Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensitivity and Specificity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Species-specific sensitivity to selenium-induced impairment of cortisol secretion in adrenocortical cells of rainbow trout (Oncorhynchus mykiss) and brook trout (Salvelinus fontinalis)

Species differences in physiological and biochemical attributes exist even among closely related species and may underlie species-specific sensitivity to toxicants. Rainbow trout (RT) are more sensitive than brook trout (BT) to the teratogenic effects of selenium (Se), but it is not known whether all tissues exhibit this pattern of vulnerability. In this study, primary cultures of RT and BT adrenocortical cells were exposed to selenite (Na{sub 2}SO{sub 3}) and selenomethionine (Se-Met) to compare cell viability and ACTH-stimulated cortisol secretion in the two fish species. Cortisol, the primary stress hormone in fish, facilitates maintenance of homeostasis when fish are exposed to stressors, including toxicants. Cell viability was not affected by Se, but selenite impaired cortisol secretion, while Se-Met did not (RT and BT EC{sub 50} > 2000 mg/L). RT cells were more sensitive (EC{sub 50} = 8.7 mg/L) to selenite than BT cells (EC{sub 50} = 90.4 mg/L). To identify the targets where Se disrupts cortisol synthesis, selenite-impaired RT and BT cells were stimulated with ACTH, dbcAMP, OH-cholesterol, and pregnenolone. Selenite acted at different steps in the cortisol biosynthesis pathway in RT and BT cells, confirming a species-specific toxicity mechanism. To test the hypothesis that oxidative stress mediates Se-induced toxicity, selenite-impaired RT cells were exposed to NAC, BSO and antioxidants (DETCA, ATA, Vit A, and Vit E). Inhibition of SOD by DETCA enhanced selenite-induced cortisol impairment, indicating that oxidative stress plays a role in Se toxicity; however, modifying GSH content of the cells did not have an effect. The results of this study, with two closely related salmonids, provided additional evidence for species-specific differences in sensitivity to Se which should be considered when setting thresholds and water quality guidelines. - Research Highlights: > We investigated species-specific sensitivity to Se in trout adrenocortical cells. > Selenite, not Se-Met, disrupts cortisol secretion in trout adrenocortical cells. > Rainbow trout cells are more sensitive than brook trout cells to selenite toxicity. > Superoxide dismutase may protect adrenocortical cells from selenite toxicity.

60 APPLIED LIFE SCIENCES↗

Odor exposure during imprinting periods increases odorant-specific sensitivity and receptor gene expression in coho salmon ( Oncorhynchus kisutch )

ABSTRACT Pacific salmon are well known for their homing migrations; juvenile salmon learn odors associated with their natal streams prior to seaward migration, and then use these retained odor memories to guide them back from oceanic feeding grounds to their river of origin to spawn several years later. This memory formation, termed olfactory imprinting, involves (at least in part) sensitization of the peripheral olfactory epithelium to specific odorants. We hypothesized that this change in peripheral sensitivity is due to exposure-dependent increases in the expression of odorant receptor (OR) proteins that are activated by specific odorants experienced during imprinting. To test this hypothesis, we exposed juvenile coho salmon, Oncorhynchus kisutch, to the basic amino acid odorant l-arginine during the parr–smolt transformation (PST), when imprinting occurs, and assessed sensitivity of the olfactory epithelium to this and other odorants. We then identified the coho salmon ortholog of a basic amino acid odorant receptor (BAAR) and determined the mRNA expression levels of this receptor and other transcripts representing different classes of OR families. Exposure to l-arginine during the PST resulted in increased sensitivity to that odorant and a specific increase in BAAR mRNA expression in the olfactory epithelium relative to other ORs. These results suggest that specific increases in ORs activated during imprinting may be an important component of home stream memory formation and this phenomenon may ultimately be useful as a marker of successful imprinting to assess management strategies and hatchery practices that may influence straying in salmon.

Dittman, Andrew H. (ORCID:000000016482359X)↗

Comparative Approach of MRI-Based Brain Tumor Segmentation and Classification Using Genetic Algorithm

The detection of a brain tumor and its classification from modern imaging modalities is a primary concern, but a time-consuming and tedious work was performed by radiologists or clinical supervisors. The accuracy of detection and classification of tumor stages performed by radiologists is depended on their experience only, so the computer-aided technology is very important to aid with the diagnosis accuracy. In this study, to improve the performance of tumor detection, we investigated comparative approach of different segmentation techniques and selected the best one by comparing their segmentation score. Further, to improve the classification accuracy, the genetic algorithm is employed for the automatic classification of tumor stage. The decision of classification stage is supported by extracting relevant features and area calculation. The experimental results of proposed technique are evaluated and validated for performance and quality analysis on magnetic resonance brain images, based on segmentation score, accuracy, sensitivity, specificity, and dice similarity index coefficient. The experimental results achieved 92.03% accuracy, 91.42% specificity, 92.36% sensitivity, and an average segmentation score between 0.82 and 0.93 demonstrating the effectiveness of the proposed technique for identifying normal and abnormal tissues from brain MR images. The experimental results also obtained an average of 93.79% dice similarity index coefficient, which indicates better overlap between the automated extracted tumor regions with manually extracted tumor region by radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-201-11: Sensitivity and Specificity of Verification Methods Based On Total Reference Air Kerma (TRAK) Or On User Provided Dose Points for Graphically Planned Skin HDR Brachytherapy

Purpose: To investigate the sensitivity and specificity of a novel verification methodology for image-guided skin HDR brachytherapy plans using a TRAK-based reasonableness test, compared to a typical manual verification methodology. Methods: Two methodologies were used to flag treatment plans necessitating additional review due to a potential discrepancy of 3 mm between planned dose and clinical target in the skin. Manual verification was used to calculate the discrepancy between the average dose to points positioned at time of planning representative of the prescribed depth and the expected prescription dose. Automatic verification was used to calculate the discrepancy between TRAK of the clinical plan and its expected value, which was calculated using standard plans with varying curvatures, ranging from flat to cylindrically circumferential. A plan was flagged if a discrepancy >10% was observed. Sensitivity and specificity were calculated using as a criteria for true positive that >10% of plan dwells had a distance to prescription dose >1 mm different than prescription depth (3 mm + size of applicator). All HDR image-based skin brachytherapy plans treated at our institution in 2013 were analyzed. Results: 108 surface applicator plans to treat skin of the face, scalp, limbs, feet, hands or abdomen were analyzed. Median number of catheters was 19 (range, 4 to 71) and median number of dwells was 257 (range, 20 to 1100). Sensitivity/specificity were 57%/78% for manual and 70%/89% for automatic verification. Conclusion: A check based on expected TRAK value is feasible for irregularly shaped, image-guided skin HDR brachytherapy. This test yielded higher sensitivity and specificity than a test based on the identification of representative points, and can be implemented with a dedicated calculation code or with pre-calculated lookup tables of ideally shaped, uniform surface applicators.

60 APPLIED LIFE SCIENCES↗

How Advances in Imaging Will Affect Precision Radiation Oncology

Radiation oncology is 1 of the most structured disciplines in medicine. It is of a highly technical nature with reliance on robotic systems to deliver intervention, engagement of diverse expertise, and early adoption of digital approaches to optimize and execute the application of this highly effective cancer treatment. As a localized intervention, the dependence on sensitive, specific, and accurate imaging to define the extent of disease, its heterogeneity, and adjacency to normal tissues directly affects the therapeutic ratio. Image-based in vivo temporal monitoring of the response to treatment enables adaptation and further affects the therapeutic ratio. Thus, more precise intervention will enable fractionation schedules that better interoperate with advances such as immunotherapy. In the data set–rich era that promises precision and personalized medicine, the radiation oncology field will integrate these new data into highly protocoled pathways of care that begin with multimodality prediction and enable patient-specific adaptation of therapy based on quantitative measures of the individual's dose–volume temporal trajectory and midtherapy predictions of response. In addition to advancements in computed tomography imaging, emerging technologies, such as ultra-high-field magnetic resonance and molecular imaging will bring new information to the design of treatments. Next-generation image guided radiation therapy systems will inject high specificity and sensitivity data and stimulate adaptive replanning. In addition, a myriad of pre- and peritherapeutic markers derived from advances in molecular pathology (eg, tumor genomics), automated and comprehensive imaging analytics (eg, radiomics, tumor microenvironment), and many other emerging biomarkers (eg, circulating tumor cell assays) will need to be integrated to maximize the benefit of radiation therapy for an individual patient. We present a perspective on the promise and challenges of fully exploiting imaging data in the pursuit of personalized radiation therapy, drawing from the presentations and broader discussions at the 2016 American Society of Therapeutic Radiation Oncology–National Cancer Institute workshop on Precision Medicine in Radiation Oncology (Bethesda, MD).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using support vector machine for improving protein-protein interaction prediction utilizing domain interactions

Understanding protein interactions is essential to gain insights into the biological processes at the whole cell level. The high-throughput experimental techniques for determining protein-protein interactions (PPI) are error prone and expensive with low overlap amongst them. Although several computational methods have been proposed for predicting protein interactions there is definite room for improvement. Here we present DomainSVM, a predictive method for PPI that uses computationally inferred domain-domain interaction values in a Support Vector Machine framework to predict protein interactions. DomainSVM method utilizes evidence of multiple interacting domains to predict a protein interaction. It outperforms existing methods of PPI prediction by achieving very high explanation ratios, precision, specificity, sensitivity and F-measure values in a 10 fold cross-validation study conducted on the positive and negative PPIs in yeast. A Functional comparison study using GO annotations on the positive and the negative test sets is presented in addition to discussing novel PPI predictions in Salmonella Typhimurium.

59 BASIC BIOLOGICAL SCIENCES↗

Reducing variability in the output of pattern classifiers using histogram shaping

Purpose: The authors present a novel technique based on histogram shaping to reduce the variability in the output and (sensitivity, specificity) pairs of pattern classifiers with identical ROC curves, but differently distributed outputs. Methods: The authors identify different sources of variability in the output of linear pattern classifiers with identical ROC curves, which also result in classifiers with differently distributed outputs. They theoretically develop a novel technique based on the matching of the histograms of these differently distributed pattern classifier outputs to reduce the variability in their (sensitivity, specificity) pairs at fixed decision thresholds, and to reduce the variability in their actual output values. They empirically demonstrate the efficacy of the proposed technique by means of analyses on the simulated data and real world mammography data. Results: For the simulated data, with three different known sources of variability, and for the real world mammography data with unknown sources of variability, the proposed classifier output calibration technique significantly reduced the variability in the classifiers' (sensitivity, specificity) pairs at fixed decision thresholds. Furthermore, for classifiers with monotonically or approximately monotonically related output variables, the histogram shaping technique also significantly reduced the variability in their actual output values. Conclusions: Classifier output calibration based on histogram shaping can be successfully employed to reduce the variability in the output values and (sensitivity, specificity) pairs of pattern classifiers with identical ROC curves, but differently distributed outputs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Engineering sensitivity and specificity of AraC-based biosensors responsive to triacetic acid lactone and orsellinic acid

Abstract We previously described the design of triacetic acid lactone (TAL) biosensor ‘AraC-TAL1’, based on the AraC regulatory protein. Although useful as a tool to screen for enhanced TAL biosynthesis, this variant shows elevated background (leaky) expression, poor sensitivity and relaxed inducer specificity, including responsiveness to orsellinic acid (OA). More sensitive biosensors specific to either TAL or OA can aid in the study and engineering of polyketide synthases that produce these and similar compounds. In this work, we employed a TetA-based dual-selection to isolate new TAL-responsive AraC variants showing reduced background expression and improved TAL sensitivity. To improve TAL specificity, OA was included as a ‘decoy’ ligand during negative selection, resulting in the isolation of a TAL biosensor that is inhibited by OA. Finally, to engineer OA-specific AraC variants, the iterative protein redesign and optimization computational framework was employed, followed by 2 rounds of directed evolution, resulting in a biosensor with 24-fold improved OA/TAL specificity, relative to AraC-TAL1.

Wang, Zhiqing↗

Dual-Energy CT Angiography in Peripheral Arterial Occlusive Disease

We sought to study the accuracy of dual-energy computed tomographic angiography (DE-CTA) for the assessment of symptomatic peripheral arterial occlusive disease of the lower extremity by using the dual-energy bone removal technique compared with a commercially available conventional bone removal tool. Twenty patients underwent selective digital subtraction angiography and DE-CTA of the pelvis and lower extremities. CTA data were postprocessed with two different applications: conventional bone removal and dual-energy bone removal. All data were reconstructed and evaluated as 3D maximum-intensity projections. Time requirements for reconstruction were documented. Sensitivity, specificity, accuracy, and concordance of DE-CTA regarding degree of stenosis and vessel wall calcification were calculated. A total of 359 vascular segments were analyzed. Compared with digital subtraction angiography, sensitivity, specificity, and accuracy, respectively, of CTA was 97.2%, 94.1%, and 94.7% by the dual-energy bone removal technique. The conventional bone removal tool delivered a sensitivity of 77.1%, a specificity of 70.7%, and an accuracy of 72.0%. Best results for both postprocessing methods were achieved in the vascular segments of the upper leg. In severely calcified segments, sensitivity, specificity, and accuracy stayed above 90% by the dual-energy bone removal technique, whereas the conventional bone removal technique showed a substantial decrease of sensitivity, specificity, and accuracy. DE-CTA is a feasible and accurate diagnostic method in the assessment of symptomatic peripheral arterial occlusive disease. Results obtained by DE-CTA are superior to the conventional bone removal technique and less dependent on vessel wall calcifications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Membrane-Extraction Ion Mobility Spectrometry for In-Situ Detection of Chlorinated Hydrocarbons in Water

Membrane-extraction ion mobility spectrometry (ME-IMS) has been developed for in-situ sampling and analysis of trace chlorinated hydrocarbons in water in a single procedure. The sampling is configured so that aqueous contaminants permeate through a spiral hollow polydimethylsiloxane (PDMS) membrane and are carried away by a vapor flow through the membrane tube. The extracted analyte flows into an atmospheric pressure chemical ionization (APCI) chamber and is analyzed in a home-made IMS analyzer. PDMS membrane is found to effectively extract chlorinated hydrocarbon solvents from liquid phase to vapor. The specialized IMS analyzer has been found to have resolutions of R=33 and 41, respectively, for negative- and positive-modes and is capable of detecting aqueous tetrachloroethylene (PCE) and trichloroethylene (TCE) as low as 80 g/L and 74 g/L in negative ion mode, respectively. The time-dependent characteristics of sampling and detection of TCE are both experimentally and theoretically studied for various concentrations, membrane lengths, and flow rates. These characteristics demonstrate that membrane-extraction IMS is feasible for the continuous monitoring of chlorinated hydrocarbons in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The use of ex vivo human skin tissue for genotoxicity testing

As a result of the chemical legislation concerning the registration, evaluation, authorization and restriction of chemicals (REACH), and the Seventh Amendment to the Cosmetics Directive, which prohibits animal testing in Europe for cosmetics, alternative methods for safety evaluation of chemicals are urgently needed. Current in vitro genotoxicity assays are not sufficiently predictive for the in vivo situation, resulting in an unacceptably high number of misleading positives. For many chemicals and ingredients of personal care products the skin is the first site of contact, but there are no in vitro genotoxicity assays available in the skin for additional evaluation of positive or equivocal responses observed in regulatory in vitro genotoxicity assays. In the present study ex vivo human skin tissue obtained from surgery was used for genotoxicity evaluation of chemicals by using the comet assay. Fresh ex vivo human skin tissue was cultured in an air–liquid interface and topically exposed to 20 chemicals, including true positive, misleading positive and true negative genotoxins. Based on the results obtained in the present study, the sensitivity, specificity and accuracy of the ex vivo skin comet assay to predict in vivo genotoxicity were 89%, 90% and 89%, respectively. Donor and experimental variability were mainly reflected in the magnitude of the response and not the difference between the presence and absence of a genotoxic response. The present study indicates that human skin obtained from surgery is a promising and robust model for safety evaluation of chemicals that are in direct contact with the skin. -- Highlights: ► We use human skin obtained from surgery for genotoxicity evaluation of chemicals. ► We use the comet assay as parameter for genotoxicity in ex vivo human skin. ► Sensitivity, specificity and accuracy to predict in vivo genotoxins are determined. ► Sensitivity, specificity and accuracy are 89%, 90% and 90%, respectively. ► The method is suitable for evaluation of chemicals that are in contact with skin.

60 APPLIED LIFE SCIENCES↗

A sensitive and specific genetically-encoded potassium ion biosensor for in vivo applications across the tree of life

Potassium ion (K + ) plays a critical role as an essential electrolyte in all biological systems. Genetically-encoded fluorescent K + biosensors are promising tools to further improve our understanding of K + -dependent processes under normal and pathological conditions. Here, we report the crystal structure of a previously reported genetically-encoded fluorescent K + biosensor, GINKO1, in the K + -bound state. Using structure-guided optimization and directed evolution, we have engineered an improved K + biosensor, designated GINKO2, with higher sensitivity and specificity. We have demonstrated the utility of GINKO2 for in vivo detection and imaging of K + dynamics in multiple model organisms, including bacteria, plants, and mice.

59 BASIC BIOLOGICAL SCIENCES↗

TU-C-12A-12: Differentiating Bone Lesions and Degenerative Joint Disease in NaF PET/CT Scans Using Machine Learning

Purpose: [F-18]NaF PET can be used to image bone metastases; however, tracer uptake in degenerative joint disease (DJD) often appears similar to metastases. This study aims to develop and compare different machine learning algorithms to automatically identify regions of [F-18]NaF scans that correspond to DJD. Methods: 10 metastatic prostate cancer patients received whole body [F-18]NaF PET/CT scans prior to treatment. Image segmentation resulted in 852 ROIs, 69 of which were identified by a nuclear medicine physician as DJD. For all ROIs, various PET and CT textural features were computed. ROIs were divided into training and testing sets used to train eight different machine learning classifiers. Classifiers were evaluated based on receiver operating characteristics area under the curve (AUC), sensitivity, specificity, and positive predictive value (PPV). We also assessed the added value of including CT features in addition to PET features for training classifiers. Results: The training set consisted of 37 DJD ROIs with 475 non-DJD ROIs, and the testing set consisted of 32 DJD ROIs with 308 non-DJD ROIs. Of all classifiers, generalized linear models (GLM), decision forests (DF), and support vector machines (SVM) had the best performance. AUCs of GLM (0.929), DF (0.921), and SVM (0.889) were significantly higher than the other models (p<0.001). GLM and DF, overall, had the best sensitivity, specificity, and PPV, and gave a significantly better performance (p<0.01) than all other models. PET/CT GLM classifiers had higher AUC than just PET or just CT. GLMs built using PET/CT information had superior or comparable sensitivities, specificities and PPVs to just PET or just CT. Conclusion: Machine learning algorithms trained with PET/CT features were able to identify some cases of DJD. GLM outperformed the other classification algorithms. Using PET and CT information together was shown to be superior to using PET or CT features alone. Research supported by the Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Patterns of Response After Preoperative Intensity-Modulated Radiation Therapy and Capecitabine/Oxaliplatin in Rectal Cancer: Is There Still a Place for Ecoendoscopic Ultrasound?

Purpose: The main goals of preoperative chemoradiotherapy (CHRT) in rectal cancer are to achieve pathological response and to ensure tumor control with functional surgery when possible. Assessment of the concordance between clinical and pathological responses is necessary to make decisions regarding alternative conservative procedures. The present study evaluates the patterns of response after a preoperative CHRT regimen, and the value of endoscopic ultrasound (EUS) in assessing response. Methods and Materials: A total of 51 EUS-staged T3 to T4 and/or N0 to N+ rectal cancer patients received preoperative CHRT (intensity-modulated radiation therapy and capecitabine/oxaliplatin (XELOX) followed by radical resection. Clinical response was assesed by EUS. Rates of pathological tumor regression grade (TRG) and lymph node (LN) involvement were determined in the surgical specimen. Clinical and pathological responses were compared, and the accuracy of EUS in assessing response was calculated. Results: Twenty-four patients (45%) achieved a major pathological response (complete or >95% pathological response (TRG 3+/4)). Sensitivity, specificity, negative predictive value, and positive predictive value of EUS in predicting pathological T response after preoperative CHRT were 77.8%, 37.5%, 60%, and 58%, respectively. The EUS sensitivity, specificity, negative predictive value, and positive predictive value for nodal staging were 44%, 88%, 88%, and 44%, respectively. Furthermore, EUS after CHRT accurately predicted the absence of LN involvement in 7 of 7 patients (100%) with major pathological response of the primary tumor. Conclusion: Preoperative IMRT with concomitant XELOX induces favorable rates of major pathological response. EUS has a limited ability to predict primary tumor response after preoperative CHRT, but it is useful for accurately determining LN status. EUS may have a potential value in identifying patients with a very low risk of LN involvement in association with a good pathological response as potential candidates for conservative local surgical protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-EF-210-05: Diagnosis and Quantification of Liver Steatosis with Quantitative Ultrasound Backscatter Technique

Purpose: Nonalcoholic fatty liver disease (NAFLD) is the most common cause of chronic liver disease in the United States, affects 30% of adult Americans and may progress to more serious diseases. Liver biopsy is the standard method for diagnosing NAFLD. MRI can accurately diagnose and quantify hepatic steatosis but is expensive. Sonography with qualitative interpretation by radiologists is lower cost, more accessible but less sensitive for detection. The objective of this study, using MRI proton density fat fraction (PDFF) as reference, is to assess the accuracy for diagnosing and quantifying steatosis with two quantitative US parameters-- backscatter coefficient (BSC) and attenuation coefficient (AC)--derived from RF signals using the calibration phantom technique. Methods: We performed a prospective, cross-sectional analysis of a cohort of adults (n=204) with NAFLD (MRI-PDFF≥5%) and without NAFLD (controls). Subjects underwent MRI-PDFF and BSC and AC US analyses of the liver on the same day. Patients were randomly assigned to training (n=102, mean age 51±17 years, mean body mass index 31±7 kg/m{sup 2}) and validation (n=102, mean age 49±17 years, body mass index 30±6 kg/m{sup 2}) groups; 69% of patients in each group had NAFLD. Results: BSC provided AUC 0.98 (95% CI 0.95–1.00, p<0.0001) for diagnosis of NAFLD; the optimal BSC cut-off provided sensitivity, specificity, positive and negative predictive values (PPV, NPV) of 87%, 91%, 95%, and 76%, respectively. AC provided AUC 0.89 (95% CI 0.81–0.96, p<0.0001) for diagnosis of steatosis; the optimal AC cut-off provided sensitivity, specificity, PPV, NPV of 80%, 84%, 92%, and 66%, respectively. BSC and AC both correlated significantly with MRI-PDFF (P<0.0001). Conclusion: QUS BSC and AC can accurately diagnose and quantify hepatic steatosis, using MRI-PDFF as reference. With further validation, QUS may emerge as an inexpensive, widely available tool for NAFLD assessment. General support: NIH R01 CA111289, K23 -DK090303, AmerGastroAssoc Found, TF Williams Scholarship, S3000 scanner loaned by Siemens, Sucampo, JA Hartford Found, Atlantic Philanthropies Amer Gastroenterological Assoc. Agencies had no role in design/conduct of study, collection, management, analysis or interpretation of the data; preparation, review, or approval of the manuscript.

60 APPLIED LIFE SCIENCES↗

Can 18-FDG-PET During Radiotherapy Replace Post-Therapy Scanning for Detection/Demonstration of Tumor Response in Head-and-Neck Cancer?

Purpose: In routine practice, the tumor response in head-and-neck cancer (HNC) is assessed 3-4 months after radiotherapy (RT). We compared the results of fluorodeoxyglucose-positron emission tomography (FDG-PET) during (47 Gy) and 4 months after RT. Methods and Materials: In 40 patients with HNC, PET was performed before (PET1), at the end of Week 4 (47 Gy) (PET2), and 4 months after RT (PET3). Visual analysis classified patients as having a complete response (CR) or a non-CR (NCR). The sensitivity, specificity, accuracy, negative predictive value, and positive predictive value for PET2 and PET3 were determined. The 2-year overall survival (OS) rate for a CR and NCR was calculated for both response evaluation points. Results: After a median follow-up of 26 months, 10 patients had died, 6 had residual disease, and 24 remained disease free. The overall sensitivity, specificity, negative predictive value, positive predictive value, and accuracy of PET2 vs. PET3 for the detection of a CR was 28.6%, 81.8%, 31.0%, 80.0%, and 42.5% vs. 78.6%, 75.0%, 60.0%, 88.0%, and 77.5%, respectively. The 2-year OS rate determined at 47 Gy was 90.0% and 71.8% for a CR and NCR, respectively, and did not appear to be significantly different (p = .50). For the study, at 4 months, the OS was significantly better in the CR group (91.8%) than in the NCR group (49.9%; p = .0055). Conclusion: The high specificity and positive predictive value for the evaluation of tumor response with PET2 and PET3 might avoid unnecessary salvage surgery in patients with a CR. In contrast to PET3, the sensitivity of PET 2 was low, and the difference in OS between the CR and NCR groups was not significantly different. Therefore, the evaluation of the tumor response with FDG-PET at 4 months after RT completion cannot be replaced by FDG-PET during RT at 47 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Significance of Postradiotherapy [{sup 18}F]-Fluorodeoxyglucose Positron Emission Tomography Imaging in Management of Head-and-Neck Cancer-A Long-Term Outcome Report

Purpose: To determine the accuracy and prognostic significance of post-treatment [{sup 18}F]-fluorodeoxyglucose positron emission tomography (FDG-PET) in head-and-neck squamous cell carcinoma after radiotherapy (RT). Methods and Materials: This was a retrospective study of 188 patients with head-and-neck squamous cell carcinoma who had undergone FDG-PET within 12 months after completing RT. All living patients had {>=}1 year of follow-up after FDG-PET. All patients had undergone intensity-modulated RT, 128 with definitive and 60 with postoperative intensity-modulated RT. Results: For all patients, the median follow-up after RT completion was 32.6 months and after FDG-PET was 29.2 months. For the neck, 171 patients had negative FDG-PET findings. Of these results, two were falsely negative. Seventeen patients had positive FDG-PET findings, of which 12 were true-positive findings. The sensitivity, specificity, positive predictive value, and negative predictive value for FDG-PET in the assessment of the treatment response in the neck was 86%, 97%, 71%, and 99%, respectively. For the primary site, 151 patients had negative FDG-PET findings, of which two were falsely negative. Thirty-seven patients had positive FDG-PET findings, of which 12 were true-positive findings. The sensitivity, specificity, positive predictive value, and negative predictive value for FDG-PET in the assessment of the treatment response in the primary site was 86%, 86%, 32.4%, and 98.7%, respectively. Patients with positive post-RT PET findings had significantly worse 3-year overall survival and disease-free survival. Conclusion: The results of our study have shown that the findings of post-RT FDG-PET have a high negative predictive value and are a significant prognostic factor. It can provide guidance for the management of head-and-neck cancer after definitive treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulmonary Masses: Initial Results of Cone-beam CT Guidance with Needle Planning Software for Percutaneous Lung Biopsy

Purpose: To evaluate the outcome of percutaneous lung biopsy (PLB) findings using cone-beam computed tomographic (CT) guidance (CBCT guidance) and compared to conventional biopsy guidance techniques. Methods: CBCT guidance is a stereotactic technique for needle interventions, combining 3D soft-tissue cone-beam CT, needle planning software, and real-time fluoroscopy. Between March 2007 and August 2010, we performed 84 Tru-Cut PLBs, where bronchoscopy did not provide histopathologic diagnosis. Mean patient age was 64.6 (range 24-85) years; 57 patients were men, and 25 were women. Records were prospectively collected for calculating sensitivity, specificity, positive predictive value, negative predictive value, and accuracy. We also registered fluoroscopy time, room time, interventional time, dose-area product (DAP), and complications. Procedures were divided into subgroups (e.g., location, size, operator). Results: Mean lesion diameter was 32.5 (range 3.0-93.0) mm, and the mean number of samples per biopsy procedure was 3.2 (range 1-7). Mean fluoroscopy time was 161 (range 104-551) s, room time was 34 (range 15-79) min, mean DAP value was 25.9 (range 3.9-80.5) Gy{center_dot}cm{sup -2}, and interventional time was 18 (range 5-65) min. Of 84 lesions, 70 were malignant (83.3%) and 14 were benign (16.7%). Seven (8.3%) of the biopsy samples were nondiagnostic. All nondiagnostic biopsied lesions proved to be malignant during surgical resection. The outcome for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 90% (95% confidence interval [CI] 86-96), 100% (95% CI 82-100), 100% (95% CI 96-100), 66.7% (95% CI 55-83), and 91.7% (95% CI 86-96), respectively. Sixteen patients (19%) had minor and 2 (2.4%) had major complications. Conclusion: CBCT guidance is an effective method for PLB, with results comparable to CT/CT fluoroscopy guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗