Engineering PapersSearch

SEARCH · Engineering Papers

Results for “SQUID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A SQUID readout system for a superconducting gyroscope

A design of a read out system for a superconducting gyroscope to be used in an orbiting gyroscope relativity experiment is discussed. The 'London Moment' of the superconducting rotor, which lies along the spin axis of the rotor, will be measured with a SQUID-type magnetometer. The SQUID will be built around the gyro rotor, with a very close spacing to give an inductance between 10 millionths and 1 millionth Hy. A SQUID of this design should resolve 2.07 times 10 to the minus 19th weber. The angular resolution of the gyroscope will then be 0.0035 arc-second, which is sufficient for the intended experiment.

Hendricks, J. B.

Signal detection in l/f noise of SQUID magnetometers

It is shown that the variance on the SQUID power spectrum in the l/f low frequency region is well behaved, i.e., any small frequency band may be treated as white noise in standard power spectrum estimation theory. Specifically a calibration signal is examined at 0.017 Hz with an equivalent energy referred to the SQUID input coil of 1 times 10 to the -30th J and a digitally recorded and analyzed record of 140 hr duration obtained an optimum S/N better than 400. The results are in good agreement with theory. In addition no deviation from the l/f dependence of the noise energy spectrum is seen down to frequencies below 10 to the -5th Hz. A commercially available SQUID and electronics system were used.

Cabrera, B.

Induced electric currents in the Alaska oil pipeline measured by gradient, fluxgate, and SQUID magnetometers

The field gradient method for observing the electric currents in the Alaska pipeline provided consistent values for both the fluxgate and SQUID method of observation. These currents were linearly related to the regularly measured electric and magnetic field changes. Determinations of pipeline current were consistent with values obtained by a direct connection, current shunt technique at a pipeline site about 9.6 km away. The gradient method has the distinct advantage of portability and buried- pipe capability. Field gradients due to the pipe magnetization, geological features, or ionospheric source currents do not seem to contribute a measurable error to such pipe current determination. The SQUID gradiometer is inherently sensitive enough to detect very small currents in a linear conductor at 10 meters, or conversely, to detect small currents of one amphere or more at relatively great distances. It is fairly straightforward to achieve imbalance less than one part in ten thousand, and with extreme care, one part in one million or better.

Campbell, W. H.

Effect of low-frequency ambient magnetic fields on the control unit and RF head of a commercial SQUID magnetometer

The control unit and RF head of the SHE model 330XRFSQUID system are shown to be sensitive to ambient ac magnetic fields below 1 HZ, which cause the appearance of false signals corresponding to a magnetometer signal of 0.000001 phi(0) per gauss of field applied. The control unit shows a sensitivity that is linear with frequency, suggesting that the signal is generated by Faraday induction. In contrast, the RF head response is independent of frequency and shows a strong second-harmonic coversion. This response may be due to the magnetic field sensitivity of the ferrite core inductor in the tuned amplifier of the RF head. These signals induced by ambient fields are a potential source of error in Stanford's Relativity Gyroscope experiment, which uses SQUID's on board a rolling satellite as part of the gyroscope readout system. The extent of the magnetic field sensitivity in these components necessitates the use of additional magnetic shielding aboard the satellite.

Marcus, C. M.

Space applications of superconductivity - Low frequency superconducting sensors

Although this paper deals with several low-frequency instruments and devices, most of the discussion relates to SQUID (Superconducting QUantum Interference Device) magnetometers and gradiometers, since these are perceived as the instruments with the greatest potential for space applications. The discussion covers SQUID for magnetic field measurements; present state of the art of SQUID technology; ultimate potential performance; applications to magnetic measurements in space; SQUID galvanometers, voltage and current sensors, and wide-band amplifiers; magnetic shielding, and superconducting dc transformer. SQUIDS are superior to all other magnetic sensors in sensitivity, frequency response, range, and linearity. It is suggested that SQUID instruments, both magnetometers and gradiometers, would be valuable in studies of the dynamics of interplanetary and planetary fields. SQUID gradiometers are useful for detection and mapping of magnetic anomalies at short to moderate ranges.

Zimmerman, J. E.

A high accuracy all-angle gyroscope readout using quantized flux

Means are described to use SQUID magnetometer flux counting and the London moment of a spherical superconducting gyroscope to read out the gyroscope spin axis direction to an accuracy of at least 23 bits per quadrant. The system is discussed in analogy to optical fringe counting as applied to distance measurement. Several methods of applying both analog and digital SQUID magnetometers to the readout problem are given, as well as limitations on each. Described are two methods of increasing the flux available for measurement: magnetizing the gyroscope with a trapped field, and optimizing readout circuit inductances. Finally, the same principle on which the gyroscope readout is based is applied to a description of a high accuracy, flux counting, digital angle encoder.

Anderson, J. T.

Biomagnetic instrumentation and measurement

The instruments and techniques of biomagnetic measurement have progressed greatly in the past 15 years and are now of a quality appropriate to clinical applications. The paper reports on recent developments in the design and application of SQUID (Superconducting Quantum Interference Device) magnetometers to biomagnetic measurement. The discussion covers biomagnetic field levels, magnetocardiography, magnetic susceptibility plethysmography, ambient noise and sensor types, principles of operation of a SQUID magnetometer, and laboratory techniques. Of the many promising applications of noninvasive biomagnetic measurement, magnetocardiography is the most advanced and the most likely to find clinical application in the near future.

Iufer, E. J.

The biology of cartilage. II

Squid head cartilage properties in terms of light and electron microscopic appearance, amino acid composition and X ray diffraction

Person, P.

The effect of membrane parameters on the properties of the nerve impulse.

The effect of varying some membrane parameters is explored, basing the investigation on computer simulation of the Hodgkin-Huxley equations for the squid giant axon, including variations in the membrane capacitance, conductances, and the rate constants. It is shown that by reducing the degree of regeneration in the excitable membrane, the character of the nerve signal can be smoothly changed from that of the axonal spike to essentially electrotonic spread, with all gradations in between. The reduction in the degree of regeneration can most simply be brought about by a decrease in the density of active membrane patches.

Sabah, N. H.

Improvements of a magnetic monopole detector

Modifications to our previously described detector of magnetic monopoles resulting in substantial improvements in performance have been made. The sensitivity has been increased a factor of 35 by using a sensitive magnetometer (SQUID) to measure changes in current. The modifications, new measurement techniques, and implications for past and future experiments are described.

Eberhard, P. H.

A high accuracy gyroscope readout test facility for the relativity gyroscope experiment

An apparatus is under construction for ground-based testing of a gyroscope system to be used in a satellite test of general relativity. The immediate goal is a readout capable of measuring the direction of the gyroscope spin axis to an angular resolution of one arcsecond over a limited range. A combination of SQUID magnetometers and persistent current loops are used to measure the London moment of the spinning superconducting rotor levitated electrostatically. To obtain a trapped flux signal in the gyroscope sufficiently smaller than the London moment signal, the apparatus makes use of a new magnetic field shielding technique for obtaining large superconductor shielded regions below 0.1 millionth of a Gauss.

Cabrera, B.

Superconducting bearings for application in cryogenic experiments in space

Linear superconducting magnetic bearings suitable for use in a proposed orbital equivalence principle experiment and for general application in space were developed and tested. Current flows in opposite directions in adjacent superconducting wires arranged parallel to the axis of a cylinder. This configuration provides maximum stiffness radially while allowing the test mass to move freely along the cylinder axis. In a space application, the wires are extended to cover the entire perimeter of the cylinder: for the earth-based tests it was desirable to use only the bottom half. Control of the axial position of the test mass is by small control coils which may be positioned inside or outside the main bearing. The design is suitable for application to other geometries where maximum stiffness is desired. A working model scaled to operate in a 1-g environment was perfected approximate solutions for the bearings were developed. A superconducting transformer method of charging the magnets for the bearing, and a position detector based on a SQUID magnetometer and associated superconducting circuit were also investigated.

Everitt, C. W. F.

Development of a London moment readout for a superconducting gyroscope

A gyroscope for verifying certain predictions of General Relativity is under development at Stanford. A method of measuring the gyroscope orientation based on the use of the London moment and a SQUID magnetometer is described. It is estimated that the required sensitivity of 1 milliarc-sec can be achieved in a bandwidth of 2.5 times 10 to the -6th Hz.

Anderson, J. T.

The design and evaluation of superconducting connectors

The development of a superconducting connector for superconducting circuits on space flights is described. It is proposed that such connectors be used between the superconducting readout loop and the SQUID magnetometer in the Gravity Probe B experiment. Two types of connectors were developed. One type employs gold plated niobium wires making pressure connections to gold plated niobium pads. Lead-plated beryllium-copper spring contacts can replace the niobium wires. The other type is a rigid solder or weld connection between the niobium wires and the niobium pads. A description of the methods used to produce these connectors is given and their performance analyzed.

Payne, J. E.

Preliminary Investigation of a Paraglider

A preliminary investigation of the aerodynamic and control characteristics of a flexible glider similar to a parachute in construction has been made at the Langley Research Center to evaluate its capabilities as a reentry glider. Preliminary weight estimates of the proposed vehicle indicate that such a structure can be made with extremely low wing loading. Maximum temperatures during the reentry maneuver might be held as low as about 1,500 F. The results of wind-tunnel and free-glide tests show that the glider when constructed of nonporous material performed extremely well at subsonic speeds and could be flown at angles of attack from about 200 to 900. At supersonic speeds the wing showed none of the unfavorable tendencies exhibited by conventional parachutes at these speeds, such as squidding and breathing. Several methods of packing and deploying the glider have been successfully demonstrated. The results of this study indicate that this flexible-lifting-surface concept may provide a lightweight controllable paraglider for manned space vehicles.

Rogallo, Francis M.