Quantitative Analysis of Pulse-Shape Modeling for Shock Tests
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This thesis studies drop durability of electronic assemblies when the acceleration vector is oriented at 45° to the out-of-plane direction of the circuit card. The off-axis drop tests are accomplished with a skewed fixture and are conducted as a proxy for multiaxial drop testing. Advanced shock testing and vibration test methods have been developed over the last few decades to better represent real-world field environments during ground-based laboratory testing. However, many of these test methods require expensive and specialized equipment not available in most laboratories. An alternative approach for approximating simultaneous loading along multiple axes on conventional equipment utilizes skewed fixtures which have seen use in off-axis random vibration and drop impact testing. These methods generally rely on the conversion of a uniaxial input load from the test equipment (using a uniaxial drop tower or shaker) into a multiaxial load when resolved in the reference frame of the test article (mounted on a skewed fixture). Skewed fixture design is presented and recommendations for conducting skewed angle drop testing are introduced based on local measurements along the skewed face of the fixture to accurately monitor the impact event. Characterization tests were performed with a skewed fixture, at simultaneous acceleration loads from 500 to 3,000 g in two (in-plane and out-of-plane) directions, while meeting standard time domain tolerances. Upon experimental characterization, drop shock durability tests were conducted on a printed circuit assembly (PCA). Mean drops-to-failure were measured and quantified with Weibull statistics. Dominant solder joint failure modes were identified via failure analysis. Prior work on inclined angle impact testing is limited, and the majority of solder joint interconnect level fatigue studies are conducted considering perpendicular loading normal the circuit card. Low-cycle fatigue curves are generated based on plastic strain and plastic work density within the solder joint. A multiscale nonlinear finite element model is used to relate board-level flexure to solder joint interconnect level plastic strain. A high strain rate solder constitutive model allows for accurate modeling of solder plasticity resulting from high-impact drop shock. Fatigue parameters are computed from the Coffin-Manson relation and Palmgren-Miner damage accumulation. This work serves to apply established low-cycle fatigue methods for conventional drop shock loading (impact normal to circuit card) to non-perpendicular loading with a skewed fixture.
Shock-compressing material samples that are precompressed with diamond-anvil cells (DACs) enables benchmarking equation of state measurements over a wide range of high-pressure conditions, in particular, warm dense matter relevant to planetary science, astrophysics, and inertial confinement fusion. These targets provide optical access to the shocked sample, so optical velocity interferometry and pyrometry are typical diagnostics. We present a scaling for the coupling of the laser drive to the shock pressure in DACs based on over 150 prior experiments that can be used to design future experiments. For initial static pressures ≤ 5 GPa, using a sapphire window mitigates the effect of photoionization compared to diamond windows and allows the measurement of shock pressures up to 1 TPa with optical diagnostics.
Equation of state (EOS) measurements in the 100 s Mbar range are needed to underwrite models employed in the simulation of high energy density plasmas. To this end, a platform has been developed for fielding on the National Ignition Facility, capable of producing high-quality impedance match EOS data, wherein a planar, high-pressure, steady shock is driven into a sample package, and sample and reference standard shock velocities are measured. This platform, dubbed planar high pressure, or PHP, was fielded with an initial proof-of-concept shot in January 2023. The first PHP shot, aiming to study gold, demonstrated a pressure close to 400 Mbar, two orders of magnitude higher than previously reported gold EOS data.
94th Shock & Vibration Symposium, Dallas TX
Explore the source record for details and available documents.
Requirements specific to hydrogen rail transportation and its unique components are currently not well represented in safety codes and standards. Notably, one of the most important components of the system, the hydrogen storage vessel, may be subject to entirely different shock and vibration conditions compared to hydrogen tanks on road vehicles. This report focuses on how composite hydrogen tanks are tested for performance and how this may relate to these tanks being used on rail systems. The shock and vibration testing procedures that are relevant for hydrogen composite tanks used for rail applications have been identified, as well as some general testing requirements for hydrogen tanks and composite tanks.
Cements are a critical component in well construction, as they act to prevent well fluid and gas escape, prevent corrosion of the casing, and strengthen the wellbore to prevent deformation. Under the high temperature/pressure conditions common in geothermal systems, the injection of cold water for energy production is expected to induce cyclic damage to the borehole cement through the rapid temperature fluctuations. These “thermal shocks” are expected to cause casing shrinkage, annulus formation, and cement tensile stresses. To understand the effect of cold water injection on the wellbore environment, a set of rock-cement-steel samples were created to simulate the structure of a geothermal well. Lightweight thermally-insulating cement blends were tested under thermal shock conditions in this study. In each test, the samples were pressurized to an effective pressure of ~3.5 MPa and placed at high temperatures. Thermal shocks were performed by injecting cold water (~10-15 °C) through the samples at a constant rate while keeping the samples at high temperatures until the sample temperature stopped decreasing and deformation ceased. Eight thermal shock tests were conducted with each sample – two at 100 °C and six at 200 °C. Post-tests analysis was then conducted by cutting open each sample to examine the damage in each component of the simulated wellbore. Experimental results suggest that all samples experienced similar degrees of axial and lateral contraction during cold water injection, but for the most part this contraction is recoverable when injection halts. Post-test analysis revealed that fly ash cenosphere pre-treatment had the best effect on improving thermal shock resistance in the cement blends. Thermomechanical modeling of likely stress paths experienced by the cements during heating/cooling cycles shows that elasto-plastic cement constitutive behavior results in most plastic strain occurring during the initial heating steps, with mostly elastic strain occurring during the thermal shock cycles. In conclusion, this agrees with experimental evidence, suggesting that cement damage from shocking occurs via other mechanisms such as chemical alteration, corrosion, and fatigue.
To gain insights into thermodynamic states attained during shock compression of cemented tungsten carbide with 3.7 wt.% cobalt binder, we present results of longitudinal sound (release wave) speed measurements and their analysis at peak stresses up to 100 GPa (volumetric compression ratio ~ 15%). The sound speeds are determined using front-surface impact and release-wave overtake plate impact experimental configurations using laser interferometry. The measured sound speed data along with estimates for bulk sound speeds obtained using the fourth-order Birch-Murnaghan EoS and thermodynamics are used to determine the longitudinal moduli and shear moduli of shocked tungsten carbide at the various peak compression states attained in the experiments. Here, the longitudinal sound speeds were found to increase linearly with volume compression ratio from 6.97 ± 0.010 km/s at ambient conditions to 8.26 ± 0.156 km/s at a volume compression ratio of ~ 15%. The corresponding longitudinal elastic moduli also increase nearly linearly with the volume compression ratio but remain consistently lower than their theoretical predictions based on continuum models with no damage. Also, the sensitivity of shear moduli to pressure, as predicted by the Steinberg-Guinan model, is reduced substantially and the shear moduli of cemented WC with 3.7 wt.% Co remains nearly constant at ~ 310 GPa at the various peak compression stress states investigated in the present study.
Explore the source record for details and available documents.
We present theories and techniques to support safe, predictable, and efficient impact testing at the Sandia National Laboratories TA-III Mechanical Shock Complex (MSC), located in Building 6570. The two testing instruments used at the MSC are the 20-inch actuator, which is a launcher that propels sleds down an indoor track, and an indoor 6-in bore compressed-gas powered cannon. The theories and techniques presented derive from basic mechanical engineering principles but are significantly informed and validated by testing experience at the MSC.
The Euler equations are a subset of the magnetohydrodynamic (MHD) equations in the infinitely collisional, unmagnetized limit. MHD modeling is central to many areas of plasma physics, ranging from low-temperature glow discharges to inertial confinement fusion. An important aspect of the Euler equations is their ability to describe states with discontinuities, such as shock waves. A standard benchmark test for numerical implementation of the Euler equations is the Sod shock tube. In this test, the system is initialized at rest with a pressure and density discontinuity, which results in a shock wave traveling into the low-pressure region and a rarefaction wave traveling into the high-pressure region. Starting with the presentation of the Euler equations, a numerical algorithm is presented here to solve these equations in one dimension. This is followed by an overview of the Sod shock tube problem that includes the precise initial setup and the analytic solution. Finally, the analytic solution is compared with results from numerical simulations.
This report details the heat source impact testing performed at the Shock Thermodynamics Applied Research Facility (STAR). The purpose of these tests were to measure the impact behavior of a heated Ta-10W tantalum/tungsten alloy heat source exemplar. Each exemplar resembled a cylinder with a rectangular through-hole orthogonal to the cylinder axis-of-symmetry. In each test, the exemplar was impacted by a hardened steel impactor accelerated using the STAR air gun. The exemplars were impacted perpendicular to the through-hole and at an an angle to the cylindrical axis-of-symmetry. The exemplar bar stock source, impact angle, and impact velocity were varied throughout the testing series. High-speed video was used to measure dynamic impact behavior while photon doppler velocimetry (PDV) and shorting pins were used to measure the impact velocity. Foam support structures were used to thermally isolate the exemplar and provide a support structure which was non-perturbative to the impact event. Soft-catch techniques were used to minimize secondary impacts and enable recovery for detailed post-shot analysis. Results indicate positive correlation between exemplar fracture and the variables of impact velocity and impact angle. Exemplar fracture occurred consistently along a single corner of the through-hole.
A new reactive flow model is presented for triaminotrinitrobenzene (TATB)-based plastic bonded explosives, applicable to shock initiation and steady detonation problems of differing initial temperature. Temperature disequilibrium is assumed between unreacted explosive, material in the vicinity of compressed defects (called hot spots), and reaction products. The model incorporates temperature-dependent decomposition reaction rates. Particularly, Arrhenius model parameters were derived from quantum-based molecular dynamics simulations of TATB decomposition. Further, a model of detonation carbon aggregation is incorporated, describing the slow release of energy inherent to detonation in TATB-based materials. Model parameters were calibrated against gas gun shock initiation experiments and steady detonation rate stick tests. The predictive ability of the model in the shock initiation regime is tested against recent thin pulse experiments. The model is found to perform equally well in predicting the size-effect curve of ambient, cold, and hot rate sticks. The present work demonstrates the viability of incorporating results from subscale simulations into a continuum-scale reactive flow model.
Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal and solar power systems. GE Aerospace Research in collaboration with Heliogen Inc and Sandia National Laboratories (SNL) is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. HOTSSTAR goal is to demonstrate SiC receiver with air exit temperatures up to 1100oC. We discuss fabrication and on-sun test results of a prototype 50kWth test module. The receiver architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around central absorber. These components were fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the thermo-mechanical reliability of SiC test articles in thermal gradient/ shock environment of the application, the components were laminated with GE’s MI SiC CMC. A dedicated test facility was constructed at SNL Solar Tower to evaluate the operational performance of HOTSSTAR module under solar fluxes >200 W/cm2. We report on our final 50kW test module fabrication, integration at the test facility at Sandia, and discuss on-sun test results. We compare the performance of HOTSSTAR module relative to our model predictions.