Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Seven Percent Critical Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.

Criticality↗

Experimental Investigation of Subcritical Neutron and Gamma Noise Methods at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by the Lawrence Livermore National Laboratory (LLNL), with key participants from the Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and the Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements was planned and executed. The primary aim of this article was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work, we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods. Our results agree well with independent experimental measurements and simulations performed by LLNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Seven Percent Critical Experiment Core Analysis Approach on Fuel Rods – Core Configurations T155-NoMo, and T155-397Mo.

A series of experiments will be performed to test the integral effects of molybdenum on the reactivity of a critical system. These experiments will use the 7uPCX assembly with the 1.55 cm triangular pitch grid plates. Molybdenum sleeves, consisting of 19.6 inch long 0.5-inch nominal outside diameter molybdenum tubes with 0.031-inch nominal wall thickness and centering hardware, will be placed on some of the fuel rods in the array. The purpose of this analysis is to examine two configurations of the 7uPCX using the 1.55 cm triangular pitch grid plates in fully-reflected approach-to-critical experiments with the number of fuel rods in the array as the approach parameter. This document presents the results of the analysis that was done to allow completion of the 7uPCX Configuration Checklist from Appendix A of SPRF-AP-005 [SNL 2020] for the cores noted above. The checklists for these cores are shown in Appendix A.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX) [Slides]

Post measurement synchronization of noise signals allowed for the investigation of previously unseen correlations. Noise of gamma, thermal and fast neutron signals performed similarly in estimating the prompt neutron decay constant at various subcritical states. The CPSD amplitude terms displayed different magnitudes. The neutron-based amplitudes suffered more from changes in detector efficiency as the number of fuel rods in the system increased. The time lag between 3 He tubes is observable using the CPSD phase angle and agreed with a simplified diffusion estimation.

3He detectors↗

Design of Temperature Dependent Critical Experiments with SPRF/CX

This paper describes the investigation of temperature-dependent critical experiments using the Seven Percent Critical Experiments (7uPCX) and Burnup Credit Critical Experiments (BUCCX) fuel types within the Sandia Pulsed Reactor Facility/Critical Experiments (SPRF/CX) apparatus at Sandia National Laboratories (Sandia). The goal of these experiments is to test the effect of varying system temperature on the $\kappa$ eff bias of water-moderated systems. Temperatures of 5–95°C were considered in this work. Eighteen representative lattice configurations were analyzed that had variations in the number of fuel rods and water holes, as well as in the array configuration, to achieve a variety of moderation regimes. The configurations were based on those detailed in the LEU-COMP-THERM-078 and LEU- COMP-THERM-079 experiments, both of which were published in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of Critical Experiments Targeting Epithermal Cross Sections of Tantalum

Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) are collaborating to develop a capability to test the epithermal/intermediate cross sections of tantalum (Ta) at the SNL critical experiments facility using the Seven Percent Critical Experiment (7uPCX) fuel. The Sandia Critical Experiments (SCX) Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. A history of safe reactor operations and flexibility in reactor core configuration has resulted in the completion of several benchmark critical experiment evaluations that are published in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The critical experiments described here are scheduled to be performed at SCX in fiscal year 2023. Currently, fabrication details for the needed new equipment are being finalized for completion of the procurement process. The experiments will then be executed and documented for publication consideration by the ICSBEP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IER 441: Experiments to Measure the Effect of Tantalum on Critical Systems (SNL/ORNL) [Slides]

This presentation provides information on the experiments to measure the effect of Tantalum (Ta) on critical systems. This talk presents details on the Sandia Critical Experiments Program with the Seven Percent Critical Experiment (7uPCX) and the Burnup Credit Critical Experiment (BUCCX). The presentation highlights motivations, experiment design, and evaluations and publications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experiments to Measure the Effect of Tantalum on Critical Systems

Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) collaborated to develop a capability to test the epithermal/intermediate cross sections of materials at the SNL critical experiment facility using the Seven Percent Critical Experiment (7uPCX) fuel. As a result, a new set of critical experiments has been designed to target the epithermal cross sections of tantalum (Ta) and is scheduled to be performed at SNL in 2023. These critical experiments will be evaluated for inclusion in the 2024 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The focus of these critical experiments is to measure the effects of Ta on the critical array size. The critical array size will be determined by an approach-to-critical experiment with the number of fuel rods in the array as a free parameter. The core configurations are designed to optimize the reactivity worth of Ta and the overall percentage of Ta absorption rates in the epithermal/intermediate energy range (0.625 eV – 100 keV). The baseline core configuration includes 7uPCX fuel rods set at a triangular pitch of 1.016 cm and a central dry test region that utilizes a cadmium liner for filtering out thermal neutrons. The central test region has locations for 85 Ta rods set at a triangular pitch of 0.813 cm. The Ta reactivity worth for the case with 85 Ta rods is approximately 2.55%, with the percentage of Ta absorption rates within the intermediate energy range at nearly 90%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical Experiments Targeting the Epithermal/Intermediate Cross Sections of Tantalum

Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) have collaborated to develop a capability to test the epithermal/intermediate cross sections of materials at the SNL critical experiments facility using the Seven Percent Critical Experiment (7uPCX) fuel. The Sandia Critical Experiments Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. The facility offers the ability to modify the core configuration and reactor tank to evaluate various reactor cores for pitch, moderator characteristics, and other criteria. A history of safe operations and flexibility in reactor core configuration has resulted in the completion of nine sets of critical benchmark experiments that have been documented in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The experiment described here is expected to be evaluated for inclusion in the 2024 edition of the ICSBEP Handbook.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sandia 7uPCX Critical Experiments Exploring the Effects of Fuel-to-Water Ratio Variations

The Sandia Critical Experiments (SCX) Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. A history of safe reactor operations and flexibility in reactor core configuration has resulted in the completion of several benchmark critical experiment evaluations that are published in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The LEUCOMP-THERM-078 and LEU-COMP-THERM-080 evaluations from the handbook provide similar cases for reference. The set of experiments described here were performed using the Seven Percent Critical Experiment (7uPCX) fuel to measure the effects of decreasing the fuel-to-water volume ratio on the critical array size. This was accomplished by using fuel loading patterns to effectively increase the pitch of the fuel arrays in the assembly. The fuel rod pitch variations provided assembly configurations that ranged from strongly undermoderated to slightly overmoderated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Multiplication Neutron Noise Measurements Using the 7uPCX Assembly

The Seven Percent Critical Experiment, or 7uPCX, is a system that mimics the physics of light water nuclear reactor systems by using uranium dioxide fuel pins at an enrichment of approximately 7%. 7uPCX is often used for benchmarking and nuclear data purposes. As part of a collaboration between Lawrence Livermore National Laboratory, Los Alamos National Laboratory, Sandia National Laboratories, and the Institut de Radioprotection et de Sûreté Nucléaire, measurements were performed in support of a high-multiplication, subcritical benchmark candidate for a thermal system. The measurements were completed by making subcritical configurations using the fuel loading pattern of a well-documented configuration of the Seven Percent Critical Experiment at Sandia National Laboratories, which exists as a benchmark in the International Criticality Safety Benchmark Evaluation Project handbook. These measurements, which aimed to capture multiplications ranging from approximately 10 to 1,000, also serve as an intercomparison between both the fielded detector systems and analysis methodologies with the goal of better characterizing the detectors and their ability to capture the state of the criticality these types of systems. Los Alamos National Laboratory’s measurements for this collaboration were made with five linked helium-3 based neutron multiplicity detectors placed on the periphery of the reactor tank beyond the infinite reflector thickness of water, and four organic scintillators placed in dry-wells in-reactor near the edge of the upper fuel grid plate. This work captures the Los Alamos National Laboratory measurements, the Rossi-α and Feynman-Y results, provides an intercomparison between the results of the 3 He neutron detectors and the organic scintillators, compares to simulation where possible, and expands on future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integral Experiment Request 554 CED-1 Summary Report

This Critical Engineering Decision 1 report for the Integral Experiment Request 554 describes the effects of adding a commercially available neutron absorber material to a known light-water low-enriched uranium assembly. The assembly in question is the Seven Percent Critical Experiments at Sandia National Laboratories. The neutron absorber plates considered for the experiment are called Boralcan, which are made of boron carbide (B 4 C) particles embedded in 1100 aluminum alloy. The concentrations of B 4 C and 1100 aluminum, as well as the thickness and size of the plates, were changed, and the fuel rod configuration was adapted to ensure that the assembly would be critical in each case studied. A total of 10 critical configurations with a neutron absorber plate inserted are described in this report. No results of high-quality integral experiments involving neutron absorbers made with B 4 C and 1100 aluminum plates are currently publicly available. Sensitivity to the neutron absorber plate material definition, isotopes, and cross sections of specific regions and configurations are also analyzed. The study results indicate that these experiments are achievable with sufficiently low uncertainties and minimal modification to the assembly. The experimental uncertainty can be further decreased with an additional characterization of the plates by x-ray computerized tomography or neutron radiography methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Completion of Critical Experiments with Molybdenum Sleeves at Sandia

Sandia National Laboratories (SNL) and the Institut de Radioprotection et de Sûreté Nucléaire (IRSN) have collaborated on the design and execution of a set of critical experiments that explore the effects of molybdenum in water moderated fuel-rod arrays. The molybdenum is included as sleeves (tubes) on some of the fuel rods in the arrays. The fuel used in the experiments is known at Sandia as the Seven Percent Critical Experiment (7uPCX) fuel. This fuel has been used is several published benchmark evaluations in including LEU-COMP-THERM-78 and LEU-COMP THERM-080.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Experiment Request 554: CED-2 Summary Report

This report summarizes the critical experiment design 2 (CED-2) or final design study for Integral Experiment Request 554 (IER-554). This experiment describes the effects and importance of adding a commercially available neutron absorber material to a known light-water low-enriched uranium assembly. The assembly in question is the Seven Percent Critical Experiments (7uPCX) at Sandia National Laboratories. The neutron absorber plates considered for the experiment are known as Boralcan and are made of boron carbide (B 4 C) particles embedded in 1100 aluminum alloy. The concentrations of B 4 C and 1100 aluminum were changed as well as the thickness and the positions of the plates, and the fuel rod configuration was adapted to ensure that the assembly would be critical in each case studied. A total of 6 critical configurations, each with a neutron absorber plate inserted, are described in this report. No results of high-quality integral experiments involving neutron absorbers made with B 4 C and 1100 aluminum plates are currently publicly available. Sensitivity to the neutron absorber plate material definition, isotopes, and cross sections of specific regions and configurations are also analyzed. As part of the final design of the experiment, a safe plate holder made of 3003 aluminum was designed. The study results indicate that these experiments are achievable with sufficiently low uncertainties and minimal modification to the assembly, and the CED-3 phase can start when funding allows.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Experiment Request 523 CED – 1 Report

This report documents the preliminary design phase of the Critical Experiment Design (CED-1) conducted as part of integral experiment request (IER) 523. The purpose of IER-523 is to determine critical configurations of 35 weight percent (wt%) enriched uranium dioxideberyllium oxide (UO 2 -BeO) material with Seven Percent Critical Experiment (7uPCX) fuels at Sandia National Laboratories (Sandia). Preliminary experiment design concepts, neutronic analysis results, and proposed paths for continuing the CED process are presented. This report builds on the feasibility and justification of experimental need report (CED-0) completed in December 2021.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pitch Variation Experiments in Water-Moderated Square-Pitched U(6.9)O 2 Fuel Rod Lattices with Fuel to Water Volume Ratios Spanning 0.08 to 0.67

The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5% 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad square-pitched U(6.90%)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMPTHERM- 096, LEU-COMP-THERM-097, and LEU-COMP-THERM-101. The twenty-seven critical experiments in this series were performed in 2020 in the SCX at the Sandia Pulsed Reactor Facility. The experiments are grouped by fuel rod pitch. Case 1 is a base case with a pitch of 0.8001 cm and no water holes in the array. Cases 2 through 6 have the same pitch as Case 1 but contain various configurations with water holes, providing slight variations in the fuel-to-water ratio. Similarly, Case 7 is a base case with a pitch of 0.854964 cm and no water holes in the array. Cases 8 through 11 have the same pitch as Case 7 but contain various configurations with water holes. Cases 12 through 15 have a pitch of 1.131512 cm and differ according to the number of water holes in the array, with Case 12 having no water holes. Cases 16 through 19 have a pitch of 1.209102 cm and differ according to number of water holes in the array, with Case 16 having no water holes. Cases 20 through 23 have a pitch of 1.6002 cm and differ according to number of water holes in the array, with Case 20 having no water holes. Cases 24 through 27 have a pitch of 1.709928 cm and differ according to number of water holes in the array, with Case 24 having no water holes. As the experiment case number increases, the fuel-to-water volume ratio decreases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molybdenum Sleeve Experiments in Fully-Reflected Water-Moderated Triangular-Pitched U(6.90)O 2 Fuel Rod Lattices (1.55 cm Pitch)

The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMP-THERM-096, LEUCOMP-THERM-097, LEU-COMP-THERM-101, and LEU-COMP-THERM-102. The purpose of these experiments was to measure the effects of molybdenum in nearly-critical systems. The molybdenum was introduced into the fuel arrays as tubular sleeves that surrounded some of the fuel rods in the fuel arrays measured. Four hundred molybdenum tubes nominally 12.7 mm outside diameter, 498 mm long, with 0.762 mm wall thickness were provided for the experiments by the Institut de Radioprotection et de Sûreté Nucléaire (IRSN). Small polyethylene adapters at each end of the tubes were used to center each tube on a fuel rod in the assembly. The critical experiments were done using a set of triangular-pitched grid plates fabricated for these experiments. The grid plate set accommodated a fuel array of a total of 1261 fuel rod positions on a pitch of 0.610 in (1.5494 cm) in a series of 20 hexagonal rings surrounding the central fuel rod. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The five critical experiments in this series were performed in August through December 2022, in the Sandia Critical Experiments (SCX) at the Sandia Pulsed Reactor Facility. Case 1 had no molybdenum sleeves, Case 2 had 208 molybdenum sleeves clustered at the center of the array, Case 3 had 397 molybdenum sleeves clustered at the center of the array, Case 4 had 175 molybdenum sleeves in the central position and in five alternating hexagonal rings, and Case 5 had 331 molybdenum sleeves in the central position and in seven alternating hexagonal rings. All five critical experiments are judged to be acceptable as benchmark experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗