Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STABLE BEAMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Four-harmonic buncher for radioactive and stable beams switching at the ATLAS facility [Four-harmonic buncher for radioactive and stable beams combination at the ATLAS facility]

Here, the Argonne Tandem Linac Accelerator System (ATLAS) is planning an upgrade to a multi-user facility to simultaneously accelerate both stable beams from an ECR ion source and radioactive beams from an Electron Beam Ion Source charge breeder. The ATLAS Multi-User Upgrade will need to provide high transmission of ion beams with a mass-to-charge ratio up to 7 as it enables more options to alternate radioactive and stable beams. Currently, the bunching is provided with a lumped circuit multi-harmonic buncher, which cannot effectively operate at the required amplitude of the saw-tooth voltage for ions with mass-to-charge ratio of 7 due to thermal issues. RadiaBeam Systems in collaboration with Argonne National Laboratory has designed a four-harmonic coaxial resonator buncher with the ATLAS fundamental frequency of 12.125 MHz, and a compact, less than 2-m-long, footprint, capable of providing the required voltage of 6.2 kV. This device allows fast and reliable pre-bunching of DC ion beams with the capability of fast switching of heavy-ion radioactive and stable beams for delivery to multiple users. In this paper, we will discuss the RF and engineering design considerations of this buncher.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The super separator spectrometer (S{sup 3}) for SPIRAL2 stable beams.

S{sup 3} (Super Separator Spectrometer) is a device designed for experiments with the very high intensity stable beams of LINAG, the superconducting linear accelerator of GANIL, which will be built in the framework of SPIRAL2. These beams can reach intensities exceeding 100p{mu}A for lighter ions. These unprecedented intensities open new opportunities in several physics domains, e.g. super-heavy and very-heavy element properties, spectroscopy at and beyond the dripline, isomer and ground state properties, and the products of multi-nucleon transfer and deep-inelastic reactions. An international collaboration has been formed for proposing physics experiments and developing technical solutions for this new instrument. We present here the optical layout of the spectrometer and the studies of its multipole magnets.

43 PARTICLE ACCELERATORS↗

S{sup 3}: The Super Separator Spectrometer for SPIRAL2 stable beams

S{sup 3}(Super Separator Spectrometer) is a device designed for experiments with the very high intensity stable beams of LINAG, the superconducting linear accelerator of GANIL, which will be built in the framework of SPIRAL2. These beams, which will provide ions with A/Q = 3 in SPIRAL2 phase one, can reach intensities up to 1mA for light ions, A<50. These unprecedented intensities open new opportunities in several physics domains, e.g. super-heavy and very-heavy nuclei, spectroscopy at and beyond the drip line, isomers and ground state properties, multi-nucleon transfer and deep-inelastic reactions. An international collaboration has been formed to propose physics experiments and develop technical solutions for this new instrument.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing MeV photon dose generation in laser-solid interactions via stable beam propagation

Bremsstrahlung MeV x rays with high doses are essential for radiography of dense objects. Intense, short-pulse laser-driven MeV x-ray sources offer a promising solution, but understanding how the dose scales with laser intensity is crucial for their development. While theory predicts a square root scaling with laser intensity, experimental verification has been hindered by significant shot-to-shot variations, often exacerbated by long preplasma scale lengths from low laser contrast. Here, we demonstrate low shot-to-shot dose variation and confirm the theoretical scaling using high-contrast OMEGA EP laser interactions with millimeter-thick tantalum foils, achieving MeV x-ray doses up to 5.4 rad at 1 m for E photon > 500 keV. Simulations reveal that the unique focal spot of the OMEGA EP laser enables efficient x-ray generation and reduced variability by facilitating deeper laser penetration into dense plasma, even with shorter preplasma scale lengths. Published by the American Physical Society 2025

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of laser-target parameters for the production of stable lithium beam

A laser ion source coupled with a radio frequency quadrupole linac accelerator is being proposed as a suitable system for the production of a low energy, high-current stable lithium beam. In order to maximize the lithium yield, plasmas generated by laser ablation of different materials based on lithium (Li, LiOH, and LiNbO3) have been characterized by using a Faraday cup and an electrostatic ion analyzer in the time of flight configuration. A wide range of laser power density has been investigated (109–1012 W/cm2) using two Nd:YAG lasers operating at different wavelengths (1064 nm and 532 nm), pulse durations (6 ns and 17 ns), and maximum energies (1400 mJ and 210 mJ). This paper outlines the pros and cons of the investigated materials by studying how the ion energy, yields, and charge state distributions are modified when the laser power density is changed. Considerable attention has been paid to the higher charge states of oxygen, which may occur with the same mass-to-charge ratio of Li3+. The analysis has evidenced that LiNbO3 represents a valid target since it allows minimizing the O6+/7Li3+ ratio down to 2.5% by using a laser power density of 1.8 × 1010 W/cm2. For such a condition, a Li3+ current of 1.4 mA/cm2 has been measured.

Cannavò, A. (ORCID:0000000309759630)↗

Stable electron beam propagation in a plasma column

The stability of plasma-based accelerators against transverse misalignments and asymmetries of the drive beam is crucial for their applicability. Without stabilizing mechanisms, even small initial offsets of the drive beam centroid can couple coherently to the plasma wake, grow, and ultimately lead to emittance degradation or beam loss for a trailing witness beam. In this work, we demonstrate the intrinsic stability of a beam propagating in a plasma column. This result is relevant in the context of plasma-based positron acceleration, where a wakefield suitable for the transport and acceleration of a positron witness beam is generated in a plasma column by means of an electron drive beam. The stable propagation of the drive beam is a necessary condition for the experimental implementation of this scheme. The differences and similarities of stabilizing mechanisms in a plasma column compared to a homogeneous plasma are identified via theory and particle-in-cell simulations. Experimental tolerances are given, demonstrating the experimental feasibility of the scheme.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A stable partitioned FSI algorithm for incompressible flow and deforming beams

An added-mass partitioned (AMP) algorithm is described for solving fluid–structure interaction (FSI) problems coupling incompressible flows with thin elastic structures undergoing finite deformations. The new AMP scheme is fully second-order accurate and stable, without sub-time-step iterations, even for very light structures when added-mass effects are strong. The fluid, governed by the incompressible Navier–Stokes equations, is solved in velocity-pressure form using a fractional-step method; large deformations are treated with a mixed Eulerian-Lagrangian approach on deforming composite grids. The motion of the thin structure is governed by a generalized Euler–Bernoulli beam model, and these equations are solved in a Lagrangian frame using two approaches, one based on finite differences and the other on finite elements. The key AMP interface condition is a generalized Robin (mixed) condition on the fluid pressure. This condition, which is derived at a continuous level, has no adjustable parameters and is applied at the discrete level to couple the partitioned domain solvers. Special treatment of the AMP condition is required to couple the finite-element beam solver with the finite-difference-based fluid solver, and two coupling approaches are described. A normal-mode stability analysis is performed for a linearized model problem involving a beam separating two fluid domains, and it is shown that the AMP scheme is stable independent of the ratio of the mass of the fluid to that of the structure. A traditional partitioned (TP) scheme using a Dirichlet–Neumann coupling for the same model problem is shown to be unconditionally unstable if the added mass of the fluid is too large. A series of benchmark problems of increasing complexity are considered to illustrate the behavior of the AMP algorithm, and to compare the behavior with that of the TP scheme. The results of all these benchmark problems verify the stability and accuracy of the AMP scheme. Results for one benchmark problem modeling blood flow in a deforming artery are also compared with corresponding results available in the literature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Production of C-14 and Stable Ion Beams at the Argonne Tandem Linac Accelerator System with the ECR3 Ion Source

The Argonne Tandem Linac Accelerator System (ATLAS) at Argonne National Laboratory (ANL) paused production of carbon-14 ion beams with the removal of the Tandem Van de Graaff in 2013. Installation of ECR3, an Electron Cyclotron Resonance Ion Source, returned that production capability to ATLAS, with the first C-14 beam delivered in December 2020. Information is presented on C-14 beam current, gas consumption and N-14 filtering techniques using stripping foils at different sections of ATLAS. ECR3 also fulfilled the operational goal of adding flexibility to ATLAS stable beam production capabilities. Beneficial impacts to ATLAS operation, beam development and experimental programs are discussed.

Scott, R. H.↗

Final Technical Report for Award DE-FG02-98ER41080

The prime motivation of the project at McMaster University was to carry out the critical evaluation and compilation of Nuclear Structure and Decay data, and of nuclear astrophysics data with continued participation in the United States Nuclear Data Program (US-NDP). A large body of evaluated and compiled structure data were supplied for databases such as ENSDF, XUNDL, NSR, etc. residing on webpage of National Nuclear Data Center of the Brookhaven National Laboratory, Upton, New York, USA. Thermonuclear reaction rates of importance to stellar explosions, such as novae, x-ray bursts and supernovae, were evaluated as well. This effort was closely coupled to our ongoing experimental effort, which took advantage of radioactive ion beam and stable beam facilities worldwide to study these key reaction rates. This report contains brief descriptions of the various activities together with references to all the publications in peer-reviewed journals which were the result of work carried out with the award DE-FG02-98-ER41080, during 1998-2013.

Chen, Alan↗

Evaluation of Laser Stabilization and Imaging Systems for LCLS-II

By combining the top performing commercial laser beam stabilization system with the most ideal optical imaging configuration, the beamline for the Linear Accelerator Coherent Light Source II (LCLS-II) will deliver the highest quality and most stable beam to the cathode. To determine the optimal combination, LCLS-II beamline conditions were replicated and the systems tested with a He-Ne laser. The Guidestar-II and MRC active laser beam stabilization systems were evaluated for their ideal positioning and stability. Both a two and four lens optical imaging configuration was then evaluated for beam imaging quality, magnification properties, and natural stability. In their best performances when tested over fifteen hours, Guidestar-II kept the beam stable over ~ 70-110um while the MRC system kept it stable over ~ 90- 100um. During short periods of time, Guidestar-II kept the beam stable between 10-20um, but was more susceptible to drift over time, while the MRC system maintained the beam between 30-50um with less overall drift. The best optical imaging configuration proved to be a four lens system that images to the iris located in the cathode room and from there, imaged to the cathode. The magnification from the iris to the cathode was 2:1, within an acceptable tolerance to the expected 2.1:1 magnification. The two lens configuration was slightly more stable in small periods of time (<10 minutes) without the assistance of a stability system, ~ 55um compared to ~ 70um, but the four lens configuration’s beam image had a significantly flatter intensity distribution compared to the two lens configuration which had a Gaussian distribution. A final test still needs to be run with both stability systems running at the same time through the four lens system. With this data, the optimal laser beam stabilization system can be determined for the beamline of LCLS-II.

43 PARTICLE ACCELERATORS↗

Evaluation of Laser Stabilization and Imaging Systems for LCLS-II (Final Paper)

By combining the top performing commercial laser beam stabilization system with the most ideal optical imaging configuration, the beamline for the Linear Accelerator Coherent Light Source II (LCLS-II) will deliver the highest quality and most stable beam to the cathode. To determine the optimal combination, LCLS-II beamline conditions were replicated and the systems tested with a He-Ne laser. The Guidestar-II and MRC active laser beam stabilization systems were evaluated for their ideal positioning and stability. Both a two and four lens optical imaging configuration was then evaluated for beam imaging quality, magnification properties, and natural stability. In their best performances when tested over fifteen hours, Guidestar-II kept the beam stable over approximately 70-110um while the MRC system kept it stable over approximately 90-100um. During short periods of time, Guidestar-II kept the beam stable between 10-20um, but was more susceptible to drift over time, while the MRC system maintained the beam between 30-50um with less overall drift. The best optical imaging configuration proved to be a four lens system that images to the iris located in the cathode room and from there, imaged to the cathode. The magnification from the iris to the cathode was 2:1, within an acceptable tolerance to the expected 2.1:1 magnification. The two lens configuration was slightly more stable in small periods of time (less than 10 minutes) without the assistance of a stability system, approximately 55um compared to approximately 70um, but the four lens configurations beam image had a significantly flatter intensity distribution compared to the two lens configuration which had a Gaussian distribution. A final test still needs to be run with both stability systems running at the same time through the four lens system. With this data, the optimal laser beam stabilization system can be determined for the beamline of LCLS-II.

43 PARTICLE ACCELERATORS↗

High Efficiency Uniform Wakefield Acceleration of a Positron Beam Using Stable Asymmetric Mode in a Hollow Channel Plasma

Plasma wakefield acceleration in the blowout regime is particularly promising for high-energy acceleration of electron beams because of its potential to simultaneously provide large acceleration gradients and high energy transfer efficiency while maintaining excellent beam quality. However, no equivalent regime for positron acceleration in plasma wakes has been discovered to date. We show that after a short propagation distance, an asymmetric electron beam drives a stable wakefield in a hollow plasma channel that can be both accelerating and focusing for a positron beam. A high charge positron bunch placed at a suitable distance behind the drive bunch can beam-load or flatten the longitudinal wakefield and enhance the transverse focusing force, leading to high efficiency and narrow energy spread acceleration of the positrons. Three-dimensional quasistatic particle-in-cell simulations show that an over 30% energy extraction efficiency from the wake to the positrons and a 1% level energy spread can be simultaneously obtained. Further optimization is feasible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oak Ridge 25URC Tandem Accelerator 2008 SNEAP Lab Report

During FY 2008, the 25URC operated for slightly over 3,000 research hours. The radioactive species {sup 80}Ge and {sup 17,18}F accounted for 763 of these hours. This included an experiment using {sup 17}F which was only possible due to an improvement of a factor of 50 in beam intensity over our previous facility record. Twenty stable beam species were provided this year. Operation for the experimental program was at terminal potentials from 2.02 to 23.8 MV. Approximately 200 hours of conditioning were done to return the machine to operation after tank openings. There were six tank openings during the year: three scheduled for general maintenance and three unscheduled. Two of the unscheduled openings were required to correct shorting rod issues and the other was to reestablish communication with one of the major dead sections. On July 28, an event happened that caused all accelerators at the Holifield Radioactive Ion Beam Facility (HRIBF) to suspend operation. At approximately 8 AM on that Monday, during operations with approximately 12 {micro}A of 50-MeV protons on a uranium carbide target, delivering neutron-rich {sup 81}Zn beam to the new Low-energy Radioactive Ion Beam Spectroscopy Station (LeRIBSS), a radiological control technician (RCT) reported higher than normal radiation levels just outside the shield door to the IRIS1 vault (the room in which RIBs are produced at HRIBF). The measured dose rate equivalent was 4 mrem/hr. The presence of radiological contamination on the floor just outside the shield door was subsequently noted, as was the possible presence of airborne radioactivity. These observations were reported to facility management. Accelerators were put in standby immediately and the building evacuated. The event was subsequently declared a laboratory operational emergency. Parts of the building were cleared for reentry to collect belongings on Monday afternoon. The entire building was cleared for reoccupation on Tuesday morning after a detailed radiological survey found no contamination outside the shielded vaults. No decontamination was required. No individual received any detectable radiological dose as a result of this event. The 25URC tandem accelerator was given permission to resume operation with stable beams in early September, but radioactive ion production is still not allowed. Subsequent analysis indicated a release that consisted entirely of noble gasses (Xe and Kr isotopes). We believe we have identified two unrelated failures, one associated with the HVAC system and the other with the roughing system exhaust which accounts for both the escape of noble gasses into the IRIS1 vault and their migration outside the vault. An investigation team report is expected by October 24. At that time, corrective actions will be determined and the path to future radioactive ion beam production will be known. The break from operations allowed a few upgrades to be implemented. The most notable was the installation and commissioning of a SNICS ion source purchased from National Electrostatics Corporation (NEC). The SNICS replaced the old Alton/Aarhus source that we have used for many years. An ANU style gas cathode holder was purchased also but has not yet been implemented. The first beams have been produced by the source and the biggest problem encountered was reducing the beam for very low current experiments. A new power supply for the injection magnet was installed during this period also. Radioactive ion beam (RIB) development at the High Power Target Laboratory (HPTL) has been delayed this year while installing the platforms, conduits and equipment for the second Injector for Radioactive Ion Species (IRIS2) which is co-located with the HPTL facility. Therefore, the majority of development activities have been performed at the two off-line ion source test facilities (ISTF1 and ISTF2) and the On-Line Test Facility (OLTF). Both test facilities have been developing systems which will eventually be used with IRIS2. Two new tunable Ti:Sapphire lasers have been ordered for continuing development of an ion source based on laser ionization using all solid-state lasers. When these are delivered, we will have a complete laser system. The other ion source test facility is continuing development of a negative-ion cooler for beam purification using photodetachment. This process has been demonstrated to work well in three systems so far (removing Co from Ni, removing S from Cl, and removing O from F). The original ion cooler has been modified to allow for use on the IRIS2 platform. Testing of this modified device is starting now. The OLTF has been used to test new types of uranium carbide targets for the electron beam plasma source (which are used for neutron-rich RIB campaigns) and to test a novel ion source which may result in purified beams of radioactive strontium isotopes.

43 PARTICLE ACCELERATORS↗

Wide field array calibration dependence on the stability of measured dose distributions

Purpose: The aim of this work was to simulate the effect of dose distribution changes on detector array calibrations and to explore compensatory methods that are used during calibration measurements. Methods: The array calibration technique that was investigated is known as wide field (WF) calibration. Using this method, a linear array [y-axis (65 detectors) of the IC PROFILER (Sun Nuclear Corporation, Melbourne, FL)] is calibrated with three measurements ({alpha}, {theta}, and {lambda}); each measurement uses the same radiation field, which is larger than the array. For measurement configuration {theta}, the array is rotated by 180 deg. from its position in {alpha}; for {lambda}, the array is shifted by one detector from its position in {theta}. The relative detector sensitivities are then determined through ratios of detector readings at the same field locations (using {theta} and {lambda}). This method results in error propagation that is proportional to the number of detectors in the array. During the procedure, the calibration protocol operates under three postulates, which state that (a) the beam shape does not change between measurements; (b) the relative sensitivities of the detectors do not change; and (c) the scatter to the array does not change as the array is moved. The WF calibration's sensitivity to a postulate (a) violation was quantified by applying a sine shaped perturbation (of up to 0.1%) to {alpha}, {theta}, or {lambda}, and then determining the change relative to a baseline calibration. Postulate (a) violations were minimized by using a continuous beam and mechanized array movement during {theta} and {lambda}. A continuously on beam demonstrated more stable beam symmetry as compared to cycling the beam on and off between measurements. Additional side-scatter was also used to satisfy postulate (c). Results: Simulated symmetry perturbations of 0.1% to {theta} or {lambda} resulted in calibration errors of up to 2%; {alpha} was relatively immune to perturbation (<0.1% error). Wide field calibration error on a linear accelerator with similar symmetry variations was {+-}1.6%. Using a continuous beam during {theta} and {lambda} with additional side-scatter reduced the calibration error from {+-}1.6% to {+-}0.48%. Conclusions: This work increased the reproducibility of WF calibrations by limiting the effect of measurement perturbations primarily due to linear accelerator symmetry variations. The same technique would work for any array using WF calibration.

60 APPLIED LIFE SCIENCES↗

Laboratory Studies in UV and EUV Solar Physics

The Ion Beam Experiment at the Center for Astrophysics is dedicated to the study of ion-electron collision processes of importance in solar physics. A paper describing our most recent measurement 'Absolute cross section for Si(2+)(3s3p(sup 3)Rho (sup 0) yields 3s3p(sup 1)Rho(sup 0)) electron-impact excitation' was published during the past year. Dr. Paul Janzen received his PhD. from the Harvard Physics Department on the basis of this and other work, such as the new electron cyclotron resonance (ECR) ion source. The ion source is producing stable beams with large currents for our present work on C(2+), and it also produces stable beams with large currents of more highly charged systems, for future work on systems such as O(4+). The past year has been focussed on our current program to measure absolute cross sections for Electron Impact Excitation (EIE) in C(2+), one of the primary ions used for probing the solar transition region. C(2+) beams produced by the ion source have been transported to the interaction region of the experiment, where the collisions are studied, and Visiting Scientist Dr. Adrian Daw is currently collecting data to measure the C(2+)(2s2p(sup 3)Rho(sup 0) yields 2p(sup 2)(sup 3)Rho) EIE cross section as a function of collision energy, under the guidance of Drs. John Kohl, Larry Gardner and Bill Parkinson. Also this year, modifications were made to the ECR ion source in order to produce greater currents of highly charged ions. Testing of the ion source was completed. Modifications were designed to extend the photon detection capabilities of the apparatus to shorter UV wavelengths, or EUV. Following the work on C(2+)(2s2p(sup 3)Pho(sup 0) yields 2p(sup 2)(sup 3)Rho), the extended UV detection capabilities will be used to measure the C(2+)(2s(sup 2)(sup 1)S yields 2s2p(sup 1)Rho(sup 0)) EIE cross section. The EUV modifications complement those of the new ion source, by enabling detection of EUV light generated by high charge state ions and putting us in a position to measure the excitation cross sections for more highly charged ions as well.

Parkinson, William↗

ANALYSIS OF NSLS-II TOUSCHEK LIFETIME

As scrapers are adopted for the loss control of NSLS-II storage ring, Touschek lifetime estimations for various cases are required to assure the stable operation. However, to estimate the Touschek lifetime, momentum apertures should be measured all along the ring and, if we want to estimate the lifetime in various situations, it can take extremely long time. Thus, rather than simulating for each case, a semi-analytic methods with the interpolations are used for the measurements of the momentum apertures. In this paper, we described the methods and showed the results. Having enough Touschek lifetime is important for synchrotron light source for the users to perform experiments with stable beams. In NSLS-II, the scrapers will be installed for the loss control. Especially, the horizontal scrapers will be installed where the dispersions are maximum. Therefore, we need to find the proper scraper gap values which do not reduce the lifetime too much for the stable beam operation. To estimate reliable Touschek lifetime, we should measure the momentum apertures at many positions along the ring. For the rough estimation of the Touschek lifetime, the RF momentum acceptance can be used and for a more detailed estimation, the linear approximation of synchrotron oscillation can be used. However, for the strong focussing synchrotrons, like NSLS-II, the linear approximation is not enough to obtain the reliable momentum apertures, and, in general, particle tracking simulations are used. However, for NSLS-II case, we need to track the particle about 400 turns at each point to make it a full synchrotron oscillation period and to obtain the reliable Touschek lifetime we need measure the momentum apertures at several hundred positions at least. Therefore, it can take quite a long time if we want to have the reasonable resolution for the measurements. Furthermore, at the simulation, if we want to measure the aperture inside a element, we should divide the element and this will make the simulation longer. Here, we developed a systematic method to calculate the momentum aperture using interpolation tables. Once the tables are prepared, the precise momentum aperture can be calculated instantly at arbitrary position for various situations.

43 PARTICLE ACCELERATORS↗