SWP Summary Report for Individual Legacy Well Leakage Risk Analysis at Farnsworth Unit Site: Open Well Scenario

This report summarizes results of the individual legacy well leakage risk analysis of the Farnsworth Unit site (FWU) for Open Well scenario. NRAP tools Integrated Assessment Model for Carbon Storage (NRAP-IAM-CS) and Reservoir Reduced-Order Model Generator (RROMGen) were used (Dilmore et al., 2016; Pawar et al., 2016; King, 2016). This is part one of the additional analysis addressing SWP BP4 Subtask 7.4.1.2: Extend quantitative brine and CO2 leakage calculations (Chu et al., 2020).

58 GEOSCIENCES↗

Southwest Regional Partnership on Carbon Sequestration: Phase III (Final Scientific/Technical Report)

The Southwest Regional Partnership on Carbon Sequestration (SWP) is one of 7 regional partnerships formed in 2003 under the U.S. Department of Energy’s (DOE) Regional Carbon Sequestration Partnerships (RCSPs) initiative. The overall purpose of the initiative was to help determine and implement the technology, infrastructure, and regulations most appropriate to promote carbon storage in different regions of the country. Covering Arizona, Colorado, New Mexico, Oklahoma, Utah, and parts of Texas, Wyoming, and Kansas, the SWP evaluated regional carbon storage and utilization potential and focused on technologies and sites that could complement the region’s strong position in energy production. The project progressed through three phases: • Phase I (2003–2005): Characterized regional geologic formations and CO 2 sources, assessed sequestration potential, and identified pilot test sites. • Phase II (2005–2013): Conducted small-scale field tests to validate sequestration methods, including geologic and terrestrial projects. • Phase III (2008–2022): Demonstrated large-scale CO 2 injection at a commercial oil field to test monitoring, verification, and long-term storage strategies. This report covers Phase III. The final project site, the Farnsworth Unit (FWU) in Texas, provided real-world testing of reservoir characterization, monitoring, and risk evaluation tools and processes that could be used in any commercial scale carbon capture, utilization, and storage (CCUS) project. Extensive data collection and analysis helped refine best practices for reservoir characterization, injection monitoring, and storage verification. The SWP contributed to national databases, DOE best practice manuals, and regional geological assessments to support future sequestration efforts. Key lessons learned include the importance of robust data management, strategic site selection, regulatory navigation, and effective industry collaboration. The project’s findings will inform ongoing and future carbon storage initiatives. Task 1 (Regional Characterization) • The SWP continued to participate in national outreach efforts and NATCARB. • The SWP evaluated multiple potential sites before selecting the FWU as the primary field test location. Task 2 (Public Outreach and Education) • The SWP contributed to national databases, DOE best practice manuals, and regional geological assessments to support future sequestration efforts. Task 3 (Permitting and Regulatory Compliance) • The SWP ensured compliance with federal and state regulations, including National Environmental Policy Act (NEPA) requirements. • The SWP obtained all necessary permits for drilling, injection, and monitoring activities. Task 4 (Site Characterization and Planning) • The SWP developed work plans for four key activities: characterization, simulation, monitoring and verification, and risk evaluation. • The SWP collected and synthesized legacy data from multiple sources to build initial static geological models and dynamic reservoir models demonstrating project feasibility. • The SWP conducted an initial risk evaluation and developed mitigation plans. Task 5 (Field Operations and Data Collection) • The SWP drilled, logged, and cored three characterization wells to gather critical subsurface data. • The SWP conducted multiple geophysical surveys, including 3D seismic, crosswell seismic, and vertical seismic profiling, to improve reservoir characterization. Task 6 (Monitoring and Verification) • The SWP performed extensive geological characterization using data from characterization wells and seismic surveys. • The SWP established a surface monitoring network to track CO 2 flux in soil gas, groundwater chemistry, and near-surface atmospheric CO 2 levels. • The SWP built and refined reservoir models to study the effects of relative permeability on simulation behavior and improve calibration with experimental data. Task 7 (Risk Assessment and Model Refinement) • The SWP conducted multiple studies to evaluate reservoir integrity, predict CO 2 plume behavior and improve predictive modeling capabilities. • The SWP refined geological models and used them to enhance the accuracy of simulation models. • The SWP continued quantitative risk assessment of top-ranked risks and strengthened the link between qualitative and quantitative risk methodologies.

02 PETROLEUM↗

Particle-in-cell/Monte Carlo collision simulation of the ionization process of surface-wave plasma discharges resonantly excited by surface plasmon polaritons

Although surface-wave plasma (SWP) sources have many industrial applications, the ionization process for SWP discharges is not yet well understood. The resonant excitation of surface plasmon polaritons (SPPs) has recently been proposed to produce SWP efficiently, and this work presents a numerical study of the mechanism to produce SWP sources. Specifically, SWP resonantly excited by SPPs at low pressure (0.25 Torr) are modeled using a two-dimensional in the working space and three-dimensional in the velocity space particle-in-cell with the Monte Carlo collision method. Simulation results are sampled at different time steps, in which the detailed information about the distribution of electrons and electromagnetic fields is obtained. Results show that the mode conversion between surface waves of SPPs and electron plasma waves (EPWs) occurs efficiently at the location where the plasma density is higher than 3.57 Multiplication-Sign 10{sup 17} m{sup -3}. Due to the effect of the locally enhanced electric field of SPPs, the mode conversion between the surface waves of SPPs and EPWs is very strong, which plays a significant role in efficiently heating SWP to the overdense state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Core Analysis E-Reports Produced for the Southwest Regional Partnership on Carbon Sequestration for Wells 13-10A, 13-14, and 32-8 of the Farnsworth Unit, Texas

The submission is three electronic reports (e-reports) produced by Terra Tek, a former Schlumberger company, for and under the oversight of the Southwest Regional Partnership on Carbon Sequestration (SWP). The SWP designed and implemented a coring and core analysis program in conjunction with the previous field operator Chaparral Energy, L.L.C. The main SWP contacts who oversaw the coring and core analysis program, including geologic core descriptions and sample selection for testing by the Terra Tek, are listed below in the Authors section. The three reports are for Wells 13-10A, 13-14, and 32-8 of the Farnsworth Unit, TX, a site of the SWP's CO2 storage and enhanced oil recovery project. The e-reports include many data types that are not listed in full detail here, but may include: geomechanical, geochemical, and petrophysical measurements; white light and UV core photos; spectral gamma logs on the core; and Heterogeneous Rock Analysis logs. Fracture core review reports are included for Wells 13-14 and 32-8. The three e-reports each have many subfolders with the various types of data in spreadsheets, pdfs, image files, or other formats. The main e-reports for each well are listed by the well name. The sub-folder “E-Report” for each well has a Report.html file, which, when opened, will have hyperlinks to the various data sets and information. The files in the zipped folder will need to be extracted for the Report.html files to work properly. These authors thank Joseph Hall, a geologist formerly of Chaparral Energy, L.L.C., for assistance in designing the coring program, his geologic expertise of the Farnsworth Unit, and his assistance with characterizing the core. Christopher Gillespie, of Terra Tek at the time, managed the myriad geomechanical, geochemical, and petrophysical measurements provided by Terra Tek for this project. The core from which the samples were collected for this project are housed at the Subsurface Data and Core Libraries of the New Mexico Bureau of Geology and Mineral Resources, Socorro, New Mexico, USA. Funding for this project is provided by the U.S. Department of Energy's (DOE) National Energy Technology Laboratory (NETL) through the Southwest Regional Partnership on Carbon Sequestration (SWP) under Award No. DE-FC26-05NT42591. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. These e-reports describe objective technical results and analysis. Any subjective views or opinions that might be expressed in the reports do not necessarily represent the views of the US Department of Energy or the United States Government.

Caprock↗

Risk Assessment and Management Workflow—An Example of the Southwest Regional Partnership

This paper summarizes the risk assessment and management workflow developed and applied to the Southwest Regional Partnership on Carbon Sequestration (SWP) Phase III Demonstration Project. The risk assessment and management workflow consists of six primary tasks, including management planning, identification, qualitative analysis, quantitative analysis, response planning, and monitoring. Within the workflow, the SWP assembled and iteratively updated a risk registry that identifies risks for all major activities of the project. Risk elements were ranked with respect to the potential impact to the project and the likelihood of occurrence. Both qualitative and quantitative risk analyses were performed. To graphically depict the interactions among risk elements and help building risk scenarios, process influence diagrams were used to represent the interactions. The SWP employed quantitative methods of risk analysis including Response Surface Method (RSM), Polynomial Chaos Expansion (PCE), and the National Risk Assessment Partnership (NRAP) toolset. The SWP also developed risk response planning and performed risk control and monitoring to prevent the risks from affecting the project and ensure the effectiveness of risk management. As part of risk control and monitoring, existing and new risks have been tracked and the response plan was subsequently evaluated. Findings and lessons learned from the SWP’s risk assessment and management efforts will provide valuable information for other commercial geological CO2 storage projects.

Lee, Si-Yong↗

Study of a linear surface wave plasma source for tin removal in an extreme ultraviolet source

Tin deposition mitigation employs hydrogen radicals and ions, formed in a hydrogen plasma, to interact with tin to form tin hydride (SnH 4 ) in the gaseous state, which is then pumped away. Surface wave plasma (SWP) technology developed at Illinois generates hydrogen radicals and ions, resulting in tin etch rates that are high enough to keep extreme ultraviolet (EUV) lithographic tools clean. An advantage of an SWP antenna is the ability to generate a high density of hydrogen radicals and hydrogen ions directly at the desired etching location. In situ etching of tin enables high availability EUV tools by maintaining high reflectivity of the multilayer mirror of the collector. Additionally, the SWP is characterized with low ion energies and low electron temperature, such that the multilayer mirror does not suffer any damage from sputtering or implantation of hydrogen ions during operation. Here, experiments elucidating the fundamental processes of tin removal are conducted by varying pressure, power, surface temperature, and gas flow rate in order to observe the etch rate behavior. Our results have shown that the presence of hydrogen ions increases etch rates because ion bombardment weakens Sn–Sn bonds, which, in turn, allows for a higher rate of chemical etching by the radicals. The ion bombardment reduces the number of radicals needed to etch a single tin atom to the range of 10 2 –10 3 . The linear SWP antenna yields plasma densities on the order of 10 17 to 10 18 m -3 and radical densities on the order of 10 18 to 10 19 m -3 , allowing for greater utilization of ion etch enhancement. Etch rates of up to 200 nm/min have been achieved. The surface temperature of the samples is an important factor in the etching process such that the decrease in the surface temperature increases the etch rates and decreases the hydrogen desorption rates. In addition, a kinetic etch model is developed to explain the behavior of etch rates as a function of surface temperature. Furthermore, results from experiments performed in an Illinois NXE:3100 chamber will be discussed.

42 ENGINEERING↗

Meteorological and Soil Data from Ecohydrology Sensor Towers at Pump House and Snodgrass Mountain in East River Watershed, Colorado, 2019-2025

This data package includes hourly meteorological and soil sensor data at eight ecohydrology monitoring sites in East River Watershed, Colorado as part of the Watershed Function Scientific Focus Area (WFSFA) research led by Lawrence Berkeley National Lab (LBNL). Four field sites were located on the hillslope of East River (ER) near Pump House (PH) at Mount Crested Butte (ER-PHS1 to 4), and the other four are in the Snodgrass Mountain (SG) area (SG-EHS5 to 8). In terms of vegetation cover, three sites are in montane grasslands (ER-PHS1, ER-PHS2, and SG-EHS5), three are below evergreen conifer canopy (ER-PHS3, SG-EHS6, and SG-EHS7), and two are below deciduous aspen canopy (ER-PHS4 and SG-EHS8). The monitoring period began in October 2019 at the East River sites, in October 2020 at SG-EHS5 and SG-EHS6, and in October 2021 at SG-EHS7 and SG-EHS8. In September 2024, all four East River sites were fully retired. The four Snodgrass Mountain sites remain active. Each site is equipped with a comprehensive suite of meteorological sensors on a tripod and soil sensors that measure weather, energy fluxes, and soil variables. This data package includes measurements from ten different types of sensors and up to thirteen individual sensors per site, including (1) a weather station (measurement height ranges from 2.8~3.8 meters (m) above ground), (2) a quantum sensor for photosynthetic active radiation (PAR) (2.4~3.3m), (3) a net radiometer (1.7~2.1m), (4) an infrared radiometer (1.6~2.2m), (5) a sonic distance sensor (1.5~1.9m), (6) a soil carbon dioxide (CO2) flux chamber (0m), (7) a soil heat flux plate (-0.05m below ground), (8) a soil oxygen sensor (-0.3m), (9) a soil water potential sensor (-0.3m), and (10) soil water content sensors at 3~4 depths (-1.15 ~ -0.1m). A total of twenty-three variables is reported in this data package, including (1) atmospheric variables: air temperature (TA), atmospheric pressure (PA), vapor pressure (VP), and vapor pressure deficit (VPD), (2) precipitation variables: rain precipitation (P) and snow depth (D_SNOW), (3) energy fluxes variables: four-component net radiation (NETRAD) (shortwave/longwave incoming/outgoing radiation, SW_IN, SW_OUT, LW_IN, LW_OUT), photosynthetic photon flux density (PPFD), and soil heat flux (G), (4) soil variables: soil water content (SWC), soil water potential (SWP), soil temperature (TS), soil bulk electrical conductivity (COND_SOIL), and soil gaseous oxygen concentration (O2_SOIL), (5) wind variables: two-dimensional wind speed (WS), gust speed (WS_MAX), and wind direction (WD), and (6) surface variables: surface infrared temperature (T_CANOPY) and soil CO2 flux (CO2_SOIL). Please see the Methods section for data processing and QA/QC steps taken to generate the hourly datasets. The following files are included in this data package (notes on version: v{x}-{y}, where x is the metadata version, and y is the data version, when applicable): (1) “metadata_site_v{x}-{y}.csv” - a site metadata file that summarizes location information of all sites, including site ID, description, coordinates, timeframe, elevation, and vegetation cover, (2) “metadata_instrument_v{x}-{y}.csv” - an instrument metadata file that summarizes sensor information of all sites, including sensor manufacturer and model, measurement height, and sampling and averaging interval of all variables, (3) "data_{SITE_ID}_v{x}-{y}.csv" - eight data files that contain hourly data of each site indicated by {SITE_ID} in the filename, (4) “/figure/data_{SITE_ID}_v{x}-{y}.png" - eight figures that help visualize data of each site indicated by {SITE_ID} in the filename, (5) “/photo/*” - photos of each site indicated by {SITE_ID} in the filename, and (6) four file level metadata (flmd.csv) and data dictionary (*_dd.csv) files that summarize file, header, column, and variable information of all files. Notes: (1) Measurement height: Each variable name is followed by conventional positional qualifiers “H_V_R”, where H indicates the relative horizontal positions of that specific variable, V the vertical positions, and R the replicates. In this data package, only the vertical qualifier V varies, and V increases from the highest vertical position (V=1) to the lowest. Variables with the same qualifier are not necessarily measured by the same sensor, and the same variable with the same qualifier across different sites are not necessarily measured at the same height. Please refer to “metadata_instrument.csv” for the sensor information and measurement heights, and whether a variable is measured below the canopy. (2) Variable availability: Snow depth is not available at ER-PHS3 and SG-EHS7. SWC, soil temperature, and soil bulk EC at the deepest depth (<-1m) are not available at SG-EHS6 and SG-EHS7. The missing value code for numeric variables is -9999, except for SWP. For SWP, the missing value code is +9999, because SWP values are negative. (3) Sampling frequency: Please refer to “metadata_instrument.csv” for the increase of sampling frequency of some variables from 30-min to 1-min at ER-PHS1 to 4 in July 2020. (4) Sensors: While the methods of each sensor are not detailed, all sensors are commercially available, and their methods can be found in their manuals. Please refer to “metadata_instrument.csv” for the sensor manufacturer and model information. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Pitting Corrosion of 10Ni8CrMoV High-Strength Steel Induced by a Potential Perturbation

Pitting corrosion of high-strength steel 10Ni8CrMoV under square wave polarization (SWP) in simulated deep-sea environment is investigated and the possible mechanism is proposed. The results show that potential perturbation generates periodic intensification effect on both anodic and cathodic processes by frequently breaking the electrode equilibrium state. The intensity of periodic intensification effect essentially depends on the concentration gradient of Fe{sup 2+} cations at the steel/solution interface which acts as the forced electrochemical oscillator. The concentration gradient and the resulting concentration polarization effect increase periodically with the increase in SWP potential range. The morphology observation of the pitting and electric charge calculation indicate that the periodic intensification effect can promote the initiation and growth of pits by enhancing the anodic dissolution even under cathodic protection, but it is ineffective below the hydrogen evolution potential. The decrease in either upper or lower potential can mitigate anodic dissolution. Through the statistical analysis of pitting size, it is found that the wide potential range tends to activate the metastable pitting formed under hydrostatic pressure, forming densely distributed pitting. Meanwhile, it is more favorable to the formation of fully grown pits with high size dispersion degree when the proportion of electric charge in the anodic process is higher.

36 MATERIALS SCIENCE↗

Interpretation of Tracer Experiments on Inverted Five-spot Well-patterns within the Western Half of the Farnsworth Unit Oil Field

The Southwest Carbon Partnership (SWP), one of the U.S. Department of Energy (U.S. DOE) seven Regional Carbon Sequestration Partnerships, is currently working to demonstrate the utilization and storage of CO 2 in the Farnsworth Unit (FWU) Enhanced Oil Recovery (EOR) site under the final development phase of this U.S. DOE initiative. A component of the research is to use fluid tracers to understand the multifluid flow patterns that develop between injection and production wells via collected field data and supporting numerical reservoir models. The FWU, located in the Anadarko Basin, Ochiltree County, Texas, and being operated by Chaparral Energy, is a mature EOR water-flood field, which is currently being converted to a CO 2 flow, with inverted 5-spot patterns transitioning from pure water to alternating CO 2 and water floods (i.e., water alternating gas (WAG)) at an approximate rate of one every 6 to 10 months. The SWP tracer program is conducting a suite of tracer injections into the active 5-spot patterns at the FWU. Tracers have been selected to be nonreactive and either principally soluble in CO 2 (gas soluble) or water (aqueous soluble). In addition to characterizing the multifluid flow behaviour within reservoir, the gas and aqueous tracers have roles in detecting any leakage from the reservoir. A total of seven unique perfluorocarbon tracer (PFT) compounds make up the suite of gas soluble tracers and eight unique naphthalene sulfonate tracer (NPT) compounds comprise the aqueous soluble tracers. Lastly, all selected tracers are significantly detectable below the parts per billion concentrations, allowing for high resolution for the inter-well tests at relatively low injection volumes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of wave-mode conversion device on production of large-area rectangular overdense surface-wave plasmas at the gas pressure about 100 Pa

In this paper, the wave-mode conversion devices with three different structures have been devised for plasma heating. Surface-wave plasma (SWP) discharge analysis with or without considering the collision loss is presented theoretically. The comparative discharge experiments have been operated for obtaining the uniform stable microwave discharges. When a specially designed microwave appliance is selected as the proposed wave-mode conversion device, the discharges driven by resonant excitation with surface wave (SW) have yielded plasmas with density of about 10{sup 18} m{sup -3} at the gas pressure larger than 10 Pa. By comparing the results, the production of large-area uniform stable overdense SWP is attributed to the resonant excitation with SW evenly on the whole dielectric-plasma interface by the application of the specially designed wave-mode conversion device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Curling probe measurement of electron density in pulse-modulated plasma

The electron density n{sub e} of stationary plasma can be easily obtained on the basis of the resonance frequency f of a curling probe (CP) measured by a network analyzer (NWA). However, in pulsed plasma with discharge period T, the n{sub e} and f values periodically change with time. This study extends the conventional CP technique to a time-resolved measurement of the pulse-modulated electron density. The condition necessary for the measurement is revealed to be synchronization of NWA with the pulse modulation, which is expressed as (n − 1)T/T{sub SWP} = integer (1, 2, …) for a number n of data point and sweep time T{sub SWP}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tin removal by an annular surface wave plasma antenna in an extreme ultraviolet lithography source

Tin contamination of the collector mirror surface remains one of the crucial issues of EUV (Extreme Ultraviolet) sources, directly impacting the availability of the tool. Hydrogen plasma-based tin removal processes employ hydrogen radicals and ions to interact with tin deposits to form gaseous tin hydride (SnH 4 ), which can be removed through pumping. An annular surface wave plasma (SWP) source developed at the University of Illinois—Urbana Champaign is integrated into the cone and perimeter of the collection mirror for in situ tin removal. The SWP is characterized by high ion and radical densities, low electron temperature, and local generation where etching is needed. This method has the potential to significantly reduce downtime and increase mirror lifetime. Radical probe measurements show hydrogen radical densities in the order of 10 19 m -3 , while Langmuir probe measurements show electron temperatures of up to 6 eV and plasma densities on the order of 10 17–18 m -3 . The generated ions are essential to the tin cleaning and have sufficiently low energy to cause no damage to the collector capping layer. Tin etch rates of up to 270 nm/min were observed in a variety of experimental conditions, including various powers, pressures, flowrates, and temperatures. In conclusion, the high etch rates demonstrated in this study exceed the expected contamination rate of the EUV source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupled Geomechanical Modeling to Assess Cap Rock Integrity and Mechanical Fault Stability: Application to Farnsworth Field Unit Project

Abstract The SWP project is located in a mature waterflood undergoing conversion to CO2-WAG operations in the Farnsworth, Texas, USA. Anthropogenic CO2 is sourced from a fertilizer and an ethanol plant. This work utilizes Farnsworth’s full-field, history-matched, compositional hydrodynamic coupled geomechanical model for assessing the impact of stress changes observed through the history matched field life. Production and injection induced stress changes, fault stability and caprock integrity investigations are performed to project the potential for fault reactivation and the loss of caprock integrity under shear failure. A static mechanical earth model (MEM) was constructed for use in transient coupled geomechanical model based on the existing Southwest Regional Partnership (SWP) geological model. The static MEM inherits the stratigraphic and structural features of the geologic model and incorporates additional overburden, underburden, and sideburden formations required to impose mechanical boundary conditions. Mechanical properties were distributed in the 3D MEM through integration of geophysical logs and 3-dimensional seismic elastic inversion properties using a combination of Bayesian and stochastic interpolation methods. These data are further enhanced by lab derived strength and failure criteria for the caprock interval. Additionally, interpreted faults and other geological features were included as part of the static structural framework to fully represent subsurface hydraulic and mechanical systems and appropriately integrate heterogeneity. Two-way coupling of hydrodynamic flow and geomechanical simulations incorporates the Kozeny-Carman relationship for updating permeability and is history matched through primary, secondary (waterflooding) and tertiary (CO2 WAG) recovery periods before performing a twenty year forecast. Two-way simulations are performed to understand the effective stress perturbations imposed by field operations: water injection and the more recent implementation of WAG. Evaluation of Mohr circles with liquid production and field pressure charts as well as slip tendency and distance to failure metrics indicate that neither our faults or cap rock are critically stressed. This paper presents the results of the Farnsworth initial attempts to integrate the seismic driven 3D MEM into coupled hydrodynamic geomechanical history match simulation workflow.

02 PETROLEUM↗

Southwest Regional Partnership on Carbon Sequestration Phase II

The Southwest Regional Partnership (SWP) on Carbon Sequestration designed and deployed a medium-scale field pilot test of geologic carbon dioxide (CO2) sequestration in the Aneth oil field. Greater Aneth oil field, Utah's largest oil producer, was discovered in 1956 and has produced over 455 million barrels of oil (72 million m3). Located in the Paradox Basin of southeastern Utah, Greater Aneth is a stratigraphic trap producing from the Pennsylvanian Paradox Formation. Because it represents an archetype oil field of the western U.S., Greater Aneth was selected as one of three geologic pilots to demonstrate combined enhanced oil recovery (EOR) and CO2 sequestration under the auspices of the SWP on Carbon Sequestration, sponsored by the U.S. Department of Energy. The pilot demonstration focuced on the western portion of the Aneth Unit as this area of the field was converted from waterflood production to CO2 EOR starting in late 2007. The Aneth Unit is in the northwestern part of the field and has produced 149 million barrels (24 million m3) of the estimated 450 million barrels (71.5 million m3) of the original oil in place - a 33% recovery rate. The large amount of remaining oil makes the Aneth Unit ideal to demonstrate both CO2 storage capacity and EOR by CO2 flooding. This report summarizes the geologic characterization research, the various field monitoring tests, and the development of a geologic model and numerical simulations conducted for the Aneth demonstration project. The Utah Geological Survey (UGS), with contributions from other Partners, evaluated how the surface and subsurface geology of the Aneth Unit demonstration site will affect sequestration operations and engineering strategies. The UGS-research for the project are summarized in Chapters 1 through 7, and includes (1) mapping the surface geology including stratigraphy, faulting, fractures, and deformation bands, (2) describing the local Jurassic and Cretaceous stratigraphy, (3) mapping the Desert Creek zone reservoir, Gothic seal, and overlying aquifers, (4) characterizing the depositional environments and diagenetic events that produced significant reservoir heterogeneity, (5) describing the geochemical, petrographic, and geomechanical properties of the seal to determine the CO2 or hydrocarbon column it could support, and (6) evaluating the production history to compare primary production from vertical and horizontal wells, and the effects of waterflood and wateralternating- gas flood programs. The field monitoring demonstrations were conducted by various Partners including New Mexico Institute of Mining and Technology, University of Utah, National Institute of Advanced Industrial Science and Technology, Japan, Los Alamos National Laboratory and Cambridge Geosciences. The monitoring tests are summarized in Chapters 8 through 12, and includes (1) interwell tracer studies during water- and CO2-flood operations to characterize tracer behavoirs in anticipation of CO2-sequestration applications, (2) CO2 soil flux monitoring to measure background levels and variance and assess the sensitivity levels for CO2 surface monitoring, (3) testing the continuous monitoring of self potential as a means to detect pressure anomalies and electrochemical reaction due to CO2 injection, (4) conducting time-lapse vertical seismic profiling to image change near a CO2 injection well, and (5) monitoring microseismicity using a downhole string of seismic receivers to detect fracture slip and deformation associated with stress changes. Finally, the geologic modeling and numerical simulation study was conducted by researcher at the University of Utah. Chapter 13 summarizes their efforts which focused on developing a site-specific geologic model for Aneth to better understand and design CO2 storage specifically tailored to oil reservoirs.

02 PETROLEUM↗

Upscaling Methods Applied to a Fine-Scale Reservoir Model

This study was conducted as part of the Southwest Regional Partnership on Carbon Sequestration (SWP) project to evaluate how upscaling fine-scale simulation models to coarse-scale simulation models impacted the results. The focus was on the Farnsworth Unit (FWU) and its Morrow' B' Sandstone reservoir, specifically the west half of the field. Due to data limitations and the geologic characteristics of the surrounding area, the upscaling was limited to the west half of the FWU rather than a broader basinscale model. The primary aim was to explore how upscaling impacts numerical simulation models, particularly regarding CO 2 -enhanced oil recovery (EOR) and storage capacity predictions. Upscaling was necessary to reduce computational demands when transitioning from high-resolution geological models to coarser grids, as large-scale simulations with finer grids can be computationally prohibitive. This study expands on previous work by the SWP to understand how additional upscaling, applied to already fine-scale numerical simulation models, affects reservoir performance simulations (Ampomah, Balch, & Grigg, 2015). This is key to understanding how loss of resolution can affect coarsescale model results that may be used for large sensitivity analyses, uncertainty quantifications, and training data for machine learning applications.

02 PETROLEUM↗

Deposition, Diagenesis, and Sequence Stratigraphy of the Pennsylvanian Morrowan and Atokan Intervals at Farnsworth Unit

Farnsworth Field Unit (FWU), a mature oilfield currently undergoing CO2-enhanced oil recovery (EOR) in the northeastern Texas panhandle, is the study area for an extensive project undertaken by the Southwest Regional Partnership on Carbon Sequestration (SWP). SWP is characterizing the field and monitoring and modeling injection and fluid flow processes with the intent of verifying storage of CO2 in a timeframe of 100–1000 years. Collection of a large set of data including logs, core, and 3D geophysical data has allowed us to build a detailed reservoir model that is well-grounded in observations from the field. This paper presents a geological description of the rocks comprising the reservoir that is a target for both oil production and CO2 storage, as well as the overlying units that make up the primary and secondary seals. Core descriptions and petrographic analyses were used to determine depositional setting, general lithofacies, and a diagenetic sequence for reservoir and caprock at FWU. The reservoir is in the Pennsylvanian-aged Morrow B sandstone, an incised valley fluvial deposit that is encased within marine shales. The Morrow B exhibits several lithofacies with distinct appearance as well as petrophysical characteristics. The lithofacies are typical of incised valley fluvial sequences and vary from a relatively coarse conglomerate base to an upper fine sandstone that grades into the overlying marine-dominated shales and mudstone/limestone cyclical sequences of the Thirteen Finger limestone. Observations ranging from field scale (seismic surveys, well logs) to microscopic (mercury porosimetry, petrographic microscopy, microprobe and isotope data) provide a rich set of data on which we have built our geological and reservoir models.

04 OIL SHALES AND TAR SANDS↗

Evaluating the E3SM land model version 0 (ELMv0) at a temperate forest site using flux and soil water measurements

Accurate simulations of soil respiration and carbondioxide ( CO 2 ) fluxes are critical to project global biogeochemicalcycles and the magnitude of carbon–climate feedbacks in Earth system models(ESMs). Currently, soil respiration is not represented well in ESMs, and fewstudies have attempted to address this deficiency. In this study, weevaluated the simulation of soil respiration in the Energy Exascale EarthSystem Model (E3SM) land model version 0 (ELMv0) using long-termobservations from the Missouri Ozark AmeriFlux (MOFLUX) forest site in thecentral US. Simulations using the default model parameters underestimatedsoil water potential (SWP) during peak growing seasons and overestimated SWPduring non-growing seasons and consequently underestimated annual soilrespiration and gross primary production (GPP). A site-specific soil waterretention curve greatly improved model simulations of SWP, GPP, and soilrespiration. However, the model continued to underestimate the seasonal andinterannual variabilities and the impact of the extreme drought in 2012.Potential reasons may include inadequate representations of vegetationmortality, the soil moisture function, and the dynamics of microbialorganisms and soil macroinvertebrates. Our results indicate that thesimulations of mean annual GPP and soil respiration can be significantlyimproved by better model representations of the soil water retention curve.

54 ENVIRONMENTAL SCIENCES↗

Farnsworth Unit Gas Composition Analyses

This data set includes gas composition analyses that were provided to the Southwest Regional Partnership on Carbon Sequestration (SWP) by the operators of the Farnsworth Field Unit in Ochiltree County Texas.

CO2 CCUS,Farnsworth,Gas Compositions,Morrow Sandst↗