At least 19 records

A vareity of Hg capture solutions are available

While vacating the Clean Air Mercury Rule (CAMR) has postponed implementation of capturing mercury emitted by coal-fired power plants improvements in ways to capture and monitor mercury have continued. One method of enhancing Hg capture from FGD and SCR is to treat the coal by adding a halogen, such as calcium bromide in Alstom's KNX process prior to combustion. Power plants without FGD usually use sorbent injection, mostly an activated carbon, upstream of a particulate control device. 1 fig.

01 COAL, LIGNITE, AND PEAT↗

Mercury control in 2009

Although activated carbon injection (ACI) has been proven to be effective for many configurations and is a preferred option at many plants sufficient quantities of powdered activated coking (PAC) must be available to meet future needs. The authors estimate that upcoming federal and state regulations will result in tripling the annual US demand for activated carbon to nearly 1.5 billion lb from approximately 450 million lb. Rapid expansion of US production capacity is required. Many PAC manufacturers are discussing expansion of their existing production capabilities. One company, ADA Carbon Solutions, is in the process of constructing the largest activated carbon facility in North America to meet the future demand for PAC as a sorbent for mercury control. Emission control technology development and commercialization is driven by regulation and legislation. Although ACI will not achieve > 90% mercury control at every plant, the expected required MACT legislation level, it offers promise as a low-cost primary mercury control technology option for many configurations and an important trim technology for others. ACI has emerged as the clear mercury-specific control option of choice, representing over 98% of the commercial mercury control system orders to date. As state regulations are implemented and the potential for a federal rule becomes more imminent, suppliers are continuing to develop technologies to improve the cost effectiveness and limit the balance of plant impacts associated with ACI and are developing additional PAC production capabilities to ensure that the industry's needs are met. The commercialisation of ACI is a clear example of industry, through the dedication of many individuals and companies with support from the DOE and EPRI, meeting the challenge of developing cost-effectively reducing emissions from coal-fired power plants. 7 refs., 1 fig.

01 COAL, LIGNITE, AND PEAT↗

Mercury capture within coal-fired power plant electrostatic precipitators: model evaluation

Efforts to reduce anthropogenic mercury emissions worldwide have recently focused on a variety of sources, including mercury emitted during coal combustion. Toward that end, much research has been ongoing seeking to develop new processes for reducing coal combustion mercury emissions. Among air pollution control processes that can be applied to coal-fired boilers, electrostatic precipitators (ESPs) are by far the most common, both on a global scale and among the principal countries of India, China, and the U.S. that burn coal for electric power generation. A previously reported theoretical model of in-flight mercury capture within ESPs is herein evaluated against data from a number of full-scale tests of activated carbon injection for mercury emissions control. By using the established particle size distribution of the activated carbon and actual or estimated values of its equilibrium mercury adsorption capacity, the incremental reduction in mercury concentration across each ESP can be predicted and compared to experimental results. Because the model does not incorporate kinetics associated with gas-phase mercury transformation or surface adsorption, the model predictions represent the mass-transfer-limited performance. Comparing field data to model results reveals many facilities performing at or near the predicted mass-transfer-limited maximum, particularly at low rates of sorbent injection. Where agreement is poor between field data and model predictions, additional chemical or physical phenomena may be responsible for reducing mercury removal efficiencies. 26 refs., 5 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Copper-doped silica materials silanized with bis-(triethoxy silyl propyl)-tetra sulfide for mercury vapor capture

The use of Cu-S sites for Hg capture from the gas phase has been successfully applied to a silica-based platform using an S4 organic polysulfane and copper sulfate. The maximum fixed-bed equilibrium capacity achieved using these materials was 19 789 {mu}g Hg.g{sup -1} sorbent for a material with 2.5 wt % Cu and 6 wt % S. An optimal S level was determined to be around 3 wt % because enhancement of capacity was only 18% when increasing from this 3 to 6 wt %. The rate of adsorption in pure beds ranged from 0.6 to 1.6 {mu}g Hg.min{sup -1} depending on the inlet concentration. Differences in breakthrough times suggest that material deposition is not uniform. When compared to two other platforms, commercially available Darco HG-LH and previously tested Fe-Cu-S4 nanoaggregates, the Si-1 material performed the best in fixed-bed testing. During entrained-flow testing, a steady-state Hg removal of 82% was achieved using Si-1 at injection rates of both 6 x 10{sup -5} and 1.2 x 10{sup -4} g.L{sup -1}.h{sup -1}. The lack of increase in Hg removal when the injection rate is doubled suggests that pore accessibility is the rate-controlling step during dynamic Hg capture. A calculation of the approximate pore usage based on injection testing helped confirm this observation. During injection testing, the performance of Si-1 was only diminished 10% when exposed to 20 ppm SO{sub 3}. This is an encouraging result for flue-gas applications where SO{sub 3} levels range from 1 to 40 ppm. Testing demonstrated that Si-1 is stable when exposed to leaching conditions after concrete blending and cement impregnation. This is an important aspect to consider for injection because the sale of fly ash for concrete is a key cost-recovery tool for power plants. 27 refs., 8 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Mercury capture from flue gas using palladium nanoparticle-decorated substrates as injected sorbent

Although the Clean Air Mercury Rule (CAMR) was recently vacated by the District of Columbia Court of Appeals, efficient mercury (Hg) capture is still an important topic for the coal-fired power plant industry. Several states have Hg emission regulations that are even more stringent than CAMR guidelines. All coals contain Hg, which is released during combustion. Significant research efforts have been made to capture this toxic element before it is released to the atmosphere where it can stay suspended and travel for great distances. A variety of approaches have been examined, among which the injection of sorbent materials such as powdered activated carbon (PAC) is the current method of choice. The work presented here examined the mercury capture capability of various carbon substrates decorated with metal nanoparticles when injected as sorbents. Sorbent injections were carried out in a Hg in air mixture for laboratory-scale screening and in a real flue gas at a coal-fired power plant. It was found that palladium-decorated carbon substrates showed excellent mercury capture capabilities, with total efficiencies greater than 90% in laboratory-scale tests. In the real flue gas, the total efficiency was on the order of 60%, comparable to the benchmark commercial sorbent Darco Hg-LH, a brominated PAC, although the tested adsorbents had much lower surface areas. The results of this study are presented herein. Novel mercury capture from a coal-fired flue gas was achieved using carbon substrates decorated with palladium nanoparticles. 15 refs., 7 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Projections of global mercury emissions in 2050.

Global Hg emissions are presented for the year 2050 under a variety of assumptions about socioeconomic and technology development. We find it likely that Hg emissions will increase in the future. The range of 2050 global Hg emissions is projected to be 2390-4860 Mg, compared to 2006 levels of 2480 Mg, reflecting a change of -4% to +96%. The main driving force for increased emissions is the expansion of coal-fired electricity generation in the developing world, particularly Asia. Our ability to arrest the growth in Hg emissions is limited by the relatively low Hg removal efficiency of the current generation of emission control technologies for coal-fired power plants (flue-gas desulfurization). Large-scale deployment of advanced Hg sorbent technologies, such as Activated Carbon Injection, offers the promise of lowering the 2050 emissions range to 1670-3480 Mg, but these technologies are not yet in commercial use. The share of elemental Hg in total emissions will decline from today's levels of {approx}65% to {approx}50-55% by 2050, while the share of divalent Hg will increase. This signals a shift from long-range transport of elemental Hg to local deposition of Hg compounds though emissions of both species could increase under the worst case.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Sorbent Injection for Mercury Control

ADA-ES, Inc., with support from DOE/NETL, EPRI, and industry partners, studied mercury control options at six coal-fired power plants. The overall objective of the this test program was to evaluate the capabilities of activated carbon injection at six plants: Sunflower Electric's Holcomb Station Unit 1, AmerenUE's Meramec Station Unit 2, Missouri Basin Power Project's Laramie River Station Unit 3, Detroit Edison's Monroe Power Plant Unit 4, American Electric Power's Conesville Station Unit 6, and Labadie Power Plant Unit 2. These plants have configurations that together represent 78% of the existing coal-fired generation plants. The financial goals for the program established by DOE/NETL were to reduce the uncontrolled mercury emissions by 50 to 70% at a cost 25 to 50% lower than the target established by DOE of $60,000 per pound of mercury removed. Results from testing at Holcomb, Laramie, Meramec, Labadie, and Monroe indicate the DOE goal was successfully achieved. However, further improvements for plants with conditions similar to Conesville are recommended that would improve both mercury removal performance and economics.

01 COAL, LIGNITE, AND PEAT↗

SO{sub 3} effect on mercury control

Utilities are counting on their flue gas desulfurization (FGD) scrubbers and selective catalytic reduction (SCR) systems to control mercury as well as pollutants such as SO{sub 2} and NOx. As more stringent emission limits are phased in, utilities will likely need supplemental measures such as activated carbon injection (ACI) to further reduce emissions. However, SO{sub 3} could foul this strategy and potentially jeopardize the ability of some coal-fired power plants to meet future mercury emission limits. A growing consensus exists among emissions control engineers and researchers that the presence of SO{sub 3} in the flue gas from coal-fired boilers reduces the capacity of fly ash and/or activated carbon to adsorb gaseous mercury species. The impact of SO{sub 3}, which is actually a combination of SO{sub 3} and H{sub 2}SO{sub 4} vapor, has been investigated on a fundamental level using approaches such as fixed-bed reactors and activated carbons. Pilot testing has provided mercury removal efficiency data on actual flue gas over a wide range of SO{sub 3} concentrations. If SO{sub 3} threatens the feasibility of low capital-cost approaches involving activated carbon, utilities will be forced to explore other more costly options. One example is the use of mercury catalytic oxidation to boost mercury removal efficiencies in wet scrubbers. However, catalytic oxidation of mercury using SCR catalysts may have unintended consequences. A better alternative may be to remove the SO{sub 3} so it does not interfere with the removal of mercury via the fly ash and/or activated carbon for example using sodium sorbents. The article outlines research projects on alternatives. 4 figs.

01 COAL, LIGNITE, AND PEAT↗

How carbon-based sorbents will impact fly ash utilization and disposal

The injection of activated carbon flue gas to control mercury emissions will result in a fly ash and activated carbon mixture. The potential impact of this on coal combustion product disposal and utilization is discussed. The full paper (and references) are available at www.acaa-usa.org. 1 tab., 2 photos.

01 COAL, LIGNITE, AND PEAT↗

Activated carbon injection - a mercury control success story

Almost 100 full-scale activated carbon injection (ACI) systems have been ordered by US electric utilities. These systems have the potential to remove over 90% of the mercury in flue, at a cost below $10,000 per pound of mercury removal. Field trials of ACI systems arm outlined. 1 fig.

01 COAL, LIGNITE, AND PEAT↗

Computer simulation as a NOx reduction design tool

Nalco Mobotec engineers were charged with reducing emissions on a utility boiler converted from burning oil to eastern bituminous coal using the company's Rotamix selective noncatalytic reduction (SNCR) system which injects urea into the furnace. A CFD simulation of the existing boiler was first conducted and then the furnace was simulated with the SNCR system added and the design was optimised. Operating and capital costs were minimised by optimal placement of 50 injector ports. 6 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Bringing down the cost of SO{sub 2} and NOx removal

A twist of an old technique, flue gas recirculating, helps prevent slagging in the upper furnace and convective pass, according to pilot testing recently completed by APTECH CST and the South Research Institute. The technology, along with a companion technology for furnace sorbent and urea injection for SO{sub 2} and NOx control, could help owner/operators of smaller, older coal-fired plants meet emissions limits at a reasonable cost. The article reviews the details and results of initial pilot-scale testing. Results met all the company's expectations when testing Powder River Basin and Galatia coals. A full-scale project is planned for operation in 2009. 7 figs.

01 COAL, LIGNITE, AND PEAT↗

Performance of copper chloride-impregnated sorbents on mercury vapor control in an entrained-flow reactor system

An entrained-flow system has been designed and constructed to simulate in-flight mercury (Hg) capture by sorbent injection in ducts of coal-fired utility plants. The test conditions of 1.2-sec residence time, 140{degree}C gas temperature, 6.7 m/sec (22 ft/sec) gas velocity, and 0-0.24 g/m{sup 3} (0-15 lbs of sorbent per 1 million actual cubic feet of flue gas sorbent injection rates were chosen to simulate conditions in the ducts. Four kinds of sorbents were used in this study. Darco Hg-LH (lignite-based) served as a benchmark sorbent with which Hg control capability of other sorbents could be compared. Also, Darco-FGD (lignite-based) was used as a representative raw activated carbon sorbent. Two different copper chloride-impregnated sorbents were developed in the laboratory and tested in the entrained-flow system to examine the possibility of using these sorbents at coal-fired power plants. The test results showed that one of the copper chloride sorbents has remarkable elemental mercury (Hg{sup 0}) oxidation capability, and the other sorbent demonstrated a better performance in Hg removal than Darco Hg-LH. 13 refs., 4 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Enhancement of mercury capture by the simultaneous addition of hydrogen bromide (HBr) and fly ashes in a slipstream facility

Low halogen content in tested Powder River Basin (PRB) coals and low loss of ignition content (LOI) in PRB-derived fly ash were likely responsible for higher elemental mercury content (averaging about 75%) in the flue gas and also lower mercury capture efficiency by electrostatic precipitator (ESP) and wet-FGD. To develop a cost-effective approach to mercury capture in a full-scale coal-fired utility boiler burning PRB coal, experiments were conducted adding hydrogen bromide (HBr) or simultaneously adding HBr and selected fly ashes in a slipstream reactor (0.152 x 0.152 m) under real flue gas conditions. The residence time of the flue gas inside the reactor was about 1.4 s. The average temperature of the slipstream reactor was controlled at about 155{sup o}C. Tests were organized into two phases. In Phase 1, only HBr was added to the slipstream reactor, and in Phase 2, HBr and selected fly ash were added simultaneously. HBr injection was effective (>90%) for mercury oxidation at a low temperature (155{sup o}C) with an HBr addition concentration of about 4 ppm in the flue gas. Additionally, injected HBr enhanced mercury capture by PRB fly ash in the low-temperature range. The mercury capture efficiency, at testing conditions of the slipstream reactor, reached about 50% at an HBr injection concentration of 4 ppm in the flue gas. Compared to only the addition of HBr, simultaneously adding bituminous-derived fly ash in a minimum amount (30 lb/MMacf), together with HBr injection at 4 ppm, could increase mercury capture efficiency by 30%. Injection of lignite-derived fly ash at 30 lb/MMacf could achieve even higher mercury removal efficiency (an additional 35% mercury capture efficiency compared to HBR addition alone). 25 refs., 5 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Bench-scale studies of in-duct mercury capture using cupric chloride-impregnated carbons

A brominated activated carbon (Darco Hg-LH) and cupric chloride-impregnated activated carbon (CuCl{sub 2}-ACs) sorbent have been tested in a bench-scale entrained-flow reactor system which was developed for simulating in-flight mercury capture in ducts upstream of particulate matter control devices. The bench-scale experimental system has been operated with the conditions of a residence time of 0.75 s and a gas temperature of 140{sup o}C to simulate typical conditions in the duct of coal-fired exhaust gas. In addition, sorbent deposition on walls which can occur in a laboratory-scale system more than in a full-scale system was significantly reduced so that additional mercury capture by the deposited sorbent was minimized. In the entrained-flow system, CuCl{sub 2}-ACs demonstrated similar performance in Hg adsorption and better performance in Hg{sup 0} oxidation than Darco Hg-LH. In addition, the carbon content of those sorbents was found to determine their Hg adsorption capability in the entrained-flow system. The bench-scale entrained-flow system was able to demonstrate the important Hg adsorption and oxidation characteristics of the tested sorbents. 18 refs., 9 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Removing mercury from coal emissions: options for ash-friendly technologies

The article gives a brief description of techniques to remove mercury emitted from coal-fired power plants and discusses environmental considerations associated with the effect of emission controls on coal fly ash. Techniques covered include use of injected mercury sorbents (activated carbon, metal oxide catalysts, MerCAP{trademark} and MercScreen{trademark}) and fuel cleaning. Technologies currently being researched are mentioned. 8 refs.