Resolution of semiconductor detectors for fission fragments.
Energy resolution of semiconductor detectors for fission fragments
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Energy resolution of semiconductor detectors for fission fragments
Nuclear semiconductor detector for charged- particle space spectrometry
Nuclear biomedicine semiconductor detectors for radioisotope detection in in-vivo and uptake studies
Adding a new semiconductor detector into the detector response function toolkit (DRiFT) requires a model of the electric potential and the electric field. To get an accurate electrostatics model, the geometry of the detector should be modeled as closely to the real geometry as feasible, including the semiconductor materials, doping layers and concentrations, and contacts. Since the electric field and potential are used to calculate the induced signal, the results of the detector response functions are largely influenced by the electrostatics models. Initial electrostatics models were completed using Silvaco, however, this document provides guidance on using COMSOL Mulitphysics ® (COMSOL) to model the detectors to give users additional flexibility. Guidance on using COMSOL and its user interface are mostly left out of this document, but best practices for geometry, modeling methods, and data format/exporting are included to help users generate models that are compatible with DRiFT, prevents bugs, issues, and inaccuracies during charge collection calculations. The following summary provides an overview of the document.
Medical and biological semiconductor detectors for manned space flight missions
Abstract Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr 3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 10 10 photons s −1 mm −2 is reported. High‐quality solution‐grown CsPbBr 3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr 3 /Au. A high reverse‐bias voltage of 1000 V (435 V mm − 1 ) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm − 2 ), which enables a high sensitivity larger than 10 000 µC Gy air −1 cm − 2 and a simultaneous low detection limit of 22 nGy air s − 1 . The CsPbBr 3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 10 6 to 10 10 photons s − 1 mm − 2 . Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr 3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr 3 .
Energy for electron-hole pair generation in silicon by protons using lithium drifted semiconductor detectors
Fluctuations and broadening of energy-loss spectrum of charged particles passing through semiconductor detectors
Atomic scattering contribution to pulse height defect and energy dispersion of heavy ions in semiconductor detectors
Electron irradiation effect on resolution of lithium-drifted silicon semiconductor detectors
Lithium drifted silicon semiconductor radiation detectors, proton absorption in metal, plastics, and tissue, and detector behavior
Semiconductor detector-dosimeter characteristics and application to problems of whole body dosimetry - Monte Carlo proton transport program
Preparation of lithium-drifted semiconductor nuclear particle detectors
Cadmium Zinc Telluride Selenide (CdZnTeSe or CZTS)has shown high crystal quality for room-temperature gamma ray and X-ray detection applications compared to Cadmium Zinc Telluride (CdZnTe or CZT) [1,2]. Current applications of CZT include medical imaging, homeland security, and X-ray and gamma ray astronomy [3]. CZST has similar potential applications
Lithium drifted germanium and silicon semiconducting detectors compared with thallium activated sodium iodide crystal scintillation counter for gamma spectrometry
Theory, characteristics, and fabrication of lithium-drifted silicon detectors
Penetration and proton interaction with matter, including stopping power measurements and mean ionization potential values
Nuclear radiation detectors with volumes of approximately 1 cu cm was fabricated from single crystals of germanium-silicon alloy containing as much as 20 weight percent germanium. The properties of these detectors were investigated and will be discussed. Tests reveal that the gamma ray photoelectric peak efficiency of an alloy detector with only 12 weight percent germanium is approximately 4 times that of a silicon detector of equal volume. The room temperature roomure appears to be a good possibility. Storage for long periods at room temperature does not seem to adversely affect these devices. The results of preliminary radiation damage experiments suggest that the alloy detectors possess a radiation damage resistance far greater than that of silicon.