The fiber optic cables are large and fragile, and there is no way to get them in and out of the test spacesuit used for ground-based studies. With complimentary funding from the US Army, we undertook a complete redesign of the sensor and control electronics to build a novel system small enough to be used within the spacesuit and portable enough to be used by a combat medic. In the new system the filament lamp used in the fiber optic system was replaced with a novel broadband near infrared LED light source. The compact grating spectrometer was replaced with a chip-scale spectrometer. With this new design, the sensor is 4 in 2 in 0.5 in, weighs 60 g, and no fiber optic cables are needed. The sensor, which contains the light source and the spectrometer, is adhered directly to the skin with medical grade adhesive. The sensor can be powered via the USB port of the laptop computer that controls the sensor operation. Alternatively, for studies in the spacesuit, the sensor can be powered by a small battery pack and operated by an ultra-portable hand-held computer. Both the handheld computer and battery pack will easily fit within the PLSS of the test spacesuit. System automation was significantly improved, to add features suggested by our colleagues in the Cardiovascular Laboratory and the NASA JSC Exercise Physiology and Countermeasures Project. The functionality and portability of this system were demonstrated in our UMass laboratory.

Soller, B.↗

Validation of Procedures for Monitoring Crewmember Immune Function

The objective of this Supplemental Medical Objective (SMO) is to determine the status of the immune system, physiological stress and latent viral reactivation (a clinical outcome that can be measured) during both short and long-duration spaceflight. In addition, this study will develop and validate an immune monitoring strategy consistent with operational flight requirements and constraints. Pre-mission, in-flight and post-flight blood and saliva samples will be obtained from participating crewmembers. Assays included peripheral immunophenotype, T cell function, cytokine profiles, viral-specific immunity, latent viral reactivation (EBV, CMV, VZV), and stress hormone measurements. To date, 18 short duration (now completed) and 8 long-duration crewmembers have completed the study. The long-duration phase of this study is ongoing. For this presentation, the final data set for the short duration subjects will be discussed.

Pierson, Duane↗

Human Research Program Human Health Countermeasures Element Cardiovascular Risks Standing Review Panel (SRP)

The Cardiovascular Risk Standing Review Panel (SRP) evaluated several cardiovascular risks associated with space flight along with the ongoing and emerging plans to study these issues and potentially propose and/or develop countermeasures. The areas of focus included: 1) The risk of cardiac rhythm problems during prolonged space flight, and 2) Issues related to the risk of orthostatic intolerance during re-exposure to gravity. An emerging area of concern is radiation associated vascular injury. The risk of cardiac rhythm disturbances has emerged based on case reports only. No systematic study of this risk has been published. However, concerns about this risk are heightened by the age range of astronauts, the structural changes in the heart that occur during space flight, and the potential shifts in fluids and electrolytes. The current plan is to use prolonged Holter monitor EKG records made as part of the "Integrated Cardiovascular SMO" in space to determine more about the frequency and magnitude of this problem and to link this data to complementary data from the nutrition group on electrolytes. The SRP was supportive of this approach. The SRP also felt that any data related to cardiovascular risk in space should be better coordinated with the medical screening data that all astronauts undergo at regular intervals. Additionally, while there are potential privacy issues related to this suggestion, many of the current barriers to better coordination of experimental and clinical data appear to reflect longstanding cultural traditions at NASA that need rethinking. The risk of orthostatic intolerance during re-exposure to gravity was seen by the SRP as an area supported by a wealth of published physiological evidence. The SRP also felt that moving forward with the planned approach to countermeasures was reasonable and that extensive additional hypothesis testing on the physiology of orthostatic intolerance was not needed at this time. There was support for developing ground based models of limited (e.g. 1/6 th) G environments on Earth that generated a number of ideas for consideration by NASA investigators.

Joyner, Michael↗

Corrosion Performance of Stainless Steels in a Simulated Launch Environment

At the Kennedy Space Center, NASA relies on stainless steel (SS) tubing to supply the gases and fluids required to launch the Space Shuttle. 300 series SS tubing has been used for decades but the highly corrosive environment at the launch pad has proven to be detrimental to these alloys. An upgrade with higher alloy content materials has become necessary in order to provide a safer and long lasting launch facility. In the effort to find the most suitable material to replace the existing AISI 304L SS ([iNS S30403) and AISI 316L SS (UNS S31603) shuttle tubing, a study involving atmospheric exposure at the corrosion test site near the launch pads and electrochemical measurements is being conducted. This paper presents the results of an investigation in which stainless steels of the 300 series, 304L, 316L, and AISI 317L SS (UNS S31703) as well as highly alloyed stainless steels 254-SMO (UNS S32154), AL-6XN (N08367) and AL29-4C ([iNS S44735) were evaluated using direct current (DC) electrochemical techniques under conditions designed to simulate those found at the Space Shuttle Launch pad. The electrochemical results were compared to the atmospheric exposure data and evaluated for their ability to predict the long-term corrosion performance of the alloys.

Calle, Luz Marina↗

Fibroblast Growth Factor-23 in Bed Rest and Spaceflight

Many nutritional factors influence bone, from the basics of calcium and vitamin D, to factors which influence bone through acid/base balance, including protein, sodium, and more. Fibroblast growth factor 23 (FGF23) is a recently identified factor, secreted from osteocytes, which is involved in classic (albeit complex) feedback loops controlling phosphorus homeostasis through both vitamin D and parathyroid hormone (PTH) (1, 2). As osteocytes are gravity sensing cells, it is important to determine if there are changes in FGF23 during spaceflight. In extreme cases, such as chronic kidney disease, FGF23 levels are highly elevated. FGF23 imbalances, secondary to dietary influences, may contribute to skeletal demineralization and kidney stone risk during spaceflight. Presented with an imbalanced dietary phosphorus to calcium ratio, increased secretion of FGF23 will inhibit renal phosphorus reabsorption, resulting in increased excretion and reduced circulating phosphorus. Increased intake and excretion of phosphorus is associated with increased kidney stone risk in both the terrestrial and microgravity environments. Highly processed foods and carbonated beverages are associated with higher phosphorus content. Ideally, the dietary calcium to phosphorus ratio should be at minimum 1:1. Nutritional requirements for spaceflight suggest that this ratio not be less than 0.67 (3), while the International Space Station (ISS) menu provides 1020 mg Ca and 1856 mg P, for a ratio of 0.55 (3). Subjects in NASA's bed rest studies, by design, have consumed intake ratios much closer to 1.0 (4). FGF23 also has an inhibitory influence on PTH secretion and 1(alpha)-hydroxylase, both of which are required for activating vitamin D with the conversion of 25-hydroxyvitamin D to 1,25-dihydroxyvitamin D. Decreased 1,25-dihydroxyvitamin D will result in decreased intestinal phosphorus absorption, and increased urinary phosphorus excretion (via decreased renal reabsorption). Should a decrease in 1,25- dihydroxyvitamin D be necessary to reduce intestinal phosphorus absorption, calcium absorption will also proportionally be reduced, potentially leading to skeletal demineralization. Demineralization of bone can increase kidney stone risk, a medical issue that could prove detrimental to mission success. Given the interrelationships described above, we sought to determine circulating FGF23 concentrations in spaceflight and ground analog studies to better understand the potential effects of dietary phosphorus on bone and calcium metabolism. We analyzed serum from ISS astronauts participating in studies of bone biochemistry, including the Nutrition SMO and Pro K experiments, and we also evaluated FGF23 during extended-duration bed rest. Serum intact FGF23 levels were determined using an ELISA kit from Kainos laboratories in Japan. While initial evaluation of the data showed no changes over time during flight or bed rest, evaluation continues of FGF23 data in light of dietary factors, PTH, vitamin D status, and other biochemical and endocrine factors.

Bokhari, R.↗