Engineering PapersSearch

SEARCH · Engineering Papers

Results for “SUBMILLIMETER WAVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An adjustable RF tuning element for microwave, millimeter wave, and submillimeter wave integrated circuits

Planar RF circuits are used in a wide range of applications from 1 GHz to 300 GHz, including radar, communications, commercial RF test instruments, and remote sensing radiometers. These circuits, however, provide only fixed tuning elements. This lack of adjustability puts severe demands on circuit design procedures and materials parameters. We have developed a novel tuning element which can be incorporated into the design of a planar circuit in order to allow active, post-fabrication tuning by varying the electrical length of a coplanar strip transmission line. It consists of a series of thin plates which can slide in unison along the transmission line, and the size and spacing of the plates are designed to provide a large reflection of RF power over a useful frequency bandwidth. Tests of this structure at 1 GHz to 3 Ghz showed that it produced a reflection coefficient greater than 0.90 over a 20 percent bandwidth. A 2 GHz circuit incorporating this tuning element was also tested to demonstrate practical tuning ranges. This structure can be fabricated for frequencies as high as 1000 GHz using existing micromachining techniques. Many commercial applications can benefit from this micromechanical RF tuning element, as it will aid in extending microwave integrated circuit technology into the high millimeter wave and submillimeter wave bands by easing constraints on circuit technology.

Lubecke, Victor M.

Imaging front-end systems for millimeter waves and submillimeter waves

Imaging (multi-beam) front-end systems utilize a reflector or a lens, as well as a focal-plane array of receptor elements (beams). To be practical, such systems must utilize focal plane arrays which can be fabricated using hybrid integrated (and eventually monolithic) technology. This paper reviews alternative approaches to focussing elements, auxiliary devices required for local oscillator injection and similar functions, and focal plane arrays. It also discusses general limitations and advantages of these approaches, as well as typical applications to millimeter and submillimeter astronomical instrumentation.

Yngvesson, K. S.

Challenges and Techniques in Measurements of Noise, Cryogenic Noise and Power in Millimeter-Wave and Submillimeter-Wave Amplifiers

We will present the topic of noise measurements, including cryogenic noise measurements, of Monolithic Microwave Integrated Circuit (MMIC) and Sub-Millimeter-Wave Monolithic Microwave Integrated Circuit (S-MMIC) amplifiers, both on-wafer, and interfaced to waveguide modules via coupling probes. We will also present an overview of the state-of-the-art in waveguide probe techniques for packaging amplifier chips, and discuss methods to obtain the lowest loss packaging techniques available to date. Linearity in noise measurements will be discussed, and experimental methods for room temperature and cryogenic noise measurements will be presented. We will also present a discussion of power amplifier measurements for millimeter-wave and submillimeter-wave amplifiers, and the tools and hardware needed for this characterization.

Samoska, Lorene

Silicon micromachined waveguides for millimeter-wave and submillimeter-wave frequencies

Rectangular waveguide is commonly used up to high millimeter-wave frequencies. However, conventional machining techniques for waveguides operating above a few hundred GHz are complicated and costly. The development of silicon micro-machining techniques to create silicon-based waveguide circuits, which can operate up to high submillimeter-wave frequencies, is reported. As a first step, WR-10 waveguide has been fabricated from (110) silicon wafers. Insertion loss measurements of gold plated silicon waveguide show performance comparable to standard metal waveguides. It is suggested that active devices and planar circuits can be integrated with the waveguides, solving the traditional mounting problems.

Mcgrath, William R.

A Submillimeter Wave SIS Receiver for 547 GHz

The most sensitive heterodyne receivers used for millimeter wave and submillimeter wave radioastronomy employ superconductor-insulator-superconductor tunnel junctions as the nonlinear mixing element.

heterodyne receivers submillimeter wave SIS tunnel

Three-Stage InP Submillimeter-Wave MMIC Amplifier

A submillimeter-wave monolithic integrated- circuit (S-MMIC) amplifier has been designed and fabricated using an indium phosphide (InP) 35-nm gate-length high electron mobility transistor (HEMT) device, developed at Northrop Grumman Corporation. The HEMT device employs two fingers each 15 micrometers wide. The HEMT wafers are grown by molecular beam epitaxy (MBE) and make use of a pseudomorphic In0.75Ga0.25As channel, a silicon delta-doping layer as the electron supply, an In0.52Al0.48As buffer layer, and an InP substrate. The three-stage design uses coplanar waveguide topology with a very narrow ground-to-ground spacing of 14 micrometers. Quarter-wave matching transmission lines, on-chip metal-insulator-metal shunt capacitors, series thin-film resistors, and matching stubs were used in the design. Series resistors in the shunt branch arm provide the basic circuit stabilization. The S-MMIC amplifier was measured for S-parameters and found to be centered at 320 GHz with 13-15-dB gain from 300-345 GHz. This chip was developed as part of the DARPA Submillimeter Wave Imaging Focal Plane Technology (SWIFT) program (see figure). Submillimeter-wave amplifiers could enable more sensitive receivers for earth science, planetary remote sensing, and astrophysics telescopes, particularly in radio astronomy, both from the ground and in space. A small atmospheric window at 340 GHz exists and could enable ground-based observations. However, the submillimeter-wave regime (above 300 GHz) is best used for space telescopes as Earth s atmosphere attenuates most of the signal through water and oxygen absorption. Future radio telescopes could make use of S-MMIC amplifiers for wideband, low noise, instantaneous frequency coverage, particularly in the case of heterodyne array receivers.

Pukala, David

Ice Cloud Observations and Science using Submillimeter-Wave Radiometry

Submillimeter-wave radiometers provide vital information on ice clouds and precipitation. These data are key for improving weather forecasting, particularly for disruptive winter storms, and for better understanding climate. Our airborne radiometer will provide data that will allow us to better use data from upcoming space missions with these types of sensors.

Ian Adams

Submillimeter-Wave Cloud Ice Radiometry

Submillimeter-wave cloud ice radiometry is a new and innovative technique for characterizing cirrus ice clouds. Cirrus clouds affect Earth's climate and hydrological cycle by reflecting incoming solar energy, trapping outgoing IR radiation, sublimating into vapor, and influencing atmospheric circulation. Since uncertainties in the global distribution of cloud ice restrict the accuracy of both climate and weather models, successful development of this technique could provide a valuable tool for investigating how clouds affect climate and weather. Cloud ice radiometry could fill an important gap in the observational capabilities of existing and planned Earth-observing systems. Using submillimeter-wave radiometry to retrieve properties of ice clouds can be understood with a simple model. There are a number of submillimeter-wavelength spectral regions where the upper troposphere is transparent. At lower tropospheric altitudes water vapor emits a relatively uniform flux of thermal radiation. When cirrus clouds are present, they scatter a portion of the upwelling flux of submillimeter-wavelength radiation back towards the Earth as shown in the diagram, thus reducing the upward flux o f energy. Hence, the power received by a down-looking radiometer decreases when a cirrus cloud passes through the field of view causing the cirrus cloud to appear radiatively cool against the warm lower atmospheric thermal emissions. The reduction in upwelling thermal flux is a function of both the total cloud ice content and mean crystal size. Radiometric measurements made at multiple widely spaced frequencies permit flux variations caused by changes in crystal size to be distinguished from changes in ice content, and polarized measurements can be used to constrain mean crystal shape. The goal of the cloud ice radiometry program is to further develop and validate this technique of characterizing cirrus. A multi-frequency radiometer is being designed to support airborne science and spacecraft validation missions. This program has already extended the initial millimeter-wave modeling studies to submillimeter-wavelengths and has improved the realism of the cloud scattering models. Additionally a proof-of-concept airborne submillimeter-wave radiometer was constructed and fielded. It measured a radiometric signal from cirrus confirming the basic technical feasibility of this technique. This program is a cooperative effort of the University of Colorado, Colorado State University, Swales Aerospace, and Jet Propulsion Laboratory. Additional information is contained in the original.

Walter, Steven J.

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

A compact submillimeter wave transmission / reflection measurement system has been demonstrated at 560-635 GHz, with electronic tuning over the entire band. Maximum dynamic range measured at a single frequency is 90 dB (60 dB typical), and phase noise is less than +/- 2(deg). By using a frequency steerable lens at the source output and mixer input, the frequency agility of the system can be used to scan the source and receive beams, resulting in near real-time imaging capability using only a single pixel.

submillimeter wave imaging

CoSSIR: A New Instrument for Exploring the Utility of Submillimeter-wave Radiometry for Earth Observation

The Conical Scanning Submillimeter-wave Imaging Radiometer (CoSSIR) has been developed to study the application of submillimeter-wave radiometry for remote sensing of cirrus clouds and humidity sounding. Measurements of the global distribution of ice cloud mass and particle size are important for understanding the Earth s energy budget and for evaluating global climate models. The spatial variability and the wide variety of cloud particle shapes and sizes make ice clouds particularly difficult to measure. Ice clouds are essentially undetectable at microwave frequencies due to the low dielectric of ice and small size of the particles relative to wavelength. However, submillimeter wavelengths demonstrate significant response to the presence of ice clouds thus this frequency regime is applicable to measuring ice clouds. Another potentially viable application for submillimeter-wave radiometry is humidity and temperature sounding. The principle of sounding at submillimeter wavelengths is similar to that at microwavelengths. Submillimeter-wave radiometry has the advantage of achieving finer spatial resolution using a smaller antenna aperture which is an important consideration for spaceborne observatories. Submillimeter-wave radiometry also offers the potential of sounding over land and as a surrogate measurement for precipitation. CoSSIR is a new instrument to explore these applications. The CoSSIR is designed to fly aboard the ER-2 aircraft and its modest size (approximately 100 kg) permits it to be configured for other aircraft. A dual-axes gimbals mechanism provides conical, across-track, and along-track scanning capability. In its present configuration CoSSIR has fifteen channels between 183 GHz and 640 GHz. Three channels are centered about the 183 GHz water vapor absorption line, four channels are centered about the 380 GHz water vapor absorption line, and three dual-polarized channels are centered about the 487 GHz oxygen absorption line. Two channels are located in atmospheric windows at 220 GHz and 640 GHz. All channels are single-linear polarized with the exception of those near 487 GHz. Calibration is achieved by periodically observing two blackbody radiators; one blackbody is heated to approximately 325 K and the other is approximately 250 K during flight. Details of the instrument design as well as measurements from the Cirrus Regional Study of Tropical Anvils and Cirrus Layers - Florida Area Cirrus Experiment will be presented.

Racette, P. E.

Tunable Quantum-Well Submillimeter-Wave Oscillators

Tunable submillimeter-wave generator is layered (AI/Ga)As device. Frequencies adjusted via applied voltages. New device concept offers potential to make relatively compact, efficient local oscillators for heterodyne mixers in submillimeter radar and imaging systems, nondestructive testing, diagnosis of plasmas, airborne spectroscopy of atmosphere, detection of weapons and other contraband, and communications.

Maserjian, Joseph

Detection of upper atmospheric constituents using submillimeter wave /SMMW/ heterodyne radiometry

Submillimeter wave heterodyne radiometry has been applied to the detection and sounding of upper atmospheric constituents. The use of room-temperature Schottky-diode mixers for the receivers has yielded measurements of 70,000 K noise temperature. Coupling losses into the diode and matching of the IF output limit are observed to limit noise temperature. The technique is evaluated by calculating spectra with assumed temperature and constituent profiles. Vertical integrations are made with a multilayer atmosphere and the direct summation of absorption coefficients for the individual spectral lines is used. Results are presented for tangent path parameters for a mid-latitude summer model and the fractional parts of upper atmospheric constituents as a function of altitude.

Mcavoy, N.

The submillimeter wave astronomy satellite

The Submillimeter Wave Astronomy Satellite (SWAS) selected for flight as part of the Small Explorer Program is described. SWAS consists of a 55 by 71 cm near optical quality off axis primary mirror, two heteorodyne radiometers with Schottky barrier diode mixers, and a single broadband (1.4 GHz) Acousto Optical Spectrometer (AOS). SWAS primary objective is to conduct a high spectral resolution survey of galactic molecular clouds in low lying transitions of water, molecular oxygen, atomic carbon and isotopic carbon monoxide. These species are crucial in gaining a better understanding of the chemistry and cooling of dense molecular clouds.

Melnick, Gary J.

The Submillimeter Wave Astronomy Satellite

The Submillimeter Wave Astronomy Satellite (SWAS) mission is dedicated to the study of star formation and interstellar chemistry. To carry out this mission, SWAS will survey dense (n(sub H2) greater than 10(exp 3) cm(exp -3)) molecular clouds within our galaxy in either the ground-state of a low-lying transition of five astrophysically important species: H2O, H2O-18, O2, CI, and CO-13. By observing these lines SWAS will: (1) test long-standing theories that predict that these species are the dominant coolants of molecular clouds during the early stages of their collapse to form stars and planets, and (2) supply heretofore missing information about the abundanceof key species central to the chemical models of dense interstellar gas. SWAS will employ two independent Schottky barrier diode mixers, passively cooled to approx. 150 K, coupled to a highly efficient 54 x 68 cm off-axis Cassegrain antenna. During its two year mission, SWAS will observe giant and dark cloud cores with the goal of detecting or setting an upper limit on the water abundance of 3 x 10(exp -6) and on th molecular oxygen abundances of 2 x 10(exp -6), both relative to H2. In addition, advantage will be taken of SWAS's relatively large beamsize of 3.2 x 4.0 arcminutes at 551 GHz and 3.6 x 4.5 arcminutes at 492 GHz to obtain large-area (approx. 1 deg x 1 deg) maps of giant and dark clouds in the CO-13 and CI lines. SWAS is scheduled for launch in mid-1995.

Melnick, Gary J.

A compact 600 GHz electronically tunable vector measurement system for submillimeter wave imaging

A compact submillimeter wave transmission/reflection measurement system has been demonstrated at 560-635 GHz, with electronic tuning over the entire band. Maximum dynamic range measured at a single frequency is 100 dB (60 dB typical), and typical phase noise is less than +/- 1°. By using a frequency steerable lens at the source output and mixer input, the frequency agility of the system can be used to scan the source and receive beams, resulting in near realtime imaging capability using only a single pixel

Siegel, Peter H.

Demonstration of a 1-D Submillimeter-Wave Phased Array with MEMS Phase Shifters

At submillimeter-wave frequencies, due to the nonavailability of low-loss phase shifters, electronic antenna beam scanning is difficult to realize. Traditionally, power-hungry and bulky motors are used to mechanically scan the antenna beam. At lower-frequencies, phased array antennas are most commonly used where low-loss phase shifters are used with the array elements to accomplish beam steering. However, development of similar phased array antennas at submillimeter-waves has been challenging. Recently, we have developed a low-loss microelectromechanical systems (MEMS) based phased shifter in the 500-750 GHz band. In this work, we present a submillimeter-wave phased array antenna system with a cavity-backed double slot antenna architecture using the MEMS-based phase shifters. To demonstrate the concept, we developed two arrays: first one is a 8×1 linear antenna array with a fixed waveguide feeding network that achieved ±20◦ beam scanning, 18 dB directivity, and less than 1 dB scan loss over the design frequency of 500–570 GHz. The second one is a 4 × 1 linear antenna array with integrated MEMS-based phase shifters on each array element, achieving 15 dB directivity and capable of dynamic beam scanning over a range of ±9 ◦ . All the plots presented are simulated results since the parts are currently being fabricated. We hope to have access to our assembly and measurement facilities over the next few months and present measured performances at the conference.

Chattopadhyay, G.

The laboratory millimeter- and submillimeter-wave spectrum of CH3OD

The millimeter-wave and submillimeter-wave spectrum of CH3OD, a deuterated isotope of methanol known to be present in the interstellar medium, has been studied in the laboratory. Like all isotopes of methanol, CH3OD possesses a complex dense spectrum because of the phenomenon of internal rotation, sometimes referred to as torsional motion. Approximately 300 lines in the frequency range 130-700 GHz have been assigned. These lines involve transitions between rotational states with rotational quantum number J of not greater than 9 in both the A and the E substates of the lowest torsional state (v sub t = 0). The present data and previous data at lower frequencies (longer wavelengths) have been combined and analyzed by a procedure called the 'internal axis method'. The analysis yields spectral constants for CH3OD which, in turn, have been used to predict the frequencies of a number of other transitions of this species not measured in the laboratory.

Anderson, Todd

The submillimeter-wave spectrum of propionitrile (C2H5CN)

The laboratory millimeter-wave and submillimeter-wave rotational spectrum of propionitrile (ethyl cyanide, C2H5CN) in its ground vibrational state has been extended through J = 70 and K(sub a) = 36. Transitions measured in this study are in the frequency range 250-610 GHz. A fit of 952 transitions including 732 new measurements to a Watson A-reduced Hamiltonian has yielded a complete set of quartic and sextic distortion constants, in addition to six octic distortion constants. Internal rotation and hyperfine splittings have not been resolved, so they are not included in the analysis. Predicted transition frequencies for a large number of additional transitions of interest to radioastronomers are provided.

Pearson, J. C.