Sodium vapor experiment Quarterly progress report, 1 Jul. - 30 Sep. 1966
Dynamics of upper atmosphere investigated through analysis of motion of sodium vapor trails ejected from sounding rockets
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Dynamics of upper atmosphere investigated through analysis of motion of sodium vapor trails ejected from sounding rockets
Observations of upper atmosphere made by analysis of sodium vapor trails ejected from sounding rockets - wind pattern variations and turbulence
We report improvements in conversion efficiency for third harmonic generation in sodium and rubidium vapor. 30-psec pulses of radiation at 1.064 micron have been converted to 0.3547 micron with an energy conversion efficiency of 10%. Factors limiting conversion efficiency are discussed.
Regulation of sodium excretion in dog, and effects of atrial size and function upon secretion of sodium load - circulatory response to upright tilt
Observations of emission from sodium presumed to have been ejected from Io in the orbital plane of the Gallilean satellites and extending outward to at least 35 Jupiter radii are reported. Spectra of the sodium D line were observed to have an intensity of 20 to 30 R. Mechanisms for the escape of sodium from Io after sputtering from the surface are: (1) ejection from Io at velocities greater than Jupiter escape velocity, (2) ejection at velocities corresponding to orbits with apoapses of 35 Jupiter radii, and (3) ionization followed by magnetic field sweeping and recombination. The relative contributions of each mechanism are estimated and used to predict the sodium emission intensity at 35 Jupiter radii to be 7 to 8 R, a value considered to be in reasonable agreement with observations. Observations of emission line width and the correlation of intensity with the orbital phase of Io would provide further means of evaluating the proposed mechanisms of sodium ejection.
Mercury atmosphere - Sprague and Hunten, in collaboration with Katharina Lodders of Washington University, proposed, mainly on cosmochemical grounds, that S atoms are an important constituent of the atmosphere (30 times more abundant than sodium). This paper has appeared in Icarus. We also suggest that condensed sulfur is an excellent candidate for the radar-bright polar caps, more plausible than water ice because the latter is only barely stable even in permanently-shadowed craters. The best prospect for detection of the vapor is through its resonance lines, a triplet near 1814 A. Mercury is too close to the Sun to be observed by any existing space telescope, but there is some prospect that the search could be made from a Shuttle-based spectrograph such as Lyle Broadfoot's USTAR. Sprague and Hunten have completed an elaborate data analysis of over 100 measurements of the Na D lines, obtained with the 61-inch telescope and our echelle spectrograph. Full account has been taken of the radiative-transfer problem that arises because the Na atmosphere is not optically thin. The output of this code is used in another program that makes an elaborate inverse interpolation in two angles and optical depth and computes the effect of the seeing (always bad for Mercury). The seeing is determined by fitting cuts across a computed image to part of the spectrum adjacent to the sodium lines, and typically ranges from slightly less than 4 arcsec to worse than 6 (diameter at l/e of a Gaussian). The final result is a list of Na abundances, with some information on spatial distribution. One particularly interesting result of further analysis is a strong abundance maximum in the morning relative to the afternoon, confirming an earlier result for potassium, based on much fewer measurements. The analysis are completed during the extension of the present grant. This work depends heavily on the Hapke parameters used to estimate the reflectance of Mercury's surface. The paper by Domingue et al. examines the credibility of the available parameters, which are derived from disk-unresolved photometry, and concludes that errors in the derived Na abundances could be as great as 30%.
The effects of positive radial centrifugation (+Gz) on plasma resin activity (PRA) and renal function were assessed in 15 normal male subjects under carefully controlled conditions of Na, K, and water intake. Twenty minutes of +2.0 Gz resulted in significant decreases in the mean rate of sodium excretion and creatine clearance and in a doubling of PRA in seven sodium-depleted subjects (10 meq Na intake). In eight sodium-replete subjects (200 mq Na intake), 30 min of +2.0 Gz was also associated with a decrease in the mean rate of sodium excretion. As a consequence of a concurrent decrease in creatine clearance, the fractional excretion of sodium during centrifugation did not differ from control, suggesting that the changes in Na excretion were mediated primarily by renal hemodynamic factors, although enhanced renal tubular sodium reabsorption may also have played a role.
Creep analysis of polycrystalline sodium chloride in high temperature environment, and stress creep of sodium chloride-potassium chloride samples
This study was undertaken to explore the time course of the metabolic response to isohemic blood volume expansion (30%) in normotensive, unanesthetized Sprague-Dawley rats. Whole blood, drawn from a femoral artery catheter of conscious donor rats, was infused into the jugular vein of recipient rats. Blood samples were drawn from a carotid artery of recipient rats at time points beginning immediately post-volume expansion (IPVE) up through 5 days post-volume expansion (PVE). To characterize the attendant compensatory mechanisms, the plasma concentrations of electrolytes and fluid regulatory hormones were determined. Hematocrit began to raise IPVE and was significantly elevated above control IPVE 20, 30, 40, 60, and 90 min, and 2, 4, 6, 8, 12, and 24 hr PVE. Consistent with our current understanding of the hormonal response to excess volume, atrial natriuretic factor was significantly increased above the prevolume expansion (control) values 0-30 min PVE. Surprisingly, plasma aldosterone levels were significantly increased above control at 20 and 30 min and 6 hr PVE, whereas plasma renin activity was significantly decreased 30-40 min PVE. Plasma sodium was not changed from control values except for a significant increase at 6 hr post-volume expansion. Plasma potassium, osmolality, and arginine vasopressin levels were not altered by the volume expansion. These studies delineate the physiologic time scheme operative in the regulation of fluid volume during acute ischemic volume expansion.
The effects of the currently used U.S. Air Force (CSU-12/P) anti-G suit on renal function during positive radial acceleration (+Gz) were assessed in seven normal male subjects in balance on a 200 meq sodium diet. Following suit inflation in the seated position, +2.0 Gz for 30 min resulted in a decrease in the rate of sodium excretion from 125 plus or minus 19 to 60 plus or minus 14 microeq/min, which persisted during a 25-min recovery period. Fractional excretion of sodium also decreased significantly during +Gz. The magnitude of the antinatriuresis was indistinguishable from that observed during +Gz without suit inflation. In contrast to the antinatriuresis observed during centrifugation without suit, however, the antinatriuresis with suit was mediated primarily by an enhanced tubular reabsorption of sodium.
Use of NiF2 cathodes in medium-to-high-temperature rechargeable sodium batteries increases energy and power densities by 25 to 30 percent without detracting from potential advantage of safety this type of sodium battery offers over sodium batteries having sulfur cathodes. High-energy-density sodium batteries with metal fluoride cathodes used in electric vehicles and for leveling loads on powerlines.
Creep behavior of polycrystalline aluminum oxide and sodium chloride at high temperatures
To examine the efficacy of artificial gravity (AG) as a countermeasure to spaceflight deconditioning, intermittent AG produced by a horizontal short-radius centrifuge (SRC) was utilized on human test subjects deconditioned by bed rest. This poster will present the subject screening, study design, logistics, and implementation of the 41 day pilot study conducted at the University of Texas Medical Branch, Galveston, TX bed rest facility. An extensive screening process was employed to exclude subjects that were dissimilar to the U.S. astronaut population. Candidates underwent a modified U.S. Air Force Class III physical and tests of bone density, cardiovascular fitness, vestibular system function, psychological fitness and centrifuge tolerance. 15 subjects completed the study; 7 control and 8 AG treatment. All provided written consent to volunteer after the nature of the study and its hazards were clearly explained to them. Standard conditions were strictly regulated; Ta = 72 +/- 2 F, humidity = 70 +/- 5%, light/dark cycle 16h:8h. All fluid intake (minimum 28.5 ml/kg body weight/day) and urine output was monitored. Caloric intake was adjusted as necessary to maintain body weight. Carbohydrate, fat and protein were provided in a ratio of 55:30:15. Phosphorus intake was 1400 mg/d, sodium intake was 2 mmol/kg/d, potassium intake was 1.3 mmol/kg/d, and dietary calcium intake was 1000 mg/d. A physician examined each subject daily. During the first 11 days of the study protocol, subjects were ambulatory, but confined to the facility. Subjects participated in multiple baseline tests of bone, muscle, cardiovascular, sensory-motor, immunological, and psychological function. On the 12th day, subjects entered the bed rest phase of the study, during which they were confined to strict 6? head down tilt bed rest for 21 days. Beginning 24 hrs into this period, treatment subjects received 1 hour daily exposures to artificial gravity which was produced by spinning the subjects on a 3.0 m radius SRC. They were oriented radially in the supine position so that the centrifugal force was aligned with their long body axis, and while spinning, they #stood# on a force plate, supporting the centrifugal loading (2.5 g at the feet, 1.0 g at the heart). The subject station allowed free translation over approximately 10 cm to ensure full loading of the lower extremities and to allow for anti-orthostatic muscle contractions. Control subjects were positioned on the centrifuge but did not spin. Following the bed rest phase, subjects were allowed to ambulate again, but remained within the facility for an additional 9 days and participated in multiple follow-up tests of physiological function.
It is a well accepted practice in the discussion of lidars to compare systems by a performance factor given by the product of the transmitter power and receiver aperture. This form of the performance factor reflects the two key parameters that determine the amount of photons recorded from a given range bin; the amount of transmitted photons and the probability of collecting a scattered photon. We are interested in studying the propagation and breaking of gravity waves typically generated in the lower atmosphere. To study these waves requires high temporal and spatial resolution, as they have frequencies as high as 500 mHz and generate turbulent structures with vertical scales of less than 25 m. In the 80 - 100 km region of the atmosphere these measurements are most efficiently obtained by using resonance scattering from sodium atoms deposited by meteors. However, in the 30 - 80 km region, the most efficient scattering arises from molecules (Rayleigh scattering). Since the atmospheric scale height is nominally 7 km, this scattering becomes extremely weak above 60 km. Furthermore, present laser technology limits the power available for Rayleigh-scattering experiments to about 0.5 - 50 W. The transmitter for the lidar system under development at the University of Western Ontario uses a two-beam transmitter to simultaneously measure density perturbations and temperature from both Rayleigh and resonance scattering.
The design of a high-resolution tunable-dye laser-based lidar system for the study of the mesospheric sodium layer is presented and results of sodium measurements are indicated. The lidar system comprises a tunable flashlamp-pumped dye laser operating at the sodium D2 resonance line at 589.0 nm with a pulse width of 2 microsec FWHM and pulse frequency of 10 Hz and a telescope with a 1.22=m diameter Fresnel lens. Sodium profiles are obtained from the integration of 100 to 250 laser shots, with spatial and temporal resolution enhanced by two-dimensional filtering techniques. Measurements obtained over a 9-hour nighttime period illustrate the highly dynamic nature of the sodium layer, which was observed with a spatial resolution of 2 km and temporal resolution of 30 min. Observations made with a steerable apparatus have confirmed a presunrise enhancement of over 100 percent in sodium column abundance.
In a Stirling radioisotope system, heat must continually be removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. Normally, the Stirling convertor provides this cooling. If the converter stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS, and also ending the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) has been designed to allow multiple stops and restarts of the Stirling convertor in an Advanced Stirling Radioisotope Generator (ASRG). When the Stirling convertor is turned off, the VCHP will activate when the temperatures rises 30 C above the setpoint temperature. A prototype VCHP with sodium as the working fluid was fabricated and tested in both gravity aided and against gravity conditions for a nominal heater head temperature of 790 C. The results show very good agreement with the predictions and validate the model. The gas front was located at the exit of the reservoir when heater head temperature was 790 C while cooling was ON, simulating an operating Advanced Stirling Converter (ASC). When cooling stopped, the temperature increased by 30 C, allowing the gas front to move past the radiator, which transferred the heat to the case. After resuming the cooling flow, the front returned at the initial location turning OFF the VCHP. The against gravity working conditions showed a colder reservoir and faster transients.
Debilitating injury is accompanied by hypercortisolemia, muscle wasting, and disruption of the normal anabolic response to food. We sought to determine whether acute hypercortisolemia alters muscle protein metabolism following ingestion of a potent anabolic stimulus: essential amino acids (EAA). A 27-h infusion (80 microg. kg(-1). h(-1)) of hydrocortisone sodium succinate mimicked cortisol (C) levels accompanying severe injury (>30 microg/dl), (C + AA; n = 6). The control group (AA) received intravenous saline (n = 6). Femoral arteriovenous blood samples and muscle biopsies were obtained during a primed (2.0 micromol/kg) constant infusion (0.05 micromol. kg(-1). min(-1)) of l-[ring-(2)H(5)]phenylalanine before and after ingestion of 15 g of EAA. Hypercortisolemia [36.5 +/- 2.1 (C + AA) vs. 9.0 +/- 1.0 microg/dl (AA)] increased postabsorptive arterial, venous, and muscle intracellular phenylalanine concentrations. Hypercortisolemia also increased postabsorptive and post-EAA insulin concentrations. Net protein balance was blunted (40% lower) following EAA ingestion but remained positive for a greater period of time (60 vs. 180 min) in the C + AA group. Thus, although differences in protein metabolism were evident, EAA ingestion improved muscle protein anabolism during acute hypercortisolemia and may help minimize muscle loss following debilitating injury.
Interstellar 21 cm and Na D lines comparison in directions of 30 stars at intermediate and high galactic latitudes