Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Short circuiting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Neutralization Short-Circuiting with Weak Electrolytes Erodes the Efficiency of Bipolar Membranes

Bipolar membranes (BPMs) are critical components of a variety of electrochemical energy technologies. Many electrochemical applications require the use of buffers to maintain stable, nonextreme pH environments, yet the impact of buffers or weak acids/bases on the electrochemical behavior of BPMs remains poorly understood. Here, our data for a cell containing weak electrolytes is consistent with internal pH gradients within the anion exchange membrane (AEM) or cation exchange membrane (CEM) component of the BPM that form via ionic short-circuiting processes at open-circuit. Short-circuiting results from the coupling of co-ion crossover and parasitic neutralization and leads to buffering of the bipolar interface. This phenomenon, which we term neutralization short-circuiting, serves to erode BPM efficiency by attenuating the open-circuit membrane voltage and introducing parasitic reverse bias currents associated with weak acid/base dissociation at the interface. These findings establish a mechanistic basis for the operation of BPM cells in the presence of weak acid/base electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of K-factor on Short Circuit Program Convergence for Inverter-Based Resources during Faults

Classical short-circuit programs that linearize the power network are no longer applicable for inverter based resources (IBRs), necessitating an iterative approach. Phasor domain programs can model the IBRs using an iterative approach considering nonlinear fault responses. In phasor domain models, the IBR can be modeled as a voltage controlled current source (VCCS) in tabular form with positive, negative, and zero sequence information for balanced and unbalance short-circuit faults. In the VCCS modeling of the IBR, positive and negative incremental reactive current, also known as the k-factor, plays an important role in short circuit program convergence. In this work, a few approaches: conventional VCCS modeling with a k-factor of 2, conventional VCCS modeling with a k-factor of 2 with modified pre-fault voltages, VCCS characteristics based on the power flow solution with a k-factor of 2, and VCCS characteristics based on the power flow solution with a k-factor of 1 are investigated for short circuit program convergence under higher IBR penetration. The IEEE 39 bus New England Test System is taken as the test system, and simulations are carried out in PSS®CAPE 15.0.26 simulation software. Simulation results demonstrate that IBR penetration is higher for the VCCS model, which corresponds to the power flow solution with k-factor 1, compared to other approaches.

42 ENGINEERING↗

Quantifying and modeling of stress-driven short-circuits in lithium-ion batteries in electrified vehicles

Despite the huge expansion of electric vehicle sales in the market, customers are discouraged by the possible catastrophic consequences brought by the safety issues of lithium-ion batteries, such as internal short circuits, especially in crash scenarios. Herein, we reveal the quantitative relationship between the deformations of the battery and the internal short circuit. By in situ and ex situ observations and post mortem characterization of the component materials, we quantify the stress-driven internal short circuit and failure behavior of the component material. With the aid of a validated numerical computational model as well as the in situ characterization of the global-field temperature, we successfully identify the minor and major short circuits of the cells upon various mechanical abusive loadings. Finally, we establish the internal short circuit criteria for typical formats of batteries. Furthermore, this discovery also provides a fundamental understanding of both internal and external stress-driven short circuits in a much broader context.

25 ENERGY STORAGE↗

Assessing Inverter-Based Resources Modeling Gaps in Commonly Used Short-Circuit Programs

Future bulk power systems are expected to operate with a high penetration of inverter-based resources (IBR). This is anticipated to fundamentally change the system’s short-circuit behaviors and demand a change in existing transmission line protection settings or schemes. Phasor-domain short circuit programs (e.g., ASPEN, CAPE, and CYME) remain the mainstream tools for developing protection settings. However, the system protection community has shared concerns about the accuracy of IBR models in short-circuit programs. This report compares the performance of existing generic IBR models in short-circuit programs with detailed electro-magnetic transient (EMT) models provided by several different IBR manufacturers in PSCAD, to quantify the short-circuit program’s IBR model accuracy, assess their ability to replicate individual IBR controls such as negative sequence current injections, and identify specific gaps in the existing generic phasor-domain IBR models that are currently available.

42 ENGINEERING↗

Atomic-level mechanisms of short-circuit diffusion in materials

This paper reviews the recent progress in understanding the atomic mechanisms of short-circuit diffusion along materials interfaces, such as grain and interphase boundaries, as well as lattice and interfacial dislocations/disconnections. Recent atomistic computer simulations have shown that short-circuit diffusion is dominated by collective atomic rearrangements in the form of strings and rings of mobile atoms. The process is dynamically heterogeneous in space and time and has many features in common with atomic dynamics in supercooled glass-forming liquids. We discuss examples of grain boundary, interphase boundary, and dislocation diffusion in metals and alloys, including the solute effect on the diffusion rates and mechanisms. Interphase boundaries are exemplified by Al–Si interfaces with diverse orientation relationships and atomic structures. The hierarchy of short-circuit diffusion paths in materials is reviewed by comparing the rates of grain boundary, interphase boundary, and dislocation diffusion. Future directions in the field of short-circuit diffusion in defect core regions are discussed.

36 MATERIALS SCIENCE↗

Theoretical Analysis and Experimental Validation of Flying-Capacitor Multilevel Converters Under Short-Circuit Fault Conditions

Addressing the increasing demand for high- efficiency and high-power-density converters, the flying-capacitor multilevel converter has shown itself as a promising topology. A key advantage of this topology is the reduced voltage rating of the switches, though also makes it vulnerable to device failure during short-circuit conditions. Despite large interest in fault-tolerant operation of these converters, alongside detailed descriptions of flying capacitor balancing, little research has focused on the converter short-circuit fault analysis, which may cause a switch failure if not properly designed for. Therefore, this work presents a comprehensive model describing the large- signal short-circuit switching behavior of a general N -level flying- capacitor multilevel converter. Highly simplified models used to predict the evolution of the switch current and voltage stress during the fault are proposed, targeted at practicing engineers for conservative design guidelines. These models are used to determine the critical time for remedial action of the converter before reaching some predefined maximum conditions. A 2-to-10- level fully-configurable flying-capacitor multilevel converter and a fault circuit hardware prototype are used to experimentally perform different short-circuit tests that show a good match to the measured behavior.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Trapezoidal grid fingers to reduce shadowing loss and improve short circuit current

Traditional metallic contacts on solar cells can cover a substantial portion of the device area, resulting in shadowing of light that diminishes the amount of current collected. In this paper, we developed trapezoidal electron-beam evaporated Ti/Al front grid fingers on GaAs single-junction solar cells to decrease the optical shadowing and increase the photogenerated current. Here, we observe a high fill factor of 87% at 1-Sun light intensity and we observe no degradation on the open-circuit voltage. The short-circuit current density is found to increase by 0.4 mA/cm 2 when compared to previously demonstrated electroplated Ni/Au front grid fingers, resulting in an efficiency improvement of ~0.8% absolute.

14 SOLAR ENERGY↗

Reduced-Order Parameterized Short-Circuit Current Model of Inverter-Interfaced Distributed Generators

The short-circuit response of inverter-interfaced distributed generators (IIDGs) is not adequately represented in many conventional protection studies. This paper presents an in-depth analysis of IIDG behavior during grid faults and proposes a more accurate reduced-order parameterized short-circuit current (RPSC) model of inverters. Typical inverter components are thoroughly investigated to identify those that play dominant roles during faults. The paper shows that the current limiter is the dominant factor for the steady-state fault-current of inverter; while the inverter filter along with the severity of the voltage disturbance largely determine the initial transient spike of inverter fault current. The proposed model is low-order and can be used in large scale simulations. The parameters of the proposed RPSC model can be extracted from laboratory experiments without requiring proprietary manufacturer information. The proposed fault-current model is analogous to the well-known synchronous machine model that segregates the inverter fault current into subtransient, transient, and steady-state fault currents. Finally, experimental and simulation tests are presented to validate the model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection Challenges

Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this article is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line to ground, and three-phase electrical faults.

42 ENGINEERING↗

Inverter Design with High Short-Circuit Fault Current Contribution to Enable Legacy Overcurrent Protection for Islanded Microgrids

The resiliency offered by a microgrid may be lost if the microgrid is not properly protected during short-circuit faults inside its boundaries. Many studies conclude that protecting microgrids in islanded mode is very challenging due to the limited short-circuit capability of distributed energy resources (DERs). The limited short-circuit capability of DERs typically inhibits the use of reliable and affordable overcurrent protective devices in microgrids. Although extensive research on microgrid protection is available in the literature, to date this research has not led to a cost-effective, commercially available relay that effectively tackles the challenges of microgrid protection. This work proposes hardware modifications to enhance the current contribution of an energy storage inverter with the objective of enabling the use of legacy overcurrent protection for islanded microgrids. This paper demonstrates through experimental results that few modifications are required in the inverter to significantly enhance its current contribution. In this study, a three-phase energy storage inverter was modified to provide three times its rated current during three-phase faults, which proved sufficient current for enough time to enable fuse-relay, and relay-to-relay coordination. The proposed modifications effectively increase the current contribution of the inverter, which is a promising advancement to allow the adoption of overcurrent protective devices for protecting microgrids.

Ferrari Maglia, Max↗

In Situ Measurement of Temperature Distributions in a Li-ion Cell during Internal Short Circuit and Thermal Runaway

Here we report in situ measurement of temperature distributions in a 2.5-Ah pouch format Li-ion cell during internal short circuit (ISC) and thermal runaway. The ISC and thermal runaway were triggered by nail penetration. The local temperatures were measured by embedded K type micro thermocouples in the middle layer of the experimental Li-ion cell. Highly non-uniform temperature distributions were observed during ISC and thermal runaway as compared with those during constant current discharging and external short circuit. The in situ measurement also captured details of how thermal runaway started from the ISC location and spread to the entire cell in a few seconds. Moreover, the comparison between ISC without thermal runaway and ISC with thermal runaway suggests that internal short circuit resistance plays a critical role in the risk of thermal runaway.

Huang, Shan↗

Parameterization of generic positive sequence models to represent behavior of inverter based resources in low short circuit scenarios

The connection of large inverter based resources (IBR) in transmission systems is often located geographically and electrically far away from load centers. This, coupled with the displacement of synchronous machine plants, results in a reduction of the network short circuit strength at the point of connection. Under these conditions, state-of-the-art positive sequence simulation platforms and models can have difficulties maintaining numerical stability and/or providing an accurate representation of IBR plant dynamic behavior. As a result, computationally heavy time domain electromagnetic transient (EMT) simulations may be required to evaluate these systems. In this paper, a recently developed improved generic positive sequence model is parameterized to provide a representation of IBR behavior in low short circuit networks. Further, comparisons against generic and detailed EMT models demonstrate the suitability of the improved positive sequence model to study practical stability issues experienced with presently in-service plants. Such a model can provide some of the accuracy of an EMT representation with a much lower computational burden. The performance of the positive sequence model is validated against the behavior shown by both open white box and closed black box EMT domain models from around the world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detection of an internal short circuit in a battery

An electrical device comprises a battery cell; a pressure sensor for measuring swelling forces of the battery cell, optionally with voltage, temperature and current sensors, and a battery management system including a controller. The controller executes a program to: (i) determine a reference swelling force corresponding to a reference electrical signal received from the pressure sensor at an earlier reference time, (ii) determine a second swelling force corresponding to a second electrical signal received from the pressure sensor at a later second time, and (iii) determine whether a risk of internal short circuit of the battery cell exists by comparing a reference level of the reference electrical signal and a signal representative of the second electrical signal. When the signal representative of the second electrical signal exceeds the reference level of the reference electrical signal by a threshold amount, a risk of internal short circuit of the cell exists.

Stefanopoulou, Anna G.↗

Accelerated Short Circuiting in Anode-Free Solid-State Batteries Driven by Local Lithium Depletion

“Anode-free” solid-state batteries (SSBs), which have no anode active material, can exhibit extremely high energy density (≈1500 Wh L -1 ). However, there is a lack of understanding of the lithium plating/stripping mechanisms at initially lithium-free solid-state electrolyte (SSE) interfaces because excess lithium metal is often used. Here, it is demonstrated that commercially relevant quantities of lithium (>5 mAh cm -2 ) can be reliably plated at moderate current densities (1 mA cm -2 ) using the sulfide SSE Li 6 PS 5 Cl. Investigations of lithium plating/stripping mechanisms, in conjunction with cryo-ocused ion beam (FIB) imaging, synchrotron tomography, and phase-field modeling, reveal that the cycling stability of these cells is fundamentally limited by the nonuniform presence of lithium during stripping. Local lithium depletion causes isolated lithium regions toward the end of stripping, decreasing electrochemically active area and resulting in high local current densities and void formation. This accelerates subsequent filament growth and short circuiting compared to lithium-excess cells. Despite this degradation mode, here it is shown that anode-free cells exhibit comparable Coulombic efficiency to lithium-excess cells, and improved resistance to short circuiting is achieved by avoiding local lithium depletion through retention of thicker lithium at the interface. These new insights provide a foundation for engineering future high-energy anode-free SSBs.

25 ENERGY STORAGE↗

Detecting Short Circuits: Post Accident Electric Vehicle Battery Safety Check

Fast and accurate detection of soft short circuits (SCs) in the battery packs of damaged electric vehicles is needed by first responders and mechanics to mitigate the potential risk from battery fires that may occur hours, days, or weeks after an accident. Here, this paper presents an SC-detection algorithm for potentially damaged lithium-ion batteries that works quickly and without a priori knowledge of the battery-pack chemistry, capacity, state of charge, or state of health. The proposed universal SC-detection algorithm is designed to be implemented on an inexpensive handheld device that can connect to and monitor the voltages of all cells in a pack. Transient filtering and linear-quadratic state observation provide estimates of normalized SC current for every cell in the pack. Cells with SC-current estimates outside a sigma-based threshold are detected. Simulations, experiments, and electric vehicle (EV) crash data are used to verify the speed, sensitivity, and accuracy of the method, demonstrating 96% accurate detection of 0.0027 C SCs in under 1 h for 5S cell groups in the lab and no false positives for crashed Volkswagen, Chevrolet, and Tesla vehicles without SCs.

25 - ENERGY STORAGE↗