Studying Microbial Adaptation in the Laboratory: Sensor & Control Upgrades for an Experimental Evolution Biofluidics System

Experimental evolution (EE) involves iteratively exposing a microbial community to specific stressors to study its response to changes in environment over time. EE work is commonly done manually in the laboratory, but, when there are many environmental variables to measure and adjust, it is highly labor intensive, prone to human error, and challenging to scale. Single-purpose automated continuous culturing chambers exist, but implement only limited stressor types. A more general-purpose design is desirable. The BeING Lab at Ames Research Center created the prototype Automated Adaptive Directed Evolution Chamber (AADEC) to address these problems, beginning with Escherichia coli tolerance of short-wave ultraviolet (UV-C) radiation and of temperature. In newer versions, AADEC monitors microbial activity and can adjust the UV-C and temperature levels automatically. An optical density measurement is used to determine how many cells are present in the growth medium—over time, this corresponds to how many survive and reproduce. Oxidation-reduction potential provides information on consumed metabolic energy, and pH and electrical conductivity on metabolic products. Dissolved oxygen content is used to determine aerobic vs anaerobic growth. A Raspberry Pi computer processes all this data to set the UV-C stressor level. AADEC’s auxiliary systems include peristaltic pumps to change media and agitation to counteract cell settling. These actuators can also act as additional stressors. With the Raspberry Pi monitoring sensors and adjusting actuators in real time, AADEC takes measurements and controls the environment much more accurately than can be done with a manual EE implementation. The third and latest AADEC iteration is the first to simplify design and usage with circuits on PCBs and the ability to pre-program experimental protocols. Still planned is expansion to a multi-well design for the study of varying cell cultures in parallel, which will enable researchers to retain and re-inoculate cultures exhibiting the desired trait most strongly while flushing out others. AADEC’s special capabilities make it a valuable tool for studying life under multiple stressors, enabling scientists to replicate changes in climate on microbes for study in a lab setting.

Microbial Adaptation↗

Remodeling BioSentinel’s Microbial Metabolism Measurement System

BioSentinel, the first biological CubeSat beyond low Earth orbit, will investigate how Saccharomyces cerevisiae responds to ionizing radiation using optical measurements of a colorimetric metabolic indicator dye (alamarBlue). To map optical data to more detailed metabolic measurements, a microbial culture system for ground testing was designed consisting of a 400 mL beaker and a rubber stopper with pass-through holes for its five sensor probes (electrical conductivity, pH, oxidation-reduction potential, dissolved oxygen, optical density). The initial design had several drawbacks. It was only partially reusable due to its one-time sealants: Teflon tape and parafilm. A steady increase in oxygen levels within the sensor’s testingdata indicated the design was not sufficiently airtight. Degradation of the rubber stopper’s elasticity due to sterilization and reinsertion of the probes led to poor robustness and eventual replacement. The vessel’s large headspace didn’t reproduce flight conditions and a large culture volume required more reagents. The system has been redesigned to contain a rigid, biocompatible polycarbonate disc lid that allows for threaded inserts. The culture vessel’s height will be reduced from 110 mm to 65 mm to decrease overhead space and material costs. A more reliable seal will be achieved with a gasket and clamps. The optical probe records absorbance at four wavelengths to characterize cell density and alamarBlue dye ratios. A pneumatically operated plunger draws media through the hollow interior of the probe. Currently, deformation of the silicone on the plunger causes asymmetrical movement and a drift from its initial state. Designs are being developed to limit the plunger’s travel for a more accurate measurement cycle. The remodeled system is under construction and will be tested for leaks and accuracy. The measurements collected will be used to provide additional insight into the optical data returned from the BioSentinel mission.

Astrobiology↗

Chemical sensors for space applications

The payload of the Space Station Freedom will include sensors for frequent monitoring of the water recycling process and for measuring the many biochemical parameters related to onboard experiments. This paper describes the sensor technologies and the types of transducers and selectors considered for these sensors. Particular attention is given to such aspects of monitoring of the water recycling process as the types of water use, the sources of water and their hazards, the sensor systems for monitoring, microbial monitoring, and monitoring toxic metals and organics. An approach for monitoring water recycling is suggested, which includes microbial testing with a potentiometric device (which should be in first line of tests), the use of an ion-selective electrode for inorganic ion determinations, and the use of optic fiber techniques for the determination of total organic carbon.

Bonting, Sjoerd L.↗

Microbial biofilm formation and its consequences for the CELSS program

A major goal of the Controlled Ecology Life Support System (CELSS) program is to provide reliable and efficient life support systems for long-duration space flights. A principal focus of the program is on the growth of higher plants in growth chambers. These crops should be grown without the risk of damage from microbial contamination. While it is unlikely that plant pathogens will pose a risk, there are serious hazards associated with microorganisms carried in the nutrient delivery systems and in the atmosphere of the growth chamber. Our experience in surface microbiology showed that colonization of surfaces with microorganisms is extremely rapid even when the inoculum is small. After initial colonization extensive biofilms accumulate on moist surfaces. These microbial films metabolize actively and slough off continuously to the air and water. During plant growth in the CELSS program, microbial biofilms have the potential to foul sensors and to plug nutrient delivery systems. In addition both metabolic products of microbial growth and degradation products of materials being considered for use as nutrient reservoirs and for delivery are likely sources of chemicals known to adversly affect plant growth.

Mitchell, R.↗

Medusa Sea Floor Monitoring System

The objective of the research described in this poster presentation is to develop technologies to enable fundamental research into understanding the potential for and limits to chemolithoautotrophic life. The Medusa Isosampler (isobaric sampler), for sampling fluids eminating from deep sea hydrothermal vents and cold seep sites analogous to extraterrestrial environments, is described by the presentation. The following instruments are integrated with the isosampler, and also described: in situ flow-through chemical sensor, intrinsic fluorescent-based microbial detector, isotope ratio spectral detector.

Flynn, Michael↗

Enabling Experimental Evolution: Multi-Parameter Sensor System Integration into a Culture/Stressor Biofluidics System

Experimental evolution (EE) exposes microbial communities to ecological stressors, simulating dynamics up to near-extinction events. Combined with comparative sequencing and other molecular tools, such data can inform the genetic and other biological mechanisms underlying extremophile adaptation, and other observed effects. Automating this type of experiment using biofluidics can mitigate many traditional obstacles, including delays in assay results and environment adjustment and the need for many replicates. A first-generation device for automating EE procedures, the Automated Adaptive Directed Evolution Chamber (AADEC), was developed at NASA Ames. UV-C radiation was the stressor, an LED-photodiode array measured optical density, magnetic agitation and peristaltic pump systems ensured nutrient availability, and Arduino microcontrollers provided control. Escherichia coli in LB kanamycin media was used for testing and performance verification. A manual laboratory procedure with timed exposure to UV-C was performed to typify tolerance acquisition. Approximately a 106 factor increase in survival ratio was recorded over multiple iterations. Currently, a second-generation device is being developed integrating more real-time sensors: redox potential (ORP), indicating available/consumed metabolic energy; dissolved oxygen (DO), indicating aerobic/anaerobic growth; pH, indicating metabolic products; and electrical conductivity (EC), another indicator of metabolic products. The EC sensor system was constructed and calibrated in-house and matched commercial sensors in the required range. A Raspberry Pi computer automated the electrical system, allowing real-time data acquisition. The fluidics card was made of CNC-milled polycarbonate for biocompatibility. Each sensor parameter can also be used as a selection pressure alone or in combination with others to create extreme microbial environments. As a proof of concept, this work demonstrated sensor operation in one pair of growth-sensor chambers. It can be expanded to a multi-chamber system to enable inter-culture comparisons and multi-population studies. The prior Arduino system will be ported to the RPi system. Future stressors to be added include thermal, reactive oxygen species, and varying nutrient availability.

Govinda Raj, Chinmayee↗

ECLSS Integration Analysis: Advanced ECLSS Subsystem and Instrumentation Technology Study for the Space Exploration Initiative

In his July 1989 space policy speech, President Bush proposed a long range continuing commitment to space exploration and development. Included in his goals were the establishment of permanent lunar and Mars habitats and the development of extended duration space transportation. In both cases, a major issue is the availability of qualified sensor technologies for use in real-time monitoring and control of integrated physical/chemical/biological (p/c/b) Environmental Control and Life Support Systems (ECLSS). The purpose of this study is to determine the most promising instrumentation technologies for future ECLSS applications. The study approach is as follows: 1. Precursor ECLSS Subsystem Technology Trade Study - A database of existing and advanced Atmosphere Revitalization (AR) and Water Recovery and Management (WRM) ECLSS subsystem technologies was created. A trade study was performed to recommend AR and WRM subsystem technologies for future lunar and Mars mission scenarios. The purpose of this trade study was to begin defining future ECLSS instrumentation requirements as a precursor to determining the instrumentation technologies that will be applicable to future ECLS systems. 2. Instrumentation Survey - An instrumentation database of Chemical, Microbial, Conductivity, Humidity, Flowrate, Pressure, and Temperature sensors was created. Each page of the sensor database report contains information for one type of sensor, including a description of the operating principles, specifications, and the reference(s) from which the information was obtained. This section includes a cursory look at the history of instrumentation on U.S. spacecraft. 3. Results and Recommendations - Instrumentation technologies were recommended for further research and optimization based on a consideration of both of the above sections. A sensor or monitor technology was recommended based on its applicability to future ECLS systems, as defined by the ECLSS Trade Study (1), and on whether its characteristics were considered favorable relative to similar instrumentation technologies (competitors), as determined from the Instrumentation Survey (2). The instrumentation technologies recommended by this study show considerable potential for development and promise significant returns if research efforts are invested.

Source record↗

Development of a chemiluminescent and bioluminescent system for the detection of bacteria in wastewater effluent

Automated chemiluminescent and bioluminescent sensors were developed for continuous monitoring of microbial levels in wastewater effluent. Development of the chemiluminescent system included optimization of reagent concentrations as well as two new techniques which will allow for increased sensitivity and specificity. The optimal reagent concentrations are 0.0025 M luminol and 0.0125 M sodium perborate in 0.75N sodium hydroxide before addition of sample. The methods developed to increase specificity include (1) extraction of porphyrins from bacteria collected in a filter using 0.1N NaOH - 50 percent Ethanol, and (2) use of the specific reaction rate characteristics for the different luminol catalysts. Since reaction times are different for each catalyst, the reaction can be made specific for bacteria by measuring only the light emission from the particular reaction time zone specific for bacteria. Developments of the bioluminescent firefly luciferase system were in the area of flow system design.

Thomas, R. R.↗

Biological water quality monitoring using chemiluminescent and bioluminescent techniques

Automated chemiluminescence and bioluminescence sensors were developed for the continuous monitoring of microbial levels in water supplies. The optimal chemical procedures were determined for the chemiluminescence system to achieve maximum sensitivity. By using hydrogen peroxide, reaction rate differentiation, ethylene diamine tetraacetic acid (EDTA), and carbon monoxide pretreatments, factors which cause interference were eliminated and specificity of the reaction for living and dead bacteria was greatly increased. By employing existing technology with some modifications, a sensitive and specific bioluminescent system was developed.

Thomas, R. R.↗

Electronic Tongue Containing Redox and Conductivity Sensors

The Electronic Tongue (E-tongue 2) is an assembly of sensors for measuring concentrations of metal ions and possibly other contaminants in water. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings, and detecting micro-organisms indirectly by measuring microbially influenced corrosion. The device includes a heater, a temperature sensor, an oxidation/reduction (redox) sensor pair, an electrical sensor, an array of eight galvanic cells, and eight ion-specific electrodes.

Buehler, Martin↗

Initial Trade Study for In-line Silver Sensor for Spacecraft Potable Water Systems

Ionic silver is currently baselined as the biocide for microbial control in potable water systems for future space exploration missions. In-line monitoring of silver ion concentration is desired for system feedback control to introduce and maintain sufficient and safe levels of biocide in the water. To date, NASA testing of silver biocide system prototypes has made use of an Ion-Selective Electrode (ISE) for in-line silver concentration measurements. However, known issues with ISE technology have continued to motivate a search for alternate sensor systems. Although devices capable of detecting silver are available for terrestrial applications, these systems are generally not well-suited for the unique demands of spaceflight. Desired attributes include: low weight, volume, and power consumption; stable, autonomous, and in-line measurement capability; long calibration lifetime; and limited maintenance requirements. This paper provides the results from a preliminary trade study conducted on three candidate silver sensor technologies: ISEs, Anodic Stripping Voltammetry (ASV), and Fiber Optic Chemical Sensors (FOCS). The review of these technologies includes the rationale for their selection, an overview of the principles of their operation, and a detailed assessment of their strengths and weaknesses relative to the anticipated requirements of future spacecraft applications. The study concluded that none of the currently-available versions of these technologies is suitable for immediate application to spacecraft systems; further technology development should be considered. To that end, recommendations for forward development work have been proposed and provided herein.

Potable Water↗

NASA Tech Briefs, December 2011

Topics covered include: 1) SNE Industrial Fieldbus Interface; 2) Composite Thermal Switch; 3) XMOS XC-2 Development Board for Mechanical Control and Data Collection; 4) Receiver Gain Modulation Circuit; 5) NEXUS Scalable and Distributed Next-Generation Avionics Bus for Space Missions; 6) Digital Interface Board to Control Phase and Amplitude of Four Channels; 7) CoNNeCT Baseband Processor Module; 8) Cryogenic 160-GHz MMIC Heterodyne Receiver Module; 9) Ka-Band, Multi-Gigabit-Per-Second Transceiver; 10) All-Solid-State 2.45-to-2.78-THz Source; 11) Onboard Interferometric SAR Processor for the Ka-Band Radar Interferometer (KaRIn); 12) Space Environments Testbed; 13) High-Performance 3D Articulated Robot Display; 14) Athena; 15) In Situ Surface Characterization; 16) Ndarts; 17) Cryo-Etched Black Silicon for Use as Optical Black; 18) Advanced CO2 Removal and Reduction System; 19) Correcting Thermal Deformations in an Active Composite Reflector; 20) Umbilical Deployment Device; 21) Space Mirror Alignment System; 22) Thermionic Power Cell To Harness Heat Energies for Geothermal Applications; 23) Graph Theory Roots of Spatial Operators for Kinematics and Dynamics; 24) Spacesuit Soft Upper Torso Sizing Systems; 25) Radiation Protection Using Single-Wall Carbon Nanotube Derivatives; 26) PMA-PhyloChip DNA Microarray to Elucidate Viable Microbial Community Structure; 27) Lidar Luminance Quantizer; 28) Distributed Capacitive Sensor for Sample Mass Measurement; 29) Base Flow Model Validation; 30) Minimum Landing Error Powered-Descent Guidance for Planetary Missions; 31) Framework for Integrating Science Data Processing Algorithms Into Process Control Systems; 32) Time Synchronization and Distribution Mechanisms for Space Networks; 33) Local Estimators for Spacecraft Formation Flying; 34) Software-Defined Radio for Space-to-Space Communications; 35) Reflective Occultation Mask for Evaluation of Occulter Designs for Planet Finding; and 36) Molecular Adsorber Coating

Source record↗

BioNutrients-3: Precision Fermentation, Pasteurization, and Pathogen Detection - Towards Safe Fermentation and Production of Nutrients in Space

The BioNutrients (BN) project is developing a microbial manufacturing approach to supplement the NASA food system to address known nutrient degradation associated with long-term storage. BN uses synthetic biology to deliver high-value nutrients and therapeutics through genetic engineering of microbes and production of fermented food products like yogurt and kefir, in a fully dehydrated system. On-demand production of nutrients for human consumption requires rigorous safety protocols to ensure contaminants are not introduced during the fermentation process. The third iteration of the BN flight project, BN-3, further develops the BN project by investigating strategies for pathogen detection and pasteurization in microgravity. BN-3 will test the limits of pathogen detection using whole genome sequencing, standard microbial assays and the NASA Ames E-Nose, a volatile carbon nano tube-based sensor array, to detect unwanted microbes. BN-3 also expands on the number of nutrients produced in a single bioreactor to enhance efficiency of the system by combining production of B vitamins in conjunction with the carotenoids, beta-carotene and zeaxanthin. Serial production of food products through yogurt passaging, new updates to the fluorinated ethylene propylene bags to allow crew access via a straw, as well as use of a food safe pH indicator dye to indicate readiness of the food product, will further enhance the useability of this system. This presentation will provide status of the BN-3 flight project with the aim of advancing in-space biomanufacturing for on-demand microbially based food production for future space exploration.

Biomanufacturing↗

Tracking Metabolic Changes in Microbial Culture using Redox Measurements

During long-term space missions, microbial cultures accumulate the effects of low-dose radiation, microgravity, and other factors; altered growth and metabolic activity may occur before viability effects. This could affect functionality of bioreactors or other bio-enabled mission systems, as well as shed light on human health. Spaceflight microbiology studies beyond the low Earth orbit exposure afforded by the ISS have been limited. Nanosatellites offer an increasingly popular alternative for deep space missions. However, the communications delay requires biofluidic automation of a pre-defined experimental protocol, and the lack of sample return (reliance on sensors in flight) can significantly limit feasible investigations. Previous biological CubeSats (PharmaSat, O/OREOS, EcAMSat) have used alamarBlue, an off-the-shelf formulation of the redox indicator dye resazurin, to track metabolic activity, as will BioSentinel, the upcoming interplanetary microbiology experiment. A series of ground experiments (see abstracts by Liddell, Santa Maria, and A. Kim) were conducted using a microbial culture system outfitted with an electrochemical sensor array (electrical conductivity, pH, oxidation-reduction potential, and dissolved oxygen) with alamarBlue and the same strain of Saccharomyces cerevisiae as BioSentinel. By improving mapping of measured changes in alamarBlue kinetics to physicochemical changes, and ultimately to biological alterations such as shifted metabolic pathways, this work supplements data analyses from past missions and planning for future missions using alamarBlue to characterize space radiation effects. Initial results indicate that alamarBlue acts like a redox buffer; its presence significantly changes redox kinetics in otherwise identical cultures. The initial color change (blue resazurin reduced to red/pink resorufin) appears as a redox plateau. A second plateau, likely corresponding to the second color transition (resorufin to the colorless hydroresorufin), occurs at a lower redox value. The relationship to carbon source exhaustion, dissolved oxygen depletion, cell death, and measured redox potential is complex and still under study.

Tracking↗

Silver Electrolysis for Disinfection of Spacecraft Potable Water: 2024 Update

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of introducing biocidal silver into potable water on exploration spacecraft. This paper provides an update on the effort to implement this technology into a spacecraft potable water system. Previous papers reported on the feasibility of the technology for this application, strategies to prevent a potential fault condition termed “electrode bridging,” results from a preliminary investigation into the cathode reaction, and preliminary multiphysics modeling of the reactor. Since then, work has begun on the design of a next-generation silver electrolysis reactor prototype that will incorporate improvements identified in previous testing and package the reactor in a more flight-like configuration. This development effort has included additional testing to optimize the reactor design for prevention of electrode bridging, further investigation into the cathode reaction (including the use of a dissolved hydrogen sensor), and an assessment of the feasibility of using the reactor in other applications, such as for microbial shock and preparation for system dormancy.

silver biocide↗

Silver Electrolysis for Disinfection of Spacecraft Potable Water: 2024 Update

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of introducing biocidal silver into potable water on exploration spacecraft. This paper provides an update on the effort to implement this technology into a spacecraft potable water system. Previous papers reported on the feasibility of the technology for this application, strategies to prevent a potential fault condition termed “electrode bridging,” results from a preliminary investigation into the cathode reaction, and preliminary multiphysics modeling of the reactor. Since then, work has begun on the design of a next-generation silver electrolysis reactor prototype that will incorporate improvements identified in previous testing and package the reactor in a more flight-like configuration. This development effort has included additional testing to optimize the reactor design for prevention of electrode bridging, further investigation into the cathode reaction (including the use of a dissolved hydrogen sensor), and an assessment of the feasibility of using the reactor in other applications, such as for microbial shock and preparation for system dormancy.

silver biocide↗

Sensor Needs for Advanced Life Support

Sensors and feedback systems are critical to life support flight systems and life support systems research. New sensor capabilities can allow for new system architectures to be considered, and can facilitate dramatic improvements in system performance. This paper will describe three opportunities for biosensor researchers to develop sensors that will enable life support system improvements. The first opportunity relates to measuring physical, chemical, and biological parameters in the Space Station Water Processing System. Measuring pH, iodine, total organic carbon, microbiological activity, total dissolved solids, or conductivity with a safe, effective, stable, reliable microsensor could benefit the water processing system considerably. Of special interest is a sensor which can monitor biological contamination rapidly. The second opportunity relates to sensing microbiological contamination and water condensation on the surface of large inflatable structures. It is the goal of large inflatable structures used for habitation to take advantage of the large surface area of the structure and reject waste heat passively through the walls of the structure. Too much heat rejection leads to a cold spot with water condensation, and eventually microbiological contamination. A distributed sensor system that can measure temperature, humidity, and microbiological contamination across a large surface would benefit designers of large inflatable habitable structures. The third opportunity relates to sensing microbial bioreactors used for waste water processing and reuse. Microbiological bioreactors offer considerable advantages in weight and power compared to adsorption bed based systems when used for long periods of time. Managing and controlling bioreactors is greatly helped if distributed microsensors measured the biological populations continuously in many locations within the bioreactor. Nitrifying bacteria are of special interest to bioreactor designers, and any sensors that could measure the populations of these types of bacteria would help the control and operation of bioreactors. J

Graf, John C.↗

Electronic Tongue for Quantitation of Contaminants in Water

An assembly of sensors, denoted an electronic tongue, is undergoing development as a prototype of compact devices for use in measuring concentrations of contaminants in water. Thus far, the electronic tongue has been tested on ions of Cu, Zn, Pb, and Fe and shown to respond to concentrations as low as about 10 parts per million. This electronic tongue is expected to be capable of measuring concentrations of other metal ions and organic compounds. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings; detecting micro-organisms indirectly by measuring microbially influenced corrosion; and characterizing compounds of interest to the pharmaceutical and food industries. This version of the electronic tongue includes a heater, a temperature sensor, an array of ion-specific electrodes, an oxidation/ reduction sensor pair, an electrical-conductivity sensor, and an array of galvanic cells, all on one compact ceramic substrate. Special-purpose electronic excitation and readout circuitry for the sensors has also been constructed. The main advantage of the electronic tongue, relative to electrodes of this type used traditionally to assess water quality, is extreme ruggedness. The types of measurements that can be performed by use of the sensors on the electronic tongue are quite varied. The best combination of types of measurements for a given application depends on the specific contaminants that one seeks to detect. Experimental studies to identify such combinations were in progress at the time of reporting the information for this article.

Buehler, Marlin↗