Note: Control of liquid helium supply to cryopanels of Kolkata superconducting cyclotron

The Kolkata superconducting cyclotron utilises liquid helium to cool the main magnet niobium-titanium (NbTi) coil and the cryopanels. Three liquid helium cooled cryopanels, placed inside the dees of the radio-frequency system, maintain the high vacuum in the acceleration region of the superconducting cyclotron. The small cryostat placed inside the cryogenic distribution manifold located at the basement of the superconducting cyclotron building supplies liquid helium in parallel branches to three cold heads, used for cooling their associated cryopanels. The level in the cryostat has to be maintained at an optimum value to ensure uninterrupted flow of liquid helium to these three cold heads. This paper describes the transfer function of the overall system, its tuning parameters, and discusses the actual control of cryostat level by using these parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision phase control for the radio frequency system of K500 superconducting cyclotron at Variable Energy Cyclotron Centre, Kolkata

Variable Energy Cyclotron Centre (VECC) has commissioned K500 Superconducting cyclotron (SCC) based on MSU and Texas A and M university cyclotrons. The radio frequency (RF) system of SCC has been commissioned with the stringent requirement of various RF parameters. The three-phase RF system of Superconducting cyclotron has been developed in the frequency range 9–27 MHz with amplitude and phase stability of 100 ppm and ±0.1°, respectively. The phase control system has the option to change the relative phase difference between any two RF cavities and maintain the phase stability within ±0.1° during round-the-clock cyclotron operation. The said precision phase loop consists of both analogue In-phase/Quadrature modulator to achieve faster response and also Direct Digital Synthesis based phase shifter to achieve wide dynamic range as well. This paper discusses detail insights into the various issues of phase control for the K500 SCC at VECC, Kolkata.

43 PARTICLE ACCELERATORS↗

Radio frequency cavity analysis, measurement, and calibration of absolute Dee voltage for K-500 superconducting cyclotron at VECC, Kolkata

Variable Energy Cyclotron Centre has commissioned a K-500 superconducting cyclotron for various types of nuclear physics experiments. The 3-phase radio-frequency system of superconducting cyclotron has been developed in the frequency range 9-27 MHz with amplitude and phase stability of 100 ppm and {+-}0.2{sup 0}, respectively. The analysis of the RF cavity has been carried out using 3D Computer Simulation Technology (CST) Microwave Studio code and various RF parameters and accelerating voltages ('Dee' voltage) are calculated from simulation. During the RF system commissioning, measurement of different RF parameters has been done and absolute Dee voltage has been calibrated using a CdTe X-ray detector along with its accessories and known X-ray source. The present paper discusses about the measured data and the simulation result.

43 PARTICLE ACCELERATORS↗

Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

43 PARTICLE ACCELERATORS↗

Design and construction of a water target system for harvesting radioisotopes at the National Superconducting Cyclotron Laboratory

In this paper, a liquid water target system for harvesting radioisotopes at the National Superconducting Cyclotron Laboratory (NSCL) was designed and constructed as the initial step in proof-of-principle experiments to harvest useful radioisotopes from the Facility for Rare Isotope Beams (FRIB). FRIB will be a new national user facility for nuclear science, to be completed in 2020, at which radioisotopes will be collected synergistically from the water in cooling-loops for the primary beam dump that cycle the water at flow rates in excess of hundreds of gallons per minute. As part of the development of radiochemical expertise required to harvest long-lived radioisotopes of interest in this environment, the water target system described here was constructed and successfully used to collect a test beam of relativistic 24 Na ions produced at the NSCL. Finally, future studies will involve collecting interesting transition metal isotopes such as 67 Cu from less purified secondary projectile fragment beams.

07 ISOTOPE AND RADIATION SOURCES↗

Beam imaging in the injection line of the INFN-LNS superconducting cyclotron

A cheap and efficient diagnostic system for beam monitoring has been recently developed at INFN-LNS in Catania. It consists of a high sensitivity CCD camera detecting the light produced by an ion beam hitting the surface of a scintillating screen and a frame grabber for image acquisition. A scintillating screen, developed at INFN-LNS and consisting of a 2 μm BaF{sub 2} layer evaporated on an aluminium plate, has been tested by using {sup 20}Ne and {sup 40}Ar beams in the keV energy range. The CAESAR ECR ion source has been used for investigating the influence of the frequency and magnetic field tuning effects, the impact of the microwave injected power, and of the focusing solenoids along the low energy beam transport on the beam shape and current. These tests will allow to better understand the interplay between the plasma and beam dynamics and, moreover, to improve the transport efficiency along the low energy beam line and the matching with the superconducting cyclotron, particularly relevant in view of the expected upgrade of the machine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital data acquisition system implementation at the National Superconducting Cyclotron Laboratory

A Digital Data Acquisition System (DDAS) composed of 16-channel FPGA-programmable modules running 12-bit 100 Mega-Samples Per Second (MSPS) ADCs has been implemented on three different experimental arrays at the National Superconducting Cyclotron Laboratory (NSCL) encompassing charged particle spectroscopy, high and low energy-resolution photon detection, and neutron time-of-flight measurements. DDAS has increased the experimental capabilities of each array by providing energy and time measurements with nearly zero dead-time, low energy thresholds, and large dynamic range. The performance of the DDAS Analog-to-Digital Converters (ADC)s was characterized, and energy and time resolutions were compared with traditional analog systems. We have demonstrated a 14- to 15-bit peak-sensing equivalent resolution when applied to semiconductor detectors and 500 ps time resolution for LaBr 3 detectors measuring coincident radiation with signal amplitudes of ≈13% of the input range of the ADC. Details regarding the operation of the system at NSCL including digital filtering, triggering, clock distribution, and event-building are discussed along with applications to selected detector systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Commissioning of the LaBr 3 (Ce) detector array at the National Superconducting Cyclotron Laboratory

The timing and energy resolution properties of LaBr 3 (Ce) scintillators are well suited for use in γγ fast-timing experiments. Here, using standard 60 Co, 88 Y, and 152 Eu sources, the 16-element array of 1.5 inch by 1.5 inch right-cylindrical LaBr 3 (Ce) detectors and the associated readout electronics at the National Superconducting Cyclotron Laboratory were commissioned by measuring the lifetimes of excited states and the angular correlations of γ rays emitted in cascade. Excited-state lifetimes in 152 Sm and 152 Gd were measured using the exponential slope of the decay and a method based on the centroids of time-difference spectra. Results for the lifetimes are consistent with the well-known literature values which cover a range from a few picoseconds to several nanoseconds. Finally, the γγ angular correlations for the 4 + → 2 + → 0 + cascade in 60 Ni and the 3 - → 2 + → 0 + cascade in 88 Sr were measured and shown to agree with GEANT4 simulations that take into account the expected angular correlations within the cascades as well as the geometry of the array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An isotope harvesting beam blocker for the National Superconducting Cyclotron Laboratory

Harvesting isotopes from beam stops and other activated materials at accelerator facilities is a promising source of environmentally, scientifically and socially important radionuclides. At the Facility for Rare Isotope Beams (FRIB), a multitude of short- and long-lived radionuclides will be collected in a synergistic manner by dumping unused beams into a flowing-water beam stop. Ongoing exploratory research at the National Superconducting Cyclotron Laboratory (NSCL) with an analogous beam blocker aims towards obtaining the necessary radiochemical expertise for this endeavor. Herein we present a beam blocker and an isotope harvesting system which allows collection of a wide variety of aqueous and gaseous radionuclides. The water which flows through the beam blocker functions as an isotope production target and concurrently transports the newly formed radionuclides to collection sites. The system includes analytical instruments for online measurements of conductivity, dissolved oxygen, temperature, pressure and for detection of radiolytic products. To limit the levels of radiolytically produced hydrogen peroxide, a stainless-steel based degradation system was designed and implemented. Here, the suitability of the constructed system for the anticipated radionuclide harvesting project was demonstrated by offline tests and under irradiation with 140 MeV/u 48 Ca 20+ ions at the NSCL Coupled Cyclotron Facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A high-current electron gun for the electron beam ion trap at the National Superconducting Cyclotron Laboratory

The Electron Beam Ion Trap (EBIT) in NSCL’s reaccelerator ReA uses continuous ion injection and accumulation. In order to maximize capture efficiency and minimize breeding time into high charge states, the EBIT requires a high-current/high current-density electron beam. A new electron gun insert based on a concave Ba-dispenser cathode has been designed and built to increase the current transmitted through the EBIT’s superconducting magnet. With the new insert, stable EBIT operating conditions with 0.8 A of electron beam have been established. The design of the electron gun is presented together with calculated and measured perveance data. In order to assess the experimental compression of the electron beam, a pinhole CCD camera has been set up to measure the electron beam radius. The camera observes X-rays emitted from highly charged ions, excited by the electron beam. Initial tests with this camera setup will be presented. They indicate that a current density of 640 A/cm{sup 2} has been reached when the EBIT magnet was operated at 4 T.

43 PARTICLE ACCELERATORS↗

Harvesting 88 Zr from heavy-ion beam irradiated tungsten at the National Superconducting Cyclotron Laboratory

Tungsten is a commonly used material at many heavy-ion beam facilities, and it often becomes activated due to interactions with a beam. Many of the activation products are useful in basic and applied sciences if they can be recovered efficiently. In order to develop the radiochemistry for harvesting group (IV) elements from irradiated tungsten, a heavy-ion beam containing 88 Zr was embedded into a stack of tungsten foils at the National Superconducting Cyclotron Laboratory and a separation methodology was devised to recover the 88 Zr. The foils were dissolved in 30% hydrogen peroxide, and the 88 Zr was chemically purified from the tungsten matrix and from other co-implanted radionuclides (such as 85 Sr and 88 Y) using strong cation-exchange (AG MP-50) chromatographic resin in sulfuric acid media. The procedure provided 88 Zr in approximately 60 mL 0.5 M sulfuric acid with no detectable radio-impurities. The overall recovery yield for 88 Zr was (92.3 ± 1.2)%. In conclusion, this proof-of-concept experiment has facilitated the development of methodologies to harvest from tungsten and tungsten-alloy parts that are regularly irradiated at heavy-ion beam facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Harvesting 48V at the National Superconducting Cyclotron Laboratory

As part of a project to develop aqueous isotope harvesting techniques at radioactive beam facilities, 48 V and a cocktail of primary- and secondary-beam ions created by the fragmentation reaction of a 160 MeV/nucleon 58 Ni beam were stopped in an aqueous target cell. After collection, 48 V was separated from the mixture of beam ions using cation-exchange chromatography. The extraction efficiency from the aqueous solution was (47.0 ± 2.5)%, and the isolated 48 V had a radiochemical purity of 95.8%. This proof-of-concept work shows that aqueous isotope harvesting could provide significant quantities of rare isotopes which are currently unavailable at conventional facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Note: Neutron shutter for Kolkata superconducting cyclotron

In particle accelerator facilities, experimental areas are isolated from active accelerator area with thick concrete walls. A neutron shutter is used to isolate the experimental areas from the active accelerator area in the beam line. These shutters are provided primarily to reduce the secondary radiations like neutrons in the experimental areas to permissible limit when the primary beam is blocked in the accelerator area. The reduced radiation level in the experimental areas makes the experimental areas accessible. The shutters should allow the primary beam to pass to the experimental caves when they retracted from the beam line. A new neutron shutter has been designed and fabricated. This shutter incorporates compact features with considerable reduction in length, surface area and volume. The attenuation of secondary radiations is evaluated using Monte-Carlo radiation transport code FLUKA. It is found that the features of the shutter are sufficiently good enough to reduce the diffused secondary radiations well within the permissible levels.

43 PARTICLE ACCELERATORS↗

Multiple monoenergetic gamma radiography (MMGR) with a compact superconducting cyclotron

Smuggling of special nuclear materials and nuclear devices through borders and ports of entry constitutes a major risk to global security. Technologies are needed to reliably screen the flow of commerce for the presence of high-Z materials such as uranium and plutonium. Here, we present an experimental proof-of-concept of a technique that uses inelastic (p,p') nuclear reactions to generate monoenergetic photons, which provide means to measure the areal density and the effective-Z (Z eff ) of an object with an accuracy surpassing that achieved by current methods. We use an ION-12 SC superconducting 12 MeV proton cyclotron to produce 4.4, 6.1, 6.9, and 7.1 MeV photons from a variety of nuclear reactions. Using these photons in a transmission mode, we show that we are able to accurately reconstruct the areal densities and Zeff of a test object. This methodology could enable mobile applications to screen commercial cargoes with high material specificity, providing a means of distinguishing common cargo materials from high-Z materials that include uranium and plutonium.