Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SiB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mysterious SiB 3 : Identifying the Relation between α- and β-SiB 3

Binary silicon boride SiB 3 has been reported to occur in two forms, as disordered and nonstoichiometric α-SiB 3–x , which relates to the α-rhombohedral phase of boron, and as strictly ordered and stoichiometric β-SiB 3 . Similar to other boron-rich icosahedral solids, these SiB 3 phases represent potentially interesting refractory materials. However, their thermal stability, formation conditions, and thermodynamic relation are poorly understood. Here, we map the formation conditions of α-SiB 3–x and β-SiB 3 and analyze their relative thermodynamic stabilities. α-SiB 3–x is metastable (with respect to β-SiB 3 and Si), and its formation is kinetically driven. Pure polycrystalline bulk samples may be obtained within hours when heating stoichiometric mixtures of elemental silicon and boron at temperatures 1200–1300 °C. At the same time, α-SiB 3–x decomposes into SiB6 and Si, and optimum time-temperature synthesis conditions represent a trade-off between rates of formation and decomposition. The formation of stable β-SiB 3 was observed after prolonged treatment (days to weeks) of elemental mixtures with ratios Si/B = 1:1–1:4 at temperatures 1175–1200 °C. The application of high pressures greatly improves the kinetics of SiB 3 formation and allows decoupling of SiB 3 formation from decomposition. Quantitative formation of β-SiB 3 was seen at 1100 °C for samples pressurized to 5.5–8 GPa. β-SiB 3 decomposes peritectoidally at temperatures between 1250 and 1300 °C. The highly ordered nature of β-SiB 3 is reflected in its Raman spectrum, which features narrow and distinct lines. In contrast, the Raman spectrum of α-SiB 3–x is characterized by broad bands, which show a clear relation to the vibrational modes of isostructural, ordered B 6 P. The detailed composition and structural properties of disordered α-SiB 3–x were ascertained by a combination of single-crystal X-ray diffraction and 29 Si magic angle spinning NMR experiments. Notably, the compositions of polycrystalline bulk samples (obtained at T ≤ 1200 °C) and single crystal samples (obtained from Si-rich molten Si–B mixtures at T > 1400 °C) are different, SiB 2.93(7) and SiB 2.64(2) , respectively. The incorporation of Si in the polar position of B 12 icosahedra results in highly strained cluster units. This disorder feature was accounted for in the refined crystal structure model by splitting the polar position into three sites. The electron-precise composition of α-SiB 3–x is SiB 2.5 and corresponds to the incorporation of, on average, two Si atoms in each B 12 icosahedron. Accordingly, α-SiB 3–x constitutes a mixture of B 10 Si 2 and B 11 Si clusters. The structural and phase stability of α-SiB 3–x were explored using a first-principles cluster expansion. The most stable composition at 0 K is SiB 2.5 , which however is unstable with respect to the decomposition β-SiB 3 + Si. Modeling of the configurational and vibrational entropies suggests that α-SiB 3–x only becomes more stable than β-SiB 3 at temperatures above its decomposition into SiB 6 and Si. Hence, we conclude that α-SiB 3–x is metastable at all temperatures. Density functional theory electronic structure calculations yield band gaps of similar size for electron-precise α-SiB 2.5 and β-SiB 3 , whereas α-SiB 3 represents a p-type conductor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic and structural properties of ferromagnetic Fe{sub 5}PB{sub 2} and Fe{sub 5}SiB{sub 2} and effects of Co and Mn substitutions

Crystallographic and magnetic properties of Fe{sub 5}PB{sub 2}, Fe{sub 4}CoPB{sub 2}, Fe{sub 4}MnPB{sub 2}, Fe{sub 5}SiB{sub 2}, Fe{sub 4}CoSiB{sub 2}, and Fe{sub 4}MnSiB{sub 2} are reported. All adopt the tetragonal Cr{sub 5}B{sub 3} structure-type and are ferromagnetic at room temperature with easy axis of magnetization along the c-axis. The spin reorientation in Fe{sub 5}SiB{sub 2} is observed as an anomaly in the magnetization near 170 K and is suppressed by substitution of Co or Mn for Fe. The silicides are found to generally have larger magnetic moments than the phosphides, but the data suggest smaller magnetic anisotropy in the silicides. Cobalt substitution reduces the Curie temperatures by more than 100 K and ordered magnetic moments by 16%–20%, while manganese substitution has a much smaller effect. This suggests Mn moments align ferromagnetically with the Fe and that Co does not have an ordered moment in these structures. Anisotropic thermal expansion is observed in Fe{sub 5}PB{sub 2} and Fe{sub 5}SiB{sub 2}, with negative thermal expansion seen along the c-axis of Fe{sub 5}SiB{sub 2}. First principles calculations of the magnetic properties of Fe{sub 5}SiB{sub 2} and Fe{sub 4}MnSiB{sub 2} are reported. The results, including the magnetic moment and anisotropy, are in good agreement with experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessing the feasibility of volumetric-modulated arc therapy using simultaneous integrated boost (SIB-VMAT): An analysis for complex head-neck, high-risk prostate and rectal cancer cases

Intensity-modulated radiotherapy (IMRT) allowed the simultaneous delivery of different doses to different target volumes within a single fraction, an approach called simultaneous integrated boost (SIB). As consequence, the fraction dose to the boost volume can be increased while keeping low doses to the elective volumes, and the number of fractions and overall treatment time will be reduced, translating into better radiobiological effectiveness. In recent years, volumetric-modulated arc therapy (VMAT) has been shown to provide similar plan quality with respect to fixed-field IMRT but with large reduction in treatment time and monitor units (MUs) number. However, the feasibility of VMAT when used with SIB strategy has few investigations to date. We explored the potential of VMAT in a SIB strategy for complex cancer sites. A total of 15 patients were selected, including 5 head-and-neck, 5 high-risk prostate, and 5 rectal cancer cases. Both a double-arc VMAT and a 7-field IMRT plan were generated for each case using Oncentra MasterPlan treatment planning system for an Elekta Precise linac. Dosimetric indexes for targets and organs at risk (OARs) were compared based on dose-volume histograms. Conformity index, homogeneity index, and dose-contrast index were used for target analyses. The equivalent uniform doses and the normal tissue complication probabilities were calculated for main OARs. MUs number and treatment time were analyzed to score treatment efficiency. Pretreatment dosimetry was performed using 2-dimensional (2D)-array dosimeter. SIB-VMAT plans showed a high level of fluence modulation needed for SIB treatments, high conformal dose distribution, similar target coverage, and a tendency to improve OARs sparing compared with the benchmark SIB-IMRT plans. The median treatment times reduced from 13 to 20 minutes to approximately 5 minutes for all cases with SIB-VMAT, with a MUs reduction up to 22.5%. The 2D-array ion-chambers' measurements reported an agreement of more than 95% for a criterion of 3% to 3 mm. SIB-VMAT was able to combine the advantages of conventional SIB-IMRT with its highly conformal dose distribution and OARs sparing and the advantages of 3D-conformal radiotherapy with its fast delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Space‐Plant versus Sward‐Plot Evaluation of Half‐Sib Families to Select Parents for Synthetic Cultivars with Superior Biomass Yield in Lowland Switchgrass

ABSTRACT Switchgrass ( Panicum virgatum L.) needs significant biomass yield improvement for its viable use as bioenergy feedstock. Conventional family evaluation under sward plot is very effective in cultivar improvement, but it is time and resource consuming. Family evaluation under space planting using honeycomb design can reduce time and inputs. The objective of this study was to compare conventional sward‐plot and modified space‐plant evaluation of half‐sib families in their biomass yield gain and resource use. Using same initial set of genotypes selected from ‘Alamo’, two experimental synthetics were developed by the following methods: (i) summer field polycrossing of selected genotypes to produce half‐sibs, half‐sib family evaluation under sward plot conditions (HSSward) at two locations for 2 yr, and polycrossing the five genotypes showing superior half‐sibs to produce the experimental and (ii) greenhouse polycrossing genotypes during the winter to produce half‐sibs, half‐sib family evaluation under space‐plant conditions using honeycomb design (HSSpace) for 2 yr at one location, and polycrossing the five best progeny within the five superior half‐sibs to produce the experimental. The 2 to 3 yr biomass yield performance of two experimentals across five locations demonstrated that both HSSward and HSSpace led to a significant biomass yield gain over Alamo in three and two of the five locations, respectively. The HSSward produced a superior and more stable synthetic across a wide region than HSSpace. However, the HSSpace produced its synthetic a year sooner and was more resource efficient and, under finite resources, it could be a method of choice for cultivar development especially for a narrow geographic region.

Bhandari, H. S.↗

A dosimetric comparison of 3D-CRT, IMRT, and static tomotherapy with an SIB for large and small breast volumes

Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. All patients were prescribed a dose of 45 Gy in 20 fractions to the breast with an SIB of 56 Gy in 20 fractions to the tumor bed and normalized so that D{sub 98%} > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D{sub 98%} > 95% and D{sub 2%} < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTV{sub boost} {sub eval} (0.079 ± 0.011) and breast minus the SIB volume (Breast{sub SIB}) (p < 0.001, 0.15 ± 0.03) compared with the PTV{sub boost} {sub eval} (0.085 ± 0.008, 0.088 ± 0.12) and Breast{sub SIB} (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11 Gy compared with 7.75 ± 2.54 Gy and 8.29 ± 2.76 Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26 Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44 Gy and 3.91 ± 1.58 Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D-CRT in both PTV dose conformity and reduction of mean doses to the ipsilateral lung.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-451: Hybrid-VMAT: A Novel Technique Combining VMAT and 3D in Planning Whole Breast Radiotherapy with a Simultaneously-Integrated Boost (WBRT+SIB)

Purpose: The RTOG 1005 trial offered a hypofractionated arm in delivering WBRT+SIB. Traditionally, treatments were planned at our institution using field-in-field (FiF) tangents with a concurrent 3D conformal boost. With the availability of VMAT, it is possible that a hybrid VMAT-3D planning technique could provide another avenue in treating WBRT+SIB. Methods: A retrospective study of nine patients previously treated using RTOG 1005 guidelines was performed to compare FiF+3D plans with the hybrid technique. A combination of static tangents and partial VMAT arcs were used in base-dose optimization. The hybrid plans were optimized to deliver 4005cGy to the breast PTVeval and 4800cGy to the lumpectomy PTVeval over 15 fractions. Plans were optimized to meet the planning goals dictated by RTOG 1005. Results: Hybrid plans yielded similar coverage of breast and lumpectomy PTVs (average D95 of 4013cGy compared to 3990cGy for conventional), while reducing the volume of high dose within the breast; the average D30 and D50 for the hybrid technique were 4517cGy and 4288cGy, compared to 4704cGy and 4377cGy for conventional planning. Hybrid plans increased conformity as well, yielding CI95% values of 1.22 and 1.54 for breast and lumpectomy PTVeval volumes; in contrast, conventional plans averaged 1.49 and 2.27, respectively. The nearby organs at risk (OARs) received more low dose with the hybrid plans due to low dose spray from the partial arcs, but all hybrid plans did meet the acceptable constraints, at a minimum, from the protocol. Treatment planning time was also reduced, as plans were inversely optimized (VMAT) rather than forward optimized. Conclusion: Hybrid-VMAT could be a solution in delivering WB+SIB, as plans yield very conformal treatment plans and maintain clinical standards in OAR sparing. For treating breast cancer patients with a simultaneously-integrated boost, Hybrid-VMAT offers superiority in dosimetric conformity and planning time as compared to FIF techniques.

60 APPLIED LIFE SCIENCES↗

Magnetic, Magnetocaloric Properties, and Phenomenological Model in Amorphous Ni{sub 80−x}Fe{sub x}(SiB){sub 20} Alloys with (x = 0, 2.4, 8, and 16)

Amorphous Ni{sub 80−x}Fe{sub x}(SiB){sub 20} ribbons with different Fe concentrations (0 ≤ x ≤ 16) were fabricated by melt spinning technique, and their magnetic and magnetocaloric properties were investigated and a phenomenological model was also applied. The Curie temperature (T{sub C}), magnetic moment of transition metal and maximum magnetic entropy change (− ΔS{sub M}) increase with increasing Fe content. At a magnetic field change of 2 T, the (− ΔS{sub M}) and relative cooling power (RCP) show the highest values of 0.53 J/kg K and 85 J kg{sup −1} respectively for Fe{sub 16}Ni{sub 64}(SiB){sub 20} alloys. In addition, a satisfactory agreement between the experimental and Hamad’s phenomenological model is reported.

36 MATERIALS SCIENCE↗

Magnetostructural transition in Fe{sub 5}SiB{sub 2} observed with neutron diffraction

The crystal and magnetic structure of Fe{sub 5}SiB{sub 2} has been studied by a combination of X-ray and neutron diffraction. Also, the magnetocrystalline anisotropy energy constant has been estimated from magnetisation measurements. High quality samples have been prepared using high temperature synthesis and subsequent heat treatment protocols. The crystal structure is tetragonal within the space group I4/mcm and the compound behaves ferromagnetically with a Curie temperature of 760 K. At 172 K a spin reorientation occurs in the compound and the magnetic moments go from aligning along the c-axis (high T) down to the ab-plane (low T). The magnetocrystalline anisotropy energy constant has been estimated to 0.3 MJ/m{sup 3} at 300 K. - Highlights: • The crystal and magnetic structure of Fe{sub 5}SiB{sub 2} has been studied by diffraction. • At 172 K a spin reorientation occurs in the compound. • The magnetic moments are aligned along the c-axis at high T. • The magnetic moments are aligned in the ab-plane at low T. • The magnetocrystalline anisotropy energy constant has been estimated to 0.3 MJ/m{sup 3}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Energy Electronic Transition in SiB Rings

Five- and six-membered rings containing Si–B bonds were synthesized by salt metathesis of magnesium disilanides with tetramethylpiperidinyldichloroborane (TMPBCl 2 ). Materials were characterized by 1 H, 11 B, 13 C, and 29 Si NMR spectroscopy, as well as X-ray crystallography. Insights from crystallography facilitate conformational analysis of the cyclosilanes and elucidation of conformation-dependent optical properties. Furthermore, crystallography supports assignment of π character to the BN bond of the tetramethylpiperidinylborane fragment. The SiB rings possess unique optical properties compared to all silicon rings. A 350 nm electronic transition only observed in SiB rings is assigned to a σ–π* transition on the basis of density functional theory calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-AB-204-03: A Novel 3D Printed Phantom for 4D PET/CT Imaging and SIB Radiotherapy Verification

Purpose: To construct and test a 3D printed phantom designed to mimic variable PET tracer uptake seen in lung tumor volumes. To assess segmentation accuracy of sub-volumes of the phantom following 4D PET/CT scanning with ideal and patient-specific respiratory motion. To plan, deliver and verify delivery of PET-driven, gated, simultaneous integrated boost (SIB) radiotherapy plans. Methods: A set of phantoms and inserts were designed and manufactured for a realistic representation of lung cancer gated radiotherapy steps from 4D PET/CT scanning to dose delivery. A cylindrical phantom (40x 120 mm) holds inserts for PET/CT scanning. The novel 3D printed insert dedicated to 4D PET/CT mimics high PET tracer uptake in the core and lower uptake in the periphery. This insert is a variable density porous cylinder (22.12×70 mm), ABS-P430 thermoplastic, 3D printed by uPrint SE Plus with inner void volume (5.5×42 mm). The square pores (1.8×1.8 mm2 each) fill 50% of outer volume, resulting in a 2:1 SUV ratio of PET-tracer in the void volume with respect to porous volume. A matching in size cylindrical phantom is dedicated to validate gated radiotherapy. It contains eight peripheral holes matching the location of the porous part of the 3D printed insert, and one central hole. These holes accommodate adaptors for Farmer-type ion chamber and cells vials. Results: End-to-end test were performed from 4D PET/CT scanning to transferring data to the planning system and target volume delineation. 4D PET/CT scans were acquired of the phantom with different respiratory motion patterns and gating windows. A measured 2:1 18F-FDG SUV ratio between inner void and outer volume matched the 3D printed design. Conclusion: The novel 3D printed phantom mimics variable PET tracer uptake typical of tumors. Obtained 4D PET/CT scans are suitable for segmentation, treatment planning and delivery in SIB gated treatments of NSCLC.

60 APPLIED LIFE SCIENCES↗

Effects of Ti, Zr, and Hf on the Phase Stability of Mo-Mo 3 Si+Mo 5 SiB 2 Alloys at 1600 C

Understanding the stability of the three-phase Mo{_}+Mo{sub 3}Si+Mo{sub 5}SiB{sub 2} region is important for alloy design of Mo-Si-B-based refractory metal intermetallic composites. In this work, thermodynamic modeling is coupled with guided experiments to study phase stability in this three-phase region of the Mo-Si-B-X (X = Ti, Zr, Hf) system. Both the calculated and experimental results show that additions of Zr and Hf limit significantly the stability of the three-phase region because of the formation of the ternary phases MoSiZr and MoSiHf, while Ti addition leads to a much larger region of stability for the three-phase equilibrium.

36 MATERIALS SCIENCE↗

MO-G-201-01: A Multi-Institutional Study Investigating the Performance of a Knowledge-Based Planning System Against Pinnacle Auto-Planning Engine in SIB-IMRT for the Head-And-Neck Cancer

Purpose: Knowledge-based Planning (KBP) founded on prior planning experience and Auto-Planning Engine (APE; commercialized in Pinnacle v9.10 TPS) based on progressive optimization algorithm both aim to eliminate the trial-and-error process in radiotherapy inverse planning. This study investigates the performance of the approaches in a multi-institutional setting to evaluate their functionalities in oropharyngeal cancer and offers suggestions how they can be implemented in the clinic. Methods: Radboud University Medical Center (RUMC) provided 35 oropharyngeal cancer patients (SIB-IMRT with two-dose-level prescription: 68 Gy to PTV68 and 50.3 Gy to PTV50.3) with corresponding comparative APE plans. Johns Hopkins University (JHU) contributed to a three-dose-level (70 Gy 63 Gy and 58.1 Gy) plan library for RUMC’s patient KBP generation. MedStar Georgetown University Hospital (MGUH) contributed to a KBP approach employing overlap-volume histogram (OVH-KBP) for generating RUMC’s patient KBP plans using JHU’s plan library. Since both approaches need their own user-defined parameters as initial inputs the first 10 patients were set aside as training set to finalize them. Meanwhile cross-institutional comparisons and adjustments were implemented for investigating institutions’ protocol discrepancies and the approaches’ user-defined parameters were updated accordingly. The finalized parameters were then applied to the remaining 25 patients for OVH-KBP and APE generation. A Wilcoxon rank-sum test was used for statistical comparison with significance level of p<0.05. Results: On average PTV68’s V95 was 96.5% in APE plans vs. 97% in OVH-KBP plans (p=0.36); PTV50.3’s V95 in APE plans was 97.8% vs.97.6% in OVH-KBP plans (p=0.6); cord’s D0.1 cc was 38.6 Gy in OVH-KBP plans vs. 43.7 Gy in APE plans (p=0.0001); mean doses to larynxes oral cavities parotids and submandibular glands were similar with p>0.2. Conclusions: The study demonstrates that KBP and APE can generate plans of comparable quality in a multi-institutional setting. Variations in clinical protocols can be effectively addressed for cross-institutional adaptations. Binbin Wu and Todd McNutt are the co-inventors of a patent associated with the proposed knowledge-based planning system which was licensed to Varian Medical Systems in 2015; This research was in part supported by Philips Radiation Oncology Systems.

60 APPLIED LIFE SCIENCES↗

BLUP and mean yields of selected top 25 high yielding half-sib families

BLUP and mean yields of selected top 25 high yielding half-sib families. The yield BLUP were estimated using mixed linear models. The family column indicates the families with progeny column showing the corresponding progenies to selected families. ‘Wat’ here has been used to denote Watkinsville, ‘Tif’ for Tifton and ‘TN’ for Tennessee.

09 BIOMASS FUELS↗

Materials Data on SiB by Materials Project

BSi is Wurtzite structured and crystallizes in the hexagonal P6_3mc space group. The structure is three-dimensional. B is bonded to four equivalent Si atoms to form corner-sharing BSi4 tetrahedra. There are one shorter (1.99 Å) and three longer (2.06 Å) B–Si bond lengths. Si is bonded to four equivalent B atoms to form corner-sharing SiB4 tetrahedra.

36 MATERIALS SCIENCE↗

Materials Data on Nb10(SiB)3 by Materials Project

Nb10(BSi)3 crystallizes in the orthorhombic Fmm2 space group. The structure is three-dimensional. there are four inequivalent Nb+2.10+ sites. In the first Nb+2.10+ site, Nb+2.10+ is bonded to two B3- and three Si4- atoms to form NbSi3B2 trigonal bipyramids that share corners with four equivalent NbSi3B3 octahedra, corners with twelve NbSi3B2 trigonal bipyramids, edges with seven NbSi3B2 trigonal bipyramids, faces with two equivalent NbSi3B3 octahedra, and a faceface with one NbSi3B2 trigonal bipyramid. The corner-sharing octahedra tilt angles range from 42–62°. There are one shorter (2.51 Å) and one longer (2.53 Å) Nb–B bond lengths. There are a spread of Nb–Si bond distances ranging from 2.54–2.69 Å. In the second Nb+2.10+ site, Nb+2.10+ is bonded to three B3- and two equivalent Si4- atoms to form NbSi2B3 trigonal bipyramids that share corners with four equivalent NbSi3B3 octahedra, corners with twelve NbSi3B2 trigonal bipyramids, edges with seven NbSi3B2 trigonal bipyramids, faces with two equivalent NbSi3B3 octahedra, and a faceface with one NbSi2B3 trigonal bipyramid. The corner-sharing octahedra tilt angles range from 42–60°. There are two shorter (2.44 Å) and one longer (2.49 Å) Nb–B bond lengths. Both Nb–Si bond lengths are 2.69 Å. In the third Nb+2.10+ site, Nb+2.10+ is bonded to two equivalent B3- and three Si4- atoms to form NbSi3B2 trigonal bipyramids that share corners with four equivalent NbSi3B3 octahedra, corners with twelve NbSi3B2 trigonal bipyramids, edges with seven NbSi3B2 trigonal bipyramids, faces with two equivalent NbSi3B3 octahedra, and a faceface with one NbSi3B2 trigonal bipyramid. The corner-sharing octahedra tilt angles range from 44–63°. Both Nb–B bond lengths are 2.44 Å. There are one shorter (2.61 Å) and two longer (2.72 Å) Nb–Si bond lengths. In the fourth Nb+2.10+ site, Nb+2.10+ is bonded to three B3- and three Si4- atoms to form distorted NbSi3B3 octahedra that share corners with six equivalent NbSi3B3 octahedra, corners with sixteen NbSi3B2 trigonal bipyramids, and faces with eight NbSi3B2 trigonal bipyramids. The corner-sharing octahedra tilt angles range from 2–56°. There are a spread of Nb–B bond distances ranging from 2.48–2.57 Å. There are one shorter (2.57 Å) and two longer (2.94 Å) Nb–Si bond lengths. There are two inequivalent B3- sites. In the first B3- site, B3- is bonded in a 9-coordinate geometry to eight Nb+2.10+ and one B3- atom. The B–B bond length is 2.06 Å. In the second B3- site, B3- is bonded in a 9-coordinate geometry to eight Nb+2.10+ and one Si4- atom. The B–Si bond length is 2.19 Å. There are two inequivalent Si4- sites. In the first Si4- site, Si4- is bonded in a 9-coordinate geometry to eight Nb+2.10+ and one B3- atom. In the second Si4- site, Si4- is bonded in a 10-coordinate geometry to ten Nb+2.10+ atoms.

36 MATERIALS SCIENCE↗

Comparison of whole-field simultaneous integrated boost VMAT and IMRT in the treatment of nasopharyngeal cancer

To study the feasibility of using volumetric-modulated arc therapy (VMAT) to deliver whole-field simultaneous integrated boost (WF-SIB) to treat patients with nasopharyngeal cancer (NPC). WF-SIB intensity-modulated radiotherapy (IMRT) plans, one-arc WF-SIB VMAT plans, and two-arc WF-SIB VMAT plans were generated with identical objective functions for 8 patients with NPC of various stages. Isodose distributions and dose-volume histograms were evaluated. Dosimetric and biological quality indices of clinical target volume (CTV) and organs at risk (OARs) were calculated to study the optimization capability of these 3 modalities in the treatment of patients with NPC. The optimization time, delivery time, required monitor units (MUs), and delivery accuracy were also compared to investigate the feasibility of these 3 modalities. There was no significant difference (p = 0.92) in target coverage (TC) between WF-SIB IMRT (99.00 ± 0.79) and two-arc WF-SIB VMAT (97.98 ± 1.29). However, both had higher TC than one-arc VMAT plans (89.92 ± 6.32, p < 0.01). IMRT demonstrated the best protection of the spinal cord, whereas two-arc VMAT showed the minimum D{sub max} to OARs. No other significant differences were observed among these 3 modalities on CTV coverage and OAR sparing. The delivery and MU efficiency of one-arc and two-arc WF-SIB VMAT were greatly improved compared with WF-SIB IMRT. The optimization time of one-arc and two-arc WF-SIB VMAT plans were 5 and 10 times greater than that of WF-SIB IMRT, respectively. The delivery accuracy of WF-SIB VMAT was not affected by the increased freedom. For patients with NPC, one-arc WF-SIB VMAT might not be able to achieve sufficient TC, whereas two-arc WF-SIB VMAT was able to achieve reasonable TC. No significant advantage on OAR protection was demonstrated by VMAT compared with IMRT. WF-SIB VMAT has significantly shorter delivery times, but WF-SIB IMRT may still be the first treatment choice for patients with NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗