Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYNCHROTRON RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Spherical quartz crystals investigated with synchrotron radiation

The quality of x-ray spectra and images obtained from plasmas with spherically bent crystals depends in part on the crystal's x-ray diffraction across the entire crystal surface. We employ the energy selectivity and high intensity of synchrotron radiation to examine typical spherical crystals from alpha-quartz for their diffraction quality, in a perpendicular geometry that is particularly convenient to examine sagittal focusing. The crystal's local diffraction is not ideal: the most noticeable problems come from isolated regions that so far have failed to correlate with visible imperfections. In conclusion, excluding diffraction from such problem spots has little effect on the focus beyond a decrease in background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE RADIATIVE TRANSFER OF SYNCHROTRON RADIATION THROUGH A COMPRESSED RANDOM MAGNETIC FIELD

This paper examines the radiative transfer of synchrotron radiation in the presence of a magnetic field configuration resulting from the compression of a highly disordered magnetic field. It is shown that, provided Faraday rotation and circular polarization can be neglected, the radiative transfer equations for synchrotron radiation separate for this configuration, and the intensities and polarization values for sources that are uniform on large scales can be found straightforwardly in the case where opacity is significant. Although the emission and absorption coefficients must, in general, be obtained numerically, the process is much simpler than a full numerical solution to the transfer equations. Some illustrative results are given and an interesting effect, whereby the polarization increases while the magnetic field distribution becomes less strongly confined to the plane of compression, is discussed. The results are of importance for the interpretation of polarization near the edges of lobes in radio galaxies and of bright features in the parsec-scale jets of active galactic nuclei, where such magnetic field configurations are believed to exist.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmic rays, gamma rays and synchrotron radiation from the Galaxy

Galactic cosmic rays (CR), interstellar gamma-ray emission and synchrotron radiation are related topics. CR electrons propagate in the Galaxy and interact with the interstellar medium, producing inverse-Compton emission measured in gamma rays and synchrotron emission measured in radio. I present an overview of the latest results with Fermi/LAT on the gamma-ray diffuse emission induced by CR nuclei and electrons. Then I focus on the recent complementary studies of the synchrotron emission in the light of the latest gamma-ray results. Relevant observables include spectral indices and their variations, using surveys over a wide range of radio frequencies. This paper enphasizes the importance of using the parallel study of gamma rays and synchrotron radiation in order to constrain the low-energy interstellar CR electron spectrum, models of propagation of CRs, and magnetic fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculations of synchrotron radiation emission in the transverse coherent limit

We present approximations for the synchrotron radiation emission for low emittance light sources, which provide a connection between user needs and the electron beam parameters. The results and calculations are a consequence of the phase coherence in the emission from the electrons. We derive the remarkable result that if the electron beam is energetic enough, the emitted flux is independent of the photon energy, electron beam energy, or bending radius in the transverse coherent limit. Similarly the brightness is identical for all machines at a given current.

43 PARTICLE ACCELERATORS↗

Analysis of rapidly synthesized guest-filled porous complexes with synchrotron radiation: practical guidelines for the crystalline sponge method

This report describes complete practical guidelines and insights for the crystalline sponge method, which have been derived through the first use of synchrotron radiation on these systems, and includes a procedure for faster synthesis of the sponges. These guidelines will be applicable to crystal sponge data collected at synchrotrons or in-house facilities, and will allow researchers to obtain reliable high-quality data and construct chemically and physically sensible models for guest structural determination. A detailed set of synthetic and crystallographic guidelines for the crystalline sponge method based upon the analysis of expediently synthesized crystal sponges using third-generation synchrotron radiation are reported. The procedure for the synthesis of the zinc-based metal–organic framework used in initial crystal sponge reports has been modified to yield competent crystals in 3 days instead of 2 weeks. These crystal sponges were tested on some small molecules, with two being unexpectedly difficult cases for analysis with in-house diffractometers in regard to data quality and proper space-group determination. These issues were easily resolved by the use of synchrotron radiation using data-collection times of less than an hour. One of these guests induced a single-crystal-to-single-crystal transformation to create a larger unit cell with over 500 non-H atoms in the asymmetric unit. This led to a non-trivial refinement scenario that afforded the best Flack x absolute stereochemical determination parameter to date for these systems. The structures did not require the use of PLATON/SQUEEZE or other solvent-masking programs, and are the highest-quality crystalline sponge systems reported to date where the results are strongly supported by the data. A set of guidelines for the entire crystallographic process were developed through these studies. In particular, the refinement guidelines include strategies to refine the host framework, locate guests and determine occupancies, discussion of the proper use of geometric and anisotropic displacement parameter restraints and constraints, and whether to perform solvent squeezing/masking. The single-crystal-to-single-crystal transformation process for the crystal sponges is also discussed. The presented general guidelines will be invaluable for researchers interested in using the crystalline sponge method at in-house diffraction or synchrotron facilities, will facilitate the collection and analysis of reliable high-quality data, and will allow construction of chemically and physically sensible models for guest structural determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Current advances in synchrotron radiation instrumentation for MX experiments

Following pioneering work 40 years ago, synchrotron beamlines dedicated to macromolecular crystallography (MX) have improved in almost every aspect as instrumentation has evolved. Beam sizes and crystal dimensions are now on the single micron scale while data can be collected from proteins with molecular weights over 10 MDa and from crystals with unit cell dimensions over 1000 Å. Furthermore it is possible to collect a complete data set in seconds, and obtain the resulting structure in minutes. The impact of MX synchrotron beamlines and their evolution is reflected in their scientific output, and MX is now the method of choice for a variety of aims from ligand binding to structure determination of membrane proteins, viruses and ribosomes, resulting in a much deeper understanding of the machinery of life. A main driving force of beamline evolution have been advances in almost every aspect of the instrumentation comprising a synchrotron beamline. In this review we aim to provide an overview of the current status of instrumentation at modern MX experiments. The most critical optical components are discussed, as are aspects of endstation design, sample delivery, visualisation and positioning, the sample environment, beam shaping, detectors and data acquisition and processing.

59 BASIC BIOLOGICAL SCIENCES↗

Radiometry and metrology of a phase zone plate measured by extreme ultraviolet synchrotron radiation

The diffraction efficiency, focal length, and other radiometric and metrology properties of a phase zone plate were measured by using monochromatic synchrotron radiation in the 7-18.5 nm wavelength range. The zone plate was composed of molybdenum zones having a 4 mm outer diameter and 70 nm nominal thickness and supported on a 100 nm thick silicon nitride membrane. The diffraction efficiency was enhanced by the phase shift of the radiation passing through the zones. The measured first-order efficiency was in good agreement with the calculated efficiency. The properties of the zone plate, particularly the small variation of the efficiency with off-axis angle, make it suitable for use in a radiometer to accurately measure the absolutely calibrated extreme ultraviolet emission from the Sun.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of breast imaging using synchrotron radiation

Purpose: Synchrotron radiation (SR), being the brightest artificial source of x-rays with a very promising geometry, has raised the scientific expectations that it could be used for breast imaging with optimized results. The ''in situ'' evaluation of this technique is difficult to perform, mostly due to the limited available SR facilities worldwide. In this study, a simulation model for SR breast imaging was developed, based on Monte Carlo simulation techniques, and validated using data acquired in the SYRMEP beamline of the Elettra facility in Trieste, Italy. Furthermore, primary results concerning the performance of SR were derived. Methods: The developed model includes the exact setup of the SR beamline, considering that the x-ray source is located at almost 23 m from the slit, while the photon energy was considered to originate from a very narrow Gaussian spectrum. Breast phantoms, made of Perspex and filled with air cavities, were irradiated with energies in the range of 16-28 keV. The model included a Gd{sub 2}O{sub 2}S detector with the same characteristics as the one available in the SYRMEP beamline. Following the development and validation of the model, experiments were performed in order to evaluate the contrast resolution of SR. A phantom made of adipose tissue and filled with inhomogeneities of several compositions and sizes was designed and utilized to simulate the irradiation under conventional mammography and SR conditions. Results: The validation results of the model showed an excellent agreement with the experimental data, with the correlation for contrast being 0.996. Significant differences only appeared at the edges of the phantom, where phase effects occur. The initial evaluation experiments revealed that SR shows very good performance in terms of the image quality indices utilized, namely subject contrast and contrast to noise ratio. The response of subject contrast to energy is monotonic; however, this does not stand for contrast to noise ratio, since there is a range of optimal performance for SR (18-21 keV). In comparison to conventional mammography, SR shows improved subject contrast for energies lower than the mean energy of each spectrum. Conclusions: The comparison of the results of the two models, conventional and SR, proved that SR exhibits better performance in the majority of cases. The proposed simulation model offers the possibility to perform exhaustive search to evaluate the performance of SR in clinical applications such as breast imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Zone Plate Properties using Monochromatic Synchrotron Radiation in the 2 to 20 nm Wavelength Range

A zone plate composed of Mo zones having 4 mm outermost zone diameter, 100 nm outermost zone width, and supported on a silicon nitride membrane was characterized using monochromatic synchrotron radiation in the 2 to 20 nm wavelength range. The zero and first order efficiencies were measured and compared to ab initio calculations that account for the optical properties of the materials, the width and shape of the zones, and multiple-layer thin-film effects. It is shown that the thicknesses of the Mo zones and the membrane and the ratio of the zone width to zone period can be independently determined from the measured diffraction efficiencies in the zero and first orders and that the computational code can be used to reliably design zone plates that are optimized for applications such as solar irradiance monitors in the extreme ultraviolet region.

36 MATERIALS SCIENCE↗

Structural basis for supercooled liquid fragility established by synchrotron-radiation method and computer simulation

Metallic melts above the liquidus temperature exhibit nearly Arrhenius-type temperature dependence of viscosity. On cooling below the equilibrium liquidus temperature metallic melts exhibit a non-Arrhenius temperature dependence of viscosity characterized by liquid fragility phenomenon which origin is still not well understood. Structural changes and vitrification of the Pd{sub 42.5}Cu{sub 30}Ni{sub 7.5}P{sub 20} liquid alloy on cooling from above the equilibrium liquidus temperature are studied by synchrotron radiation X-ray diffraction and compared with the results of first-principles calculations. Subsequent analysis of the atomic and electronic structure of the alloy in liquid and glassy states reveals formation of chemical short-range order in the temperature range corresponding to such a non-Arrhenius behavior. The first-principles calculations were applied to confirm the experimental findings.

36 MATERIALS SCIENCE↗

Perfect crystal propagator for physical optics simulations with Synchrotron Radiation Workshop

Until now, a treatment of dynamical diffraction from perfect crystals has been missing in the "Synchrotron Radiation Workshop" (SRW) wavefront propagation computer code despite the widespread use of crystals on X-ray synchrotron beamlines. Now a special propagator" module for calculating dynamical diffraction from a perfect crystal in the Bragg case has been written in C++, integrated into the SRW C/C++ library and made available for simulations using the Python interface of SRW. The propagator performs local processing of the frequency-domain electric field in the angular representation. A 2-D Fast Fourier Transform is used for changing the field representation from/to the coordinate representation before and after applying the crystal propagator. This ensures seamless integration of the new propagator with the existing functionalities of the SRW package, allows compatibility with existing propagators for other optical elements, and enables the simulation of complex beamlines transporting partially coherent X-rays. The code has been benchmarked by comparison with predictions made by plane-wave and spherical-wave dynamical diffraction theory. Test simulations for a selection of X-ray synchrotron beamlines are also shown.

47 OTHER INSTRUMENTATION↗

Ultrafast, high resolution, phase contrast imaging of impact response with synchrotron radiation

Understanding the dynamic response of materials at extreme conditions requires diagnostics that can provide real-time, in situ, spatially resolved measurements on the nanosecond timescale. The development of methods such as phase contrast imaging (PCI) typically used at synchrotron sources offer unique opportunities to examine dynamic material response. In this work, we report ultrafast, high-resolution, dynamic PCI measurements of shock compressed materials with 3 {mu}m spatial resolution using a single 60 ps synchrotron X-ray bunch. These results firmly establish the use of PCI to examine dynamic phenomena at ns to {mu}s timescales.

36 MATERIALS SCIENCE↗