Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYSTEM STABILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

ML-Based Power System Stability Assessment Considering Network Topology Changes: WECC 20,000+ Bus System Case Study

Modern power grids are fast-changing and thus require real-time monitoring and online stability assessment. With the rapid development of machine learning (ML) techniques, using data-driven models to provide fast and accurate estimations of power system stability marginal information, such as frequency nadir for frequency stability and critical clearing time (CCT) for transient stability, have become possible. However, despite the numerous research on ML-based methods for frequency nadir and CCT prediction, there is limited work on the impact of different network topology changes. Furthermore, most previous studies only focused on small or synthetic systems, and there is a lack of research on actual large power system models. In this paper, the above issues are addressed by studying the actual U.S. Western Electricity Coordinating Council (WECC) system model with more than 20,000 buses. Massive simulations are conducted in PowerWorld Simulator to study the impact of various topology change scenarios on both frequency stability and transient stability. System operating information is extracted from the success dispatch cases of various network topologies to generate a comprehensive dataset for ML-based models. Two ML methods, random forest (RF) and multilayer perceptron (MLP) neural network, are trained and tested for both frequency nadir prediction and CCT prediction. Test results have proven the models are capable of online stability assessment for large power networks such as the WECC system with sufficient accuracy.

critical clearing time↗

Disintegration and Biodegradation in Soil of PBAT Mulch Films: Influence of the Stabilization Systems Based on Carbon Black/Hindered Amine Light Stabilizer and Carbon Black/Vitamin E

This work characterized the disintegration and biodegradation of aged samples of PBAT films with and without photostabilization additives. The objective is to correlate these processes with properties affected after aging, i.e. molecular weight and gel content. Three different formulations were studied: pure polymer; PBAT with carbon black and hindered amine light stabilizer (HALS) and PBAT with carbon black and phenolic stabilizer vitamin E. The samples were monitored for 12 months. As expected, the lower level of photostabilization lead to the higher disintegration and biodegradation rates. Nevertheless, mineralization test showed that during time the differences among biodegradation rates become subtler. The crystallinity degree presented changes only at an advanced stage of degradation process, showing a reduction. The evaluation of the carbonyl index, molecular weight, surface morphology and visual analysis allowed to observe that the aged samples with lower gel content and lower molecular weight showed a faster degradation rate. The changes in material structure due to the increase of aromatic units concentration is the main hypothesis to explain the material behavior during degradation in soil.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust Power System Stability Assessment Against Adversarial Machine Learning-Based Cyberattacks via Online Purification

The increasing complexity associated with renewable generation brings more challenges to power system stability assessment (SA). Data-driven approaches based on machine learning (ML) techniques for stability assessment have received significant research interest and shown their promising performance. However, ML-based models are recognized to be vulnerable to adversarial disturbances, where a slight perturbation to power system measurements could lead to unacceptable errors. To address this issue, this paper develops a novel lightweight mitigation strategy, i.e., robust online stability assessment (ROSA), to enhance the ML-based assessment model against both white-box and the black-box adversarial disturbances (i.e., purification) in the online implementation. The ROSA involves a supervised learning-based module for the primary stability assessment and a self-supervised learning-based module. Further, the two modules are trained jointly with different objective (loss) functions and implemented in sequence. A suitable purification objective and various time-series data augmentation methods are designed for SA applications to tackle adversarial disturbances adaptively. Case studies are performed, and the comparative results have clearly illustrated the competitive, robust accuracy against various adversarial scenarios and verified the effectiveness of the proposed online purification strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementing a Laser Stabilization System for Trapping Ca+ Ions: an Internship Reflection

At Lawrence Livermore National Laboratory, I contributed to a project developing 3D printed micro ion traps for quantum computing. I designed, implemented, and assessed a laser stabilization system that locked lasers to the frequencies required for calibrating our High Finesse WS8-10 wavelength meter and for laser cooling and trapping of Ca+ ions. I also programmed a Python interface for hardware communication, data collection, and statistical analysis. Additionally, I optimized and aligned laser beam paths, and I implemented a closed digital feedback loop using Proportional, Integral, and Derivative (PID) control parameters. I analyzed both the long-term and short-term behavior of our locked lasers and adjusted PID parameters to enhance performance. Furthermore, I used COMSOL to simulate the capacitance of a linear Paul trap design and predict our trap’s performance. The procedures I developed for the interface, analysis, and simulations will continue to support the ion trapping experiment after my appointment. I strengthened my skills in data analysis, Python coding, and optical alignment for laser systems. My confidence as a researcher grew, particularly in communicating my research. This experience taught me the importance of careful planning and consideration in research and solidified my desire to continue exploring novel quantum technology as an undergraduate

42 ENGINEERING↗

Impact analysis of DERs on bulk power system stability through the parameterization of aggregated DER_a model for real feeders

With an ever increasing percentage of distributed energy resources (DERs) connected behind the meter in the distribution system, it is becoming increasingly important to equip transmission planners with the visibility of DER dynamic performance in distribution system. Not having visibility of the disconnection of DERs with the occurrence of transmission events, could result in an erroneous view of the stability of bulk power system. Here, in this paper, a parameterized aggregated model (DER_a) serves as a representation of the distribution-level dynamics of real residential feeders, which is used for analysis of bulk power system stability. The parameters are obtained by executing dynamic Monte Carlo simulations. Faults are then induced at the substation level causing the DERs to trip which subsequently enables the parameterization of the low and high voltage breakpoints (v l0 , v l1 , v h0 , and v h1 ) of the DER_a model’s partial voltage trip block. These parameters are then utilized to study the effectiveness of the DER_a model to represent the behavior of the aggregated DERs’ response and their impact on the bulk power system. The case study shows the ability of the positive-sequence DER_a model to provide an accurate estimation of DERs that are susceptible to trip due to 3-$\phi$ and 1-$\phi$ faults of transmission.

14 SOLAR ENERGY↗

Co-Simulation of PSS/E, OpenDSS, and PSCAD for Power Systems Stability Analysis With Inverter-Based Resources: Preprint

The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Active Damping With Energy Storage to Improve Power System Frequency Stability

As renewable resources displace traditional generation, there may be times when there is relatively less rotational inertia (H, MW-s) to stabilize power system frequency following a power system disturbance. This article outlines a method for the control of Battery Energy Storage System (BESS) to mitigate power system frequency disturbances. The control scheme discussed in the article leverages latest ‘smart grid’ technologies including PMU’s and advanced grid-supportive inverters. The authors’ screening-level analysis of this novel BESS control concept indicates the potential to increase the speed of recovery of disturbed power systems, i.e. return power system frequency to nominal value (60 Hz in N. America), following a system disturbance. Increasing power system stability by adding inertial-support from appropriately controlled BESS will help power systems accommodate more renewable generation before hitting stability limits.

Energy Storage↗

Region-Based Stability Analysis of Resilient Distribution Systems with Hybrid Grid-Forming and Grid-Following Inverters

In this paper, distribution system stability considering mixed grid-forming (GFM) and grid-following (GFL) inverters is discussed. A holistic small-signal model of the distribution feeder accommodating both GFM and GFL inverters is derived. In contrast to conventional point-by-point stability analysis, a region-based stability assessment approach is proposed and implemented to evaluate small-signal system stability with both GFM and GFL controls. Furthermore, to enhance the computational efficiency, an Artificial Intelligence (AI) assisted Kernel Ridge Regression (KRR) approach is developed to obtain the stability region boundary. Therefore, with the derived stability region, the impact of critical parameters on system stability is intuitively shown, and more importantly, the relationship between the maximum penetration level and the corresponding feasible range of the selected control parameters can be quantified. The proposed approach has been validated using MATLAB/Simulink.

grid-following↗

Using a Grid-Forming Inverter to Stabilize a Low-Inertia Power System - Maui Hawaiian Island

As power systems around the world integrate greater amounts of wind and solar photovoltaic power, periods of very high instantaneous power shares of inverters, the primary interfacing technology for these generation sources, are complicating system stability and control. The contemporary, primary mode of inverter operation, grid-following, which explicitly assumes the presence of a local, stable voltage waveform, yields operational inadequacy at high instantaneous power shares potentially leading to instability due to the low-inertia conditions, as well as the correlated reduced voltage forming capacity on the respective system. Parallel connected grid-forming inverters, which directly regulate the local voltage, are a solution that is expected to bolster system stability and mitigate the shortcomings of the grid-following technology. In this paper, grid-following and two types of grid-forming inverter control, the traditional linear droop and the recently introduced nonlinear exponential droop (Droop-e), are simulated on a low-inertia, H = 0.48s, high inverter-based resource scenario, 97%, with a validated electromagentic transient domain model of the Hawaiian island of Maui power system. The benefit of a single grid-forming device over its grid-following counterpart is significant, both in terms frequency deviation and voltage stability. Further, the superiority of the Droop-e and the associated secondary power sharing control over both grid-following and linear droop grid-forming technologies is displayed, with improved nadir and rate of change of frequency over the linear droop control.

droop control↗

Analyzing Impact of Distributed PV Generation on Integrated Transmission & Distribution System Voltage Stability—A Graph Trace Analysis Based Approach

The use of a Graph Trace Analysis (GTA)-based power flow for analyzing the voltage stability of integrated Transmission and Distribution (T&D) networks is discussed in the context of distributed Photovoltaic (PV) generation. The voltage stability of lines and the load carrying capability of buses is analyzed at various PV penetration levels. It is shown that as the PV generation levels increase, an increase in the steady state voltage stability of the system is observed. Moreover, within certain regions of stability margin changes, changes in voltage stability margins of transmission lines are shown to be linearly related to changes in the loading of the lines. Two case studies are presented, where one case study involves a model with eight voltage levels and 784,000 nodes. In one case study, a voltage-stability heat map is used to demonstrate the identification of weak lines and buses.

14 SOLAR ENERGY↗