Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Shallow Underground Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Radiation-Shielded, Shallow Underground, Long-Coherence Time Quantum Qubit Concept

Ionizing radiation from ambient radioactivity has been shown to reduce the coherence time of superconducting qubits. Qubit performance can be improved by shielding the system from external radiation: operating the system underground to reduce cosmic rays, and use of lead shielding to reduce ambient gammas. Here we present a design for a lead shield optimized for a dilution refrigerator operating in PNNL's Shallow Underground Laboratory. The shield reduces the ambient gamma flux by approximately 99.8%, so that cosmic ray muons dominate the ionizing radiation input to the qubits.

42 ENGINEERING↗

Performance testing of a Compton suppressed coincidence measurements using the Advanced Radionuclide Gamma-spectrOmeter

A Compton-suppressed multidimensional gamma-spectrometer is being developed within the Shallow Underground Laboratory (SUL) at Pacific Northwest National Laboratory (PNNL, USA). This Advanced Radionuclide Gamma-spectrOmeter (ARGO) system consists of two Broad Energy Germanium (BEGe) detectors, surrounded by a 12-detector sodium iodide (NaI) Compton suppression shield, situated inside a low-background lead and copper shield, fitted with a cosmic veto background reduction system. The detector has advanced functionality, including operation in single or combined detector mode, coincidence mode and Compton suppressed coincidence mode. Validation experiments measuring a neutron irradiated natural uranium sample, have demonstrated order of magnitude improvements in gamma detection sensitivity compared to conventional gamma-spectrometry techniques. Importantly this research demonstrates the feasibility of processing and analysing high-multiplicity datasets and the potential for high-sensitivity radionuclide measurements.

ARGO↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

Abatement of ionizing radiation for superconducting quantum devices

Ionizing radiation has been shown to reduce the performance of superconducting quantum circuits. In this report, we evaluate the expected contributions of different sources of ambient radioactivity for typical superconducting qubit experiment platforms. Our assessment of radioactivity inside a typical cryostat highlights the importance of selecting appropriate materials for the experiment components nearest to qubit devices, such as packaging and electrical interconnects. We present a shallow underground facility (30-meter water equivalent) to reduce the flux of cosmic rays and a lead shielded cryostat to abate the naturally occurring radiogenic gamma-ray flux in the laboratory environment. We predict that superconducting qubit devices operated in this facility could experience a reduced rate of correlated multi-qubit errors by a factor of approximately 20 relative to the rate in a typical above-ground, unshielded facility. Finally, we outline overall design improvements that would be required to further reduce the residual ionizing radiation rate, down to the limit of current generation direct detection dark matter experiments.

47 OTHER INSTRUMENTATION↗

Parametric optimization of PCM-enhanced underground thermal energy storage for buildings in moderate cold climates

This study presents a novel underground thermal energy storage (UTES) system designed for space heating in buildings located in moderate cold climates. The proposed UTES features a borehole with a depth of 25 ft. (7.62 m) and a diameter of 3 ft. (0.91 m), containing two helical pipe loops-one for discharge fluid and another for recharge fluid-and a thermally enhanced phase change material (PCM) layer that provides high energy storage capacity. The system requires daily thermal recharging using a low-grade heat source for a few hours and delivers continuous heating at a nearly constant discharge rate without significant performance degradation over a 24-h period. This study demonstrates that the optimized UTES, when recharged with hot fluid at an inlet temperature of 40 degrees C for 6 h daily, can provide a continuous heat discharge rate of approximately 2.9 kW for 24 h or 3.4 kW if operated under a shorter discharge period of 15 h (17:00-08:00). With a round-trip efficiency of 72-97%, the proposed UTES offers an efficient and reliable solution for short- and long-duration thermal energy storage technology, making it a promising technology for cold climates.

15 GEOTHERMAL ENERGY↗

Light detection and cosmic rejection in the ICARUS LArTPC at Fermilab

Abstract The ICARUS-T600 detector is a 760-ton Liquid Argon Time Projection Chamber (LArTPC) currently operating at Fermilab as the Far Detector in the Short Baseline Neutrino (SBN) program. The SBN program is composed of three LArTPCs with a central goal of testing the sterile neutrino hypothesis. After operating for 3-years in the Gran Sasso Underground Laboratory, the ICARUS detector was shipped to CERN where it was outfitted with 360 8” Photomultiplier Tubes (PMTs) for a new optical detection system. The PMT system detects fast scintillation light from charged particles interacting in the Liquid Argon, generating the trigger signal for the full detector and allows 3D reconstruction of events. Now operating at shallow depth, the detector is exposed to a high flux of cosmic rays that can fake neutrino interactions. To mitigate this effect a Cosmic Ray Tagger (CRT) and a 3-meter-thick concrete were installed. Precise timing information from both the PMT and CRT subsystems can help to identify whether an interaction originated from inside or outside of the ICARUS cryostat. This paper reviews a method for cosmogenic background reduction and timing calibration of the CRT and PMT light detection systems in ICARUS.

Instruments & Instrumentation↗

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors↗

Study of space charge in the ICARUS T600 detector

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. We report a detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STILGAR End-of-Project Report

The Subsurface Tunnel Imaging LeveraGed by Analysis of Rayleigh wave ellipticity (STILGAR) project demonstrated an integrated geophysical approach for detecting, locating, and characterizing underground structural changes using dense seismic arrays and advanced inversion techniques. Field campaigns were conducted at two operational mines—the Redmond salt mine (Utah) and Graymont Pleasant Gap limestone mine (Pennsylvania)—providing real-world testbeds for monitoring anthropogenic subsurface activity. At the Redmond salt mine, seismic interferometry combined with back-projection inversion successfully identified continuous, low-amplitude signals from mining operations. The approach differentiated stationary from migrating anthropogenic sources, captured daily operational cycles, and validated the potential of passive seismic monitoring for remote detection of underground activity. At the Graymont Pleasant Gap mine, two dense seismic deployments in the spring and fall of 2023 generated over 4 TB of high-resolution data. Key outcomes included the relocation of 199 underground and 8 surface explosions with accuracies within tens of meters and the development of a 3D P-wave velocity model using the triple-difference tomography algorithm (tomoTD) that resolved major structural features such as the mine entrance, low-velocity tunnels, and roof-collapse areas. Ambient noise cross-correlation and back-projection analyses revealed persistent sources linked to ongoing mining activity, whereas horizontal-to-vertical spectral ratio (HVSR) and ellipticity studies confirmed stable site responses across seasons and identified soil thickness trends consistent with regional erosional and depositional processes. Checkerboard and sensitivity tests further validated the robustness of the tomographic results. Overall, the findings emphasize that although significant progress has been made in subsurface imaging, further work is needed to enhance the detection and localization of underground structures. Accurate imaging requires higher frequencies, yet anthropogenic sources tend to dominate the seismic record at those frequencies, and high-frequency surface waves are affected by higher modes that complicate interpretation. The improved detection and localization of human-induced signals enabled detailed temporal and spatial mapping of daily mine operations, demonstrating the feasibility of continuous anthropogenic source monitoring. Sensitivity to signals from nontraditional sources, such as fan operations, highlights the broader applicability of this approach to other industrial environments in which continuous and impulsive signals are present. The field campaigns produced a substantial volume of high-quality seismic data, supporting the development and testing of new methods for seismic source characterization and subsurface imaging. Future deployments should include sensors capable of recording lower frequencies to probe deeper structures, increase bandwidth to enhance resolution and sensitivity to both shallow and deep targets, and collect additional large-scale datasets to refine imaging and source characterization techniques. Moreover, conducting 3D modeling studies of seismic wavefields at higher frequencies will provide a better understanding of wave scattering and cavity–wavefield interactions in complex underground environments. In conclusion, the STILGAR project demonstrated that integrated seismic monitoring can effectively characterize underground operations, capturing both natural and anthropogenic signals. The approaches developed provide a foundation for improved detection, localization, and imaging of subsurface structures and are directly transferable to broader industrial monitoring applications.

58 GEOSCIENCES↗

Risk assessment of wellbore leakage during underground hydrogen storage

The expansion of renewable energy sources would require large-scale energy storage options to overcome the intermittent nature of these sources. Underground hydrogen storage (UHS) in depleted hydrocarbon reservoirs offers a scalable and practical energy storage solution. These reservoirs are chosen for their availability and large capacity, but the unique properties of hydrogen raise concerns about potential leakage pathways, particularly through wellbores. In this study, we develop and apply, for the first time, reduced-order models (ROMs) specifically designed for efficient leakage risk prediction in UHS systems operating in depleted hydrocarbon reservoirs. Using 3,000 high-fidelity simulation scenarios, we examine the influence of 11 key parameters, including reservoir and aquifer depths, wellbore permeability and porosity, initial saturations of water, oil and gas fractions (hydrogen, light, intermediate, and heavy hydrocarbons), reservoir pressure multiplier, and the aquifer-to-reservoir volume ratio, to simulate leakage behavior over a 1,000-year timescale. We train ROMs using a two-step classification-regression approach, achieving R 2 values exceeding 99 % across all targets. These ROMs effectively capture the leakage evolution and identify critical controls of leakage, guiding the design of mitigation strategies. Results indicate that gas leakage occurs in about 27 % of scenarios as early as five years post-operation, reaching volumes of up to 106 ft3. Oil leakage is less frequent (~17 %) and typically begins decades later. Our findings also show that hydrogen often migrates first, owing to its smaller molecular size and higher buoyancy, followed by heavier hydrocarbons. Over time, these heavier components contribute significantly to the total leaked volume, reinforcing the need for targeted monitoring and remediation strategies. Our analysis highlights that deeper storage reservoirs, shallower aquifers, and low-permeability wellbores significantly reduce leakage risks. In conclusion, this work offers a robust framework for risk-informed UHS deployment, supporting energy security through reliable large-scale hydrogen storage while safeguarding environmental integrity.

08 HYDROGEN↗

Potential Chemical Impacts of Subsurface CO 2 : An Integrated Experimental and Numerical Assessment for a Case Study of the Ogallala Aquifer

Leakage from geologic CO 2 sequestration (GCS) reservoirs to overlying underground sources of drinking water (USDW) is a tangible risk. This study is an integrated assessment that combines column experiments and reactive transport simulations of sediments sampled from the Ogallala aquifer above an active commercial-scale GCS site (the Farnsworth Unit in northern Texas). Experimental and simulation results suggest that carbonate mineral (calcite and dolomite) dissolution is the most significant reaction following CO 2 intrusion, and is also the dominant source of trace metal release. Cation exchange is another key mechanism controlling trace metal release by cation interference. Most of the trace metals, including Ba, Sr, As, Pb, and Zn, show a short-term release and quickly drop to the baseline values, suggesting low risk to the overlying USDW quality. Other trace metals, such as Mn and U, exhibit a tangible increase of their concentrations in the beginning, and drop to a higher level compared to the baseline, which may become a potential concern of long-term USDW quality change with CO2introduction. This study provides a comprehensive example of combining laboratory experiments and simulations for assessment of CO 2 -sediment interactions with combined release mechanisms in shallow groundwater aquifers. Data presented here provides useful insights for quantitative risk assessment and effective public education regarding CO 2 geological sequestration, and trace metal reactive transport studies in shallow groundwater aquifers.

54 ENVIRONMENTAL SCIENCES↗

First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soil Interim Measures Implementation Report Q6 Radar Station – Solid Waste Management Unit 112 Locations of Concern 3 and 10 Kennedy Space Center, Florida

This report presents a summary of the soil interim measures (IM) implementation activities that occurred from January 23 through June 6, 2023, at the Q6 Radar Station (Q6RS) Solid Waste Management Unit (SWMU) 112, located at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program, which also meets the requirements of Chapter 62-780, Florida Administrative Code. Assessment activities have previously been performed at 10 Q6RS Locations of Concern (LOCs), identified during a SWMU assessment in 2013 (NASA 2013). Since the SWMU assessment, further confirmatory sampling and assessment was conducted for each LOC, and based on the data collected during these assessments, it was determined that Resource Conservation and Recovery Act Facility Investigation to further evaluate soil and groundwater was to be conducted at two LOCs: LOC 1 – Former Underground Storage Tanks (groundwater) and LOC 3 – Radar Antenna Refurbishment Area (soil). The LOC 1 groundwater assessment is ongoing, and the results will be presented under a separate cover. It was also determined that soil IM would be completed at two of the LOCs, LOC 3 and LOC 10 – Compressor Building Condensate Discharge. A Soil IM Work Plan was prepared and submitted in October 2021 (NASA 2021). The plan proposed excavation and disposal of barium and copper impacted soil in the LOC 3 and 10 areas. This report presents a summary and results of the soil IM implementation activities conducted at LOCs 3 and 10. The site contaminates of concern for this soil IM are barium and copper. The activities presented in this report includes soil IM implementation and groundwater sampling. From January 23 through March 24, 2023, AECOM Technical Services, Inc. (AECOM) field personnel conducted IM implementation activities in the LOC 3 and 10 areas. As presented in the IM Work Plan, shallow soils, impacted with metals, were excavated to a depth of 2 feet below land surface in the central area of the site around the radar antenna and associated equipment. AECOM personnel excavated 77.43 tons of soil using hand tools and, when able, heavy equipment. The soils were placed into lined roll-off containers, which were covered and transported under manifest to the Cedar Trail Landfill in Bartow, Florida. The site was restored to original condition using certified clean backfill material (sand), with filter fabric, and gravel. Areas outside of the excavation were restored with grass seed. On June 6, 2023, AECOM field personnel conducted groundwater sampling activities within the soil IM excavation area. AECOM personnel collected one groundwater sample from monitoring well Q6RS-MW0003. The sample was submitted to a fixed-based laboratory for analysis by United States Environmental Protection Agency Method 6020B for metals (barium and copper). Barium and copper were detected at 18 micrograms per liter (µg/L) and 14 µg/L, respectively, and were below the State of Florida Groundwater Cleanup Target Levels (GCTLs) for barium at 2,000 µg/L and copper at 1,000 µg/L.

Chadwick Sloan Lee↗

Nonenergy Biomass Carbon Removal and Storage (BiCRS): Assessing Durability of Nongaseous Carbon Products Across Terrestrial Storage Fates

Biomass Carbon Removal and Storage, or BiCRS, pathways use plants or algae that remove carbon dioxide from the atmosphere through photosynthesis and store it underground or in long-lived products. While some BiCRS approaches generate an energy product, all BiCRS approaches generate a carbon product. A new subset of BiCRS approaches focus on the storage of these raw or converted carbon products for generation of carbon credits. However, the durability of these approaches is highly variable as carbon products vary widely in their “form” and the conditions of their “fate.” We organize our thinking about carbon products and their durability around these two primary axes. The durability of carbon product “forms” is mediated by chemical recalcitrance and ranges substantially across agricultural residues, municipal solid waste, woody biomass, and nongaseous products of thermochemical conversion (e.g., biochars and bio-oils). Meanwhile, terrestrial storage “fates” vary in the mechanism employed to stall decay, including surface storage, dry storage, shallow anoxic storage, and deep or geologic anoxic storage (or injection). Each mechanism has different implications for suitability with different feedstock forms as well as long-term risks. We present a framework for assessing durability of solid or liquid raw and conversion carbon products under terrestrial storage fates, highlighting knowns, unknowns, and research priorities moving forward.

09 BIOMASS FUELS↗

MR13A-3183: Microbial and Geochemical Characterization of Groundwater: Implications for Underground Hydrogen Storage Leakage

Underground hydrogen storage (UHS) in geological formations is a key element of the clean energy transition as it enables the decarbonization of the transportation and industrial sectors by decoupling hydrogen production and storage. UHS has many benefits, including low cost, much wider availability, large storage capacity, well-established infrastructure, and increased safety because of geological sealing capabilities. However, the impact of hydrogen (H2) biogeochemical interactions in the presence of subsurface microorganisms is largely neglected from UHS perspectives. These interactions might affect the effectiveness of storage and can even cause H2 to leak into the shallow aquifers. Leakage of H2 into groundwater can change the geochemistry and induce several microbial-driven processes. Microorganisms, such as sulfate-reducers, are naturally abundant in groundwater and consume H2 to produce hydrogen sulfide (H2S), which can contaminate the freshwater drinking groundwater and cause damage to infrastructure. Hydrogen leakage can also trigger microbial reactions responsible for metal mobility, which can impact the water quality. However, the kinetics of these reactions and the temporal impact of hydrogen leakage in groundwater are still unknown. Therefore, a time series hydrogen-groundwater interaction experiment was conducted, and the changes in fluid chemistry and headspace gas composition will be analyzed along with DNA sequencing results to understand the extent and kinetics of biogeochemical reactions that occur if hydrogen leaks into groundwater. In the experiments, Ultra High Purity (UHP) hydrogen gas will be injected into glass vials with groundwater samples, for a designated time period. For each glass-sealed vial, 16S rRNA gene sequencing, IC, ICP-MS, and GC-TCD will be performed. The experiments provide insights into plausible impacts of hydrogen leakage into shallow drinking water aquifers.

Clark, Allison [West Virginia University (WVU)]↗