Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensitivity Data File (SDF)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Hierarchical Data Format for Nuclear Data Sensitivities

The SCALE code system includes capabilities for sensitivity and uncertainty (S/U) analysis as part of its TSUNAMI code suite. The sensitivity of a quantity of interest (for example, an application’s $k_{eff}$) to nuclear data is stored as a profile in a text-based file, which is known as a sensitivity data file (SDF). The sensitivity profile can be used to calculate uncertainties, correlation coefficients, and similarity indices. One of the goals of the present work was to seek general performance improvements in the TSUNAMI code suite, starting with the TSUNAMI-IP code for calculating similarity indices. Through profiling, it was found that reading the text-based sensitivity files was a performance bottleneck in the TSUNAMI-IP code. In a typical TSUNAMI-IP calculation, an application might be compared to thousands of benchmarks, thus requiring the reading of thousands of SDFs. Reading of binary-based data is generally faster than reading text-based data. Hierarchical Data Format 5 (HDF5) is a binary-based format that also benefits from being portable, and it can be inspected with nonproprietary tools. This paper describes an HDF5-based file format that has been introduced for SDFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automated Direct Perturbation Calculations with SCALE TSUNAMI [Abstract]

In nuclear criticality safety analysis, the sensitivity of the eigenvalue keff to uncertainties in nuclear data and its evaluation are crucial. The TSUNAMI sequences within the SCALE code system offer users various options with both multigroup (MG) and continuous-energy (CE) 3D Monte Carlo (MC) transport capabilities for calculating keff sensitivity coefficients and storing them in a sensitivity data file (SDF). Each methodology available in TSUNAMI offers distinct advantages and limitations, and its effectiveness can vary based on the specific problem being solved. As a best practice, practitioners typically use the direct perturbation (DP) method as a confirmatory step alongside their sensitivity calculations to verify the accuracy of the sensitivity data generated. In this process, DP calculations are usually performed on select nuclides, those considered most important for validating their total sensitivities. However, because of code limitations, analysts use a workaround method when conducting DP calculations for a single nuclide: rather than perturbing the nuclide's microscopic cross section, an equivalent number density for this nuclide is calculated to reflect the effect of a change in the macroscopic cross section due to a perturbation in the microscopic cross section. The current approach requires rerunning the CSAS criticality calculation several times with model changes. Although this method can yield results with acceptable accuracy, it is labor-intensive and prone to errors.

AZURE: SAMMY↗

Validating Mixtures of 233 U, 235 U, and 239 Pu for the Sum-of-Fractions Method

The Sum-of-Fractions method is a technique used to assure that homogeneous mixtures of fissile and fissionable isotopes are below a minimum margin of k eff or reactivity. Current work by Pacific Northwest National Laboratory examines different mixtures of 233 U, 235 U, and 239 Pu to determine critical mass limits for mixtures of transuranic actinides lacking a validation basis. To provide a validation basis for these limits, the work presented here describes the results of a sensitivity and uncertainty analysis of various mixtures of these isotopes in various concentrations moderated and reflected by light water and polyethylene. The TSUNAMI-1D sequence in the SCALE code system was used to generate sensitivity coefficients for three different concentrations of mixtures of 233 U, 235 U, and 239 Pu. The TSUNAMI-IP sequence was then used for similarity assessment (c k ) with critical benchmark experiment sensitivity data files (SDFs) from the Oak Ridge National Laboratory Verified, Archived Library of Inputs and Data and the Nuclear Energy Agency SDF database. The VADER sequence in SCALE was used for statistical testing and to generate upper subcritical limits from the data to develop a basis for validating critical mass limits.

07 ISOTOPE AND RADIATION SOURCES↗

PYDICE

A new Python program has been created that calculates similarity metrics (E, ck), available as a web server. Users can post one or more Sensitivity Data Files (SDFs) to either calculate similarity metrics (returned as a JSON response packet) or to be converted into a different SDF format (returned as a zip file).

Holcomb, Andrew [Oak Ridge National Laboratory (OR↗

Verified, Archived, Library of Inputs and Data (VALID) Supporting Files

This dataset contains input, output, and sensitivity data files for computational simulations with the SCALE code system as part of the Verified, Archived Library of Inputs and Data (VALID). The simulations cover critical benchmark experiments from the International Criticality Safety Benchmark Evaluation Project. The files are to be housed in a public directory for distribution. The information contained in the files have been approved for release by the Organisation for Economic Co-operation and Development Nuclear Energy Agency (NEA). Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases.

keff↗