Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sentinel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Software for High-Resolution Flood Mapping With Sentinel-1 and Sentinel-2 via Misalignment-Robust Cross-Sensor Learning and Generative Despeckling

SF-26-078 This software provides a high-level workflow for satellite-based flood and surface-water mapping using Sentinel-1 SAR and Sentinel-2 multispectral imagery. It supports preparation of remote-sensing data, training and evaluation of deep-learning models, and generation of high-resolution water extent predictions, including methods to improve robustness to SAR speckle noise and cross-sensor image misalignment.

Feinstein, Jeremy [Argonne National Laboratory (AN↗

Indocyanine Green Fluorescence Imaging with Lymphoscintigraphy for Sentinel Node Biopsy in Melanoma: Increasing the Sentinel Lymph Node-Positive Rate

Introduction: The goal of this study was to analyze patients who underwent a sentinel lymph node biopsy (SLNB) in melanoma with the combination of radioisotope lymphoscintigraphy and indocyanine green (ICG) fluorescence imaging to compare our true positive (TP) rate, a means to perform immediate analysis of the SLNB, with that of the literature. Methods: Consecutive cutaneous melanoma patients who underwent SLNB with lymphoscintigraphy and ICG-based fluorescence imaging by the senior author (BG) from 2012 to 2018 were prospectively enrolled. The average expected SLN-positive rate per T stage was calculated based on three studies and compared with our SLN-positive rate. Results: Overall, 574 consecutive patients were analyzed. Average Breslow thickness was 1.9 mm. A total of 1754 sentinel nodes were sampled; 1497 were identified by gamma probe signaling and ICG, 241 were identified by gamma probe signaling only, and 16 were identified by ICG only. There were 123 (21.4%) patients with at least one positive SLN; 113 (91.9%) had at least one positive node identified with both gamma probe signaling and ICG, 8 (6.5%) had positive node(s) identified with gamma probe signaling only, and 2 (1.6%) had positive node(s) identified with ICG only. There was an overall 21.4% SLN-positive rate, with 8% T1, 18.5% T2, 41.1% T3, and 52.4% T4, which is higher than the predicted rates for each stage. Conclusions: With the largest cohort of patients reported who underwent a melanoma SLNB with lymphoscintigraphy and ICG, we demonstrated that this technique results in higher SLN-positive rates than predicted. Patients are being followed but, given the TP data, knowledge of our results may foster the use of this modality to improve staging and treatment options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regional Recurrence Risk Following a Negative Sentinel Node Procedure Does Not Approximate the False-Negative Rate of the Sentinel Node Procedure in Breast Cancer Patients Not Receiving Radiotherapy or Systemic Treatment

Background: Although the false-negative rate of the sentinel lymph node biopsy (SLNB) in breast cancer patients is 5–7%, reported regional recurrence (RR) rates after negative SLNB are much lower. Adjuvant treatment modalities probably contribute to this discrepancy. This study assessed the 5-year RR risk after a negative SLNB in the subset of patients who underwent breast amputation without radiotherapy or any adjuvant treatment. Methods: All patients operated for primary unilateral invasive breast cancer between 2005 and 2008 were identified in the Netherlands Cancer Registry. Patients with a negative SLNB who underwent breast amputation and who were not treated with axillary lymph node dissection, radiotherapy, or any adjuvant systemic treatment were selected. The cumulative 5-year RR rate was estimated by Kaplan–Meier analysis. Results: A total of 13,452 patients were surgically treated for primary breast cancer and had a negative SLNB, and 2012 patients fulfilled the selection criteria. Thirty-eight RRs occurred during follow-up. Multifocal disease was associated with a higher risk of developing RR (P = 0.04). The median time to RR was 27 months and was significantly shorter in patients with estrogen receptor-negative (ER−) breast cancer (9.5 months; P = 0.003). The 5-year RR rate was 2.4% in the study population compared with 1.1% in the remainder of 11,440 SLNB-negative patients (P = 0.0002). Conclusions: Excluding the effect of radiotherapy and systemic treatment resulted in a twofold 5-year RR risk in breast cancer patients with a tumor-free SLNB. This 5-year RR rate was still much lower than the reported false-negative rate of the SLNB procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overall and cause‐specific mortality in the Sentinel system: A power analysis

Abstract Purpose Mortality data within the Sentinel Death Tables remain generally uncharacterized. Assessment of mortality data within Sentinel will help inform its utility for medical product safety studies. Methods To determine if Sentinel contains sufficient all‐cause and cause‐specific mortality events to power postmarketing safety studies. We calculated crude rates of all‐cause mortality and suicide and proportional mortality from suicide from 2004 to 2012 in seven Sentinel data partners. Results were stratified by data partner, sex, age group, and calendar year and compared with national estimates from Centers for Disease Control and Prevention Wide‐ranging ONline Data for Epidemiologic Research. We performed sample size estimations for all‐cause mortality and 10 leading causes of death. Results We observed 479 694 deaths, including 5811 suicides, during 68 million person‐years of follow‐up. Pooled mean death and suicide rates in the data partners were 710 and 8.6 per 100 000 person‐years, respectively (vs 810 and 11.8 nationally). The mean proportional mortality from suicide among the data partners was 1.2%, compared with 1.5% nationally. National trends of decreasing overall mortality and increasing proportional mortality for suicide were reflected within Sentinel. We estimated that detecting hazard ratios of 1.25 and 3 would require 16 442 and 460 exposed patients, respectively, for overall mortality, and 1.3 million and 37 411, respectively, for suicide. Conclusions This was the first study to investigate mortality data in the Sentinel death tables. We found that all‐cause mortality appeared well powered for use as a safety outcome and cause‐specific mortality outcomes may be adequately powered in certain circumstances. Further investigation into the quality of the Sentinel death data is needed.

Swain, Richard S.↗

Forest aboveground biomass estimation through integration of sentinel-2 and PALSAR-2 time series: assessing models trained on GEDI and field inventory benchmarks

Accurate and spatially explicit forest Aboveground Biomass (AGB) mapping through remote sensing is critical for quantifying terrestrial carbon stocks and informing effective forest management strategies. However, AGB estimation in dense forests with complex terrain remains challenging due to satellite sensor signal saturation problem (saturation issue occurs in high biomass forests), structural complexity, and limited ground truth for calibration. This study presents a novel framework that integrates multi-temporal Sentinel-2 optical imagery, ALOS PALSAR-2 Synthetic Aperture Radar (SAR) data, and topographic variables with explainable Machine Learning to map AGB across mountainous forests within subtropical and temperate oceanic climate zones of Mexico. We evaluate the effects of temporal granularity and sensor synergy by comparing multiple temporal inputs and sensor configurations (Sentinel-2, PALSAR-2, and their fusion), and assess model performance using two reference datasets: NASA GEDI LiDAR-derived biomass and Mexico’s National Forest and Soil Inventory (INFyS). Our results showed that models trained on INFyS consistently outperformed those trained on GEDI, highlighting limitations in GEDI’s reliability in biomass estimates within this study region. Furthermore, the integration of Sentinel-2 and PALSAR-2 provided improved predictions compared to single-sensor models, particularly when combined with temporally explicit yearly statistics. The best-performing model, which was trained on INFyS data, and considered both Sentinel-2 and PALSAR-2 yearly statistics, as well as topographic variables, achieved an R2 of 0.64, RMSE of 51.10 Mg/ha, and relative RMSE (rRMSE) of 58.69%. Explainable ML analysis identified Sentinel-2 spectral indices and topographic features as key predictors, while PALSAR-2 metrics provided complementary information, partially mitigating saturation effects in high-biomass areas. Specifically, integrating both sensors substantially improved AGB estimation in high biomass forest (≥200 Mg/ha), yielding 98% gains over optical-only model, with resulting estimates exceeding GEDI L4B by 29% and ESA-CCI-BIOMASS by 174%. Terrain-stratified analysis indicated close agreement with GEDI in low-slope areas, with increasing divergence as slope steepness increased, while estimates remained consistently higher than ESA-CCI-BIOMASS across all slope classes. The proposed approach advances multi-sensor fusion and temporal feature engineering for AGB mapping using open-access satellite datasets, providing a scalable and reproducible framework for annual biomass monitoring in topographically complex mountainous forests. The resulting 25 m resolution biomass product has the potential to provide spatially detailed information for forest monitoring and may support applications in carbon accounting and forest management.

54 ENVIRONMENTAL SCIENCES↗

CalTestBed - Delphire - Testing and Evaluation of Delphire Sentinel System (CRADA Final Report)

The Delphire Sentinel is a modular fire detection and communications system operating as a mobile field unit, with low voltage DC power supplied by onboard photovoltaics (PV) and batteries. The Sentinel addresses several aspects of fire detection, communications and data analysis. The Sentinel's mobility enables it to be rapidly deployed and operate independently of existing power and communications networks. The duration of independent operation depends critically on the energy consumption of the systems and performance of the onboard PV and battery. The purpose of this testing is to ascertain the power draw and energy consumption of the Delphire Sentinel prototype system under several operational states, including various data transfer packet sizes, transmission time and frequencies, and communication pathways (Wi-Fi, cellular, satellite) expected to be encountered in field deployments. It will also include procedures to test the ability of the Sentinel to operate for extended periods without loss of functionality. Based on results from energy and power measurements, and anticipated duty cycles in field deployments, we will model annual system autonomy (e.g. loss of load probability) for off-grid operation in representative locations.

47 OTHER INSTRUMENTATION↗

MO-F-16A-04: Case Study: Estimation of Peak Skin Dose Following a Physician Reported “High Dose” Case and Sentinel Event Considerations

Purpose: This work offers as a teaching example a reported high dose fluoroscopy case and the workflow the institution followed to self-report a radiation overdose sentinel event to the Joint Commission. Methods: Following the completion of a clinical case in a hybrid OR room with a reported air kerma of >18 Gy at the Interventional Reference Point (IRP) the physicians involved in the case referred study to the institution's Radiation Safety Committee (RSC) for review. The RSC assigned a Diagnostic Medical Physicist (DMP) to estimate the patient's Peak Skin Dose (PSD) and analyze the case. Following the DMP's analysis and estimate of a PSD of >15 Gy the institution's adverse event committee was convened to discuss the case and to self-report the case as a radiation overdose sentinel event to the Joint Commission. The committee assigned a subgroup to perform the root cause analysis and develop institutional responses to the event. Results: The self-reporting of the sentinel event and the associated root cause analysis resulted in several institutional action items that are designed to improve process and safety. A formal reporting and analysis mechanism was adopted to review fluoroscopy cases with air kerma greater than 6 Gy at the IRP. An improved and formalized radiation safety training program for physicians using fluoroscopy equipment was implemented. Additionally efforts already under way to monitor radiation exposure in the Radiology department were expanded to include all fluoroscopy equipment capable of automated dose reporting. Conclusion: The adverse event review process and the root cause analysis following the self-reporting of the sentinel event resulted in policies and procedures that are expected to improve the quality and safe usage of fluoroscopy throughout the institution.

60 APPLIED LIFE SCIENCES↗

Sentinel-1 Input Data for PSInSAR Analysis

Files used to perform the Persistent Scatterer InSAR analysis with SARPROZ. The data is sourced from ESAs Sentinel-1 project and covers Brady Hot Springs and Desert Peak geothermal areas. The original titles are included for the Sentinel-1 data. The naming guide is included as a link in this submission. The data contains SAR (Radar) data from the Sentinel 1A satellite between July 2017 and December 2019. The data is necessary to replicate our results, and can be used for further PSInSAR, DInSAR and other modern interferometric analyses to determine line of sight, vertical and, possibly, East-West horizontal displacement. These displacement analysis show the soil deformation in time (including average displacement velocity), which can be used to indicate subsoil phenomena: temperature changes, subsidence, uplift, and inform other analyses like seismicity and porosity.

15 GEOTHERMAL ENERGY↗

Furthering Precision in Sentinel Node Navigational Surgery for Oral Cancer: a Novel Triple Targeting System

To describe an innovative sentinel lymph node (SLN) guidance approach using a radionuclide tracer, 3D augmented reality-guided imaging, and near infrared (NIR) fluorescence over-lay imaging with hand-held probes to optimize accuracy, efficiency, and precise navigation for sentinel node (SN) localization in head and neck cancer. In a cT1N0M0 squamous cell carcinoma of the tongue, pre-operative radionuclide lymphoscintigraphy was performed with a sentinel node-specific radiolabeled tracer. Intraoperatively, a 3D hand-held augmented reality (AR) scanning SPECT probe assessed concordance of the SN with pre-operative SPECT-CT images. The real-time optical video was linked to the SPECT-CT images for added precision. Final guidance to the SN was performed using ICG fluorescence imaging. Dynamic and SPECT-CT showed bilateral lymphatic drainage from the tumor. The 3D hand-held AR SPECT probe SN localization was concordant with pre-operative imaging. The optical video successfully demonstrated the lymphatic drainage in real-time through a unique overlay fluorescence image. The ICG localized to the same nodes identified by both the SPECT-CT and hand-held SPECT images. The use of dual radiation and fluorescence tracers improved SN detection, especially for SN close to the injection site. The hand-held probes allowed the surgeon to dissect continuously, without needing to change tools. The combination of augmented reality, nuclear medicine, and over-lay fluorescence imaging allowed greater accuracy for matching the preoperative imaging with intraoperative identification and precisely guiding the dissection. This method uniquely permitted the surgeon to efficiently dissect the SN with accurate visualization and optimal precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrating very-high-resolution imagery, Sentinel-2 time-series data, and machine learning to map shrub fractional abundance across arid and semi-arid ecosystems in China

Shrub fractional abundance (SFA), the proportion of shrub cover per unit area, serves as a critical indicator of environmental aridity and ecosystem health in arid and semi-arid regions, particularly across the Mongolian steppe. However, large-scale SFA mapping in Mongolian steppe ecosystems remains challenging due to the small crown size of shrubs, their sparse distribution, and spectral overlap with coexisting low vegetation (e.g., grasses and herbs), which hinders accurate detection using coarser-resolution satellite data or traditional field surveys. To address these challenges, we developed a two-step approach that integrates very-high-resolution (VHR) imagery, time-series Sentinel-2 data, and deep learning techniques. First, we generated high-accuracy benchmark maps of individual shrub crowns from 0.5 m VHR imagery by combining manual segmentation with a hybrid deep learning framework (Dino V2 and convolutional neural networks). Second, we used these shrub crown maps as training data to build an XGBoost model for predicting SFA from 20 m Sentinel-2 time-series data, leveraging phenological information to improve estimation. We validated our approach across 70 sites (1km 2 each) in the Inner Mongolia Autonomous Region, which is representative of Mongolian steppe ecosystems. From VHR imagery, we mapped 1.31 million shrub crowns with an accuracy of R 2 = 0.92. Scaling up with Sentinel-2 data yielded regional SFA maps with an R 2 = 0.60. Further SHAP (SHapley Additive exPlanations) analysis on the developed XGBoost model revealed that phenological metrics (particularly observations in early-May, mid-July, and late-September), which distinguish shrub phenology from that of other land cover types (e.g., grasses and bare soil), were the most influential predictors of SFA. Finally, our regional SFA maps uncovered unimodal relationships between shrub distribution and climate variables, peaking at mean annual minimum temperatures near 0 °C and annual precipitation around 200 mm. Collectively, these findings demonstrate how the integration of multi-source remote sensing and machine learning can overcome historical limitations in SFA mapping, enabling accurate, spatially continuous assessments across vast Inner-Mongolian steppe ecosystems. Our framework has the potential to be applied to other steppe ecosystems and dryland ecosystems across the Mongolian steppe and beyond, offering a foundation for improved monitoring and ecological impact assessments in the face of global climate changes.

Arid and semi-arid landscapes↗

A compact filtered x-ray diode array spectrometer for the National Ignition Facility: SENTINEL

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ~1 keV–20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight—an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. Here, we present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×–25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

47 OTHER INSTRUMENTATION↗

Low Risk of Development of a Regional Recurrence After an Unsuccessful Repeat Sentinel Lymph Node Biopsy in Patients with Ipsilateral Breast Tumor Recurrence

Background: Unlike sentinel lymph node biopsy (SLNB) in the primary setting, the repeat SLNB (rSLNB) in patients with ipsilateral breast tumor recurrence (IBTR) is challenging, because it is difficult to visualize and/or harvest a sentinel lymph node in every patient. Regional treatments options and safety in terms of regional disease control after such an unsuccessful rSLNB remain unclear. This study assesses factors associated with the performance of axillary lymph node dissection (ALND) after unsuccessful rSLNB and evaluates the occurrence of regional recurrences. Methods: Data were obtained from the Sentinel Node and Recurrent Breast Cancer (SNARB) study. In 239 patients, the rSLNB was unsuccessful, of whom 60 patients underwent ipsilateral ALND. Results: A shorter time interval between primary treatment and IBTR, and a primary negative SLNB were significantly associated with a higher probability to be treated with ALND after unsuccessful rSLNB (P < 0.001). The 5-year regional-recurrence rate was 0.0% in the ALND group compared with 3.7% in the group treated without ALND (P = 0.113). Of the 179 patients treated without ALND, after a median follow-up of 5.1 years (range 0.3–13.2), 7 (3.9%) developed a regional recurrence as first event after unsuccessful rSLNB. None of the seven recurrences occurred in the ipsilateral axilla. Univariable analysis showed no factors associated with regional recurrence as first event after unsuccessful rSLNB (P > 0.05). Conclusions: The present study demonstrates that the risk of regional recurrence in patients with an IBTR and an unsuccessful rSLNB is negligible, irrespective of the use of ALND. This suggests that there is no need for additional treatment of the axilla after an unsuccessful rSLNB.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SentimagIC: A Non-inferiority Trial Comparing Superparamagnetic Iron Oxide Versus Technetium-99m and Blue Dye in the Detection of Axillary Sentinel Nodes in Patients with Early-Stage Breast Cancer

Background: Sentinel lymph node biopsy (SLNB) is a highly accurate method for staging the axilla in early breast cancer. Superparamagnetic iron oxide mapping agents have been explored to overcome the disadvantages of the standard SLNB technique, which uses a radioisotope tracer with or without blue dye. One such agent, Sienna+, was shown to be non-inferior to the standard technique for SLNB in a number of studies. The SentimagIC trial was designed to establish the non-inferiority of a new formulation of this magnetic tracer, Magtrace (formerly SiennaXP). Methods: Patients with clinically node-negative early-stage breast cancer were recruited from six centers in the US. Patients received radioisotope and isosulfan blue dye injections, followed by an intraoperative injection of magnetic tracer, prior to SLNB. The sentinel node identification rate was compared between the magnetic and standard techniques to evaluate non-inferiority and concordance. Results: Data were collected for 146 procedures in 146 patients. The per patient detection rate was 99.3% (145/146) when using the magnetic tracer and 98.6% (144/146) when using the standard technique, while the nodal detection rate was 94.3% (348/369 nodes) when using the magnetic tracer and 93.5% (345/369) when using the standard technique (difference 0.8%, 95% binomial confidence interval lower bound − 2.1%). Of the 22 patients with positive sentinel lymph nodes (SLNs), 21 (95.4%) were detected by both the magnetic tracer and the standard technique. All malignant nodes detected by standard technique were also identified by the magnetic technique. Conclusion: The magnetic technique is non-inferior to the standard technique of radioisotope and blue dye for axillary SLN detection in early-stage breast cancer. The magnetic technique is therefore a viable alternative.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensor sentinel computing device

Technologies pertaining to authenticating data output by sensors in an industrial environment are described herein. A sensor sentinel computing device receives time-series data from a sensor by way of a wireline connection. The sensor sentinel computing device generates a validation signal that is a function of the time-series signal. The sensor sentinel computing device then transmits the validation signal to a programmable logic controller in the industrial environment.

97 MATHEMATICS AND COMPUTING↗

Applicability of Sentinel-1 Terrain Observation by Progressive Scans multitemporal interferometry for monitoring slow ground motions in the San Francisco Bay Area

Data from the Sentinel-1 satellite have already proven useful for investigating seismic and volcanic events since its launch in April 2014. The requirement of ultrahigh coregistration accuracy and the current relatively short time of Sentinel-1 acquisitions make its application challenging for studying slow deformation processes, such as fault creep and land subsidence. Here in this paper we analyze a set of 14 SAR images over the San Francisco Bay Area spanning 1 year from early 2015 to 2016. We show that implementing an existing Enhanced Spectral Diversity algorithm or using precise orbits together with a reference digital elevation model both yield the required coregistration accuracy for making use of the phase measurements in time series analysis of ground deformation. Following a thorough validation test, we update our estimates of Hayward Fault creep rate and confirm uplift due to recharge of the Santa Clara Valley aquifer system during the final summer of 4 year drought.

58 GEOSCIENCES↗

Evaluation of camera-based freehand SPECT in preoperative sentinel lymph node mapping for melanoma patients

Assessment of lymphatic status via sentinel lymph node (SLN) biopsy is an integral and crucial part of melanoma surgical oncology. The most common technique for sentinel node mapping is preoperative planar scintigraphy of an injected gamma-emitting lymphatic tracer followed by intraoperative node localization using a non-imaging gamma probe with auditory feedback. In recent years, intraoperative visualization of SLNs in 3D has become possible by coupling the probe to an external system capable of tracking its location and orientation as it is read out, thereby enabling computation of the 3D distribution of the tracer (freehand SPECT). In this project, the non-imaging probe of the fhSPECT system was replaced by a unique handheld gamma camera containing an array of sodium iodide crystals optically coupled to an array of silicon photomultipliers (SiPMs). A feasibility study was performed in which preoperative SLN mapping was performed using camera fhSPECT and the number of detected nodes was compared to that visualized by lymphoscintigraphy, probe fhSPECT, and to the number ultimately excised under non-imaging probe guidance. Among five subjects, SLNs were detected in nine lymphatic basins, with one to five SLNs detected per basin. A basin-by-basin comparison showed that the number of SLNs detected using camera fhSPECT exceeded that using lymphoscintigraphy and probe fhSPECT in seven of nine basins and five of five basins, respectively. (Probe fhSPECT scans were not performed for four basins.) It exceeded the number excised under non-imaging probe guidance for seven of nine basins and equaled the number excised for the other two basins. Freehand SPECT using a prototype SiPM-based gamma camera demonstrates high sensitivity for detection of SLNs in a preoperative setting. Camera fhSPECT is a potential means for efficiently obtaining real-time 3D activity distribution maps in applications such as image-guided percutaneous biopsy, and surgical SLN biopsy or radioguided tumor excision.

60 APPLIED LIFE SCIENCES↗

Envisat Track 349 and Sentinel-1A Track 64 Interferometric Synthetic Aperture Radar Data of Coso Geothermal Field, California, USA, 2004-2016

This submission contains tarred pair directories for interferometric synthetic aperture radar (InSAR) data covering Coso Geothermal Field in California, USA. Explanation of pair subdirectories: Pairs are formed using the InSAR processing software GMT5SAR (Sandwell et al., 2011). Pair subdirectories are named by starting and ending epochs in YYYYMMDD_YYYYMMDD format. Each tarred pair directory contains GRD files for phase data (radians), unwrapped range change (drhomaskd, in m), and unwrapped range change rate (drange, in m/yr). The data are given in both latitude/longitude and Universal Transverse Mercator (Zone 11N). Raw Synthetic Aperture Radar (SAR) data from the Envisat satellite mission operated by the European Space Agency (ESA) are copyrighted by ESA and were provided through the WInSAR consortium at the UNAVCO facility. Raw Synthetic Aperture Radar (SAR) data from the Sentinel-1A satellite mission operated by ESA were available free of charge through the Distributed Active Archive Center (DAAC) at the Alaska Satellite Facility (ASF) and through the Sentinels Scientific Data Hub. References: Farr, T.G.; Rosen, P.A.; Caro, E.; Crippen, R.; Duren, R.; Hensley, S.; Kobrick, M.; Paller, M.; Rodriguez, E.; Roth, L.; Seal, D.; Shaffer, S.; Shimada, J.; Umland, J.; Werner, M.; Oskin, M.; Burbank, D.; Alsdorf, D. The Shuttle Radar Topography Mission. Reviews of Geophysics 2007, 45, RG2004. doi:10.1029/2005RG000183. Sandwell, D.; Mellors, R.; Tong, X.; Wei, M.; Wessel, P. Open radar interferometry software for mapping surface deformation. Eos, Transactions American Geophysical Union 2011, 92, 234?234. http://dx.doi.org/10.1029/2011EO280002. doi:10.1029/2011EO280002.

15 GEOTHERMAL ENERGY↗