Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Silicon calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps

Cryogenic calorimeters for low-mass dark matter searches have achieved sub-eV energy resolutions, driving advances in both low-energy calibration techniques and our understanding of detector physics. The energy deposition spectrum of gamma rays scattering off target materials exhibits step-like features, known as Compton steps, near the binding energies of atomic electrons. Here, we demonstrate a successful use of Compton steps for sub-keV calibration of cryogenic silicon calorimeters, utilizing four SuperCDMS High-Voltage eV-resolution detectors operated with 0 V bias across the crystal. This new calibration at 0 V is compared with the established high-voltage calibration using optical photons. The comparison indicates that the detector response at 0 V is about 30% weaker than expected, highlighting challenges in detector response modeling for low-mass dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and performance of a silicon–tungsten calorimeter prototype module and the associated readout

Here, we describe the details of a silicon–tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance of a custom ASIC designed for fast, lower-power, high-granularity applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A test of the Feynman scaling in the fragmentation region

The result of the direct measurement of the fragmentation region will be presented. The result will be obtained at the CERN proton-antiproton collider, being exposured the Silicon calorimeters inside beam pipe. This experiment clarifies a long riddle of cosmic ray physics, whether the Feynman scaling does villate at the fragmentation region or the Iron component is increasing at 10 to the 15th power eV.

Doke, T.↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Results from the First Flight of ATIC: The Silicon Matrix

The Advanced Thin Ionization Calorimeter (ATIC) uses a silicon matrix detector to determine charge in conjunction with a scintillator hodoscope that measures charge and trajectory. Cosmic rays that interact in a carbon target have their energy determined from the shower that develops within a fully active calorimeter composed of a stack of scintillating BGO crystals. The silicon matrix consists of 4480 individual silicon pads, each capable of measuring the signal from cosmic rays with atomic numbers from 1 to 26. Preliminary results will be presented describing the performance of the silicon matrix during the 16-day maiden flight of ATIC around Antarctica.

Adams, J. H., Jr.↗

Preliminary Results From the First Flight of ATIC: The Silicon Matrix

The Advanced Thin Ionization Calorimeter (ATIC) uses a silicon matrix detector in conjunction with a scintillator hodoscope to determine the incident cosmic ray's charge. Cosmic rays that interact in a carbon target have their energy determined from the shower that develops within a fully active calorimeter composed of a stack of scintillating BGO crystals. The silicon matrix consists of 4480 individual silicon pads, each capable of measuring the signal from cosmic rays with atomic numbers from I to 26. Preliminary results will be presented describing the performance of the silicon matrix during the 16-day maiden flight of ATIC around Antarctica.

Adams, James H., Jr.↗

Single electron–hole pair sensitive silicon detector with surface event discrimination

Here, we demonstrate single electron-hole pair resolution in a single-sided, contact-free 1 cm$^2$ by 1 mm thick Si crystal operated at 48 mK, with a baseline energy resolution of 3 eV. This crystal can be operated at voltages in excess of $\pm50$ V, resulting in a measured charge resolution of 0.06 electron-hole pairs. The high aluminum coverage ($\sim$70%) of this device allows for the discrimination of surface events and separation of events occurring near the center of the detector from those near the edge. We use this discrimination ability to show that dark events seen in previous detectors of a similar design are likely dominated by charge leakage along the side wall of the device. We saw only a small reduction in dark event rate with this biasing scheme, further suggesting that sidewall and edge-dominated processes are responsible for the majority of these events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Involving the new generations in Fermilab endeavors

Since 1984 the Italian groups of the Istituto Nazionale di Fisica Nucleare (INFN) and Italian Universities, collaborating with the DOE laboratory of Fermilab (US) have been running a two-month summer training program for Italian university students. While in the first year the program involved only four physics students of the University of Pisa, in the following years it was extended to engineering students. This extension was very successful and the engineering students have been since then extremely well accepted by the Fermilab Technical, Accelerator, and Scientific Computing Division groups. Over the many years of its existence, this program has proven to be the most effective way to engage new students in Fermilab endeavors. Many students have extended their collaboration with Fermilab with their Master’s Thesis and PhD. Since 2004 the program has been supported in part by DOE in the frame of an exchange agreement with INFN. Over its almost 40 years of history, the program has grown in scope and size and has involved more than 550 Italian students from more than 20 Italian Universities, Several Institutes of Research, including ASI and INAF in Italy, and the ISSNAF Foundation in the US, have provided additional financial support. Since the program does not exclude appropriately selected non-Italian students, a handful of students from European and non-European Universities were also accepted over the years. Each intern is supervised by a Fermilab Mentor responsible for performing the training program. Training programs spanned from Tevatron, CMS, Muon (g-2), Mu2e, and Short Baseline Neutrino Experiments and DUNE design and experimental data analysis, development of particle detectors (silicon trackers, calorimeters, drift chambers, neutrino and dark matter detectors), design of electronic and accelerator components, development of infrastructures and software for exascale data handling, research on superconductive elements and on accelerating cavities, and theory of particle accelerators. Since 2010, within an extended program supported by the Italian Space Agency and the Italian National Institute of Astrophysics, a total of 30 students in physics, astrophysics, and engineering have been hosted for two months in the summer at US space science Research Institutes and laboratories. In 2015 the University of Pisa included these programs within its educational programs. Accordingly, Summer School students are enrolled at the University of Pisa for the duration of the internship and are identified and ensured as such. At the end of the internship, the students are required to write summary reports on their achievements. After positive evaluation by a University Examining Board, interns are acknowledged credits for their Diploma Supplement. The program was canceled in 2020 and 2021 due to the pandemic but restarted successfully in 2022. We believe this program can be taken as a model and easily adopted by interested institutions.

99 GENERAL AND MISCELLANEOUS↗

Performance Testing of the Astro-H Flight Model 3-Stage ADR

The Soft X-ray Spectrometer (SXS) is one of four instruments that will be flown on the Japanese Astro-H satellite, planned for launch in late 2015early 2016. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon micro calorimeters operated at 50 mK, cooled by an adiabatic demagnetization refrigerator (ADR). NASAGSFC is providing the detector array and ADR, and Sumitomo Heavy Industries, Inc. is providing the remainder of the cryogenic system (superfluid helium dewar (1.3 K), Stirling cryocoolers and a 4.5 K Joule-Thomson (JT) cryocooler). The ADR is unique in that it is designed to use both the liquid helium and the JT cryocooler as it heat sink. The flight detector and ADR assembly have successfully undergone vibration and performance testing at GSFC, and have now undergone initial performance testing with the flight dewar at Sumitomo Heavy Industries, Inc. in Japan. This presentation summarizes the performance of the flight ADR in both cryogen-based and cryogen-free operating modes.

adiabatic demagnetization refrigerator↗

The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.

47 OTHER INSTRUMENTATION↗

Neutron irradiation and electrical characterisation of the first 8” silicon pad sensor prototypes for the CMS calorimeter endcap upgrade

As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic and hadronic compartments. Due to its compactness, intrinsic time resolution, and radiation hardness, silicon has been chosen as active material for the regions exposed to higher radiation levels. The silicon sensors are fabricated as 20 cm (8”) wide hexagonal wafers and are segmented into several hundred pads which are read out individually. As part of the sensor qualification strategy, 8” sensor irradiation with neutrons has been conducted at the Rhode Island Nuclear Science Center (RINSC) and followed by their electrical characterisation in 2020-21. The completion of this important milestone in the CE's R&D program is documented in this paper and it provides detailed account of the associated infrastructure and procedures.The results on the electrical properties of the irradiated CE silicon sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Identification in the ACCESS Mission

ACCESS (Assembly Concept for Construction of Erectable Space Structures) is a planned Space Station mission to measure the elemental energy spectra of Galactic cosmic rays at energies above 100 GeV/nuc. ACCESS consists of a transition radiation detector (TRD) mounted on top of an ionization calorimeter (IC). A silicon matrix detector placed on top of the IC determines the elemental identity of each cosmic ray measured by the IC. The silicon matrix must be designed to identify each cosmic ray in the presence of backscatter from the calorimeter. Because the TRD is mounted above the IC, the matrix must also recognize cosmic rays that have interacted within the TRD before reaching the IC. We will report the results of detailed GEANT simulations of the silicon matrix in ACCESS. Results will be presented on backscatter interference with charge identification and the ability of the matrix to recognize cosmic rays that interacted in the TRD.

Wang, J. Z.↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the CMS electromagnetic calorimeter in pp collisions at √$_{s}$ = 13 TeV

The operation and performance of the Compact Muon Solenoid(CMS) electromagnetic calorimeter (ECAL) are presented, based ondata collected in pp collisions at√$_{s}$ =13 TeV at the CERN LHC, in the years from 2015 to 2018(LHC Run 2), corresponding to an integrated luminosity of151 fb$^{-1}$. The CMS ECAL is a scintillating lead-tungstatecrystal calorimeter, with a silicon strip preshower detector in theforward region that provides precise measurements of the energy andthe time-of-arrival of electrons and photons. The successfuloperation of the ECAL is crucial for a broad range of physics goals,ranging from observing the Higgs boson and measuring its properties,to other standard model measurements and searches for newphenomena. Precise calibration, alignment, and monitoring of theECAL response are important ingredients to achieve these goals. Toface the challenges posed by the higher luminosity, whichcharacterized the operation of the LHC in Run 2, the proceduresestablished during the 2011–2012 run of the LHC have been revisitedand new methods have been developed for the energy measurement andfor the ECAL calibration. The energy resolution of the calorimeter,for electrons from Z boson decays reaching theECAL without significant loss of energy by bremsstrahlung, wasbetter than 1.8%, 3.0%, and 4.5% in the |η| intervals[0.0,0.8], [0.8,1.5], [1.5, 2.5], respectively. This resultingperformance is similar to that achieved during Run 1 in 2011–2012,in spite of the more severe running conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis on H Spectral Shape During the Early 2012 SEPs with the PAMELA Experiment

The satellite-borne PAMELA experiment has been continuously collecting data since 2006.This apparatus is designed to study charged particles in the cosmic radiation. The combination of a permanent magnet, a silicon strip tracker and a silicon-tungsten imaging calorimeter, and the redundancy of instrumentation allow very precise studies on the physics of cosmic rays in a wide energy range and with high statistics. This makes PAMELA a very suitable instrument for Solar Energetic Particle (SEP) observations. Not only does its pan the energy range between the ground-based neutron monitor data and the observations of SEPs from space,but PAMELA also carries out the first direct measurements of the composition for the highest energy SEP events, including those causing Ground Level Enhancements (GLEs).In particular, PAMELA has registered many SEP events during solar cycle 24,offering unique opportunities to address the question of high-energy SEP origin. A preliminary analysis on proton spectra behaviour during this event is presented in this work.

Protons↗

Design and Performance of the Astro-E/XRS Microcalorimeter Array and Anti-Coincidence Detector

The XRS instrument has an array of 32 micro-calorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of 9 eV at 3 keV and 11 eV at 6 keV. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, operating temperature, thermistor size, absorber choice, and means of attaching the absorber to the thermistor bearing element. We will present representative performance data, though a more detailed presentation of the results of the instrument calibration is presented elsewhere in these proceedings. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance in conjunction with the array.

Stahle, C. K.↗

The Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anti-Coincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS has a square array of 36 microcalorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance.

x-ray calorimeter↗

Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anticoincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) soft x-ray spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS had a square array of 36 x-ray calorimeters at the focal plane. These calorimeters consisted of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector was located behind the calorimeter array and served to reject events due to cosmic rays. We will briefly describe this anticoincidence detector and its performance.

Kilbourne, Caroline A.↗