Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sleeves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Swell Sleeves for Testing Explosive Devices

A method of testing explosive and pyrotechnic devices involves exploding the devices inside swell sleeves. Swell sleeves have been used previously for measuring forces. In the present method, they are used to obtain quantitative indications of the energy released in explosions of the devices under test. A swell sleeve is basically a thick-walled, hollow metal cylinder threaded at one end to accept a threaded surface on a device to be tested (see Figure 1). Once the device has been tightly threaded in place in the swell sleeve, the device-and-swell-sleeve assembly is placed in a test fixture, then the device is detonated. After the explosion, the assembly is removed from the test fixture and placed in a coordinate-measuring machine for measurement of the diameter of the swell sleeve as a function of axial position. For each axial position, the original diameter of the sleeve is subtracted from the diameter of the sleeve as swollen by the explosion to obtain the diametral swelling as a function of axial position (see Figure 2). The amount of swelling is taken as a measure of the energy released in the explosion. The amount of swelling can be compared to a standard amount of swelling to determine whether the pyrotechnic device functioned as specified.

Hinkel, Todd J.↗

Molybdenum Sleeve Experiments in Fully-Reflected Water-Moderated Triangular-Pitched U(6.90)O 2 Fuel Rod Lattices (1.55 cm Pitch)

The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMP-THERM-096, LEUCOMP-THERM-097, LEU-COMP-THERM-101, and LEU-COMP-THERM-102. The purpose of these experiments was to measure the effects of molybdenum in nearly-critical systems. The molybdenum was introduced into the fuel arrays as tubular sleeves that surrounded some of the fuel rods in the fuel arrays measured. Four hundred molybdenum tubes nominally 12.7 mm outside diameter, 498 mm long, with 0.762 mm wall thickness were provided for the experiments by the Institut de Radioprotection et de Sûreté Nucléaire (IRSN). Small polyethylene adapters at each end of the tubes were used to center each tube on a fuel rod in the assembly. The critical experiments were done using a set of triangular-pitched grid plates fabricated for these experiments. The grid plate set accommodated a fuel array of a total of 1261 fuel rod positions on a pitch of 0.610 in (1.5494 cm) in a series of 20 hexagonal rings surrounding the central fuel rod. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The five critical experiments in this series were performed in August through December 2022, in the Sandia Critical Experiments (SCX) at the Sandia Pulsed Reactor Facility. Case 1 had no molybdenum sleeves, Case 2 had 208 molybdenum sleeves clustered at the center of the array, Case 3 had 397 molybdenum sleeves clustered at the center of the array, Case 4 had 175 molybdenum sleeves in the central position and in five alternating hexagonal rings, and Case 5 had 331 molybdenum sleeves in the central position and in seven alternating hexagonal rings. All five critical experiments are judged to be acceptable as benchmark experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanical Analysis of Carbon Fiber Retaining Sleeve for A High-speed Outer Rotor SPM Electric Motor Design

Outer rotor motors can be designed with a larger airgap diameter than inner rotor motors for the same overall diameter and therefore provide higher torque which makes them ideal for high torque space constrained applications. This advantage fits well with the increasing demand of high-speed electric machines in many applications due to their inherent high-power density. However, increasing the motor speed results in significant centrifugal loads for the outer rotor motor design. Layers of carbon fiber sleeve winding on the rotor outer surface is necessary to guarantee its structural integrity without introducing too much weight on the motor itself. In this paper, we studied the mechanical stress of a carbon fiber retaining sleeve in a surface permanent magnet outer rotor motor that spins up to 20,000 RPM. Analytical results from finite element method (FEM) confirmed that the maximum stress experienced by the carbon fiber sleeve was under the material’s yield strength. The proposed sleeve will allow this outer rotor motor to operate at high speeds.

Lin, Lianshan↗

Effect of Viscosity on Fuel Leakage Between Lapped Plungers and Sleeves and on the Discharge from a Pump-Injection System

Test data and analysis show that the rate of fuel leakage between a lapped plunger and sleeve varies directly with the density of the fuel, the diameter of the plunger, the pressure producing the leakage, and the cube of the mean clearance between the plunger and sleeve. The rate varies inversely as the length of the lapped fit and the viscosity of the fuel. With a mean clearance between the plunger and sleeve of 0.0001 inch the leakage amounts to approximately 0.2 percent of the fuel injected with gasoline and as low as 0.01 percent with diesel fuel oils. With this mean clearance an effective seal is obtained when the length of the lap is three times the diameter of the lap. The deformation of the sleeve and plunger under pressure is sufficient to change the rate of leakage appreciably from that which would be obtained if the clearance was constant under pressure.

Rothrock, A M↗

Insulation Testing Using Cryostat Apparatus with Sleeve

The method and equipment of testing continuously rolled insulation materials is presented in this paper. Testing of blanket and molded products is also facilitated. Materials are installed around a cylindrical copper sleeve using a wrapping machine. The sleeve is slid onto the vertical cold mass of the cryostat. The gap between the cold mass and the sleeve measures less than 1 mm. The cryostat apparatus is a liquid nitrogen boiloff calorimeter system that enables direct measurement of the apparent thermal conductivity (k-value) of the insulation system at any vacuum level between 5 x 10(exp -5) and 760 torr. Sensors are placed between layers of the insulation to provide complete temperature-thickness profiles. The temperatures of the cold mass (maintained at 77.8 kelvin (K)), the sleeve (cold boundary temperature (CBT)), the insulation outer surface (warm boundary temperature (WBT)), and the vacuum can (maintained at 313 K by a thermal shroud) are measured. Plots of CBT, WBT, and layer temperature profiles as functions of vacuum level show the transitions between the three dominant heat transfer modes. For this cryostat apparatus, the measureable heat gain is from 0.2 to 20 watts. The steady-state measurement of k-value is made when all temperatures and the boiloff rate are stable.

Fesmire, J. E.↗

Sleeve and cutter simplify disconnecting welded joint in tubing

To test equipment, welded tubing joints may have to be disconnected and rewelded. To eliminate rewelding, a nonstandard welding sleeve permits the tubing to be welded and then disconnected by a specially designed sleeve cutter. Use of this tool assures that only the sleeve is cut.

Perkins, G. S.↗

Sleeve puller salvages welded tubes

Tool removes sleeve remnants without distorting or damaging tubes, unlike pliers and other conventional handtools. Tubes can be reused, saving time, labor, and material in many applications. Sleeve-removal fixture consists of pressure screw, swing arm, locking screws, and base. It removes sleeve remnant from tubing after welded joint has been sawed through.

Weaver, J. F.↗

Soft Sleeve Between Glove Box And Instrument

Sleeve protects instrument from low frequency vibrations and helps maintain clean atmosphere for semiconductor analysis. Flexible sleeve joins glove box to specimen-introduction port of instrument chamber. Coupling made of brown nylon with inner layer of white rubber, attached to both areas with specially designed clamps. Thickness of sleeve material 0.01 in.

Lombardi, Frank↗

Split mandrel versus split sleeve coldworking: Dual methods for extending the fatigue life of metal structures

It is common practice to use split sleeve coldworking of fastener holes as a means of extending the fatigue life of metal structures. In search of lower manufacturing costs, the aerospace industry is examining the split mandrel (sleeveless) coldworking process as an alternative method of coldworking fastener holes in metal structures. The split mandrel process (SpM) significantly extends the fatigue life of metal structures through the introduction of a residual compressive stress in a manner that is very similar to the split sleeve system (SpSl). Since the split mandrel process is significantly less expensive than the split sleeve process and more adaptable to robotic automation, it will have a notable influence upon other new manufacture of metal structures which require coldworking a significant number of holes, provided the aerospace community recognizes that the resulting residual stress distributions and fatigue life improvement are the same for both processes. Considerable testing has validated the correctness of that conclusion. The findings presented in this paper represent the results of an extensive research and development program, comprising data collected from over 400 specimens fabricated from 2024-T3 and 7075-T651 aluminum alloys in varied configurations, which quantify the benefits (fatigue enhancement and cost savings) of automating a sleeveless coldworking system.

Rodman, Geoffrey A.↗

Molybdenum Sleeves Experiments in the Sandia Critical Experiments Facility

Sandia National Laboratories and the Institut de Radioprotection et de Sûreté Nucléaire have collaborated on the design and execution of a set of critical experiments that explore the effects of molybdenum in water-moderated fuel-rod arrays. The molybdenum was included as sleeves on some of the fuel rods in the critical experiment fuel arrays. Approach-to-critical experiments were performed on five configurations of fuel and molybdenum sleeves using the 7uPCX fuel in core hardware that set the triangular fuel rod pitch at 15.494 mm. The experiments are evaluated as benchmark critical experiments for the 2023 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook as LEU-COMP-THERM-111.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Shrinkable sleeve eliminates shielding gap in RF cable

RF shielding gap between an RF cable and a multipin connector is eliminated by a sleeve assembly installed between the connector and the terminated portion of the shielding. The assembly is enclosed in a heat-shrinkable plastic sleeve which completes the continuous RF shield.

Source record↗

Special tool seals conductors with combination of plastic sleeves

Special tool seals electrical conductors connecting instrumentation within space vehicle cryogenic fuel tanks and oxidizer tanks. An inner sleeve of fluorinated ethylene-propylene and an outer sleeve of tetrafluoroethylene enclose a bundle of conductors and are heated with the tool to form a tight seal of the bundle and each individual wire.

Young, S.↗

Insert sleeve prevents tube soldering contamination

Teflon sleeve insert prevents contamination of internal tube surfaces by solder compound during soldering operations that connect and seal the tube ends. The sleeve insert is pressed into the mating tube ends with a slight interference fit.

Stein, J.↗

Use of color-coded sleeve shutters accelerates oscillograph channel selection

Sleeve-type shutters mechanically adjust individual galvanometer light beams onto or away from selected channels on oscillograph papers. In complex test setups, the sleeve-type shutters are color coded to separately identify each oscillograph channel. This technique could be used on any equipment using tubular galvanometer light sources.

Bouchlas, T.↗

Retaining a sleeve on a shaft

Snap ring with slotted tabs fits groove in shaft. Sleeve to be held on shaft fits over snap ring keeping it from expanding. Tabs are bent out to keep sleeve from slipping off shaft.

Pessin, R.↗

Alining sleeve for optical fibers

Sleeve for alining two optical fibers is made with precisely correct inside diameter by using section of fiber as mandrel. Because optical fiber is manufactured to very close tolerances, diameter of section serving as mandrel will be same as diameters of two fibers that are mated in butt joint inside sleeve. Result, determined by experiments, is loss of no more that 0.3 dB at joint.

Austin, K. L.↗

Flow-Straightener Sleeve for Pump Valve

Flow-straightening sleeve contains vanes in modified honeycomb pattern. Each vane curved fluid-dynamic wing that helps straighten and smooth out flow of fluid passing over it. Sleeve performs more reliably and quietly, possibility of damage to internal valve parts greatly reduced, valve life expectancy increased and time between overhauls extended.

Tolpen, J.↗