Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor, radiation, Detection Material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High Density Nano-Electrode Array for Radiation Detection

Bulk single crystals of Cd1-xZnxTe (x=0.04 to x=0.2) compound semiconductor is used for room temperature radiation detection. The production of large volume of Cd1-xZnxTe with low defect density is expensive. As a result there is a growing research interest in the production of nanostructured compound semiconductors such as Cd1-xZnxTe in an electrochemical route. In this investigation, Cd1-xZnxTe ternary compound semiconductor, referred as CZT, was electrodeposited in the form of nanowires onto a TiO2 nanotubular template from propylene carbonate as the non-aqueous electrolyte, using a pulse-reverse electrodeposition process at 130 ºC. The template acted as a support in growing ordered nanowire of CZT which acts as a one dimensional conductor. Cyclic Voltammogram (CV) studies were conducted in determining the potentials for the growth of nanowires of uniform stoichiometry. The morphologies and composition of CZT were characterized by using SEM, TEM and XRD. The STEM mapping carried out on the nanowires showed the uniform distribution of Cd, Zn and Te elements. TEM image showed that the nanowires were polycrystalline in nature. The Mott-Schottky analysis carried on the nanowires showed that the nanowires were a p-type semiconductor. The carrier density, band gap and resistivity of the Cd0.9Zn0.1Te nanowires were 4.29x1013 cm-3, 1.56 eV and 2.76x1011Ω-cm respectively. The high resistivity was attributed to the presence of deep defect states such as cadmium vacancies or Te antisites which were created by the anodic cycle of the pulse-reverse electrodeposition process. Stacks of series connected CZT nanowire arrays were tested with different bias potentials. The background current was in the order of tens of picoamperes. When exposed to radiation source Amerecium-241 (60 KeV, 4 μCi), the stacked CZT nanowires arrays showed sensing behavior. The sensitivity of the nanowire arrays increased as the number of stacks increased. The preliminary results indicate that the CZT nanowire arrays can be used as a potential X-ray and low energy gamma ray detector material at room temperature with a much low bias potential (0.7 – 4V) as against 300 – 500 V applied in the commercial bulk detector materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation detection and situation management by distributed sensor networks

Detection of radioactive materials in an urban environment usually requires large, portal-monitor-style radiation detectors. However, this may not be a practical solution in many transport scenarios. Alternatively, a distributed sensor network (DSN) could complement portal-style detection of radiological materials through the implementation of arrays of low cost, small heterogeneous sensors with the ability to detect the presence of radioactive materials in a moving vehicle over a specific region. In this paper, we report on the use of a heterogeneous, wireless, distributed sensor network for traffic monitoring in a field demonstration. Through wireless communications, the energy spectra from different radiation detectors are combined to improve the detection confidence. In addition, the DSN exploits other sensor technologies and algorithms to provide additional information about the vehicle, such as its speed, location, class (e.g. car, truck), and license plate number. The sensors are in-situ and data is processed in real-time at each node. Relevant information from each node is sent to a base station computer which is used to assess the movement of radioactive materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Narrow-band radiation sensing in the terahertz and microwave bands using the radiation-induced magnetoresistance oscillations

Tuned narrow-band sensing of microwave and terahertz radiation can be realized by subjecting an irradiated two-dimensional electron system to both a static and a time varying magnetic field, and detecting at the harmonics of the modulation. A third harmonic sensor is considered here in conjunction with periodic-in-the-inverse-magnetic-field radiation-induced magnetoresistance oscillations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiation sensitive devices and systems for detection of radioactive materials and related methods

Radiation sensitive devices include a substrate comprising a radiation sensitive material and a plurality of resonance elements coupled to the substrate. Each resonance element is configured to resonate responsive to non-ionizing incident radiation. Systems for detecting radiation from a special nuclear material include a radiation sensitive device and a sensor located remotely from the radiation sensitive device and configured to measure an output signal from the radiation sensitive device. In such systems, the radiation sensitive device includes a radiation sensitive material and a plurality of resonance elements positioned on the radiation sensitive material. Methods for detecting a presence of a special nuclear material include positioning a radiation sensitive device in a location where special nuclear materials are to be detected and remotely interrogating the radiation sensitive device with a sensor.

36 MATERIALS SCIENCE↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Fusion for a Vision-Radiological System: a Statistical Calibration Algorithm

Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development of calibration algorithms for characterizing the fused sensor system as a single entity. There is an apparent need for correcting for a scene deviation from the basic inverse distance-squared law governing the detection rates even when evaluating system calibration algorithms. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked, to which the time-dependent radiological data can be incorporated by means of data fusion of the two sensors' output data. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of CLYC Detectors for a Next-Generation Unattended Sensor

We are developing a next-generation unattended sensor for detecting anomalous radiation sources. The system uses a scintillator material with dual sensitivity to gamma rays and neutrons, Cs 2 LiYCl 6 :Ce (CLYC), to reduce the size and complexity of the design. CLYC also offers a best-case energy resolution under 4% full width at half maximum at 662 keV, and allows for particle discrimination by pulse amplitude as well as pulse shape. The unattended sensor features sixteen one-inch CLYC detectors, each read out by a photomultiplier tube and custom readout electronics. A field-programmable gate array implements a suite of efficient processing algorithms for anomaly detection and isotope identification, and transmits alarm information to a base station via a wireless link. The system is designed to operate on battery power for several weeks. In this paper, we report the energy resolution, linearity, detection efficiency, and temperature stability of the first CLYC detectors acquired for the project. Rather than characterizing the scintillator material under ideal conditions, we evaluate the detectors with the components selected for the unattended sensor, acknowledging the tradeoffs imposed by small size, limited power budget, and uncontrolled environmental conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LYNX: An unattended sensor system for detection of gamma-ray and neutron emissions from special nuclear materials

This manuscript profiles an unattended and fully autonomous detection system sensitive to gamma-ray and neutron emissions from special nuclear material. The LYNX design specifically targets applications that require radiation detection capabilities but possess little or no infrastructure. In these settings, users need the capability to deploy sensors for extended periods of time that analyze whatever signal-starved data can be captured, since little or no control may be exerted over measurement conditions. The fundamental sensing elements of the LYNX system are traditional NaI(Tl) and 3He detectors. The new developments reported here center on two themes: low-power electronics and computationally simple analysis algorithms capable of discriminating gamma-ray signatures indicative of special nuclear materials from those of naturally occurring radioactive material. Incorporating tripwire-detection algorithms based on gamma-ray spectral signatures into a low-power electronics package significantly improves performance in environments where sensors encounter nuisance sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electron transport and charge induction in cadmium zinc telluride detectors with space charge build up under intense x-ray irradiation

Under intense x-ray irradiation, wide band gap semiconductor radiation detectors fabricated from crystals with low hole transport properties develop a steady-state space charge distribution that results from a dynamic equilibrium between charge carrier dynamics and the incident photon field. At a high enough x-ray flux, this space charge can collapse the electric field within the detector, resulting in the paralyzation of photon counting (i.e., high-flux polarization). However, well before polarization causes a catastrophic device failure, there can be enough space charge present to significantly modify the electric field. A modified field affects the electron transport and, therefore, signal generation within the sensor, which can ultimately degrade the performance of high-rate photon counting electronics. In this study, we analytically solve the fundamental equation of charge conservation to derive the modified electron transport in the presence of an exponential space charge distribution that results from the incident x-rays. We use these space-time solutions to calculate and study the time dependence of the resulting charge-induced signals. The predicted induced signals are compared throughout with numerical solutions of the full charge transport equation. In addition, we present analogous closed-form signals for a uniform distribution relevant to a broader class of {gamma}-ray applications. Finally, we use these solutions to derive a two-parameter family of modified Hecht curves that naturally predict a voltage offset that appears due to the space charge.

36 MATERIALS SCIENCE↗

Chalcogenide Glass Radiation Sensor; Materials Development, Design and Device Testing

For many decades, various radiation detecting material have been extensively researched, to find a better material or mechanism for radiation sensing. Recently, there is a growing need for a smaller and effective material or device that can perform similar functions of bulkier Geiger counters and other measurement options, which fail the requirement for easy, cheap and accurate radiation dose measurement. Here arises the use of thin film chalcogenide glass, which has unique properties of high thermal stability along with high sensitivity towards short wavelength radiation. The unique properties of chalcogenide glasses are attributed to the lone pair p-shell electrons, which provide some distinctive optical properties when compared to crystalline material. These qualities are derived from the energy band diagram and the presence of localized states in the band gap. Chalcogenide glasses have band tail states and localized states, along with the two band states. These extra states are primarily due to the lone pair electrons as well as the amorphous structure of the glasses. The localized states between the conductance band (CB) and valence band (VB) are primarily due to the presence of the lone pair electrons, while the band tail states are attributed to the Van der Waal's forces between layers of atoms. Localized states are trap locations within the band gap where electrons from the valence band can hop into, in their path towards the conduction band. Tail states on the other hand are locations near the band gap edges and are known as Urbach tail states (E u ). These states are occupied with many electrons that can participate in the various transformations due to interaction with photons. According to Y. Utsugi et. al., the electron-phonon interactions are responsible for the generation of the Urbach tails. These states are responsible for setting the absorption edge for these glasses and photons with energy near the band gap affect these states. We have studied the effect of x-rays and γ-rays, on thin film chalcogenide glasses and applied them in conjunction with film incorporating a silver source in a new type of radiation sensor for which we have an US patent application. In this report, we give data about our studies regarding our designed radiation sensor along with the testing and performance at various radiation doses. These studies have been preceded by materials characterization research related to the compositional and structural characteristics of the active materials used in the radiation sensor design. During the work on the project, we collected a large volume of material since every experiment was repeated many times to verify the results. We conducted a comprehensive material research, analysis and discussion with the aim to understand the nature of the occurring effects, design different structures to harness these effects, generated models to aid in the understanding the effects, built different device structures and collected data to quantify device performance. These various aspects of our investigation have been detailed in previous quarterly reports. In this report, we present our main results and emphasize on the results pertaining to the core project goals materials development, sensor design and testing and with an emphasis on classifying the appropriate material and design for the optimal application. The report has three main parts: (i) Presentation of the main data; (ii) Bulleted summary of the most important results; (iii) List of the patent, journal publications, conference proceedings and conferences participation, occurring as a result of working on the project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wireless radiation sensor

Disclosed is a sensor for detecting radiation. The sensor includes a ferromagnetic metal and a radiation sensitive material coupled to the ferromagnetic metal. The radiation sensitive material is operable to change a tensile stress of the ferromagnetic metal upon exposure to radiation. The radiation is detected based on changes in the magnetic switching characteristics of the ferromagnetic metal caused by the changes in the tensile stress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomaly Detection in Radiation Sensor Data with Applications to Transportation Security

In this paper, we present a new approach for detecting trucks transporting illicit radioactive materials using radiation data. The approach is motivated by the high number of false alarms that typically results when using radiation portal monitors. Our approach is a three-stage anomaly detection process that consists of transforming the radiation sensor data into wavelet coefficients, representing the transformed data in binary form, and detecting anomalies among data sets using a proximity-based method. The approach is evaluated using simulated radiation data, and the results are encouraging. From a transportation security perspective, our results indicate that the concomitant use of gross count and spectroscopy radiation data improves identification of trucks transporting illicit radioactive materials. The results also suggest that the use of additional heterogeneous data with radiation data may enhance the reliability of the detection process. Further testing with real radiation data and mixture of cargo is needed to fully validate the results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MRDIS Case Study

The Mobile Radiation Detection and Identification System (MRDIS) is a large mobile scanner that inspects containers in transit from cargo ships for radiological materials. The MRDIS platform operates as a two-part system with one MRDIS using a plastic Polyvinyl Toleune (synthetic polymer) for primary detection and another MRDIS that uses spectroscopic detectors for secondary isotopic identification. MRDIS can operate either independently or as part of a team, depending on the needs of the port. MRDIS is controlled by a human operator, who searches the computer monitor for any traces of radiological materials when the containers pass through the center of the system. Each MRDIS can also feed data into a central system or collect data on its own for additional material analysis. The system integrates radiation detection, radioisotope identification, an optical character recognition system, occupancy/speed sensors, wireless communications, and data processing capabilities to discern what specific radiological materials are of particular interest. In addition, Sandia engineers created a detailed set of requirements for subsequent models, allowing for faster implementation of additional detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final LDRD report : development of advanced UV light emitters and biological agent detection strategies.

We present the results of a three year LDRD project which has focused on the development of novel, compact, ultraviolet solid-state sources and fluorescence-based sensing platforms that apply such devices to the sensing of biological and nuclear materials. We describe our development of 270-280 nm AlGaN-based semiconductor UV LEDs with performance suitable for evaluation in biosensor platforms as well as our development efforts towards the realization of a 340 nm AlGaN-based laser diode technology. We further review our sensor development efforts, including evaluation of the efficacy of using modulated LED excitation and phase sensitive detection techniques for fluorescence detection of bio molecules and uranyl-containing compounds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of local-power-free, remote α -particle detection using optical fibers

We demonstrate the application of fluorescence optical fiber coupled to a telecom grade fiber as a sensor for alpha particles using alpha-specific ZnS(Ag) scintillation materials whose wavelength is down-shifted into a low-loss region of the telecom grade fiber transmission band. Telecom-grade fiber optics offer a solution for sensing alpha radiation in deep repositories and cask storage for radioactive materials due to the stability of SiO 2 under normal environmental conditions and its relative radiation hardness at low radiation doses. Long-term nuclear waste storage facilities require sensors for the detection of leakage of radioactive materials that are maintenance-free, do not require power and can survive with no ‘wear out’ mechanisms for decades. By accomplishing the wavelength transformation, we maximize efficiencies in the detection of α-particles and signal transport and can detect alpha scintillation at distances on the order of >1 km with a sensor that is ~3% efficient and can be easily scaled as a sensor array. This paper describes the construction and testing of the sensor including manufacture of the controlled thickness films, verification of the wavelength shift from 450 to 620 nm and optimization of the sensitivity as a function of thickness. We also model the relative sensitivity of the film as a function of film thickness, and we demonstrate a signal-to-noise ratio of 10 at a range of greater than 1 km.

alpha particles↗

Design of Dual-Road Transportable Portal Monitoring System for Visible Light and Gamma-Ray Imaging

The use of radiation sensors as portal monitors is increasing due to heightened concerns over the smuggling of fissile material. Transportable systems that can detect significant quantities of fissile material that might be present in vehicular traffic are of particular interest, especially if they can be rapidly deployed to different locations. To serve this application, we have constructed a rapid-deployment portal monitor that uses visible-light and gamma-ray imaging to allow simultaneous monitoring of multiple lanes of traffic from the side of a roadway. The system operation uses machine vision methods on the visible-light images to detect vehicles as they enter and exit the field of view and to measure their position in each frame. The visible-light and gamma-ray cameras are synchronized which allows the gamma-ray imager to harvest gamma-ray data specific to each vehicle, integrating its radiation signature for the entire time that it is in the field of view. Thus our system creates vehicle-specific radiation signatures and avoids source confusion problems that plague non-imaging approaches to the same problem. Our current prototype instrument was designed for measurement of upto five lanes of freeway traffic with a pair of instruments, one on either side of the roadway. Stereoscopic cameras are used with a third alignment camera for motion compensation and are mounted on a 50 deployable mast. In this paper we discuss the design considerations for the machine-vision system, the algorithms used for vehicle detection and position estimates, and the overall architecture of the system. We also discuss system calibration for rapid deployment. We conclude with notes on preliminary performance and deployment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New Radiological Material Detection Technologies for Nuclear Forensics: Remote Optical Imaging and Graphene-Based Sensors

We developed new detector technologies to identify the presence of radioactive materials for nuclear forensics applications. First, we investigated an optical radiation detection technique based on imaging nitrogen fluorescence excited by ionizing radiation. We demonstrated optical detection in air under indoor and outdoor conditions for alpha particles and gamma radiation at distances up to 75 meters. We also contributed to the development of next generation systems and concepts that could enable remote detection at distances greater than 1 km, and originated a concept that could enable daytime operation of the technique. A second area of research was the development of room-temperature graphene-based sensors for radiation detection and measurement. In this project, we observed tunable optical and charged particle detection, and developed improved devices. With further development, the advancements described in this report could enable new capabilities for nuclear forensics applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensor Placement Optimization Study for the Built Environment: Operational Use Cases

Systems of fixed-position radiation sensors can provide information that assists emergency responders following nuclear and radiological incidents. State, local, tribal, and territorial (SLTT) government agencies that implement systems of fixed-position sensors are faced with numerous decisions regarding sensor selection, quantity, and placement. To develop guidance on implementation of radiation detection systems, we simulated the release of radioactive material in an urban environment using a combination of three models: the Weather Research Forecasting (WRF), Quick Urban and Industrial Complex (QUIC), and Monte Carlo N-Particle (MCNP) models. We then evaluated the performance of several hypothetical sensor systems. The small number of simulations we conducted are not sufficient to generate definitive design guidance for radiation sensor systems, but we did identify trends that would be of interest to emergency planners. For a scenario that releases 1000 curies of Cs-137, radiation detectors were needed at 500-meter intervals to have a high likelihood of event detection and to estimate source location and plume detection. We also noted that optimal detector altitude varied with distance to the source. We recommend additional research in this area be conducted to support developing sensor placement guidelines that expand on a range of locations, isotopes, activity levels, and different weather conditions. Original simulation strategies included a range of environments, additional radioisotopes (Am241 and AmBe), and a larger selection of sensor types. These types of expansions would support SLTT guidance on sensor system recommendations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗