Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SURFACE CLEANING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Study of surface cleaning methods and pyrolysis temperatures on nanostructured carbon films using x-ray photoelectron spectroscopy

Nanostructured carbon (ns-C) films fabricated by stabilization and pyrolysis of diblock copolymers are of interest for a variety of electrical/electronic applications due to their chemical inertness, high-temperature insensitivity, very high surface area, and tunable electrical resistivity over a wide range [Kulkarni et al., Synth. Met. 159, 177 (2009)]. Because of their high porosity and associated high specific surface area, controlled surface cleaning studies are important for fabricating electronic devices from these films. In this study, quantification of surface composition and surface cleaning studies on ns-C films synthesized by carbonization of diblock copolymers of polyacrylonitrile-b-poly(n-butyl acrylate) at two different temperatures were carried out. X-ray photoelectron spectroscopy was used for elemental analysis and to determine the efficacy of various surface cleaning methods for ns-C films and to examine the polymer residues in the films. The in-situ surface cleaning methods included HF vapor treatment, vacuum annealing, and exposure to UV-ozone. Quantitative analysis of high-resolution XPS scans showed 11 at. % nitrogen was present in the films pyrolyzed at 600 Degree-Sign C, suggesting incomplete denitrogenation of the copolymer films. The nitrogen atomic concentration decreased significantly for films pyrolyzed at 900 Degree-Sign C confirming extensive denitrogenation at that temperature. Furthermore, quantitative analysis of nitrogen subpeaks indicated higher loss of nitrogen atoms residing at the edge of graphitic clusters relative to that of nitrogen atoms within the graphitic clusters, suggesting higher graphitization with increasing pyrolysis temperature. Of the surface cleaning methods investigated, in-situ annealing of the films at 300 Degree-Sign C for 40 min was found to be the most efficacious in removing adventitious carbon and oxygen impurities from the surface.

36 MATERIALS SCIENCE↗

Surface cleaning for enhanced adhesion to packaging surfaces: Effect of oxygen and ammonia plasma

The effects of direct plasma chemistries on carbon removal from silicon nitride (SiN{sub x}) and oxynitride (SiO{sub x}N{sub y}) surfaces have been studied by in-situ x-ray photoelectron spectroscopy (XPS) and ex-situ contact angle measurements. The data indicate that O{sub 2} and NH{sub 3} capacitively coupled plasmas are effective at removing adventitious carbon from silicon nitride (SiN{sub x}) and Si oxynitride (SiO{sub x}N{sub y}) surfaces. O{sub 2} plasma treatment results in the formation of a silica overlayer. In contrast, the exposure to NH{sub 3} plasma results in negligible additional oxidation of the SiN{sub x} or SiO{sub x}N{sub y} surface. Ex-situ contact angle measurements show that SiN{sub x} and SiO{sub x}N{sub y} surfaces exposed to oxygen plasma are initially more hydrophilic than surfaces exposed to NH{sub 3} plasma, indicating that the O{sub 2} plasma-induced SiO{sub 2} overlayer is highly reactive toward ambient. At longer ambient exposures (≳10 h), however, surfaces treated by either O{sub 2} or NH{sub 3} plasma exhibit similar steady state contact angles, correlated with rapid uptake of adventitious carbon, as determined by XPS. Surface passivation by exposure to molecular hydrogen prior to ambient exposure significantly retards the increase in contact angle upon exposure to ambient. The results suggest a practical route to enhancing the time available for effective bonding to surfaces in microelectronics packaging applications.

36 MATERIALS SCIENCE↗

LEEM investigations of clean surfaces driven by energetic ion beams

he original purpose of this award was to use low-energy electron microscopy (LEEM) to explore the dynamics of surfaces of clean single crystal surfaces when driven by a beam of energetic ions. The goal was to understand the nanoscience of hyperthermal growth, surface erosion by sublimation and irradiation, operation of surface sinks in irradiated materials, diffusion on driven surfaces, and the creation of structural patterns. This project was based on a novel LEEM system constructed by C. P. Flynn, which provided real-time imaging of surface dynamics by scattering low energy electrons. With the passing of Prof. Flynn in late 2011, this project was completed under a slightly different scope by constructing a low-energy, inelastic electron scattering (“EELS”) instrument. Consistent with Flynn’s original objectives for his LEEM system, this device (shown in Fig. 1) probes the dynamics of crystal surfaces. However the measurements are not carried out in real time, but instead are done in the frequency domain, through the energy lost from the probe electrons. The purpose of this device is to study the collective bosonic excitations in a variety of materials, including high temperature superconductors, topological insulators, carbon allotropes including (but not limited to) graphene, etc. The ultimate goal here is to identify the bosons that mediate interactions in these and other materials, with hopes of shedding light on the origin of many exotic phenomena including high temperature superconductivity.

36 MATERIALS SCIENCE↗

Indium stability on InGaAs during atomic H surface cleaning

Atomic H exposure of a GaAs surface at 390 deg. C is a relatively simple method for removing the native oxides without altering the surface stoichiometry. In-situ reflection high energy electron diffraction and angle-resolved x-ray photoelectron spectroscopy have been used to show that this procedure applied to In{sub 0.2}Ga{sub 0.8}As effectively removes the native oxides resulting in an atomically clean surface. However, the bulk InGaAs stoichiometry is not preserved from this treatment. The In:Ga ratio from the substrate is found to decrease by 33%. The implications for high-mobility channel applications are discussed as the carrier mobility increases nearly linearly with the In content.

36 MATERIALS SCIENCE↗

SnTe microcrystals: Surface cleaning of a topological crystalline insulator

Investigating nanometer and micron sized materials thought to exhibit topological surface properties that can present a challenge, as clean surfaces are a pre-requisite for band structure measurements when using nano-ARPES or laser-ARPES in ultra-high vacuum. This issue is exacerbated when dealing with nanometer or micron sized materials, which have been prepared ex-situ and so have been exposed to atmosphere. We present the findings of an XPS study where various cleaning methods have been employed to reduce the surface contamination and preserve the surface quality for surface sensitive measurements. Microcrystals of the topological crystalline insulator SnTe were grown ex-situ and transferred into ultra high vacuum (UHV) before being treated with either atomic hydrogen, argon sputtering, annealing, or a combination of treatments. The samples were also characterised using the scanning electron microscopy, both before and after treatment. It was found that atomic hydrogen cleaning with an anneal cycle (200 °C) gave the best clean surface results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clean surface processing of rubrene single crystal immersed in ionic liquid by using frequency modulation atomic force microscopy

Surface processing of a rubrene single crystal immersed in ionic liquids is valuable for further development of low voltage transistors operated by an electric double layer. We performed a precise and clean surface processing based on the tip-induced dissolution of rubrene molecules at the ionic liquid/rubrene single crystal interfaces by using frequency modulation atomic force microscopy. Molecular resolution imaging revealed that the tip-induced dissolution proceeded via metastable low density states derived from the anisotropic intermolecular interactions within the crystal structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of aluminum surface cleaning using cavitating fluid flow

This paper investigates efficiency of specially designed atomizer used to spray water and cavitate microbubbles in water flow. Surface cleaning system was used to clean machined (grinded) aluminum surface from abrasive particles. It is established that cleaning efficiency depends on diameter of the diffuser, water pressure and distance between nozzle and metal surface. It is obtained that the best cleaning efficiency (100%) is achieved at pressure 36 bar, when diameter of diffuser is 0.4 mm and distance between nozzle and surface is 1 mm. It is also established that satisfactory cleaning efficiency (80%) is achieved not only when atomizer is placed closer to metal surface, but also at larger (120 mm) distances.

36 MATERIALS SCIENCE↗

R&D Status for In-Situ Plasma Surface Cleaning of SRF Cavities at Spallation Neutron Source

The SNS SCL is reliably operating at 0.93 GeV output energy with an energy reserve of 10MeV with high availability. Most of the cavities exhibit field emission, which directly or indirectly (through heating of end groups) limits the gradients achievable in the high beta cavities in normal operation with the beam. One of the field emission sources would be surface contaminations during surface processing for which mild surface cleaning, if any, will help in reducing field emission. An R&D effort is in progress to develop in-situ surface processing for the cryomodules in the tunnel without disassembly. As the first attempt, in-situ plasma processing has been applied to the CM12 in the SNS SRF facility after the repair work with a promising result. This paper will report the R&D status of plasma processing in the SNS.

43 PARTICLE ACCELERATORS↗

Influence of plasma-based in-situ surface cleaning procedures on HfO{sub 2}/In{sub 0.53}Ga{sub 0.47}As gate stack properties

We report on the influence of variations in the process parameters of an in-situ surface cleaning procedure, consisting of alternating cycles of nitrogen plasma and trimethylaluminum dosing, on the interface trap density of highly scaled HfO{sub 2} gate dielectrics deposited on n-In{sub 0.53}Ga{sub 0.47}As by atomic layer deposition. We discuss the interface chemistry of stacks resulting from the pre-deposition exposure to nitrogen plasma/trimethylaluminum cycles. Measurements of interface trap densities, interface chemistry, and surface morphology show that variations in the cleaning process have a large effect on nucleation and surface coverage, which in turn are crucial for achieving low interface state densities.

36 MATERIALS SCIENCE↗

NOVEL METHODS FOR IN SITU HIGH DENSITY SURFACE CLEANING SCRUBBING OF ULTRAHIGH VAC LONG NARROW TUBES TO REDUCE SECONDARY ELECTRON YIELD AND OUT GASSING

This project developed new methods for cleaning the inside surfaces of very long, narrow vacuum tubes used in particle accelerators. Traditional cleaning approaches are expensive, slow, or difficult to implement in accelerator tunnels. We designed and tested a portable plasma discharge cleaning system that uses lower-cost microwave and magnetron technologies to reduce outgassing and secondary electron emission from stainless steel and copper surfaces. The system, called the Plasma Discharge Test System (PDTS), allows accelerator components to be scrubbed more efficiently, which can improve performance and reduce maintenance costs for research and industrial applications.

POOLE, JOE HENRY [PRESIDENT]↗

Molecular beam homoepitaxy of N-polar AlN: Enabling role of aluminum-assisted surface cleaning

N-polar aluminum nitride (AlN) is an important building block for next-generation high-power radio frequency electronics. We report successful homoepitaxial growth of N-polar AlN by molecular beam epitaxy (MBE) on large-area, cost-effective N-polar AlN templates. Direct growth without any in situ surface cleaning leads to films with inverted Al polarity. It is found that Al-assisted cleaning before growth enables the epitaxial film to maintain N-polarity. The grown N-polar AlN epilayer with its smooth, pit-free surface duplicates the structural quality of the substrate, as evidenced by a clean and smooth growth interface with no noticeable extended defects generation. Near band-edge photoluminescence peaks are observed at room temperature on samples with MBE-grown layers but not on the bare AlN templates, implying the suppression of nonradiative recombination centers in the epitaxial N-polar AlN.

42 ENGINEERING↗

Morphological stability of the atomically clean surface of silicon (100) crystals after microwave plasma-chemical processing

The morphological stability of atomically clean silicon (100) surface after low-energy microwave plasma-chemical etching in various plasma-forming media is studied. It is found that relaxation changes in the surface density and atomic bump heights after plasma processing in inert and chemically active media are multidirectional in character. After processing in a freon-14 medium, the free energy is minimized due to a decrease in the surface density of microbumps and an increase in their height. After argon-plasma processing, an insignificant increase in the bump density with a simultaneous decrease in bump heights is observed. The physicochemical processes causing these changes are considered.

36 MATERIALS SCIENCE↗

EUV mask surface cleaning effects on lithography process performance

The reflective, multilayer based, mask architectures for extreme ultraviolet (EUV) lithography are highly susceptible to surface oxidation and contamination. As a result, EUV masks are expected to undergo cleaning processes in order to maintain the lifetimes necessary for high volume manufacturing. For this study, the impact of repetitive cleaning of EUV masks on imaging performance was evaluated. Two, high quality industry standard, EUV masks are used for this study with one of the masks undergoing repeated cleaning and the other one kept as a reference. Lithographic performance, in terms of process window analysis and line edge roughness, was monitored after every two cleans and compared to the reference mask performance. After 8x clean, minimal degradation is observed. The cleaning cycles will be continued until significant loss imaging fidelity is found.

36 MATERIALS SCIENCE↗

Nonequilibrium atmospheric pressure plasma with ultrahigh electron density and high performance for glass surface cleaning

We produced a nonequilibrium atmospheric pressure plasma by applying an alternative current between two electrodes. The gas temperature and electron density were evaluated using optical emission spectroscopy. It was found that the plasma had gas temperatures from 1800 to 2150 K and ultrahigh electron densities in the order of 10{sup 16} cm{sup -3}. A remarkably high oxygen radical concentration of 1.6x10{sup 15} cm{sup -3} was obtained at a 1% O{sub 2}/Ar gas flow rate of 15 slm (standard liters per minute). Contact angles below 10 deg. were obtained in the process of glass cleaning with a plasma exposure time of 23 ms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Cleaning Techniques: Ultra-Trace ICP-MS Sample Preparation and Assay of HDPE

The world’s most sensitive radiation detection and assay systems depend upon ultra-low background (ULB) materials to reduce unwanted radiological backgrounds. Herein, we evaluate methods to clean HDPE, a material of interest to ULB systems and the means to provide rapid assay of surface and bulk contamination. ULB level material and ultra-trace level detection of actinide elements is difficult to attain, due to the introduction of contamination from sample preparation equipment such as pipette tips, sample vials, forceps, etc. and airborne particulate. To date, literature available on the cleaning of such polymeric materials and equipment for ULB applications and ultra-trace analyses is limited. For these reasons, a study has been performed to identify an effective way to remove surface contamination from polymers in an effort to provide improved instrumental detection limits. Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) was utilized to assess the effectiveness of a variety of leachate solutions for removal of inorganic uranium and thorium surface contamination from polymers, specifically high density polyethylene (HDPE). HDPE leaching procedures were tested to optimize contaminant removal of thorium and uranium. Calibration curves for thorium and uranium ranged from 15 ppq (fg/mL) to 1 ppt (pg/mL). Detection limits were calculated at 6 ppq for uranium and 7 ppq for thorium. Results showed the most effective leaching reagent to be clean 6 M nitric acid for 72 hour exposures. Contamination levels for uranium and thorium found in the leachate solutions were significant for ultralow level radiation detection applications.

HDPE, Leaching, Ultra-trace, ICP-MS, Uranium, Thor↗