Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPATIAL RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

In Operando Angle‐Resolved Photoemission Spectroscopy with Nanoscale Spatial Resolution: Spatial Mapping of the Electronic Structure of Twisted Bilayer Graphene

To pinpoint the electronic and structural mechanisms that affect intrinsic and extrinsic performance limits of 2D material devices, it is of critical importance to resolve the electronic properties on the mesoscopic length scale of such devices under operating conditions. Herein, angle‐resolved photoemission spectroscopy with nanoscale spatial resolution (nanoARPES) is used to map the quasiparticle electronic structure of a twisted bilayer graphene device. The dispersion and linewidth of the Dirac cones associated with top and bottom graphene layers are determined as a function of spatial position on the device under both static and operating conditions. The analysis reveals that microscopic rotational domains in the two graphene layers establish a range of twist angles from 9.8° to 12.7°. Application of current and electrostatic gating lead to strong electric fields with peak strengths of 0.75 V/μm at the rotational domain boundaries in the device. These proof‐of‐principle results demonstrate the potential of nanoARPES to link mesoscale structural variations with electronic states in operating device conditions and to disentangle such extrinsic factors from the intrinsic quasiparticle dispersion.

Majchrzak, Paulina↗

Predicting High‐Resolution Spatial and Spectral Features in Mass Spectrometry Imaging with Machine Learning and Multimodal Data Fusion

Recent advancements in molecular Mass Spectrometry Imaging have sparked interest in integrating high spatial resolution methods with molecular mass-spectrometry-based chemical imaging. Fusion-based algorithms have proven effective in generating high spatial-resolution molecular mass spectra. However, a significant challenge stems from the differing physical mechanisms underlying image generation and data upsampling techniques, potentially leading to discrepancies in integrated information channels. Integrating physical constraints into data processing workflows is essential to tackle this issue. In this study, we propose an innovative approach that merges data from Fourier transform ion cyclotron resonance (FTICR), time-of-flight matrix-assisted laser desorption/ionization, and time-of-flight secondary ion mass spectrometry imaging techniques. By leveraging FT-ICR's unparalleled spectral resolution and ToF-SIMS's exceptional spatial resolution, we achieve submicron spatial resolution, enabling the observation of intact molecular species with remarkable spectral precision. Canonical correlation analysis is employed to incorporate physical constraints. Through sophisticated image processing and machine learning techniques, the results of this fusion hold significant promise for advancing our comprehension of complex systems and unveiling concealed molecular intricacies.

canonical correlation analysis↗

Evaluating the Value of High Spatial Resolution in National Capacity Expansion Models using ReEDS

Power sector capacity expansion models (CEMs) have a broad range of spatial resolutions. This paper uses the Regional Energy Deployment System (ReEDS) model, a long-term national scale electric sector CEM, to evaluate the value of high spatial resolution for CEMs. ReEDS models the United States with 134 load balancing areas (BAs) and captures the variability in existing generation parameters, future technology costs, performance, and resource availability using very high spatial resolution data, especially for wind and solar modeled at 356 resource regions. In this paper we perform planning studies at three different spatial resolutions--native resolution (134 BAs), state-level, and NERC region level--and evaluate how results change under different levels of spatial aggregation in terms of renewable capacity deployment and location, associated transmission builds, and system costs. The results are used to ascertain the value of high geographically resolved models in terms of their impact on relative competitiveness among renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Spatial Resolution in a High-Fidelity Capacity Expansion Model: An ERCOT Case Study

Capacity expansion models are important tools in examining the evolution of the electric power sector. Embedded in these tools are many modeling choices with consequential impacts on computational burden and associated analysis. In this study, we adjust the spatial resolution of the Regional Energy Deployment System (ReEDS) to understand the implications of higher-fidelity modeling on energy system projections and model solve times. The native ReEDS regions capture the contiguous United States in 134 balancing areas whereas the regions in the higher-resolution version are defined by over 3,000 U.S. counties. Using both resolutions, we conduct a case study of the Texas Interconnection (The Electric Reliability Council of Texas [ERCOT]) to explore differences in model projections and to inform appropriate applications of high spatial resolution in a large-scale, applied capacity expansion model.

county↗

Ambient Tip-Enhanced Photoluminescence with 5 nm Spatial Resolution

We achieve record spatial resolution in ambient tip-enhanced photoluminescence (TEPL) from CdSe/ZnS semiconductor quantum dots (QDs). Our approach only takes advantage of surface roughness at the apex of a sputtered plasmonic gold probe. When irradiated with visible light (633 and 532 nm lasers), nano-corrugated regions of the apex of an Au tip support 5-nm spatial resolution in TEPL imaging of QD aggregates on silicon. The reproducibility of our observations is illustrated using different plasmonic probes and samples. The origin of the observed near-field contrast, underlying the demonstrated high spatial resolution in TEPL, is discussed in the context of field enhancement at the metal tip-fluorophore interface.

Chemical Dynamics Initiative↗

Spatial resolution of a spherical x-ray crystal spectrometer at various magnifications

A high spatial resolution of a few μm is often required for probing small-scale high-energy-density plasmas using high resolution x-ray imaging spectroscopy. This resolution can be achieved by adjusting system magnification to overcome the inherent limitation of the detector pixel size. Laboratory experiments on investigating the relation between spatial resolution and system magnification for a spherical crystal spectrometer are presented. Tungsten Lβ{sub 2} rays from a tungsten-target micro-focus x-ray tube were diffracted by a Ge 440 crystal, which was spherically bent to a radius of 223 mm, and imaged onto an x-ray CCD with 13-μm pixel size. The source-to-crystal (p) and crystal-to-detector (q) distances were varied to produce spatial magnifications (M = q/p) ranging from 2 to 10. The inferred instrumental spatial width reduces with increasing system magnification M. However, the experimental measurement at each M is larger than the theoretical value of pixel size divided by M. Future work will focus on investigating possible broadening mechanisms that limit the spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Downscaled precipitation and mean air temperature datasets; East-Taylor subbasin; 2008-2019; daily temporal resolution; 400 m spatial resolution

This dataset provides gridded meteorological forcing data (specifically, daily precipitation and daily mean air temperature). The dataset has been generated by downscaling the Parameter-elevation Regressions on Independent Slopes Model (PRISM) dataset from a spatial resolution of 800 m to 400 m. The time period is 2008-2019, and the mapped area is East Taylor subbasin in Upper Colorado. The data are in the form of NetCDF files, arranged by year. Compared to the PRISM dataset, the dates of the downscaled dataset are shifted backwards by one (e.g., downscaled data for May 25 corresponds to PRISM data for May 26). This temporal shifting makes the meteorological forcing correspond more closely to the prescribed date. The NetCDF format is a standard raster format that can be read using any Geographic Information System (GIS) software; plenty of modules exist in popular scripting languages (such as Python, R and Matlab) that can also be used to read NetCDF files.East_Taylor_Tavg_PRISM400 corresponds to mean air temperature.East_Taylor_Precip_PRISM400.zip corresponds to precipitation.The proprietary PRISM data (800 m resolution) were purchased with funding from the Watershed Function Scientific Focus Area supported by U.S. Department of Energy, Office of Science, Office of Biological and Environmental Research under award no. DE-AC02-05CH11231.Dataset update on March 9, 2022:Uploaded new data files that are identical to the earlier files but are now in the NetCDF format, arranged by year. Earlier, the files were in the GeoTiff format, arranged by date.

54 ENVIRONMENTAL SCIENCES↗

Advanced Remote-Sensing Imaging Emission Spectrometer (ARIES): AIRS Spectral Resolution with MODIS Spatial Resolution

The Advanced Remote-sensing Imaging Emission Spectrometer (ARIES) will measure a wide range of earth quantities fundamental to the study of global climate change. It will build upon the success of the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Atmospheric Infrared Sounder (AIRS) instruments currently flying on the EOS Aqua Spacecraft. Both instruments are facility instruments for NASA providing data to thousands of scientists investigating land, ocean and atmospheric Earth System processes. ARIES will meet all the requirements of AIRS and MODIS in a single compact instrument, while providing the next-generation capability of improved spatial resolution for AIRS and improved spectral resolution for MODIS.

remote sensing↗

Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40–200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IR-MALDESI Mass Spectrometry Imaging at 50 Micron Spatial Resolution

High spatial resolution in mass spectrometry imaging (MSI) is crucial to understanding the biology dictated by molecular distributions in complex tissue systems. Here, we present MSI using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) at 50 μm resolution. An adjustable iris, beam expander, and an aspherical focusing lens were used to reduce tissue ablation diameters for MSI at high resolution. The laser beam caustic was modeled using laser ablation paper to calculate relevant laser beam characteristics. The minimum laser spot diameter on the tissue was determined using tissue staining and microscopy. Finally, the newly constructed optical system was used to image hen ovarian tissue with and without oversampling, detailing tissue features at 50 μm resolution. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Orientation gradients in relation to grain boundaries at varying strain level and spatial resolution

The resolution dependence of orientation gradients was studied in a well-annealed 99.9995% pure polycrystalline copper pulled to failure in tension. Owing to the well developed neck, different regions in the sample correspond to different tensile strains. Post-mortem characterization was performed using EBSD on cross-sections containing the tensile axis. Kernel average misorientation (KAM) was calculated as a metric to establish correlation between defect accumulation and microstructural features, with a threshold of 5° to focus on intra-granular gradients. The region with the lowest strain (2%) showed high KAM values adjacent to grain boundaries compared to the grain interior, regardless of the point spacing, i.e. the spatial resolution. However, in the region with the highest strain (13%) a strong dependence on resolution was found. For point spacings of 0.5 μm or smaller, the same correlation of high KAM with locations near boundaries was found. At coarse spacings i.e. low spatial resolution, by contrast, the reverse was found in that the highest KAM values appear in the grain interiors, as previously observed in X-ray microscopy on the same sample which had a similar coarse resolution. An analysis of orientation gradients parallel to, and perpendicular to boundaries suggested that the latter tend to be the larger of the two. This helps to explain why boundary-adjacent points have low KAM values. The conclusion is that measurement of local orientation gradient requires a resolution that is comparable to the dislocation substructure.

36 MATERIALS SCIENCE↗

Device for high spatial resolution chemical analysis of a sample and method of high spatial resolution chemical analysis

A system and method for analyzing a chemical composition of a specimen are described. The system can include at least one pin; a sampling device configured to contact a liquid with a specimen on the at least one pin to form a testing solution; and a stepper mechanism configured to move the at least one pin and the sampling device relative to one another. The system can also include an analytical instrument for determining a chemical composition of the specimen from the testing solution. In particular, the systems and methods described herein enable chemical analysis of specimens, such as tissue, to be evaluated in a manner that the spatial-resolution is limited by the size of the pins used to obtain tissue samples, not the size of the sampling device used to solubilize the samples coupled to the pins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited)

We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamic range for the relevant part of the streak record.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗