Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Science with the Solar Optical Telescope (SOT)

Use of the Solar Optical Telescope (SOT) to study the energetics and dynamics of the solar atmosphere is described. Studies include the origin and evolution of the Sun's magnetic field, the structure of solar subsurface convection, the heating of the outer solar atmosphere, and sources of the solar wind in the lower lying regions of the outer atmosphere. To achieve the scientific goals of the SOT, it is necessary to observe features in the solar atmosphere on the scale of a typical photon mean-free-path in continuum radiation and also of the hydrodynamic or density scale-height. The 1.3 m telescope, of a Gregorian configuration, achieves close to 0.1 arcsec angular resolution on the Sun in visible and ultraviolet wavelengths.

Jordan, S. D.↗

Relative Lifetimes of Several Space Liquid Lubricants Using a Vacuum Spiral Orbit Tribometer (SOT)

A vacuum spiral orbit rolling contact tribometer (SOT) was used to determine the relative lifetimes of several unformulated space liquid lubricants. The lubricants tested included a synthetic hydrocarbon (Pennzane 2001 A), three perfluoropolyethers (Krytox 143AC, Fomblin Z25, and Brayco 815Z), three silahydrocarbons (a tri, a tetra, and a penta) and a polyalphaolefin (Nye PAO-100). The SOT simulates the ball motions in an angular contact bearing and tribochemically degrades microgram quantities of lubricant. Test failure is determined when a preset friction coefficient is exceeded. Relative lifetime (orbits/micro-g) is defined as the number of ball orbits to failure divided by the amount of lubricant on the ball. Conditions included 10 to 200 rpm rotational speed, approximately 50 micro-g lubricant, an initial vacuum < 1.3x10(exp -6) Pa, room temperature (approximately 23 C), a mean Hertzian stress of 1.5 GPa, and 440 C stainless steel specimens. Lubricated lifetimes from longest to shortest were Pennzane 2001 A, the silahydrocarbons and the PAO-100, 143AC, ZI-5, and then 815Z. Relative lifetimes compare favorably to full-scale vacuum gimbal bearing tests. The effect of varying the mean Hertzian stress on the lifetime of some of the lubricants was examined.

Jansen, Mark J.↗

SOT: A rapid prototype using TAE windows

The development of the window interface extension feature of the Transportable Applications Executive (TAE) is discussed. This feature is being used to prototype a space station payload interface in order to demonstrate and assess the benefits of using windows on a bit mapped display and also to convey the concept of telescience, the control and operation of space station payloads from remote sites. The prototype version of the TAE with windows operates on a DEC VAXstation 100. This workstation has a high resolution 19 inch bit mapped display, a keyboard and a three-button mouse. The VAXstation 100 is not a stand-alone workstation, but is controlled by software executing on a VAX/8600. A short scenario was developed utilizing the Solar Optical Telescope (SOT) as an example payload. In the scenario the end-user station includes the VAXstation 100 plus an image analysis terminal used to display the CCD images. The layout and use of the prototype elements, i.e., the root menu, payload status window, and target acquisition menu is described.

Stephens, Mark↗

A New Apparatus to Evaluate Lubricants for Space Applications: The Spiral Orbit Tribometer (SOT)

Lubricants used in space mechanisms must be thoroughly tested prior to their selection for critical applications. Traditionally, two types of tests have been used: accelerated and full-scale. Accelerated tests are rapid, economical, and provide useful information for gross screening of candidate lubricants. Although full-scale tests are more believable, because they mimic actual spacecraft conditions, they are expensive and time consuming. The spiral orbit tribometer compromises between the two extremes. It rapidly determines the rate of tribochemically induced lubricant consumption, which leads to finite test times, under realistic rolling/pivoting conditions that occur in angular contact bearings.

Jones, William R., Jr.↗

Outcome analysis of individualized vestibular rehabilitation protocols

OBJECTIVE: To determine the outcome of vestibular rehabilitation protocols in subjects with peripheral vestibular disorders compared with normal and abnormal control subjects. STUDY DESIGN: Prospective study using repeated measure, matched control design. Subjects were solicited consecutively according to these criteria: vestibular disorder subjects who had abnormal results of computerized dynamic posturography (CDP) sensory organization tests (SOTs) 5 and 6 and underwent rehabilitation; vestibular disorder subjects who had abnormal results of SOTs 5 and 6 and did not undergo rehabilitation; and normal subjects (normal SOTs). SETTING: Tertiary neurotology clinic. SUBJECTS: Men and women over age 18 with chronic vestibular disorders and chief complaints of unsteadiness, imbalance, and/or motion intolerance, and normal subjects. INTERVENTIONS: Pre- and post-rehabilitation assessment included CDP, vestibular disability, and activities of daily living questionnaires. Individualized rehabilitation plans were designed and implemented to address the subject's specific complaints and functional deficits. Supervised sessions were held at weekly intervals, and self-administered programs were devised for daily home use. MAIN OUTCOME MEASURES: CDP composite and SOT scores, number of falls on CDP, and self-assessment questionnaire results. RESULTS: Subjects who underwent rehabilitation (Group A) showed statistically significant improvements in SOTs, overall composite score, and reduction in falls compared with abnormal (Group B) control groups. Group A's performances after rehabilitation were not significantly different from those of normal subjects (Group C) in SOTs 3 through 6, and close to normal on SOTs 1 and 2. Subjects in Group A also reported statistically significant symptomatic improvement. CONCLUSIONS: Outcome measures of vestibular protocol physical therapy confirmed objective and subjective improvement in subjects with chronic peripheral vestibular disorders. These findings support results reported by other investigators.

NASA Discipline Neuroscience↗

The Solar Optical Telescope /SOT/

The Solar Optical Telescope (SOT) is a 1-m class, high resolution solar telescope which NASA plans to operate on the Shuttle Spacelab during the mid and late 1980's. SOT will provide resolution down to 0.1 arcsec, and can therefore be used to solve many problems of solar atmosphere structure and dynamics. In particular, SOT should provide definite data on (1) the source of the sun's magnetic field, (2) the amount of power in waves generated in the photosphere, (3) the heating of the chromosphere, and (4) the local and global mass and energy balance in the solar transition region. The SOT Scientific Working Group will help plan, develop, and update the overall scientific plan for the SOT, as well as make recommendations with regard to the SOT project, instrumentation optimization, and scientific data management.

Jordan, S. D.↗

Fine pointing of the Solar Optical Telescope in the Space Shuttle environment

Instruments requiring fine (i.e., sub-arcsecond) pointing, such as the Solar Optical Telescope (SOT), must be equipped with two-stage pointing devices, coarse and fine. Coarse pointing will be performed by a gimbal system, such as the Instrument Pointing System, while the image motion compensation (IMC) will provide fine pointing. This paper describes work performed on the SOT concept design that illustrates IMC as applied to SOT. The SOT control system was modeled in the frequency domain to evaluate performance, stability, and bandwidth requirements. The two requirements of the pointing control, i.e., the 2 arcsecond reproducibility and 0.03 arcsecond rms pointing jitter, can be satisfied by use of IMC at about 20 Hz bandwidth. The need for this high bandwidth is related to Shuttle-induced disturbances that arise primarily from man push-offs and vernier thruster firings. A block diagram of SOT model/stability analysis, schematic illustrations of the SOT pointing system, and a structural model summary are included.

Gowrinathan, S.↗

Vestibular plasticity following orbital spaceflight: recovery from postflight postural instability

Results of previous studies suggested that the vestibular mediated postural instability observed in astronauts upon return to earth from orbital spaceflight may be exacerbated by an increased weighting of visual inputs for spatial orientation and control of movement. This study was performed to better understand the roles of visual and somatosensory contributions to recovery of normal sensori-motor postural control in returning astronauts. Preflight and postflight, 23 astronaut volunteers were presented randomly with three trials of six sensory organization test (SOT) conditions in the EquiTest system test battery. Sagittal plane center-of-gravity (COG) excursions computed from ground reaction forces were significantly higher on landing day than preflight for those test conditions presenting sway-referenced visual and/or somatosensory orientation cues. The ratio of summed peak-to-peak COG sway amplitudes on the two sway-referenced vision tests (SOTs 3 + 6) compared to the two eyes closed tests (SOTs 2 + 5) was increased on landing day, indicating an increased reliance on visual orientation cues for postural control. The ratio of peak-to-peak COG excursions on sway-referenced surfaces (SOTs 4, 5 & 6) to an earth fixed support surfaces (SOTs 1, 2 & 3) increased even more after landing suggesting primary reliance on somatosensory orientation cues for recovery of postflight postural stability. Readaptation to sway-referenced support surfaces took longer than readaptation to sway-referenced vision. The increased reliance on visual and somatosensory inputs disappeared in all astronauts 4-8 days following return to earth.

NASA Program Space Physiology and Countermeasures↗

Head Tilt Posturography to Enhance Balance Control Assessment for Astronauts: A Case Study

For many years, we have used a standard clinical computerized dynamic posturography (CDP) protocol to assess recovery of integrated sensory-motor function in astronauts returning from space flight. The most reliable indications of postflight crew performance capabilities have been obtained from the sensory organization tests (SOTs) within the CDP protocol, particularly SOTs 5 (eyes closed, surface support sway referenced) and 6 (eyes open, surface support and visual surround sway referenced), which are sensitive to changes in availability and/or utilization of vestibular cues. We have observed, however, that some astronauts exhibiting visible signs of incomplete sensory-motor recovery are able to score within clinical norms on standard SOTs 5 and 6 trials, perhaps as a result of cognitive strategies driven by their naturally competitive natures. To improve the sensitivity of the CDP protocol for assessing recovery of integrated sensory-motor function and fitness to return to duties and/or activities of daily living, we have introduced pitch plane head tilt SOT trials to our protocol. In a preliminary study of 5 short duration (~11day missions) astronauts, we showed that they were unable to maintain balance on landing day when performing dynamic head tilt trials, despite scoring within the clinically normal range on the standard SOT trials. The present case report illustrates the advantages of including head tilt trials for assessing sensory-motor recovery in long duration crewmembers.

Hwang, E. Y.↗

Spiral Orbit Tribometer

The spiral orbit tribometer (SOT) bridges the gap between full-scale life testing and typically unrealistic accelerated life testing of ball-bearing lubricants in conjunction with bearing ball and race materials. The SOT operates under realistic conditions and quickly produces results, thereby providing information that can guide the selection of lubricant, ball, and race materials early in a design process. The SOT is based upon a simplified, retainerless thrust bearing comprising one ball between flat races (see figure). The SOT measures lubricant consumption and degradation rates and friction coefficients in boundary lubricated rolling and pivoting contacts. The ball is pressed between the lower and upper races with a controlled force and the lower plate is rotated. The combination of load and rotation causes the ball to move in a nearly circular orbit that is, more precisely, an opening spiral. The spiral s pitch is directly related to the friction coefficient. At the end of the orbit, the ball contacts the guide plate, restoring the orbit to its original radius. The orbit is repeatable throughout the entire test. A force transducer, mounted in-line with the guide plate, measures the force between the ball and the guide plate, which directly relates to the friction coefficient. The SOT, shown in the figure, can operate in under ultra-high vacuum (10(exp -9) Torr) or in a variety of gases at atmospheric pressure. The load force can be adjusted between 45 and 450 N. By varying the load force and ball diameter, mean Hertzian stresses between 0.5 and 5.0 GPa can be obtained. The ball s orbital speed range is between 1 and 100 rpm.

Pepper, Stephen V.↗

Science with the solar optical telescope

The Solar Optical Telescope (SOT) is designed to provide the solar physics community with the data necessary for solving several fundamental problems in the energetics and dynamics of the solar atmosphere. Among these problems are questions on the origin and evolution of the sun's magnetic field, heating of the outer solar atmosphere, and sources of the solar wind in the lower lying regions of the outer atmosphere. The SOT will be built under the management of NASA's Goddard Space Flight Center, with science instruments provided by teams led by Principal Investigators. The telescope will be built by the Perkin-Elmer Corporation, and the science instruments selected for the first flight will be provided by the Lockheed Palo Alto Research Laboratory (LPARL) and the California Institute of Technology, with actual construction of a combined science instrument taking place at the LPARL. The SOT has a 1.3-meter-diameter primary mirror that will be capable of achieving diffraction-limited viewing in the visible of 0.1 arc-second. This dimension is less than a hydrodynamic scale-height or a mean-free-path of a continuum photon in the solar atmosphere. Image stability will be achieved by a control system in the telescope, which moves both the primary and tertiary mirrors in tandem, and will be further enhanced by a correlation tracker in the combined science instrument. The SOT Facility is currently scheduled for its first flight on Spacelab at the beginning of the 1990's.

Jordan, S. D.↗

Stability studies of Solar Optical Telescope dynamics

The Solar Optical Telescope (SOT) is designed to operate as an attached payload mounted on the Instrument Pointing System (IPS) in the cargo bay of the Shuttle Orbiter. Pointing and control of SOT is accomplished by an active Articulated Primary Mirror (APM), an active Tertiary Mirror (TM), an elaborate set of optical sensors, electromechanical actuators and programmable controllers. The structural interactions of this complex control system are significant factors in the stability of the SOT. The preliminary stability study results of the SOT dynamical system are presented. Structural transfer functions obtained from the NASTRAN model of the structure were used. These studies apply to a single degree of freedom (elevation). Fully integrated model studies will be conducted in the future.

Gullapalli, Sarma N.↗

Adaptive Changes In Postural Equilibrium And Motion Sickness Following Repeated Exposures To Virtual Environments

Virtual environments offer unique training opportunities, particularly for training astronauts and preadapting them to the novel sensory conditions of microgravity. Two unresolved human factors issues in virtual reality (VR) systems are: 1) potential "cybersickness", and 2) maladaptive sensorimotor performance following exposure to VR systems. Interestingly, these aftereffects are often quite similar to adaptive sensorimotor responses observed in astronauts during and/or following space flight. Changes in the environmental sensory stimulus conditions and the way we interact with the new stimuli may result in motion sickness, and perceptual, spatial orientation and sensorimotor disturbances. Initial interpretation of novel sensory information may be inappropriate and result in perceptual errors. Active exploratory behavior in a new environment, with resulting feedback and the formation of new associations between sensory inputs and response outputs, promotes appropriate perception and motor control in the new environment. Thus, people adapt to consistent, sustained alterations of sensory input such as those produced by microgravity, unilateral labyrinthectomy and experimentally produced stimulus rearrangements. Adaptation is revealed by aftereffects including perceptual disturbances and sensorimotor control disturbances. The purpose of the current study was to compare disturbances in postural control produced by dome and head-mounted virtual environment displays, and to examine the effects of exposure duration, and repeated exposures to VR systems. Forty-one subjects (21 men, 20 women) participated in the study with an age range of 21-49 years old. One training session was completed in order to achieve stable performance on the posture and VR tasks before participating in the experimental sessions. Three experimental sessions were performed each separated by one day. The subjects performed a navigation and pick and place task in either a dome or head-mounted display (HMD) VR system for either 30 or 60 min. The environment was a square room with 15 pedestals on two opposite walls. The objects appeared on one set of pedestals and the subject s objective was to move the objects to the other set of pedestals. After the subject picked up an object, a pathway appeared and they were required to follow the pathway to the other side of the room. The subject was instructed to perform the task as quickly and accurately as possible, avoiding hitting walls and other any obstacles and placing the object on the center of the pedestal. Postural equilibrium was measured (using the Equitest CDP balance system, Neurocom, International) before, immediately after, and at 1 hr, 2 hr, 4 hr and 6 hr following exposure to VR. Postural equilibrium was measured during quiet stance with eyes open, eyes closed and vision and/or ankle proprioceptive inputs selectively altered by servo-controlling the visual surround and/or support surface to the subject s center of mass sway. Posture data was normalized using a log transformation and motion sickness data were normalized using the square root. In general, we found that exposure to VR resulted in decrements in postural stability. The largest decrements were observed in the tests performed immediately following exposure to VR and showed a fairly rapid recovery across the remaining test sessions. In addition, subjects generally showed improvement across days. We found significant main effects for day and time for the composite equilibrium score and for sensory organization tests (SOT) 1, 2 and 6. Significant main effects were observed for day for SOT 3 and 5. Although we found no significant main effects for gender (when center of gravity was used as a covariate), we did observe significant gender X time interaction effects for composite equilibrium and for SOT 1, 3, 4 and 5. Women appeared to show larger decrements in postural stability immediately after exposure to VR than men, but recover more quickly than n. Finally, we found no significant main effects for type of VR device or for exposure duration, however, these factors did interact with other factors during some of the SOTs. Subjects exhibited rapid recovery of motion sickness symptoms across time following exposure to VR and significantly less severe symptoms across days. We did not observe main effects for gender, type of device or duration of exposure. Individuals recovered from the detrimental effects of exposure to virtual reality on postural control and motion sickness within one hour. Sickness severity and initial decrements in postural equilibrium decreases over days, which suggests that subjects become dual-adapted over time. These findings provide some direction for developing training schedules for VR users that facilitate adaptation, and support the idea that preflight training of astronauts may serve as useful countermeasure for the sensorimotor effects of space flight.

Harm, D. L.↗

Effects of Learning on Performance When Computerized Dynamic Posturography Assessments Are Repeated

Background: Computerized dynamic posturography is widely used to measure balance control performance. Clinically, performance is assessed by comparing individual data against standards obtained from a normative population. When performing repeated assessments to track performance changes, one must be concerned with the influence of learning effects. Subjects do not have the opportunity to practice before the first session, and often a second session is not performed prior to an experiment. Thus, the objective of this activity was to examine learning effects on balance control performance. We hypothesize that subjects will perform better on the second session when compared to the first, and that the difference will be greater for more difficult conditions. Methods: Data were collected from 204 subjects using the NeuroCom Equitest system during quiet stance with arms crossed at the chest on up to two sessions. All subjects performed standard sensory organization tests (SOTs) including 1) normal vision, fixed support; 2) absent vision, fixed support; 3) sway-referenced vision, fixed support; 4) normal vision, swayreferenced support; 5) absent vision, sway-referenced support; and 6) sway-referenced vision, sway-referenced support. 120 of these subjects performed modified sensory organization tests (mSOTs 2 and 5) which included static (20 back) and dynamic (20, 0.33Hz) head tilts. Median equilibrium scores (mEQ) were calculated from peak-to-peak anterior-posterior sway across trials. Data collected on the first session were then compared with the second to examine learning effect. Results: There were no differences in mEQ scores between the first and second sessions for SOTs 1, 2, and 4, while mEQ scores were higher for the second session when compared to the first for SOTs 3, 5, and 6 and for all mSOTs. Discussion: An additional familiarization session or practice trials prior to the first session may be necessary for more challenging SOT and mSOT conditions to minimize learning effect.

Taylor, Laura C.↗

Effects of 30-, 60-, and 90-Day Bed Rest on Postural Control in Men and Women

INTRODUCTION Head-down-tilt bed rest (HDT) has been used as a safe gr ound-based analog to mimic and develop countermeasures for the physiological effects of spaceflight, including decrements in postural stability. The purpose of this investigation was to characterize the effects of 30-, 60-, and 90-day bed rest on postural control in men and women. METHODS Twenty-nine subjects (18M,11F) underwent 13 days of ambula tory acclimatization and were placed in 6? HDT for 30 (n=12), 60 (n=8), or 90 (n=9) days, followed by 14 days of ambulatory recovery. Computerized dynamic posturography (CDP) was used to assess changes in sensory and motor components of postural control, and recovery after HDT. Sensory Organization Tests (SOTs) objectively evaluate one?s ability to effectively use or suppress visual, vestibular, and proprioceptive information for postural control. Stability during the SOTs was assessed using peak-to-peak sway and convergence toward stability limits to derive an equilibrium score. Motor Control Tests (MCTs) evaluate one?s ability to recover from unexpected support surface perturbations, with performance determined by center-of-pressure path length. Whole-body kinematic data were collected to determine body-sway strategy used to maintain stability during each condition. Baselines were determined pre-HDT. Recovery was tracked post-HDT on days 0, 1, 2, and 4. RESULTS Immediately after HDT, subjects showed decreased performance on most SOTs, primarily on sway-referenced support conditions, typically returning to baseline levels within 4 days. MCT performance was not significantly affected. There were no significant gender or duration differences in performance. Kinematic data revealed a tendency to use ankle strategy to maintain an upright stance during most SOT conditions. Interestingly, six subjects (2M,4F) experienced orthostatic intolerance and were unable to complete day 0 testing. CONCLUSION HDT mimics some un loading mechanisms of spaceflight and elicits orthostatic issues present post-spaceflight (contributing to instability); however, it does not sufficiently address the vestibular dysfunction which occurs post-spaceflight.

Esteves, Julie↗

Validation of A Sensorimotor Disorientation Ground Analog

INTRODUCTION Simulating the sensorimotor disorientation effects of gravity transitions after prolonged stays in microgravity is exceedingly challenging on Earth. In a previous study [1], a Sensorimotor Disorientation Analog (SDA) was developed based on subjective feedback from previously flown astronauts. The purpose of this study was to validate this SDA by comparing performance in movement tasks that have a wealth of spaceflight data against task performance while using the SDA. METHODS Thirty healthy non-astronaut subjects (17 males, 13 females; Mean ± SD, Age: 33.5 ± 7.2 years, Height: 68.0 ± 3.4 in, Weight: 164 ± 26 lbs.) volunteered to participate in this study. Subjects performed three movement tasks: computerized dynamic posturography (CDP), obstacle walk, and tandem walk. For CDP, subjects maintained an upright stance for 20s with eyes closed on an unstable pitch sway-referenced platform with head erect (sensory organization test (SOT)-5) and with head pitch ±20° to an auditory cue(SOT-5M). The obstacle walk involved a sit-to-stand with 10s of quiet stance followed by walking to and around a cone placed 4m away while navigating a 30cm obstacle to the cone and back. The tandem walk involved walking heel-to-toe for approximately 10-12 steps with eyes open and eyes closed. Subjects performed the three movement tasks under three levels of the SDA replicating different time points of recovery: none (preflight), low (Return (R)+24- 48hours), and high (R+0- 24hours). The SDA included galvanic vestibular stimulation (GVS) to disorient the vestibular system and a weighted suit (trunk, wrists, and ankles) to alter proprioceptive feedback and replicate subjective heaviness. RESULTS As the SDA magnitude increased, overall performance outcomes decreased. However, the ability of the SDA to replicate the range of astronaut postflight performance was task dependent. CDP SOT-5 performance across SDA levels closely replicated astronaut performance at all time points. SOT-5M, however, had minimal performance changes across SDA levels and was unable to replicate astronaut performance. The obstacle walk showed performance changes across SDA levels and matched astronaut performance preflight and at R+24-48hrs (low). Obstacle walk performance at the high SDA level was reduced in comparison to the low level; however, it was not replicative of astronaut performance immediately after landing. Last, tandem walk had distinct groupings of performance across SDA levels and was able to elicit a high level of disorientation consistent with R+0-24 hours (high) postflight performance for eyes open and eyes closed. The low SDA level for both eyes open and eyes closed was more disruptive than previous crewmember performance at the R+24-48 hours timepoint. CONCLUSION The SDA was developed to replicate postflight sensorimotor disruptions. However, it is well-known that immediately post-landing, astronauts can experience motion sickness, dehydration, fatigue, orthostatic intolerance, illusory sensations, lumbar pain, etc. This multi-system response to return to 1G varies widely across astronauts and, as such, it was not unexpected that the extreme ends of responses in the R+0-24hrs time period were the most difficult to replicate. These results suggest that the SDA levels are able to elicit distinct performance groupings and, although not able to perfectly replicate R+0-24hrs, the SDA did replicate a large range of performance after return to Earth.

S C Moudy↗

Steps toward interstellar silicate dust mineralogy

One of the most certain facts on interstellar dust is that it contains grains with silicon oxygen tetrahedra (SOT), the internal vibrations of which cause the well known silicate bands at 10 and 18 microns. The broad and almost structureless appearance of them demonstrates lack of translation symmetry in these solids that must be considered amorphous or glassy silicates. There is no direct information on the cations in these interstellar silicates and on the number of bridging oxygens per tetrahedron (NBO). Comparing experimental results gained on amorphous silicates, e.g., silicate glasses, of cosmically most abundant metals (Mg, Fe, Ca, Al) with the observations is the only way to investigate interstellar silicate dust mineralogy (cf, Dorschner and Henning, 1986). At Jena University Observatory IR spectra of submicrometer-sized grains of pyroxene glasses (SSG) were studied. Pyroxenes are common minerals in asteroids, meteorites, interplanetary, and supposedly also cometary dust particles. Pyroxenes consist of linearly connected SOT (NBO=2). In the vitreous state reached by quenching melted minerals, the SOT remain nearly undistorted (Si-O bond length unchanged); the Si-O-Si angles at the bridging oxygens of pyroxenes, however, scatter statistically. Therefore, the original cation oxygen symmetry of the crystal (octahedral and hexahedral coordination by O) is completely lost. The blended bands at 10 and 18 microns lose their diagnostic differences and become broad and structureless. This illustrates best the basic problem of interstellar silicate mineral diagnostics. Optical data of glasses of enstatite, bronzite, hypersthene, diopside, salite, and hedenbergite have been derived. Results of enstatite (E), bronzite (B), and hypersthene (H) show very good agreement with the observed silicate features in the IR spectra of evolutionarily young objects that show P-type silicate signature according to the classification by Gurtler and Henning (1986). Compositional parameters and main characteristics of experimental SSG spectra in IR for the glasses E, B, and H are shown in tabular form. Results fit excellently the relations derived by Koike and Hasegawa (1987) and suggest that the band ratio of the astronomical silicate by Draine and Lee (1984) is too low.

Dorschner, J.↗