Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Single-photon detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cooled avalanche photodiode used for photon detection

Commercial avalanche photodiodes have been operated as single-photon detectors at an optimum operating temperature and bias voltage. These detectors were found to be 1.5 to 3 times more sensitive than presently-available photomultiplier tubes (PPMTs). Both single-photon detection probability and detector noise increase with bias voltage; detection probabilities greater than 25 percent were obtained with detector noise levels comparable to the noise of a PMT; higher probabilities were measured at higher noise levels. The sources of noise and their dependence on temperature and bias voltage are discussed.

Robinson, Deborah L.↗

Photon detection with cooled avalanche photodiodes

Commercial avalanche photodiodes have been operated as single-photon detectors at an optimum operating temperature and bias voltage. These detectors were found to be 1.5-3 times more sensitive than presently available photomultiplier tubes (PMTs). Both single-photon detection probability and detector noise increase with bias voltage; detection probabilities greater than twice that of a PMT were obtained with detector noise levels below 100 counts per second. Higher probabilities were measured at higher noise levels. The sources of noise and their dependence on temperature and bias voltage are discussed.

Robinson, D. L.↗

Effect of detector dead time on the performance of optical direct-detection communication links

Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detection sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulated (PPM) channel is studied by analyzing the error probability. It is shown that, when background noise is negligible, the performance of the detector with dead time is similar to that of a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on badkground intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.

Chen, C.-C.↗

Effect of Detector Dead Time on the Performance of Optical Direct-Detection Communication Links

Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detect ion sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulted (PPM) channel is studied by analyzing the error probability. It is shown that, when back- ground noise is negligible, the performance of the detector with dead time is similar to that o f a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on background intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.

Chen, C.-C.↗

Direct-detection Free-space Laser Transceiver Test-bed

NASA Goddard Space Flight Center is developing a direct-detection free-space laser communications transceiver test bed. The laser transmitter is a master-oscillator power amplifier (MOPA) configuration using a 1060 nm wavelength laser-diode with a two-stage multi-watt Ytterbium fiber amplifier. Dual Mach-Zehnder electro-optic modulators provide an extinction ratio greater than 40 dB. The MOPA design delivered 10-W average power with low-duty-cycle PPM waveforms and achieved 1.7 kW peak power. We use pulse-position modulation format with a pseudo-noise code header to assist clock recovery and frame boundary identification. We are examining the use of low-density-parity-check (LDPC) codes for forward error correction. Our receiver uses an InGaAsP 1 mm diameter photocathode hybrid photomultiplier tube (HPMT) cooled with a thermo-electric cooler. The HPMT has 25% single-photon detection efficiency at 1064 nm wavelength with a dark count rate of 60,000/s at -22 degrees Celsius and a single-photon impulse response of 0.9 ns. We report on progress toward demonstrating a combined laser communications and ranging field experiment.

Krainak, Michael A.↗

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.↗

Solid-State Single-Photon Counter

Avalanche photodiode used to detect single photons if cooled to optimum temperature and overbiased beyond breakdown voltage. Offers two to three times sensitvity of photomultiplier tubes commonly used for photon detection. When cooled to reduce number of thermal carriers, avalanche photodiode reverse-biased beyond normal breakdown voltage to give it extremely-high internal gain of 10 to seventh power to 10 to eigth power. Advantages of solid-state devices to applications requiring low-level light detection, optical communication, astronomy, remote sensing, optical metrology, and optical signal processing.

Robinson, D. L.↗

A loophole-free Bell's inequality experiment

The proof of Nature's nonlocality through Bell-type experiments is a topic of longstanding interest. Nevertheless, no experiments performed thus far have avoided the so-called 'detection loophole,' arising from low detector efficiencies and angular-correlation difficulties. In fact, most, if not all, of the systems employed to date can never close this loophole, even with perfect detectors. In addition, another loophole involving the non-rapid, non-random switching of various parameter settings exists in all past experiments. We discuss a proposal for a potentially loophole-free Bell's inequality experiment. The source of the EPR-correlated pairs consists of two simultaneously-pumped type-2 phase-matched nonlinear crystals and a polarizing beam splitter. The feasibility of such a scheme with current detector technology seems high, and will be discussed. We also present a single-crystal version, motivated by other work presented at this conference. In a separate experiment, we have measured the absolute detection efficiency and time response of four single-photon detectors. The highest observed efficiencies were 70.7 plus or minus 1.9 percent (at 633 nm, with a device from Rockwell International) and 76.4 plus or minus 2.3 percent (at 702 nm, with an EG&G counting module). Possible efficiencies as high as 90 percent were implied. The EG&G devices displayed sub-nanosecond time resolution.

Kwiat, Paul G.↗

Development of a High-Resolution, Single-Photon X-Ray Detector

Research on the development of a low-temperature, magnetic bolometer for x-ray detection is reported. The principal accomplishments during the first phase of this research are as follows. (1) We have constructed SQUID magnetometers and detected both 122 keV and 6 keV x-rays in relatively larger metallic samples with high quantum efficiency. (2) The magnetic properties of a metal sample with localized paramagnetic spins have been measured and found to agree with theoretical expectations. (3) The size of the magnetic response of the sample to x-rays is in agreement with predictions based on the properties of the sample and sensitivity of the magnetometer, supporting the prediction that a resolution of 1 eV at 10 keV should be achievable.

Seidel, George M.↗

Satellite signatures in SLR observations

We examine the evidence for the detection of satellite-dependent signatures in the laser range observations obtained by the UK single-photon Satellite Laser Ranging (SLR) System models of the expected observation distributions from Ajisai and Lageos are developed from the published satellite spread functions and from the characteristics of the SLR System and compared with the observations. The effects of varying return strengths are discussed using the models and by experimental observations of Ajisai, during which a range of return levels from single to multiple photons is achieved. The implications of these results for system-dependent center for mass corrections are discussed.

Appleby, G. M.↗

Two-dimensional imaging of molecular hydrogen in H2-air diffusion flames using two-photon laser-induced fluorescence

The use of a tunable ArF laser at 193.26 nm to record simultaneous single-laser-shot, planar images of molecular hydrogen and hot oxygen in a turbulent H2-air diffusion flame. Excitation spectra of fuel and oxidant-rich flame zones confirm a partial overlap of the two-photon H2 and single-photon O2 Schumann-Runge absorption bands. UV Rayleigh scattering images of flame structure and estimated detection limits for the H2 two-photon imaging are also presented.

Lempert, W.↗

A low-energy gamma-ray imaging detector

We describe a hard-X-ray/soft-gamma-ray imaging detector, incorporating a microchannel-plate (MCP) electron multiplier for possible use in future telescopes. In contrast to previous attempts using MCP's this approach promises to achieve high quantum detection efficiencies in addition to high spatial and temporal resolution. Preliminary results indicate not only the capability of simultaneous imaging and single-photon counting, but also coarse energy resolution.

Yin, L. I.↗

Recommended Practices in Laser-Induced Fluorescence (LIF) Diagnostics for Electric Propulsion

Laser-induced fluorescence (LIF) spectroscopy uses Doppler-shifted laser photons to excite a bound electron transition in an atom or ion, with subsequent fluorescence emission detected in order to measure the local velocity distribution function (VDF) and/or particle density. Due to its non-invasive nature, high spatial resolution, and acceptable difficulty of implementation, LIF has become a favored diagnostic for electric propulsion (EP) plasmas, particularly in the study of Hall thrusters. This paper presents recommended best practices for LIF measurements in electric thrusters, drawn from over three decades of implementation heritage in the EP community. Focusing on both single-photon LIF (typically used to measure VDFs) and two-photon LIF (TALIF, typically used to determine densities), the paper covers selection of atomic transitions to target, experimental setups, and interpretation of data. A number of special topics and advanced applications are discussed, including uncertainty analysis, techniques for high-speed measurements, and applications to a variety of propellants.

plasma plume↗

Effect of color coding and subtraction on the accuracy of contrast echocardiography

BACKGROUND: Contrast echocardiography may be used to assess myocardial perfusion. However, gray scale assessment of myocardial contrast echocardiography (MCE) is difficult because of variations in regional backscatter intensity, difficulties in distinguishing varying shades of gray, and artifacts or attenuation. We sought to determine whether the assessment of rest myocardial perfusion by MCE could be improved with subtraction and color coding. METHODS AND RESULTS: MCE was performed in 31 patients with previous myocardial infarction with a 2nd generation agent (NC100100, Nycomed AS), using harmonic triggered or continuous imaging and gain settings were kept constant throughout the study. Digitized images were post processed by subtraction of baseline from contrast data and colorized to reflect the intensity of myocardial contrast. Gray scale MCE alone, MCE images combined with baseline and subtracted colorized images were scored independently using a 16 segment model. The presence and severity of myocardial contrast abnormalities were compared with perfusion defined by rest MIBI-SPECT. Segments that were not visualized by continuous (17%) or triggered imaging (14%) after color processing were excluded from further analysis. The specificity of gray scale MCE alone (56%) or MCE combined with baseline 2D (47%) was significantly enhanced by subtraction and color coding (76%, p<0.001) of triggered images. The accuracy of the gray scale approaches (respectively 52% and 47%) was increased to 70% (p<0.001). Similarly, for continuous images, the specificity of gray scale MCE with and without baseline comparison was 23% and 42% respectively, compared with 60% after post processing (p<0.001). The accuracy of colorized images (59%) was also significantly greater than gray scale MCE (43% and 29%, p<0.001). The sensitivity of MCE for both acquisitions was not altered by subtraction. CONCLUSION: Post-processing with subtraction and color coding significantly improves the accuracy and specificity of MCE for detection of perfusion defects.

Multicenter Study↗

NASA Tech Briefs, May 2010

Topics covered include: Instrument for Analysis of Greenland's Glacier Mills Cryogenic Moisture Apparatus; A Transportable Gravity Gradiometer Based on Atom Interferometry; Three Methods of Detection of Hydrazines; Crossed, Small-Deflection Energy Analyzer for Wind/Temperature Spectrometer; Wavefront Correction for Large, Flexible Antenna Reflector; Novel Micro Strip-to-Waveguide Feed Employing a Double-Y Junction; Thin-Film Ferro Electric-Coupled Microstripline Phase Shifters With Reduced Device Hysteresis; Two-Stage, 90-GHz, Low-Noise Amplifier; A 311-GHz Fundamental Oscillator Using InP HBT Technology; FPGA Coprocessor Design for an Onboard Multi-Angle Spectro-Polarimetric Imager; Serrating Nozzle Surfaces for Complete Transfer of Droplets; Turbomolecular Pumps for Holding Gases in Open Containers; Triaxial Swirl Injector Element for Liquid-Fueled Engines; Integrated Budget Office Toolbox; PLOT3D Export Tool for Tecplot; Math Description Engine Software Development Kit; Astronaut Office Scheduling System Software; ISS Solar Array Management; Probabilistic Structural Analysis Program; SPOT Program; Integrated Hybrid System Architecture for Risk Analysis; System for Packaging Planetary Samples for Return to Earth; Offset Compound Gear Drive; Low-Dead-Volume Inlet for Vacuum Chamber; Simple Check Valves for Microfluidic Devices; A Capillary-Based Static Phase Separator for Highly Variable Wetting Conditions; Gimballing Spacecraft Thruster; Finned Carbon-Carbon Heat Pipe with Potassium Working Fluid; Lightweight Heat Pipes Made from Magnesium; Ceramic Rail-Race Ball Bearings; Improved OTEC System for a Submarine Robot; Reflector Surface Error Compensation in Dual-Reflector Antennas; Enriched Storable Oxidizers for Rocket Engines; Planar Submillimeter-Wave Mixer Technology with Integrated Antenna; Widely Tunable Mode-Hop-Free External-Cavity Quantum Cascade Laser; Non-Geiger-Mode Single-Photon Avalanche Detector with Low Excess Noise; Using Whispering-Gallery-Mode Resonators for Refractometry; RF Device for Acquiring Images of the Human Body; Reactive Collision Avoidance Algorithm; Fast Solution in Sparse LDA for Binary Classification; Modeling Common-Sense Decisions in Artificial Intelligence; Graph-Based Path-Planning for Titan Balloons; Nanolaminate Membranes as Cylindrical Telescope Reflectors; Air-Sea Spray Airborne Radar Profiler Characterizes Energy Fluxes in Hurricanes; Large Telescope Segmented Primary Mirror Alignment; and Simplified Night Sky Display System.

Source record↗

CH(A, B-X) fluorescence from vacuum ultraviolet excitation of CH3

The fluorescence due to single-photon and two-photon excitation of CH3 produced by the reaction of CH4 with F or Cl in a flow tube is investigated experimentally. The excitation source is an excimer laser operating with pulse duration 6 nsec and repetition rate 20 Hz, and the fluorescence is observed using a 0.25-m spectrometer and a 1024-channel diode array; the results are presented graphically. Emission is detected at 157 nm (with approximate cross section 8 x 10 to the -19th sq cm) and 193 nm, but not at 248 nm. The applicability of these data to studies of hydrocarbon combustion, the methane oxidation cycle in the atmosphere, interstellar molecule formation, and diamond film fabrication is indicated.

Ye, Chao↗

Quantum Probability Cancellation Due to a Single-Photon State

When an N-photon state enters a lossless symmetric beamsplitter from one input port, the photon distribution for the two output ports has the form of Bernouli Binormial, with highest probability at equal partition (N/2 at one outport and N/2 at the other). However, injection of a single photon state at the other input port can dramatically change the photon distribution at the outputs, resulting in zero probability at equal partition. Such a strong deviation from classical particle theory stems from quantum probability amplitude cancellation. The effect persists even if the N-photon state is replaced by an arbitrary state of light. A special case is the coherent state which corresponds to homodyne detection of a single photon state and can lead to the measurement of the wave function of a single photon state.

Ou, Z. Y.↗

Interferometric Quantum-Nondemolition Single-Photon Detectors

Two interferometric quantum-nondemolition (QND) devices have been proposed: (1) a polarization-independent device and (2) a polarization-preserving device. The prolarization-independent device works on an input state of up to two photons, whereas the polarization-preserving device works on a superposition of vacuum and single- photon states. The overall function of the device would be to probabilistically generate a unique detector output only when its input electromagnetic mode was populated by a single photon, in which case its output mode would also be populated by a single photon. Like other QND devices, the proposed devices are potentially useful for a variety of applications, including such areas of NASA interest as quantum computing, quantum communication, detection of gravity waves, as well as pedagogical demonstrations of the quantum nature of light. Many protocols in quantum computation and quantum communication require the possibility of detecting a photon without destroying it. The only prior single- photon-detecting QND device is based on quantum electrodynamics in a resonant cavity and, as such, it depends on the photon frequency. Moreover, the prior device can distinguish only between one photon and no photon. The proposed interferometric QND devices would not depend on frequency and could distinguish between (a) one photon and (b) zero or two photons. The first proposed device is depicted schematically in Figure 1. The input electromagnetic mode would be a superposition of a zero-, a one-, and a two-photon quantum state. The overall function of the device would be to probabilistically generate a unique detector output only when its input electromagnetic mode was populated by a single photon, in which case its output mode also would be populated by a single photon.

Kok, Peter↗