Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Setting and stiffening of cementitious components in Cast Stone waste form for disposal of secondary wastes from the Hanford waste treatment and immobilization plant

Cast Stone is a cementitious waste form, a viable option to immobilize secondary nuclear liquid wastes generated from the Hanford Waste Treatment and Immobilization Plant. However, no study has been performed to understand the flow and stiffening behavior, which is essential to ensure proper workability and is important to safety in a nuclear waste field-scale application. X-ray diffraction, rheology, and ultrasonic wave reflection methods were used to understand the specific phase formation and stiffening of Cast Stone. Our results showed a good correlation between rheological properties of the fresh mixture and phase formation in Cast Stone. Secondary gypsum formation was observed with low concentration simulants, and the formation of gypsum was suppressed in high concentration simulants. A threshold concentration for the drastic change in stiffening was found at 1.56 M Na concentration. It was found that the stiffening of Cast Stone was strongly dependent on the concentration of simulant. Highlights: • A combination of XRD, UWR, and rheology gives a better understanding of Cast Stone. • Stiffening of Cast Stone was strongly dependent on the concentration of simulant. • A drastic change in stiffening of Cast Stone was found at 1.56 M Na concentration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Protecting Space Travelers from Kidney Stones: Renal Stone Risk During Space Flight

Renal stones, popularly known as kidney or bladder stones, are small rock-like objects formed in the kidneys or urinary tract by deposits of calcium and other minerals. The problem arises when the stones block the drainage of the kidney, resulting in urinary obstruction and pain. Passing these stones can be one of the most painful experiences a person will endure so doctors often prescribe pain relievers to ease the experience. Drinking plenty of fluids, which help flush waste out of the body, and eating a well-balanced diet are the first steps to preventing stones. For individuals at risk, this may not be enough, and a doctor may recommend a special diet and medications. Unfortunately, approximately 60 percent of people who have had a renal stone will experience a recurrence. This is particularly true of men, who are four to five times more likely to develop stones than women. Renal stones do not discriminate based on age; even children are at risk. Astronauts are particularly at risk of developing renal stones because they lose bone and muscle mass; calcium, other minerals, and protein normally used for bone and muscle end up in the bloodstream and then in the kidneys. Without plenty of fluid to wash them away, crystals can form and then grow into stones. This factor compounds the risk for astronauts, since they also perceive that they are less thirsty in space and will drink less than normal during the mission. To minimize all of these factors, doctors must instead treat the stone-forming compounds with medication. This study will use potassium citrate to reduce the risk of stone formation. Renal stones are never convenient, but they are a particular concern for astronauts who have limited access to treatment during flight. Researchers are examining how earthbound preventions for renal stone formation work in flight, ensuring missions are not ended prematurely due to this medical condition. During STS-107, earthbound preventions and treatments become astronauts' gain.

Whitson, Peggy↗

Characterization of renal stone composition by using fast kilovoltage switching dual-energy computed tomography compared to laboratory stone analysis: a pilot study

Purpose: To prospectively examine the diagnostic performance of fast kilovoltage switching dual-energy computed tomography (DECT) in characterization of in vivo renal stone composition compared with postoperative stone analysis. Methods: Consecutive consenting patients scheduled for endoscopic kidney stone surgery in a tertiary referral hospital from June 2015 to January 2016 were enrolled. Patients were preoperatively scanned with single-source, fast kilovoltage switching DECT. Stone compositions were determined regarding the effective atomic number measurements. Results of the stone compositions from DECT were compared to postoperative infrared spectroscopy stone analysis as the standard reference. Results: For the 39 patients enrolled in the study, DECT was able to detect uric acid stone with sensitivity of 88.9% and specificity of 100%. There was 100% positive predictive value, 96.8% negative predictive value, and 97.4% accuracy. For non-contrast CT scan, sensitivity was 88.9%, specificity was 96.7%, positive predictive value was 88.9%, negative predictive value was 96.7%, and accuracy was 94.8%. Of the 39 samples examined, 21 (54%) were single composition, whereas 18 (46%) were combined. Single composition stones were correctly characterized by DECT in 100% (8/8) for uric acid. Whereas the result of uric acid stone containing stone discrimination in mixed composition was not so good with Z{sub eff} alone, iodine imaging can compensated this fault. Conclusions: DECT provides excellent accuracy in characterizing uric acid stone compositions. With the addition of iodine image, all of uric acid-containing stones can be determined by the DECT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monitoring for Renal Stone Recurrence in Astronauts With History of Stone

After an initial stone episode persons are at increased risk for future stone formation. A systematic approach is required to monitor the efficacy of treatment and preventive measures, and to assess the risk of developing new stones. This is important for persons working in critical jobs or austere environments, such as astronauts. A literature review of the current standards of care for renal stone monitoring and imaging was done. Military and civil aviation standards were also reviewed, as well as the medical precedents from the space program. Additionally, a new, more effective, renal stone ultrasound protocol has been developed. Using this work, a monitoring algorithm was proposed that takes into consideration the unique mission and operational environment of spaceflight. The approach to imaging persons with history of renal stones varies widely in the literature. Imaging is often done yearly or biannually, which may be too long for mission critical personnel. In the proposed algorithm astronauts with a history of renal stone, who may be under consideration for assignment, are imaged by a detailed, physiciandriven, ultrasound protocol. Unassigned personnel are monitored by yearly ultrasound and urine studies. Any positive ultrasound study is then followed by low-dose renal computed tomography scan. Other criteria are also established. The proposed algorithm provides a balanced approach between efficacy and reduced radiation exposure for the monitoring of astronauts with a renal stone history. This may eventually allow a transition from a risk-averse, to a risk-modifying approach that can enable continued service of individuals with history of renal stone that have adequately controlled risk factors.

Reyes, David P.↗

Evolution of Spaceflight Renal Stone Risks and Update to the NASA Human Research Program (HRP) Renal Stone Evidence Report and Integrated Concept of Operations

BACKGROUND: The NASA HRP Evidence Report on the Risk of Renal Stone Formation is being updated based on new information obtained from 9 years of data from NASA’s astronaut renal stone surveillance program. In addition, the Concept of Operations for missions beyond Low Earth Orbit (LEO) was created to supplement the Evidence Report, and the NASA clinical practice guideline(CPG)for renal stone surveillance was updated. OVERVIEW: A literature review was performed to evaluate the state of literature regarding renal stone prevention, mitigation, and management both in terrestrial and spaceflight environments. Current renal stone treatment guidelines for the ISS, which were created by the Inflight Clinical Medicine Working Group and approved by the Multilateral Medical Operations Panel (MMOP)were reviewed, as well as recent ultrasound technology demonstrations onboard the ISS. This information was used in conjunction with emerging evidence from the surveillance program to update the Evidence Report and in-flight Concept of Operations. DISCUSSION: There are known and emerging renal stone prevention strategies including astronaut selection, the use of medications and resistive exercise, early diagnosis with regular urine studies and ultrasound imaging. In-flight treatment options include pharmaceuticals, use of lithotripsy and propulsive ultrasound, placement of percutaneous drains and other modalities. This information is useful to gauge future risks and update our strategies for prevention and management of renal stones in astronauts to reduce the risk of in-flight renal stone colic that could cause morbidity and mission impact.

E Stratton↗

Effects of boron-nitride substrates on Stone-Wales defect formation in graphene: An ab initio molecular dynamics study

Ab initio molecular dynamics simulations are performed to investigate the effects of a boron nitride (BN) substrate on Stone-Wales (SW) defect formation and recovery in graphene. It is found that SW defects can be created by an off-plane recoil atom that interacts with the BN substrate. A mechanism with complete bond breakage for formation of SW defects in suspended graphene is also revealed for recoils at large displacement angles. In addition, further irradiation can result in recovery of the SW defects through a bond rotation mechanism in both graphene and graphene/BN, and the substrate has little effect on the recovery process. This study indicates that the BN substrate enhances the irradiation resistance of graphene.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of the Emissions and Crystalline Silica Content of Airborne Dust Generated from Grinding Natural and Engineered Stones

Abstract In this study, we systematically characterized the airborne dust generated from grinding engineered and natural stone products using a laboratory testing system designed and operated to collect representative respirable dust samples. Four stone samples tested included two engineered stones consisting of crystalline silica in a polyester resin matrix (formulations differed with Stones A having up to 90wt% crystalline silica and Stone B up to 50wt% crystalline silica), an engineered stone consisting of recycled glass in a cement matrix (Stone C), and a granite. Aerosol samples were collected by respirable dust samplers, total dust samplers, and a Micro-Orifice Uniform Deposit Impactor. Aerosol samples were analyzed by gravimetric analysis and x-ray diffraction to determine dust generation rates, crystalline silica generation rates, and crystalline silica content. Additionally, bulk dust settled on the floor of the testing system was analyzed for crystalline silica content. Real-time particle size distributions were measured using an Aerodynamic Particle Sizer. All stone types generated similar trimodal lognormal number-weighted particle size distributions during grinding with the most prominent mode at an aerodynamic diameter of about 2.0-2.3 μm, suggesting dust formation from grinding different stones is similar. Bulk dust from Stone C contained no crystalline silica. Bulk dust from Stone A, Stone B, and granite contained 60, 23, and 30wt% crystalline silica, respectively. In Stones A and B, the cristobalite form of crystalline silica was more plentiful than the quartz form. Only the quartz form was detected in granite. The bulk dust, respirable dust, and total dust for each stone had comparable amounts of crystalline silica, suggesting that crystalline silica content in the bulk dust could be representative of that in respirable dust generated during grinding. Granite generated more dust per unit volume of material removed than the engineered stones, which all had similar normalized dust generation rates. Stone A had the highest normalized generation rates of crystalline silica, followed by granite, Stone B, and Stone C (no crystalline silica), which likely leads to the same trend of respirable crystalline silica (RCS) exposure when working with these different stones. Manufacturing and adoption of engineered stone products with formulations such as Stone B or Stone C could potentially lower or eliminate RCS exposure risks. Combining all the effects of dust generation rate, size-dependent silica content, and respirable fraction, the highest normalized generation rate of RCS consistently occurs at 3.2-5.6 µm for all the stones containing crystalline silica. Therefore, removing particles in this size range near the generation sources should be prioritized when developing engineering control measures.

Public, Environmental & Occupational Health↗

Initial analysis of “stone” size Ryugu samples: current status

As a part of the initial analysis of the Ryugu samples, we perform a variety of analyses of millimeter-sized "stones". Our goals are to elucidate the entire formation process of C-type asteroid Ryugu from the viewpoint of petrology and mineralogy ande obtain necessary information by sample analysis, and then simulate the formation of Ryugu based on the evidencef obtained rom sample analysis. Eighteen stones (8 from Room A and 10 from Room C) were received from the ISAS curation facility on June 1, 2021, and brought into a fully nitrogen-displaced glove box at Tohoku University. At the same time, we also received the powder samples from Room A and Room C. To completely block the atmosphere from leaking into the container, all samples were put in the sample transport containers prepared by ISAS, transferred from the main chamber to the glovebox at ISAS, and then all containers were completely sealed in plastic bags with moisture and oxygen absorbers. No moisture or oxygen was detected when the bags were opened in the glove box at Tohoku University, so it was confirmed that there was no exposure to the atmosphere during transport. To date, a number of analyses have been carried out successfully and almost on schedule. The analysis started with the measurement of reflectance spectra, which are sensitive to atmospheric oxidation, hydroxylation, and adsorbed water. The visible, near-infrared, and mid-infrared reflectance spectra were measured while the samples were kept airtight. The spectra of powder samples and stone samples (as aggregates and as single stone) were successfully obtained. A major feature of the stone team's analysis is the use of synchrotron radiation facilities around the world. Since this analysis is non-destructive, stone samples whose reflectance spectra were measured were sent to KEK, SPring-8, ESRF (France), SOLEIL (France), DESY (Germany), and APS (USA). Using these synchrotron radiation facilities, high spatial resolution and sensitivity XRD, STXM, XANES, CT [1], IR-CT, FT-IR [2, 3], XRF, and Mössbauer analyses were performed. Most of the analyses were carried out under air-tight conditions on the stone samples and the particulates separated from the stone samples. These analyses allowed us to determine the three-dimensional distribution of minerals and elements, redox state, density and porosity of the stone samples. Furthermore, as a characteristic analysis of the stone team, light elemental analysis using negative Muon was performed at the MLF facility of J-PARC with an exceptionally long allocation of machine time. This is the only non-destructive method to measure the concentration of light elements in the whole (not the surface) of stone samples. Because the characteristic X-rays produced by muon irradiation are much higher in energy than the fluorescent X-rays produced by X-ray irradiation, there is little effect of self-absorption by the sample, and therefore, the concentration of light elements such as carbon, oxygen, and Na in the entire "stone" sample can be determined. Some stone samples are currently being measured for heat and strength physical properties in order to understand the physical properties of asteroid Ryugu. The data obtained from these measurements are useful for interpreting the remote-sensing data data taken from the surface layer of the asteroid Ryugu [4-7]. It is also important for understanding the behavior of the Ryugu material during impact events. The surfaces of many stone samples were observed by electron microscopy and other techniques, especially on natural “flat” surfaces formed on 5 stomes. As a result, characteristric mineral aggregates formed by the reactions with water and characteiristic impact features were observed on some of the samples. Based on the observations of surfaces and the synchrotron measurements of the whole stones, important objects such as characteristic structures and specific crystal aggregates for understanding the formation history of the asteroid were identified, and these parts were separated from the stone samples using an Xe beam (pFIB) and analyzed by various methods including transmission electron microscopy and synchrotron radiation analysis. Many stone samples, from which important objects have been separated, are embedded in epoxy resin and cut to produce many polished sections. Electron microscopy and spectroscopic measurements of the polished surfaces are being carried out to reveal the detailed mineralogical properties and elemental distribution inside the stone samples. In the fall, machine time for synchrotron radiation will begin, and we plan to analyze single crystals and characteristic objects separated from the stone samples.

Tomoki Nakamura↗

Estimating the Rate of Occurrence of Renal Stones in Astronauts

Changes in urine chemistry, during and post flight, potentially increases the risk of renal stones in astronauts. Although much is known about the effects of space flight on urine chemistry, no inflight incidence of renal stones in US astronauts exists and the question "How much does this risk change with space flight?" remains difficult to accurately quantify. In this discussion, we tackle this question utilizing a combination of deterministic and probabilistic modeling that implements the physics behind free stone growth and agglomeration, speciation of urine chemistry and published observations of population renal stone incidences to estimate changes in the rate of renal stone presentation. The modeling process utilizes a Population Balance Equation based model developed in the companion IWS abstract by Kassemi et al. (2016) to evaluate the maximum growth and agglomeration potential from a specified set of urine chemistry values. Changes in renal stone occurrence rates are obtained from this model in a probabilistic simulation that interrogates the range of possible urine chemistries using Monte Carlo techniques. Subsequently, each randomly sampled urine chemistry undergoes speciation analysis using the well-established Joint Expert Speciation System (JESS) code to calculate critical values, such as ionic strength and relative supersaturation. The Kassemi model utilizes this information to predict the mean and maximum stone size. We close the assessment loop by using a transfer function that estimates the rate of stone formation from combining the relative supersaturation and both the mean and maximum free stone growth sizes. The transfer function is established by a simulation analysis which combines population stone formation rates and Poisson regression. Training this transfer function requires using the output of the aforementioned assessment steps with inputs from known non-stone-former and known stone-former urine chemistries. Established in a Monte Carlo system, the entire renal stone analysis model produces a probability distribution of the stone formation rate and an expected uncertainty in the estimate. The utility of this analysis will be demonstrated by showing the change in renal stone occurrence predicted by this method using urine chemistry distributions published in Whitson et al. 2009. A comparison to the model predictions to previous assessments of renal stone risk will be used to illustrate initial validation of the model.

gravitational physiology↗

Rapid kVp switching dual-energy CT in the assessment of urolithiasis in patients with large body habitus: preliminary observations on image quality and stone characterization

Purpose: The purpose of this study was to investigate the image quality (IQ) considerations of rapid kVp switching dual-energy CT (rsDECT) in the assessment of urolithiasis in patients with large body habitus and to evaluate whether it allows stone characterization. Materials and methods: In this IRB-approved, HIPAA compliant retrospective study, 93 consecutive patients (M/F = 72/21, mean age 56.9 years, range 23–83 years) with large body habitus (> 90 kg/198 lbs) who underwent dual-energy (DE) stone protocol CT on a rapid kVp switching DECT scanner between January 2013 and December 2016 were included. Scan acquisition protocol included an initial unenhanced single-energy CT (SECT) scan of KUB followed by targeted DECT in the region of stones. Two readers evaluated both CT data sets (axial 5 mm 120 kVp/140 kVp QC/70 keV monoenergetic, material density water/iodine images and coronal/sagittal 3 mm images) for the assessment of image quality (Scores: 1–4) and characterization of stone composition (reference standard: crystallography). Results: One hundred and five CT examinations were performed in 93 patients (mean body weight 105.12 ± 13.53 kg, range 91–154 kg), and a total of 321 urinary tract calculi (mean size-4.8 ± 3.2 mm, range 1.2–22 mm) were detected. Both SECT and targeted monoenergetic images were of acceptable image quality (mean IQ: 3.77 and 3.83, kappa 0.79 and 0.87 respectively). Material density water and iodine images had lower IQ scores (mean IQ: 2.97 and 3.09 respectively) with image quality deterioration due to severe photon starvation/streak artifacts in 20% (21/105) and 17% (18/105) scans, respectively. Characterization of stone composition into uric acid/non-uric acid stones was achieved in 93.14% (299/321) of calculi (mean size: 4.99 ± 3.3 mm, range 1.2–22 mm), while 7% (22/321) stones could not be characterized (mean size 3.03 ± 1.16 mm, range 1.6–6.4 mm) (p < 0.001). Most common reason for non-characterization was image quality deterioration of the material density iodine images due to severe photon starvation artifacts. On multivariate regression, stone size and patient weight were predictors of stone composition determination on DECT (p < 0.05). The transverse diameter had a weak negative correlation with stone composition determination, but it was not statistically significant. Stone characterization into uric acid vs. non-uric acid stones was accurate in 95% (n = 38/40) of stones in comparison with crystallography. Conclusion: In patients with large body habitus, rsDECT allowed characterization of most calculi (93%) despite image quality deterioration due to photon starvation/streak artifacts in up to 20% of material density images. Stone size and patient weight were predictors of stone composition determination on DECT, and small calculi in very large patients may not be characterized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Letter Report: LAW Simulant Development for Cast Stone Screening Test

More than 56 million gallons of radioactive and hazardous waste are stored in 177 underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in southeastern Washington State. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is being constructed to treat the wastes and immobilize them in a glass waste form. The WTP includes a pretreatment facility to separate the wastes into a small volume of high-level waste (HLW) containing most of the radioactivity and a larger volume of low-activity waste (LAW) containing most of the nonradioactive chemicals. The HLW will be converted to glass in the HLW vitrification facility for ultimate disposal at an offsite federal repository. At least a portion (~35%) of the LAW will be converted to glass in the LAW vitrification facility and will be disposed of onsite at the Integrated Disposal Facility (IDF). The pretreatment and HLW vitrification facilities will have the capacity to treat and immobilize the wastes destined for each facility. However, a second facility will be needed for the expected volume of additional LAW requiring immobilization. A cementitious waste form known as Cast Stone is being considered to provide the required additional LAW immobilization capacity. The Cast Stone waste form must be acceptable for disposal in the IDF. The Cast Stone waste form and immobilization process must be tested to demonstrate that the final Cast Stone waste form can comply with waste acceptance criteria for the IDF disposal facility and that the immobilization processes can be controlled to consistently provide an acceptable waste form product. Further, the waste form must be tested to provide the technical basis for understanding the long term performance of the waste form in the IDF disposal environment. These waste form performance data are needed to support risk assessment and performance assessment (PA) analyses of the long-term environmental impact of the waste disposal in the IDF. A testing program was developed in fiscal year (FY) 2012 describing in some detail the work needed to develop and qualify Cast Stone as a waste form for the solidification of Hanford LAW (Westsik et al. 2012). Included within Westsik et al. (2012) is a section on the near-term needs to address Tri-Party Agreement Milestone M-062-40ZZ. The objectives of the testing program to be conducted in FY 2013 and FY 2014 are to: • Determine an acceptable formulation for the LAW Cast Stone waste form. • Evaluate sources of dry materials for preparing the LAW Cast Stone. • Demonstrate the robustness of the Cast Stone waste form for a range of LAW compositions. • Demonstrate the robustness of the formulation for variability in the Cast Stone process. • Provide Cast Stone contaminant release data for PA and risk assessment evaluations. The first step in determining an acceptable formulation for the LAW Cast Stone waste form is to conduct screening tests to examine expected ranges in pretreated LAW composition, waste stream concentrations, dry-materials sources, and mix ratios of waste feed to dry blend. A statistically designed test matrix will be used to evaluate the effects of these key parameters on the properties of the Cast Stone as it is initially prepared and after curing. The second phase of testing will focus on selection of a baseline Cast Stone formulation for LAW and demonstrating that Cast Stone can meet expected waste form requirements for disposal in the IDF. It is expected that this testing will use the results of the screening tests to define a smaller suite of tests to refine the composition of the baseline Cast Stone formulation (e.g. waste concentration, water to dry mix ratio, waste loading).

Russell, Renee L.↗

Renal Stone Risk During Space Flight

Space flight produces a number of metabolic and physiological changes in the crewmembers exposed to microgravity. Following launch, body fluid volumes, electrolyte levels, and bone and muscle undergo changes as the human body adapts to the weightless environment. Changes in the urinary chemical composition may lead to the potentially serious consequences of renal stone formation. Previous data collected immediately after space flight indicate changes in the urine chemistry favoring an increased risk of calcium oxalate and uric acid stone formation (n = 323). During short term Shuttle space flights, the changes observed include increased urinary calcium and decreased urine volume, pH and citrate resulting in a greater risk for calcium oxalate and brushite stone formation (n = 6). Results from long duration Shuttle/Mir missions (n = 9) followed a similar trend and demonstrated decreased fluid intake and urine volume and increased urinary calcium resulting in a urinary environment saturated with the calcium stone-forming salts. The increased risk occurs rapidly upon exposure to microgravity, continues throughout the space flight and following landing. Dietary factors, especially fluid intake, or pharmacologic intervention can significantly influence the urinary chemical composition. Increasing fluid intake to produce a daily urine output of 2 liters/day may allow the excess salts in the urine to remain in solution, crystals formation will not occur and a renal stone will not develop. Results from long duration crewmembers (n = 2) who had urine volumes greater than 2.5 L/day minimized their risk of renal stone formation. Also, comparisons of stone-forming risk in short duration crewmembers clearly identified greater risk in those who produced less than 2 liters of urine/day. However, hydration and increased urine output does not correct the underlying calcium excretion due to bone loss and only treats the symptoms and not the cause of the increased urinary salts. Dietary modification and promising pharmacologic treatments may also be used to reduce the potential risk for renal stone formation. Potassium citrate is being used clinically to increase the urinary inhibitor levels to minimize the development of crystals and the growth of renal stones. Bisphosphonates are a class of drugs recently shown to help in patients with osteoporosis by inhibiting the loss of bones in elderly patients. This drug could potentially prevent the bone loss observed in astronauts and thereby minimize the increase in urinary calcium and reduce the risk for renal stone development. Results of NASA's renal stone risk assessment program clearly indicate that exposure to microgravity changes the urinary chemical environment such that there is an increased risk for supersaturation of stone-forming salts, including calcium oxalaie and brushite. These studies have indicated specific avenues for development of countermeasures for the increased renal stone risk observed during and following space flight. Increased hydration and implementation of pharmacologic countermeasures should largely mitigate the in-flight risk of renal stones.

Whitson, Peggy A.↗

Simulating field conditions for the curing of salt-stone - 15501

salt-stone is a cementitious, low-level waste (LLW) material processed and stored at the Savannah River Site (SRS). It consists of fly ash (FA), blast furnace slag (BFS), and Portland cement that are blended with LLW salt solution. The dry feed materials and the salt solution are mixed at the salt-stone Production Facility (SPF), and the fresh grout subsequently pumped into a salt-stone Disposal Unit (SDU) in the salt-stone Disposal Facility (SDF) where it cures to form a rigid, cementitious monolith. In order to demonstrate the long-term performance of salt-stone, non-radioactive simulant samples are processed and cured in a laboratory environment and subsequently tested with respect to key performance properties. Of particular relevance to assessing the long-term stabilization and immobilization of radionuclides in salt-stone is the permeability, or saturated hydraulic conductivity, which determines the rate of infiltration for oxygen-bearing ground waters that can affect redox sensitive contaminants, such as {sup 99}Tc. Environmental conditions in the SDU, in particular temperature and humidity, are believed to affect the cured properties of salt-stone. With respect to humidity it has been determined that the average vapor space humidity in an SDU is at least 95%, and in addition the assumption can be made that underlying grout is subjected to a moisture-saturated environment by the grout poured over it. With respect to temperature, the SDUs contain thermo-well arrays that provide detailed vertical, and to a lesser degree radial, temperature profiles. Temperature data from the SDUs have subsequently been utilized to better simulate curing temperatures for simulant salt-stone in the laboratory. However, no two thermal profiles are the same, varying with respect to the following parameters: initial temperature, rate of temperature increase, maximum temperature attained, time at maximum temperature, and cooling rate. These temperature variables are dependent on the depth of grout (due to insulating effects of underlying and overlying grout), frequency of grout addition to the SDU (with more frequent additions causing grout temperatures to rise due to the exothermic hydration reactions), and, to a lesser degree, the ambient temperature of the external environment. Due to the variability in each thermal profile recorded in an SDU, the question arises as to which profile (or profiles) should be used in the simulated laboratory environment to best mimic the curing of field emplaced salt-stone, such that there is confidence that the properties measured for laboratory-prepared samples are representative of the grout in the SDU. Since the current SDU design contains sixty-six thermo-wells it is obviously not practical to process simulant samples according to each profile. Rather the aim would be to choose a reduced number of profiles that adequately encompass the range of recorded profiles, or to choose a single profile that is considered most conservative with respect to the resulting properties of interest. This is typically thought to be the profile exhibiting the highest peak temperature since for cement-based materials higher curing temperatures (> 60 deg. C), while resulting in enhanced reaction kinetics and strength development for short curing durations (∼28 days), have been shown to adversely affect the physical properties of the material after extended cure times. In choosing representative profiles it is important to consider not only the maximum temperature, but also the influence of rate of temperature rise to the maximum temperature, and time at or close to the maximum temperature on the post-cured properties. The intent of this paper is to consider the varied curing temperature profiles to which the salt-stone is exposed in an SDU, and to analyze the currently available data for elevated temperature curing of salt-stone to determine the potential thermal effects on the saturated hydraulic conductivity of salt-stone emplaced in an SDU. This may subsequently facilitate a more informed approach to simulating the curing of salt-stone in a laboratory environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An association between urinary cadmium and urinary stone disease in persons living in cadmium-contaminated villages in northwestern Thailand: A population study

Excessive urinary calcium excretion is the major risk of urinary stone formation. Very few population studies have been performed to determine the relationship between environmental cadmium exposure and urinary stone disease. This population-based study examined an association between urinary cadmium excretion, a good biomarker of long-term cadmium exposure, and prevalence of urinary stones in persons aged 15 years and older, who lived in the 12 cadmium-contaminated villages in the Mae Sot District, Tak Province, northwestern Thailand. A total of 6748 persons were interviewed and screened for urinary cadmium and urinary stone disease in 2009. To test a correlation between urinary excretion of cadmium and calcium, we measured urinary calcium content in 1492 persons, who lived in 3 villages randomly selected from the 12 contaminated villages. The rate of urinary stones significantly increased from 4.3% among persons in the lowest quartile of urinary cadmium to 11.3% in the highest quartile. An increase in stone prevalence with increasing urinary cadmium levels was similarly observed in both genders. Multiple logistic regression analysis revealed a positive association between urinary cadmium levels and stone prevalence, after adjusting for other co-variables. The urinary calcium excretion significantly increased with increasing urinary cadmium levels in both genders, after adjusting for other co-variables. Elevated calciuria induced by cadmium might increase the risk of urinary stone formation in this environmentally exposed population. - Research highlights: {yields} Excessive calciuria is the major risk of urinary stone formation. {yields} We examine cadmium-exposed persons for urinary cadmium, calcium, and stones. {yields} The rate of urinary stones increases with increasing urinary cadmium. {yields} Urinary calcium excretion increases with increasing urinary cadmium. {yields} Elevated calciuria induced by cadmium may increase the risk of urinary stones.

60 APPLIED LIFE SCIENCES↗

The Effect of Positioning on Ureteral Stone Retropulsion: “Gravity Works”

To evaluate the potential impact of alterations in “patient” position on laser-induced ureteral stone retropulsion in an in vitro model. In this paper, a ceramic (phantom) stone was placed in a water-filled clear polymer tube and subjected to continuous laser energy until the stone had retropulsed a distance of 10cm. The trial was stopped after 60 seconds if the stone had not reached 10cm. The time and total energy needed to cause 10cm of retropulsion were recorded at an incline angle of 0°, 10°, 20°, and 40°; ten trials at each angle were completed. The study was then repeated with pure calcium phosphate brushite stones. Retropulsion decreased with increasing incline angle of the saline-filled clear polymer tube. At 0° of incline the phantom stone reached a distance of 10cm after 7.4 seconds. At 10°, 20°, and 40° the phantom stone migrated a mean maximum distance of 3.1 cm, 1.2 cm, and 0.7 cm, respectively, and the trial was stopped after 60 seconds. For the calcium phosphate stone, at 0° and 10° of incline, the stone reached 10cm after 6.9 seconds and 42.8 seconds respectively (p<0.05). At 20° and 40°, the calcium phosphate stone moved a mean maximum distance of 2.4cm and 1cm, and the trial was stopped after 60 seconds. Alterations in the angle of inclination reduced stone retropulsion during ureteroscopic lithotripsy in an in vitro model to <1cm. Finally, increasing the incline angle of a patient may effectively preclude retropulsion when performing laser lithotripsy of ureteral stones.

60 APPLIED LIFE SCIENCES↗

Renal Stone Risk During Space Flight: Assessment and Countermeasure Validation

NASA has focused its future on exploration class missions including the goal of returning to the moon and landing on Mars. With these objectives, humans will experience an extended exposure to the harsh environment of microgravity and the associated negative effects on all the physiological systems of the body. Exposure to microgravity affects human physiology and results in changes to the urinary chemical composition during and after space flight. These changes are associated with an increased risk of renal stone formation. The development of a renal stone would have health consequences for the crewmember and negatively impact the success of the mission. As of January 2007, 15 known symptomatic medical events consistent with urinary calculi have been experienced by 13 U.S. astronauts and Russian cosmonauts. Previous results from both MIR and Shuttle missions have demonstrated an increased risk for renal stone formation. These data have shown decreased urine volume, urinary pH and citrate levels and increased urinary calcium. Citrate, an important urinary inhibitor of calcium-containing renal stones binds with calcium in the urine, thereby reducing the amount of calcium available to form calcium oxalate stones. Urinary citrate also prevents calcium oxalate crystals from aggregating into larger crystals and into renal stones. In addition, citrate makes the urine less acidic which inhibits the development of uric acid stones. Potassium citrate supplementation has been successfully used to treat patients who have formed renal stones. The evaluation of potassium citrate as a countermeasure has been performed during the ISS Expeditions 3-6, 8, 11-13 and is currently in progress during the ISS Expedition 14 mission. Together with the assessment of stone risk and the evaluation of a countermeasure, this investigation provides an educational opportunity to all crewmembers. Individual urinary biochemical profiles are generated and the risk of stone formation is estimated. Increasing fluid intake is recommended to all crewmembers. These results can be used to lower the risk for stone formation through lifestyle, diet changes or therapeutic administration to minimize the risk for stone development. With human presence in microgravity a continuing presence and exploration class missions being planned, maintaining the health and welfare of all crewmembers is critical to the exploration of space.

Whitson, P. A.↗

The role of contrast-enhanced computed tomography to detect renal stones

Purpose: To investigate the detectability of renal stones in corticomedullary and nephrographic phases on contrast-enhanced computed tomography (CT). Methods: All consecutive patients between January 2012 and February 2016 undergoing CT of the kidneys according to our department’s standard four-phase protocol and having at least one stone in the NC-phase (NCP) were included. Fifty patients with altogether 136 stones were eligible. Two radiologists in consensus evaluated the NCP from each examination and documented the number, location, and size of stones. Three abdominal radiologists blinded to the findings of the NCP reviewed independently the corticomedullary and nephrographic phases on two different occasions. They reported the number and location of stones in each kidney. For the inter-observer agreement the intra-class correlation coefficient (ICC) was estimated. The detection rate of renal stones was calculated for the three radiologists and compared between the two contrast-enhanced phases and the results were analyzed with concern to the size of the stones. Results: The ICC was 0.86. There was no statistically significant difference between corticomedullary and nephrographic phases (p = 0.94). The detection rate for stones measuring 3–5 mm was 82–88% and 98% for stones ≥ 6 mm. Conclusion: The detectability of renal stones ≥ 6 mm on contrast-enhanced CT is extremely high. This means that stones with a higher risk of not passing spontaneously can be safely diagnosed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-IeP2-15: Virtual Insertion of Digital Kidney Stones Into Dual-Source, Dual- Energy CT Projection Data

Purpose: In order to investigate novel methods to more accurately estimate the mineral composition of kidney stones using dual energy CT, it is desirable to be able to combine digital stones of known composition with actual phantom and patient scan data. In this work, we developed and validated a method to insert digital kidney stones into projection data acquired on a dual-source, dual-energy CT system. Methods: Attenuation properties of stones of different mineral composition were computed using tabulated mass attenuation coefficients, the chemical formula for each stone type, and the effective beam energy at each evaluated tube potential. A previously developed method to insert lesions into x-ray CT projection data was extended to include simultaneous dual-energy CT projections acquired on a dual-source gantry (Siemens Somatom Flash). Digital stones were forward projected onto both detectors and the resulting projections added to the physically acquired sinogram data. To validate the accuracy of the technique, digital stones were inserted into different locations in the ACR CT accreditation phantom; low and high contrast resolution, CT number accuracy and noise properties were compared before and after stone insertion. The procedure was repeated for two dual-energy tube potential pairs in clinical use on the scanner, 80/Sn140 kV and 100/Sn140 kV, respectively. Results: The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner. The largest average CT number difference for the 4 insert in the CT number accuracy module of the phantom was 3 HU. Conclusion: A framework was developed and validated for the creation of digital kidney stones of known mineral composition, and their projection-domain insertion into commercial dual-source, dual-energy CT projection data. This will allow a systematic investigation of the impact of scan and reconstruction parameters on stone attenuation and dual-energy behavior under rigorously controlled conditions. Dr. McCollough receives research support from Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗