SEARCH · Engineering Papers
Results for “Silicon Detector”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Development of the ORRUBA Silicon Detector Array
High quality radioactive beams have recently made possible the measurement of (d,p) reactions on unstable nuclei in inverse kinematics, which can yield information on the development of single-neutron structure away from stability, and are of astrophysical interest due to the proximity to suggested r-process paths. The Oak Ridge Rutgers University Barrel Array (ORRUBA) is a new high solid-angular coverage array, composed of two rings of silicon detectors, optimized for measuring (d,p) reactions. A partial implementation has been used to measure (d,p) reactions on nuclei around the N = 82 shell closure.
Initial assessment of multilayer silicon detectors for hard X-ray imaging
Silicon detectors with lower material budget, ultrafast readout and radiation hardness are under developments. These unique features make pixelized silicon sensors a good option for hard X-ray imaging. To verify the performance of spatial resolution and energy sensitivity of silicon sensors to hard X-rays, a two layer setup of Pixelink PL-D725MU sensors has been tested at the Argonne National Laboratory Advanced Photon Source (APS) ID-10 sector with 29.2 keV high photon flux (4.5 x 10(8) to 4.5 x 10(10) photons per second) X-rays. Better than 3 mu m spatial resolution and clear energy characterization have been achieved by both layers. Commercial CMOS sensors with superior spatial resolution could be used for phase contrast imaging in current synchrotrons. These studies pave the path for future multilayer ultrafast silicon sensor development with ns to sub-ns readout speeds in hard X-ray imaging at synchrotrons and XFEL beamlines.
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
Dark Matter Search Results Using Silicon Detectors of CDMS II journal article to be submitted to Physicial Review Letters
Role of energy partitioning on electron-hole recombination, trapping, and detection in silicon detectors
The dynamics of electron-hole pair creation and transport in a semiconductor control the fundamental signal response for radiation detection. Extensive studies on silicon detectors have led to contradictory interpretations on the origins of the pulse height defect (PHD) and nonlinear response. In this study, recombination and trapping behaviors of a controlled number of electron-hole pairs produced within different volumes along the ion path are investigated, and the pulse height generated is analyzed in terms of energy partitioning. The results clearly demonstrate that a high recombination rate is not observed for heavy ions; moreover, significant trapping associated with the atomic defects produced by individual ions is responsible for the nonlinear response at low energies and PHD at high energies.
Silicon Detector Results from the First Five-Tower Run of CDMSII
Silicon Detector Results from the First Five-Tower Run of CDMSII
Sub-micron resolution of localized ion beam induced charge reduction in silicon detectors damaged by heavy ions
In this study, displacement damage reduces ion beam induced charge (IBIC) through Shockley-Read-Hall recombination. Closely spaced pulses of 200 keV Si ++ ions focused in a 40 nm beam spot are used to create damage cascades within 0.25 μm 2 areas. Damaged areas are detected through contrast in IBIC signals generated with focused ion beams of 200 keV Si ++ ions and 60 keV Li + ions. IBIC signal reduction can be resolved over sub-micron regions of a silicon detector damaged by as few as 1000 heavy ions.
Silicon detector R&D for the future Electron-Ion Collider
Explore the source record for details and available documents.
Test of Ultra Fast Silicon Detectors for picosecond time measurements with a new multipurpose read-out board
Not provided.
Operational experience with the CDF Run II Silicon Detector
The CDF Run II Silicon Detector is the largest operating silicon detector in High Energy Physics. Its 722,000 channels spread over 7 m{sup 2} of silicon micro-strip sensors allow precision tracking and vertexing. The CDF silicon detector played a critical role in the discovery of B{sub s} mixing and is used extensively for the current Higgs Boson searches. Over the last 7 years, the detector efficiency has remained stable at 95% after the Run II commissioning period. The infrastructure (cooling, power supplies) problems dealt with are discussed.
Performance of position-sensitive resistive silicon detectors in the Forward Array Using Silicon Technology (FAUST)
The silicon telescopes of the Forward Array Using Silicon Technology (FAUST) have been recently upgraded with silicon detectors which use resistive charge-splitting to measure the position of charged particles. This is in addition to the measurement of the total energy that these charged particles deposit in the detector. The upgrade results in increased angular resolution with a much smaller number of signals than silicon strip detectors with similar resolution. Here, a novel method of calibration has been used to demonstrate the efficacy of these position-sensitive detectors, and the detectors have been used in a commissioning experiment.
A micron resolution optical scanner for characterization of silicon detectors
The emergence of high position resolution (∼10 μm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 μm at 1 − σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 μm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper.
Characterization of the Cherenkov Photon Background for Low-noise Silicon Detectors in Space
Future space observatories that seek to perform imaging and spectroscopy of faint astronomical sources will require ultra-low-noise detectors that are sensitive over a broad wavelength range. Silicon charge-coupled devices (CCDs), such as EMCCDs, skipper CCDs, multi-amplifier sensing CCDs, and single-electron sensitive read out CCDs have demonstrated the ability to detect and measure single photons from X-ray energies to near the silicon band gap (∼1.1 μm), making them candidate technologies for this application. Here, in this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic cosmic rays traversing a silicon detector. We present a model for Cherenkov photon production and absorption that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low-noise silicon detectors in space. We study how the Cherenkov background rate depends on detector thickness, variations in solar activity, and the contribution of heavy cosmic ray species (Z > 2). We find that for thick silicon detectors, such as those required to achieve high quantum efficiency at long wavelengths, the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds. We apply our Cherenkov background model to simulated spectroscopic observations of extra-solar planets, and we find that thick detectors continue to outperform their thinner counterparts at longer wavelengths despite a larger Cherenkov background rate. Furthermore, we find that minimal masking of cosmic-ray tracks continues to maximize the signal-to-noise ratio of very faint sources despite the existence of extended halos of Cherenkov photons.
Overview of Silicon Detectors in STAR: Present and Future
The STAR experiment at RHIC aims to study the QCD phase transition and the origin of the spin of the proton. Its main detector for charged particle track reconstruction is a Time Projection Chamber, which has been supplemented with a silicon detector involving two different technologies, in particular double-sided silicon strip and silicon drift technology. STAR is preparing now for a new Silicon Vertex Detector, using double-sided silicon strip, single-sided silicon strip-pads, and CMOS monolithic active pixel sensors technology, planned to take data in 2014. We give an overview of the design, calibration and performances of the silicon detectors used by the STAR experiment in the past and the expected performances of the future silicon detector upgrade.
Angular independent silicon detector for dosimetry in external beam radiotherapy
Purpose: In this work, the “edgeless” silicon detector technology is investigated, in combination with an innovative packaging solution, to manufacture silicon detectors with negligible angular response. The new diode is also characterized as a dosimeter for radiotherapy with the aim to verify its suitability as a single detector for in vivo dosimetry as well as large area 2D array that does not require angular correction to their response. Methods: For the characterisation of the “edgeless-drop-in” detector technology, a set of samples have been manufactured with different sensitive areas (1 × 1 and 0.5 × 0.5 mm{sup 2}) and different thicknesses (0.1 and 0.5 mm) in four different combinations of top and peripheral p–n junction fabricated on p-type and n-type silicon substrates. The diode probes were tested in terms of percentage depth dose (PDD), dose rate, and linearity and compared to ion chambers. Measurements of the output factor have been compared to film. The angular response of the diodes probes has been tested in a cylindrical PMMA phantom, rotated with bidirectional accuracy of 0.25° under 10 × 10 cm{sup 2} 6 MV Linac photon beam. The radiation hardness has been investigated as well as the effect of radiation damage on the angular and dose rate response of the diode probes when irradiated with photons from a Co-60 gamma source up to dose of 40 kGy. Results: The PDDs measured by the edgeless detectors show an agreement with the data obtained using ion chambers within ±2%. The output factor measured with the smallest area edgeless diodes (0.5 × 0.5 mm{sup 2}—0.1 and 0.5 mm thick) matches EBT3 film to within 2% for square field size from 10 to 0.5 cm side equivalent distance. The dose rate dependence in a dose per pulse range of 0.9 × 10{sup −5}–2.7 × 10{sup −4} Gy/pulse was less than −7% and +300% for diodes fabricated on p-type and n-type substrates, respectively. The edgeless diodes fabricated on the p-type substrate demonstrated degradation of the response as a function of the irradiation dose within 5%–15%, while diodes on the n-type substrate show a variation of approximately 30% after 40 kGy. The angular response of all probes is minimal (within 2%) but the N on N and P on P configurations show the best performances with an angular dependence of ±1.0% between 0° and 180° in the transversal direction. In this configuration, the space charge region of the passive diode extends from the behind and sidewall toward the anode on the top providing beneficial electric field distribution in the peripheral area of the diode. Such performance has also been tested after irradiation by Co-60 up to 40 kGy with no measurable change in angular response. Conclusions: A new edgeless-drop-in silicon diode fabrication and packaging technology has been used to develop detectors that show no significant angular dependence in their response for dosimetry in radiation therapy. From the characterisation of the diodes, proposed in a wide range of different geometries and configurations, the authors recommend the P-on-P detectors in conjunction with “drop in” packaging technology as the candidate for further development as single diode probe or 2D diode array for dosimetry in radiotherapy.
Cherenkov photon background for low-noise silicon detectors in space
Future space observatories dedicated to direct imaging and spectroscopy of extra-solar planets will require ultra-low-noise detectors that are sensitive over a broad range of wavelengths. Silicon charge-coupled devices (CCDs), such as EMCCDs, Skipper CCDs, and Multi-Amplifier Sensing CCDs, have demonstrated the ability to detect and measure single photons from ultra-violet to near-infrared wavelengths, making them candidate technologies for this application. In this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic charged particles traversing a silicon detector. In the intense radiation environment of space, energetic cosmic rays produce high-energy tracks and more extended halos of low-energy Cherenkov photons, which are detectable with ultra-low-noise detectors. We present a model of this effect that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low noise silicon detectors in space. We find that the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds that have previously been considered.
Silicon detectors for monitoring neutron beams in n-TOF beamlines
During 2014, the second experimental area (EAR2) was completed at the n-TOF neutron beam facility at CERN (n-TOF indicates neutron beam measurements by means of time of flight technique). The neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target. The resulting neutron beam covers the energy range from thermal to several GeV. In this paper, we describe two beam diagnostic devices, both exploiting silicon detectors coupled with neutron converter foils containing {sup 6}Li. The first one is based on four silicon pads and allows monitoring of the neutron beam flux as a function of the neutron energy. The second one, in beam and based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely, a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices were characterized with radioactive sources and also tested at the n-TOF facility at CERN. The wide energy and intensity range they proved capable of sustaining made them attractive and suitable to be used in both EAR1 and EAR2 n-TOF experimental areas, where they became immediately operational.