Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STRONTIUM 97”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A = 97

The 1993 evaluation of A = 97 (1993Ar09) was updated using data available prior to Nov. 19, 2009.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

90 Sr Liquid Scintillation Urine Analysis Utilizing Different Approaches for Tracer Recovery

90 Sr is one of the isotopes most commonly produced by nuclear fission. This medium lived isotope presents serious challenges to radiation workers, the environment, and following a nuclear event, the general public. Methods of identifying this nuclide have been in existence for a number of years (e.g. Horwitz, E.P. [1], Maxwell, S.L.[2], EPA 905.0 [3]) which are time consuming, requiring a month or more for full analysis. This time frame is unacceptable in the present security environment. It is therefore important to have a dependable and rapid method for the determination of Sr. The purposes of this study are to reduce analysis time to less than half a day by utilizing a single method of radiation measurement while continuing to yield precise results. This paper presents findings on three methods that can meet this criteria; (1) stable Sr carrier, (2) 85 Sr by gamma spectroscopy, and (3) 85 Sr by LSC. Two methods of analyzing and calculating the 85 Sr tracer recovery were investigated (gamma spectroscopy and a low energy window-Sr85LEBAB by LSC) as well as the use of two different types of Sr tracer ( 85 Sr and stable Sr carrier). Three separate stock blank urine samples were spiked with various activity levels of 239 Pu, 137 Cs, 90 Sr / 90 Y to determine the effectiveness of the Eichrome Sr-spec™ resin 2mL extractive columns. The objective was to compare the recoveries of 85 Sr versus a stable strontium carrier, attempt to compare the rate at which samples can be processed by evaluating evaporation, neutralization, and removing the use of another instrument (gamma spectrometer) by using the LSC spectrometer to obtain 85 Sr recovery. It was found that when using a calibration curve comprised of a different cocktail and a non-optimum discriminator setting reasonable results (bias of ± 25%) were achieved. The results from spiked samples containing 85 Sr demonstrated that a higher recovery is obtained when using gamma spectroscopy (89-95%) than when using the LEB window from LSC (120-470%). The high recovery for 85 Sr by LSC analysis may be due to the interference/cross talk from the alpha region since alpha counts were observed in all sample sets. After further investigation it was determined that the alpha counts were due to 239 Pu breakthrough on the Sr-spec™ column. This requires further development to purify the Sr before an accurate tracer recovery determination can be made. Sample preparation times varied and ranged from 4-6 hours depending on the specific sample preparation process. The results from the spiked samples containing stable strontium nitrate Sr(NO 3 ) 2 carrier demonstrate that gravimetric analysis yields the most consistent high recoveries (97-101%) when evaporation is carefully performed. Since this method did not have a variation on the tracer recovery method, the samples were counted in 1) LEB/Alpha/Beta mode optimized for Sr-90, 2) DPM for Sr-90, and 3) general LEB/Alpha/Beta mode. The results (from the known) ranged from 79-104%, 107-177%, and 85-89% for 1, 2, and 3 respectively. Counting the prepared samples in a generic low energy beta/alpha/beta protocol yielded more accurate and consistent results and also yielded the shortest sample preparation turn-around-time of 3.5 hours.

Piraner, Olga↗

High Performance Circuit Pastes for Solid Oxide Fuel Cell Applications: Final Technical Report

Using a combination of in-plane electrical conductivity measurements, electrical contact resistance measurements, tensile fracture tests, double shear lap fracture tests, rapid thermal cycling adhesion tests, in situ wetting angle measurements, 3D X-ray tomography, reduction-oxidation (RedOx) cycling, scanning electron microscopy (SEM), energy dispersive x-ray spectroscopy (EDAX), Density Functional Theory (DFT) modeling, Molecular Dynamics (MD) modeling, and Phase Field modeling, this project determined that a new brazing technique developed by the PIs (specifically the use of nickel particles to direct the wetting and spreading of molten silver) could be used to produce well-adhered, >97% dense, electrically-conductive circuits, current collectors, and/or electrical contacts on a variety of ceramic and ceramic-coated substrates (specifically lanthanum strontium manganite, yttria stabilized zirconia, sapphire, Cr2O3-passivated stainless steel, and Al2O3-passivated stainless steel). Compared to other silver-based alternatives, Ag:Ni led to less manufacturing defects and was more tolerant of the extreme environments (isothermal high-temperature aging) and occasional abuse (rapid thermal cycling and RedOx cycling) encountered during Solid Oxide Fuel Cell and/or Solid Oxide Electrolysis Cell operation. Further, in some situations (such as when to produce Ag:Ni electrical contacts to Al2O3-protected stainless steel) the Ni particles also improved operation by acting as chemical getters that removed electrically-insulating, surface-segregating substrate impurities (i.e. by lowering the contact resistance with the underlying substrate).

36 MATERIALS SCIENCE↗

Improved Cumulative Fission Yield Measurements with Fission Spectrum Neutrons on 235 U

Two isotopically-characterized targets of high-purity (99.84±0.03%) 235 U-oxide and a neutron dosimetry package were exposed to a pulsed neutron irradiation using the Godiva critical assembly at the National Criticality Experiments Research Center. Following irradiation, the fissioned targets were counted with a broad-energy germanium detector. Estimates of the total fissions for each target were made using measurements of well-known fission products. The total fission values were then used to measure the fission yields of 21 fission products with half-lives between 636 and 119,700 seconds. Mean values of seventeen of the measured fission products fell within the 95% confidence level of the Evaluated Nuclear Data Files VII.1/b (ENDF/B-VII.1) using the larger of the two uncertainties: 84g Br, 89 Rb, 91 Sr, 93 Y, 97 Zr, 101 Mo, 105 Ru, 128 Sn, 129 Sb, 130g Sb, 131 Sb, 131m Te, 133 I, 135 I, 141 Ba, 142 Ba, and 142 La. Seven isotopes were measured to better precision than is listed in the ENDF/B-VII.1 database: 89 Rb, 93 Y, 128 Sn, 129 Sb, 130g Sb, 131m Te, and 133 I. Four of the measured isotopes were found to be statistically different from the ENDF/B-VII.1 database: 94 Y, 134 Te, 134 I, and 138 Xe. Two of the isotopic analyses conducted in this paper fit the parent and daughter data simultaneously. The parent-daughter pairs measured in this way were the 134 Te/I and 142 Ba/La pairs. The fission yield results obtained in this way are unique, especially for 134 I, because the parent and daughter half-lives are so close. Here, given the limited number of direct measurements of the 134 Te/I pair from fast neutron induced fission and the seemingly high estimate for 134 Te from previous work, it is likely that the value in this paper is more accurate; however, additional measurements of this pair are needed to validate this assertion.

42 ENGINEERING↗

Exploring the Pb 1− x Sr x HfO 3 System and Potential for High Capacitive Energy Storage Density and Efficiency

Abstract The hafnate perovskites PbHfO 3 (antiferroelectric) and SrHfO 3 (“potential” ferroelectric) are studied as epitaxial thin films on SrTiO 3 (001) substrates with the added opportunity of observing a morphotropic phase boundary (MPB) in the Pb 1− x Sr x HfO 3 system. The resulting (240)‐oriented PbHfO 3 ( Pba 2) films exhibited antiferroelectric switching with a saturation polarization ≈53 µC cm −2 at 1.6 MV cm −1 , weak‐field dielectric constant ≈186 at 298 K, and an antiferroelectric‐to‐paraelectric phase transition at ≈518 K. (002)‐oriented SrHfO 3 films exhibited neither ferroelectric behavior nor evidence of a polar P 4 mm phase . Instead, the SrHfO 3 films exhibited a weak‐field dielectric constant ≈25 at 298 K and no signs of a structural transition to a polar phase as a function of temperature (77–623 K) and electric field (–3 to 3 MV cm −1 ). While the lack of ferroelectric order in SrHfO 3 removes the potential for MPB, structural and property evolution of the Pb 1− x Sr x HfO 3 (0 ≤ x < 1) system is explored. Strontium alloying increased the electric‐breakdown strength ( E B ) and decreased hysteresis loss, thus enhancing the capacitive energy storage density ( U r ) and efficiency (η). The composition, Pb 0.5 Sr 0.5 HfO 3 produced the best combination of E B = 5.12 ± 0.5 MV cm −1 , U r = 77 ± 5 J cm −3 , and η = 97 ± 2%, well out‐performing PbHfO 3 and other antiferroelectric oxides.

Acharya, Megha↗

Numerical evaluation of AGR-2 fission product release

The AGR-2 experiment produced normal operation and accident condition fuel performance data for tri-structural isotropic (TRISO) particles with UCO and UO 2 kernels. Data for compacts with no failed particles and for compacts with one or more failed particles are available. To model the fission product diffusion and release from these compacts, it is important to consider the computational mesh as well as the heat conduction and mass diffusion properties of the materials in a TRISO particle. Code and solution verification studies with the Bison fuel performance code were performed to show that the code is computing correct solutions. Bison comparisons to post-irradiation examination data and PARFUME predictions were made for several sets of compacts. Furthermore, these comparisons considered silver, cesium, strontium, and krypton with and without failed particles. Bison predictions closely match those of PARFUME, while both codes generally overpredict post-irradiation examination data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Macro- and Microstructures on Catalytic Hydrogenolysis of Polyolefins

Here, polyethylenes of varying molecular weight and branch density, as well as polypropylenes of varying molecular weight and tacticity, were catalytically converted to lower-molecular-weight liquid products to showcase how these various properties in a mixed waste plastic stream could affect the final product. A Pt nanoparticle on a strontium titanate nanocuboid (Pt/STO) catalyst was used under solvent-free conditions in the presence of 170 psi of H 2 at 300 °C for hydrogenolysis. The initial molecular weight of polyethylene was found to have a moderate effect on the yield to the final product (ranging from 55 wt% for M n ~ 7600 Da to 67 wt% for M n ~ 50,950 Da). The microstructure, defined as the length and density of branches in a polymer, of higher-molecular-weight polymers was the dominant factor in determining the yield (ranging from 67 wt% for M n ~ 50,950 Da for linear low-density polyethylene (LLDPE) with C 2 branches to 97 wt% for M n ~ 38,850 Da for LLDPE with C 6 branches). The same products (M n = C 29 –C 46 , Ð = 1.1–1.6) and distribution of undesired light gases (C 1 –C 4 ≈ 90 mol%, C 5 –C 8 ≈ 10 mol%) are obtained from conversions of PE of varying molecular weight. The tacticity of polypropylene at a given molecular weight had a significant effect on the molecular weight of the final product, while not strongly affecting conversion. Hydrogenolysis of isotactic polypropylene (iPP) produced ≈C 18 with a wider polydispersity (Ð ~ 1.4) compared to the narrow ≈C 64 (Ð ~ 1.0) and ≈C 54 (Ð ~ 1.0) products from atactic (aPP) and syndiotactic (sPP) polypropylene, respectively. The stereochemistry of the methyl groups dictates the shape and structure of the polymer in the melt, which in turn affects how the hydrocarbon chain interacts with the catalyst surface, thereby impacting the number of C–C scissions. These results show how various characteristics such as the molecular weight and structure of a waste plastic stream could affect the final product.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cohesive energy and structural parameters of binary oxides of groups IIA and IIIB from diffusion quantum Monte Carlo

We have applied the diffusion quantum Monte Carlo (DMC) method to calculate the cohesive energy and the structural parameters of the binary oxides CaO, SrO, BaO, Sc{sub 2}O{sub 3}, Y{sub 2}O{sub 3}, and La{sub 2}O{sub 3}. The aim of our calculations is to systematically quantify the accuracy of the DMC method to study this type of metal oxides. The DMC results were compared with local, semi-local, and hybrid Density Functional Theory (DFT) approximations as well as with experimental measurements. The DMC method yields cohesive energies for these oxides with a mean absolute deviation from experimental measurements of 0.18(2) eV, while with local, semi-local, and hybrid DFT approximations, the deviation is 3.06, 0.94, and 1.23 eV, respectively. For lattice constants, the mean absolute deviations in DMC, local, semi-local, and hybrid DFT approximations are 0.017(1), 0.07, 0.05, and 0.04 Å, respectively. DMC is a highly accurate method, outperforming the DFT approximations in describing the cohesive energies and structural parameters of these binary oxides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molybdenum Isotopes in Presolar Silicon Carbide Grains: Details of s -process Nucleosynthesis in Parent Stars and Implications for r - and p -processes

We have analyzed molybdenum isotopes, together with strontium and barium isotopes, in 18 presolar silicon carbide grains using the Chicago Instrument for Laser Ionization (CHILI), a resonance ionization mass spectrometer. All observed isotope ratios can be explained by mixtures of pure s-process matter with isotopically solar material. Grain residues were subsequently analyzed for carbon, nitrogen, silicon, and sulfur isotopes, as well as a subset for 26 Al– 26 Mg systematics using the NanoSIMS. These analyses showed that all but one grain are mainstream grains, most probably coming from low-mass asymptotic giant branch (AGB) stars. One grain is of the AB type, for which the origin is still a matter of debate. The high precision of molybdenum isotope measurements with CHILI provides the best estimate to date for s -process molybdenum made in low-mass AGB stars. The average molybdenum isotopic abundances produced by the s -process found in the analyzed mainstream SiC grains are 0% 92 Mo, 0.73% 94 Mo, 13.30% 95 Mo, 36.34% 96 Mo, 9.78% 97 Mo, 39.42% 98 Mo, and 0.43% 100 Mo. Solar molybdenum can be explained as a combination of 45.9% s -process, 30.6% r -process, and 23.5% p -process contributions. Moreover, the observed variability in the individual grain data provides insights into the variability of conditions (neutron density, temperature, and timescale) during s -process nucleosynthesis in the grains' parent stars, as they have subtle effects on specific molybdenum isotope ratios. Lastly, the results indicate that the ratio between p - and r -process molybdenum in presolar SiC from many different types of parent stars is Mo p /Mo r = 0.767, the value inferred for the solar system and consistent with what has been found in bulk samples and leachates of primitive meteorites.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-AB-201-06: Examining the Influence of Humidity On Reference Ion Chamber Performance

Purpose: International dosimetry protocols require measurements made with a vented ionization chamber to be corrected for the influence of air density by using the standard temperature-pressure correction factor. The effect of humidity, on the other hand, is generally ignored with the provision that the relative humidity is between certain limits (15% to 80%). However, there is little experimental data in the published literature as to the true effect of humidity on modern reference-class ion chambers. This investigation used two different radiation beams – a Co-60 irradiator and a Sr-90 check source – to examine the effect of humidity on several versions of the standard Farmer-type ion chamber. Methods: An environmental cabinet controlled the humidity. For the Co-60 beam, the irradiation was external, whereas for the Sr-90 measurements, the source itself was placed within the cabinet. Extensive measurements were carried out to ensure that the experimental setup provided reproducible readings. Four chamber types were investigated: IBA FC65-G (×2), IBA FC65-P, PTW30013 & Exradin A19. The different wall materials provided potentially different mechanical responses (i.e., in terms of expansion/contraction) to the water content in the air. The relative humidity was varied between 8 % and 97 % and measurements were made with increasing and decreasing humidity to investigate possible hysteresis effects. Results: Measurements in Co-60 were consistent with the published data obtained with primary standard cavity chambers in ICRU Report 31. Ionization currents with Sr-90 showed no dependence with the relative humidity, within the measurement uncertainties. Very good repeatability of the ionization current was obtained over successive wet/dry cycles, no hysteresis was observed, and there was no dependence on chamber type. Conclusion: This null result is very encouraging as it indicates that humidity has no significant effect on these particular types of ionization chambers, consistent with recommendations in current megavoltage dosimetry protocols.

60 APPLIED LIFE SCIENCES↗

Spin Glass Behavior in La{sub 0.7}Ca{sub 0.23}Sr{sub 0.07}MnO{sub 3} Nanofibers Obtained by Electrospinning

This work contributes to the development of new nanostructured mixed valence manganites and to explore and optimize their magnetic properties at 1-D level. Nanofibers of La{sub 0.7}Ca{sub 0.23}Sr{sub 0.07}MnO{sub 3} manganite were fabricated using the electrospinning method and three different heat treatments to determine how the nanostructure affects its thermomagnetic behavior. From scanning electron microscopy, nanofibers morphology was observed and average diameters of 75, 94, and 97 nm were identified after heat treatments of 973, 1073, and 1173 K, respectively. According to X-ray diffraction technique, a single-phase orthorhombic structure was defined for each sample. Average crystallite sizes were determined as 47, 49, and 58 nm. A ferromagnetic to paramagnetic transition with Curie temperatures of 297, 305, and 314 K were identified, respectively. Furthermore, a glassy state was induced by nanofibers agglomeration. The spin glass and irreversible temperatures diminished as the magnetic field was increased and a highly anisotropic state was evidenced for all samples. Thermomagnetic behavior in manganites showed to be significantly influenced by the one-dimensional structure and exposed how the dimensionality proportionated by the fabrication method can be used to adjust magnetic properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Hot Isostatically Pressed Ceramic Waste forms for High Dose Spent Adsorbents - 18129

Decommissioning and clean-up of nuclear facilities requires the development of new technologies to condition radioactive wastes, producing passively safe waste packages of minimal volume, to reduce storage and disposal costs. We have applied hot isostatic pressing to demonstrate conceptual waste forms for high dose spent adsorbents (i.e. ion exchange materials) present on the Sellafield site, UK, and Fukushima Daiichi site, Japan. These radioactive wastes pose several challenges which demand early conditioning to produce a passively safe wasteform, including: a wet and granular nature, and hence dispersible as a result of loss of containment; a very high dose rates as a result of their selectivity for short lived radionuclides (e.g. Sr-90, Cs-137, Co-60); radiogenic self-heating, as a result of the concentration of such lived radio nuclides; hydrogen production as a result of radiolysis of entrained water [1]. Here, we demonstrate the conversion of natural inorganic ion exchange materials into multiphase ceramic waste forms, achieving a waste loading of 100 wt.% and density in excess of 97% theoretical. High resolution thermogravimetric analysis coupled with mass spectroscopy was utilised to characterise the evolution of water and volatiles during the in-can bake out step, prior to the HIP cycle. This allowed optimisation of the bake out parameters (temperature, time and vacuum) to enable complete removal of water and volatiles, affording ceramic bodies with minimal residual porosity by hot isostatic pressing at 1250 deg. C for 4 h in stainless steel canisters. Characterisation of the ceramic waste forms by SEM /EDX and X-ray diffraction revealed the nuclides of concern to be incorporated within well-known natural mineral and synthetic phases, with Cs partitioning into the K-feldspar. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Composite Analysis: LLBG-200-W B Vadose Zone Model

The objectives of the vadose modeling for the updated Hanford Site Composite Analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates to the CA saturated zone model (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort: carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP 1 ) simulator, officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the saturated zone model. The rates will be summed over the 100 by 100 m saturated zone model grid cells that fall within the vadose zone model source domain.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculation of electron and isotopes dose point kernels with fluka Monte Carlo code for dosimetry in nuclear medicine therapy

Purpose: The calculation of patient-specific dose distribution can be achieved by Monte Carlo simulations or by analytical methods. In this study, fluka Monte Carlo code has been considered for use in nuclear medicine dosimetry. Up to now, fluka has mainly been dedicated to other fields, namely high energy physics, radiation protection, and hadrontherapy. When first employing a Monte Carlo code for nuclear medicine dosimetry, its results concerning electron transport at energies typical of nuclear medicine applications need to be verified. This is commonly achieved by means of calculation of a representative parameter and comparison with reference data. Dose point kernel (DPK), quantifying the energy deposition all around a point isotropic source, is often the one. Methods: fluka DPKs have been calculated in both water and compact bone for monoenergetic electrons (10{sup -3} MeV) and for beta emitting isotopes commonly used for therapy ({sup 89}Sr, {sup 90}Y, {sup 131}I, {sup 153}Sm, {sup 177}Lu, {sup 186}Re, and {sup 188}Re). Point isotropic sources have been simulated at the center of a water (bone) sphere, and deposed energy has been tallied in concentric shells. fluka outcomes have been compared to penelope v.2008 results, calculated in this study as well. Moreover, in case of monoenergetic electrons in water, comparison with the data from the literature (etran, geant4, mcnpx) has been done. Maximum percentage differences within 0.8{center_dot}R{sub CSDA} and 0.9{center_dot}R{sub CSDA} for monoenergetic electrons (R{sub CSDA} being the continuous slowing down approximation range) and within 0.8{center_dot}X{sub 90} and 0.9{center_dot}X{sub 90} for isotopes (X{sub 90} being the radius of the sphere in which 90% of the emitted energy is absorbed) have been computed, together with the average percentage difference within 0.9{center_dot}R{sub CSDA} and 0.9{center_dot}X{sub 90} for electrons and isotopes, respectively. Results: Concerning monoenergetic electrons, within 0.8{center_dot}R{sub CSDA} (where 90%-97% of the particle energy is deposed), fluka and penelope agree mostly within 7%, except for 10 and 20 keV electrons (12% in water, 8.3% in bone). The discrepancies between fluka and the other codes are of the same order of magnitude than those observed when comparing the other codes among them, which can be referred to the different simulation algorithms. When considering the beta spectra, discrepancies notably reduce: within 0.9{center_dot}X{sub 90}, fluka and penelope differ for less than 1% in water and less than 2% in bone with any of the isotopes here considered. Complete data of fluka DPKs are given as Supplementary Material as a tool to perform dosimetry by analytical point kernel convolution. Conclusions: fluka provides reliable results when transporting electrons in the low energy range, proving to be an adequate tool for nuclear medicine dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗