Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SILVER 125”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A = 125

The 1999 evaluation for A = 125 mass chain (1999Ka26) has been revised using experimental results from decays and reactions. Adopted values for the level and decay properties are tabulated. Inconsistencies and discrepancies are noted.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel Metal Sulfides to Achieve Effective Capture and Durable Consolidation of Radionuclides

This report documents the work done under NEUP grant to examine the capability of novel chalcogels and some binary metal chalcogenides as a host matrix for the capture of gaseous iodine and the feasibility of their iodine-laden materials to be converted into a permanent waste form. The presented work was conducted over last two years. A number of novel chalcogels Zn 2 Sn 2 S 6 , Sb 4 Sn 4 S 12 , NiMoS 4 , CoMoS 4 , antimony sulfide (SbS x ) chalcogels, silver functionalized chalcogels and binary metal sulfides (Sb 2 S 3 ) were developed and studies for their iodine absorption efficacies. A new and simple route was devised for the large scale preparation of antimony sulfide chalcogel. The chalcogel was obtained by treating Sb 2 S 3 with Na 2 S in the presence of water followed by addition of formamide. The obtained gels have a low-density sponge like network of meso porous nature having BET surface area of 125 m 2 /g. The chalcogels, silver functionalized chalcogel and the binary metal sulfides were exposed to iodine vapors in a closed container. Silver-functionalized chalcogels and Sb 2 S 3 powders showed iodine uptake up to 100 wt%, the highest iodine uptake of 200 wt% was observed for the SbS-III chalcogel. The PXRD patterns of iodine-laden specimens revealed that iodine shows spontaneous chemisorption to the matrix used. The iodine loaded chalcogels and the binary chalcogenides were sealed under vacuum in fused silica ampoules and heated in a temperature controlled furnace. The consolidated products were analyzed by PXRD, energy dispersive spectroscopy (EDS), UV-Vis and Raman spectroscopy. The final products were found to be amorphous in most of the cases with high amount (~4-35 wt%) of iodine and aapproximately ~60- 90 % of the absorbed iodine could be consolidated into the final waste form. Alginate reinforced composite scaffolds with SbS/SnS chalcogels and Sb 2 S 3 bulk powder were also fabricated aiming to study their efficacy as host matrices in capturing the gaseous molecular iodine in dynamic mode from nuclear spent fuel. The obtained composites looks robust in comparison to their respective pristine chalcogels and Sb 2 S 3 bulk powder.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Cysteine sensing by plasmons of silver nanocubes

Noble metal nanoparticles are considered to be valuable nanostructures in the field of sensors due to their spectral response sensitivity to small changes in the surrounding refractive index which enables them to detect a small amount of molecules. In this research, we use silver nanocubes of about 50 nm length to detect low concentrations of cysteine, a semi-essential amino acid. Following cysteine adsorption onto the nanocubes, a redshift in the plasmonic modes was observed, enabling the detection of cysteine down to 10 µM and high sensitivity of about 125 nm/RIU (refractive index units). Furthermore, we found that multilayer adsorption of cysteine leads to the stabilization of the silver nanocubes. The cysteine growth onto the nanocubes was also characterized by high-resolution transmission electron microscopy (HR-TEM). - Highlights: • Silver nanocubes (50 nm length) are used to detect low concentrations of cysteine. • A redshift in the plasmonic modes was observed following cysteine adsorption onto the nanocubes. • The cysteine growth onto the nanocubes is also characterized by TEM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PVA Based Ternary Nanocomposites with Enhanced Properties Prepared by Using a Combination of Rice Starch Nanocrystals and Silver Nanoparticles

Ternary nanocomposite films exhibiting better properties were prepared by incorporating two different nanoparticles such as rice starch nanocrystals (RSN) and silver nanoparticles (AgNPs) together in polyvinyl alcohol (PVA) matrix at various concentrations. The morphological evaluation using atomic force microscopy revealed that the particle size of RSN nanoparticles varied from 50 to 125 nm. The nanocomposite films made using these nanoparticles were evaluated for its chemical, mechanical and thermal properties. FTIR spectra of the films revealed some specific vibrational bands of RSN along with the characteristic bands of PVA. The mechanical property analysis of nanocomposite films indicated better tensile strength and elongation properties, which can be attributed to the strong interaction of PVA with RSN and AgNPs. The thermal properties of these films were also evaluated. These ternary nanocomposites exhibited superior mechanical properties, which is very much beneficial as far as the end use applications are concerned.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Charge carrier effective mass and concentration derived from combination of Seebeck coefficient and Te 125 NMR measurements in complex tellurides

Thermoelectric materials utilize the Seebeck effect to convert heat to electrical energy. The Seebeck coefficient (thermopower), S, depends on the free (mobile) carrier concentration, n, and effective mass, m*, as S ~ m*/n 2/3 . The carrier concentration in tellurides can be derived from 125 Te nuclear magnetic resonance (NMR) spin-lattice relaxation measurements. The NMR spin-lattice relaxation rate, 1/T 1 , depends on both n and m* as 1/T 1 ~(m*) 3/2 n (within classical Maxwell-Boltzmann statistics) or as 1/T1~(m*) 2 n 2/3 (within quantum Fermi-Dirac statistics), which challenges the correct determination of the carrier concentration in some materials by NMR. Here it is shown that the combination of the Seebeck coefficient and 125 Te NMR spin-lattice relaxation measurements in complex tellurides provides a unique opportunity to derive the carrier effective mass and then to calculate the carrier concentration. This approach was used to study Ag x Sb x Ge 50–2x Te 50 , well-known GeTe-based high-efficiency tellurium-antimony-germanium-silver thermoelectric materials, where the replacement of Ge by [Ag+Sb] results in significant enhancement of the Seebeck coefficient. Thus, values of both m* and n derived using this combination show that the enhancement of thermopower can be attributed primarily to an increase of the carrier effective mass and partially to a decrease of the carrier concentration when the [Ag+Sb] content increases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-123: Anomalous Altitude Effect in Permanent Implant Brachytherapy Seeds

Purpose: Permanent seed implant brachytherapy procedures require the measurement of the air kerma strength of seeds prior to implant. This is typically accomplished using a well-type ionization chamber. Previous measurements (Griffin et al., 2005; Bohm et al., 2005) of several low-energy seeds using the air-communicating HDR 1000 Plus chamber have demonstrated that the standard temperature-pressure correction factor, P{sub TP}, may overcompensate for air density changes induced by altitude variations by up to 18%. The purpose of this work is to present empirical correction factors for two clinically-used seeds (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) for which empirical altitude correction factors do not yet exist in the literature when measured with the HDR 1000 Plus chamber. Methods: An in-house constructed pressure vessel containing the HDR 1000 Plus well chamber and a digital barometer/thermometer was pumped or evacuated, as appropriate, to a variety of pressures from 725 to 1075 mbar. Current measurements, corrected with P{sub TP}, were acquired for each seed at these pressures and normalized to the reading at ‘standard’ pressure (1013.25 mbar). Results: Measurements in this study have shown that utilization of P{sub TP} can overcompensate in the corrected current reading by up to 20% and 17% for the IsoAid Pd-103 and the Nucletron I-125 seed respectively. Compared to literature correction factors for other seed models, the correction factors in this study diverge by up to 2.6% and 3.0% for iodine (with silver) and palladium respectively, indicating the need for seed-specific factors. Conclusion: The use of seed specific altitude correction factors can reduce uncertainty in the determination of air kerma strength. The empirical correction factors determined in this work can be applied in clinical quality assurance measurements of air kerma strength for two previously unpublished seed designs (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) with the HDR 1000 Plus well chamber.

07 ISOTOPE AND RADIATION SOURCES↗

Study of CNT growth using nanocatalyst Ag precursor by HWC-VHF-PECVD

The study of CNT growth has been done by using silver (Ag) nanocatalyst as a guide precursor on corning glass 7059 substrate. The silver catalyst was prepared by the evaporation method by varying deposition time for 50, 25, and 14 seconds. The silver films were then annealed at temperature of 400°C for 4 hours. From Scanning Electron Microscope (SEM) and Energy Dispersive X-ray Spectroscopy (EDX) results the grain sizes are 65 nm, 57 nm, and 33 nm, and also the atomic compositions are 6,06%, 4,52%, and 3,73% for 14, 25 and 50 seconds samples, respectively. The 33 nm samples were then used for CNT growth by using Hot Wire Cell (HWC) – Very High Frequency (VHF) – Plasma Enhanced Chemical Vapor Deposition (PECVD) at 275 ° C deposition temperature and pressure of 300 mTorr. The rf power was varied from 8 to 20 watts, with deposition time for 60 minutes. The methane (CH4) 99.999% was used as Carbon sources. Hydrogen gas (H2) was used to etch the oxide layer formed during the pre-deposition process. The diameter and length for the CNT are 125 nm and 1.650 to 2.989 nm respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AGR-2 Loose Particle Heating Tests in the Furnace for Irradiated TRISO Testing

A furnace system was developed to thermally expose individual tristructural-isotropic (TRISO) coated particles to expand upon established postirradiation examination (PIE) safety testing that is used to explore particle failures and fission product release from compacts. Two systems were installed in the Irradiated Fuels Examination Facility (IFEL) at Oak Ridge National Laboratory (ORNL). The targeted design was intended to be simple and flexible to allow a range in conditions to be explored. Initial inert atmosphere testing indicated the presence of particle failures, so modifications to the testing approach were implemented to improve the furnace operation. Ultimately, burnback particles were analyzed to provide a direct measurement of fission product release, thus avoiding the complications from integral release that were observed during whole compact testing. Particles were exposed to temperatures ranging 1,150–1,300°C for up to 1,500 h and 1,600°C up to 500 h. No indication of uniform release of fission products such as 106 Ru, 125 Sb, or 154 Eu was observed, however, indication of particle dependent 154 Eu release was suggested for select particles. Exploration of 110m Ag release was limited to 1,150°C and 1,300°C up to 500 h. The analysis indicated that there was nonuniform release of 110m Ag and supports a possible bimodal temperature dependence on silver release.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model

Purpose: The model S700 Axxent electronic brachytherapy source by Xoft, Inc., was characterized by Rivard et al. in 2006. Since then, the source design was modified to include a new insert at the source tip. Current study objectives were to establish an accurate source model for simulation purposes, dosimetrically characterize the new source and obtain its TG-43 brachytherapy dosimetry parameters, and determine dose differences between the original simulation model and the current model S700 source design. Methods: Design information from measurements of dissected model S700 sources and from vendor-supplied CAD drawings was used to aid establishment of an updated Monte Carlo source model, which included the complex-shaped plastic source-centering insert intended to promote water flow for cooling the source anode. These data were used to create a model for subsequent radiation transport simulations in a water phantom. Compared to the 2006 simulation geometry, the influence of volume averaging close to the source was substantially reduced. A track-length estimator was used to evaluate collision kerma as a function of radial distance and polar angle for determination of TG-43 dosimetry parameters. Results for the 50 kV source were determined every 0.1 cm from 0.3 to 15 cm and every 1° from 0° to 180°. Photon spectra in water with 0.1 keV resolution were also obtained from 0.5 to 15 cm and polar angles from 0° to 165°. Simulations were run for 10{sup 10} histories, resulting in statistical uncertainties on the transverse plane of 0.04% at r = 1 cm and 0.06% at r = 5 cm. Results: The dose-rate distribution ratio for the model S700 source as compared to the 2006 model exceeded unity by more than 5% for roughly one quarter of the solid angle surrounding the source, i.e., θ ≥ 120°. The radial dose function diminished in a similar manner as for an {sup 125}I seed, with values of 1.434, 0.636, 0.283, and 0.0975 at 0.5, 2, 5, and 10 cm, respectively. The radial dose function ratio between the current and the 2006 model had a minimum of 0.980 at 0.4 cm, close to the source sheath and for large distances approached 1.014. 2D anisotropy function ratios were close to unity for 50° ≤ θ ≤ 110°, but exceeded 5% for θ < 40° at close distances to the sheath and exceeded 15% for θ > 140°, even at large distances. Photon energy fluence of the updated model as compared to the 2006 model showed a decrease in output with increasing distance; this effect was pronounced at the lowest energies. A decrease in photon fluence with increase in polar angle was also observed and was attributed to the silver epoxy component. Conclusions: Changes in source design influenced the overall dose rate and distribution by more than 2% in several regions. This discrepancy is greater than the dose calculation acceptance criteria as recommended in the AAPM TG-56 report. The effect of the design change on the TG-43 parameters would likely not result in dose differences outside of patient applicators. Adoption of this new dataset is suggested for accurate depiction of model S700 source dose distributions.

60 APPLIED LIFE SCIENCES↗

AGR-1 Compact 4-1-1 Post-Irradiation Examination Results

Destructive post-irradiation examination was performed on AGR-1 fuel Compact 4-1-1, which was irradiated to a final compact-average burnup of 19.4% FIMA (fissions per initial metal atom) and a time-average, volume-average temperature of 1072°C. The analysis of this compact focused on characterizing the extent of fission product release from the particles and examining particles to determine the condition of the kernels and coating layers. The work included deconsolidation of the compact and leach-burn-leach analysis, visual inspection and gamma counting of individual particles, metallurgical preparation of selected particles, and examination of particle cross-sections with optical microscopy, electron microscopy, and elemental analysis. Deconsolidation-leach-burn-leach (DLBL) analysis revealed no particles with failed TRISO or failed SiC layers (as indicated by very low uranium inventory in all of the leach solutions). The total fractions of the predicted compact inventories of fission products Ce-144, Cs-134, Cs-137, and Sr-90 that were present in the compact outside of the SiC layers were <2×10 -6 , based on DLBL data. The Ag-110m fraction in the compact outside the SiC layers was 3.3×10 -2 , indicating appreciable release of silver through the intact coatings and subsequent retention in the OPyC layers or matrix. The Eu-154 fraction was 2.4×10 -4 , which is equivalent to the inventory in one average particle, and indicates a small but measurable level of release from the intact coatings. Gamma counting of 61 individual particles indicated no particles with anomalously low fission product retention. The average ratio of measured inventory to calculated inventory was close to a value of 1.0 for several fission product isotopes (Ce-144, Cs-134, and Cs-137), indicating good retention and reasonably good agreement with the predicted inventories. Measured-to-calculated (M/C) activity ratios for fission products Eu-154, Eu-155, Ru-106, Sb-125, and Zr-95 were significantly less than 1.0. However, as no significant release of these fission products from compacts was noted during previous analysis of the AGR-1 capsule components, the low M/C ratios are most likely an indication of a bias in the inventories predicted by physics simulations of the AGR-1 experiment. The distribution of Ag-110m M/C ratios was centered on a value of 1.02 and was fairly broad (standard deviation of 0.18, with values as high as 1.42 and as low as 0.68). Based on all data gathered to date, it is believed that silver retention in the particles was on average relatively high, but that the broad distribution in values among the particles represents significant variation in the inventory of Ag-110m generated in the particles. Ceramographic analysis of particle cross-sections revealed many of the characteristic microstructures often observed in irradiated AGR-1 particles from other fuel compacts. Palladium-rich fission product clusters were observed in the IPyC and SiC layers near the IPyC-SiC interface of three Compact 4-1-1 particle cross-sections. In spite of the presence of fission product clusters in the SiC layer, no significant corrosion or degradation of the layer was observed in any of the particles examined.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In Situ ATR–SEIRAS of Carbon Dioxide Reduction at a Plasmonic Silver Cathode

Illumination of a voltage-biased plasmonic Ag cathode during CO 2 reduction results in a suppression of the H 2 evolution reaction while enhancing CO 2 reduction. This effect has been shown to be photonic rather than thermal, but the exact plasmonic mechanism is unknown. Here in this paper, we conduct an in situ ATR–SEIRAS (attenuated total reflectance–surface-enhanced infrared absorption spectroscopy) study of a sputtered thin film Ag cathode on a Ge ATR crystal in CO 2 -saturated 0.1 M KHCO 3 over a range of potentials under both dark and illuminated (365 nm, 125 mW cm –2 ) conditions to elucidate the nature of this plasmonic enhancement. We find that the onset potential of CO 2 reduction to adsorbed CO on the Ag surface is -0.25 V RHE and is identical in the light and the dark. As the production of gaseous CO is detected in the light near this onset potential but is not observed in the dark until -0.5 V RHE , we conclude that the light must be assisting the desorption of CO from the surface. Furthermore, the HCO 3 – wavenumber and peak area increase immediately upon illumination, precluding a thermal effect. We propose that the enhanced local electric field that results from the localized surface plasmon resonance (LSPR) is strengthening the HCO 3 – bond, further increasing the local pH. This would account for the decrease in H 2 formation and increase the CO 2 reduction products in the light.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electromigration-induced back stress in critical solder length for three-dimensional integrated circuits

Because of the miniaturization of electronic devices, the reliability of electromigration has become a major concern when shrinking the solder dimensions in flip-chip joints. Fast reaction between solders and electrodes causes intermetallic compounds (IMCs) to form, which grow rapidly and occupy entire joints when solder volumes decrease. In this study, U-grooves were fabricated on Si chips as test vehicles. An electrode-solder-electrode sandwich structure was fabricated by using lithography and electroplating. Gaps exhibiting well-defined dimensions were filled with Sn3.5Ag solders. The gaps between the copper electrodes in the test sample were limited to less than 15 μm to simulate microbumps. The samples were stressed at various current densities at 100 °C, 125 °C, and 150 °C. The morphological changes of the IMCs were observed, and the dimensions of the IMCs were measured to determine the kinetic growth of IMCs. Therefore, this study focused on the influence of back stress caused by microstructural evolution in microbumps.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reactor Fuel Isotopics and Code Validation for Nuclear Applications

Experimentally measured isotopic concentrations of well characterized spent nuclear fuel (SNF) samples have been collected and analyzed by previous researchers. These sets of experimental data have been used extensively to validate the accuracy of depletion code predictions for given sets of burnups, initial enrichments, and varying power histories for different reactor types. The purpose of this report is to present the diversity of data in a concise manner and summarize the current accuracy of depletion modeling. All calculations performed for this report were done using the Oak Ridge Isotope GENeration (ORIGEN) code, an internationally used irradiation and decay code solver within the SCALE comprehensive modeling and simulation code. The diversity of data given in this report includes key actinides, stable fission products, and radioactive fission products. In general, when using the current ENDF/B-VII.0 nuclear data libraries in SCALE, the major actinides are predicted to within 5% of the measured values. Large improvements were seen for several of the curium isotopes when using improved cross section data found in evaluated nuclear data file ENDF/B-VII.0 as compared to ENDF/B-V-based results. The impact of the flux spectrum on the plutonium isotope concentrations as a function of burnup was also shown. The general accuracy noted for the actinide samples for reactor types with burnups greater than 5,000 MWd/MTU was not observed for the low-burnup Hanford B samples. More work is needed in understanding these large discrepancies. The stable neodymium and samarium isotopes were predicted to within a few percent of the measured values. Large improvements were seen in prediction for a few of the samarium isotopes when using the ENDF/B-VII.0 libraries compared to results obtained with ENDF/B-V libraries. Very accurate predictions were obtained for 133 Cs and 153 Eu. However, the predicted values for the stable ruthenium and rhodium isotopes varied as much as 10% of the measured values, and 109 Ag was consistently over-predicted by as much as 170%. In general, there is a larger uncertainty for modeling radioactive fission products when compared to either the actinides or the stable fission products in SNF. The relative C/E ratios ranged from a few percent for 137 Cs up to 60% and 100% for 106 Ru and 125 Sb, respectively. Limited or no radioactive fission products data exist in the current data sets for reactor types other than PWRs and BWRs. More work is needed in obtaining a greater diversity of radioactive fission product data. While performing this survey, issues leading to inconsistencies in nuclear fission yield data were discovered that specifically impacted the fission product noble gases. Emphasis was given to this legacy data, and corrective actions were taken as described in this report. After the fission yield data were corrected, the stable xenon and krypton fission products were predicted to within 5% of their measurements. However, preliminary results not explicitly given in this report indicate that the relative C/E ratio for the radioactive isotope 85 Kr varied as much as 10%. Due to the complex migration and the difficulty in measuring noble gases in the fuel, a more thorough investigation is needed to understand how accurately depletion codes can calculate these gas concentrations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The oxygen stable isotope composition of CRM 125-A UO 2 standard reference material

While there is a clear need for standardized reference materials for analytical calibrations and for inter-laboratory comparisons, there are not currently any for the oxygen stable isotopic composition of uranium oxides. In this paper we summarize the results from four laboratories by seven different methods of oxygen stable isotope analyses using fluorination techniques of CRM 125-A UO 2 Standard Reference Material. We synthesize these data and methods to arrive at a consensus oxygen stable isotope composition for CRM 125-A $δ$ 18 O = -9.63‰ (±0.29‰) VSMOW. We discuss methodological differences between analytical approaches, including furnace vs laser heating, fluorination using BrF 5 or ClF 3 , as well as calibration strategies. We highlight the potential effects of calibration scale compression from single-point calibrations using reference material with $δ$ 18 O values having a large relative difference from the sample being analyzed. We demonstrate how calibration scale compression can yield differences in calibrated $δ$ 18 O values up to ~2‰ for samples with ~20‰ difference from a single reference material, if the calibration slope of different analytical systems differs by 0.1. In conclusion, we suggest the use of liquid water calibration standards sealed in silver capillary tubes for multi-point calibrations of fluorination analysis systems.

07 ISOTOPE AND RADIATION SOURCES↗

Effects of Isothermal Aging on the Thermal Expansion of Several Sn-Based Lead-Free Solder Alloys

In this paper, effects of high-temperature aging on the thermal expansion behavior of several lead-free alloys SAC305, SAC387, Sn-3.5Ag, SnCu, SN100C (SnCu-Ni-Ge) and SnCu-0.01Ge have been explored. The coefficients of thermal expansion (CTEs) of the alloys have been experimentally determined over the temperature range 30-150 °C after isothermal aging at 125 °C for up to 30 days (720 h). The CTE values of SAC305, SAC387 and Sn-3.5Ag increase by 8-16% after 30 days of aging, while the CTE values of SnCu, SnCu-Ge and SN100C solders increase by only 3-6%. The CTE evolution of lead-free solders can be explained by microstructural changes observed during isothermal aging, which causes coarsening of various phases of the solder. As the phases coarsen, dislocation movement proceeds with a consequent increase in the average interparticle distance. The observation of CTE increases during isothermal aging suggests potential reliability problems for lead-free solder joints subjected to long-term aging exposures at high temperatures.

36 MATERIALS SCIENCE↗

SU-E-T-443: Geometric Uncertainties in Eye Plaque Dosimetry for a Fully Loaded 16 Mm COMS Plaque

Purpose: To determine the effect of geometric uncertainties in the seed positions in a COMS eye plaque on the central axis (CAX) dose. Methods: A Silastic insert was placed into a photopolymer 3D printed 16 mm COMS plaque, which was then positioned onto a custom-designed PMMA eye phantom. High resolution 3D images were acquired of the setup using a Siemens Inveon microPET/CT scanner. Images were acquired with the plaque unloaded and loaded with IsoAid I-125 seed shells (lack of silver core to minimize metal artifacts). Seed positions and Silastic thickness beneath each slot were measured. The measured seed coordinates were used to alter the seed positions within a standard 16 mm COMS plaque in Plaque Simulator v5.7.3 software. Doses along the plaque CAX were compared for the original and modified plaque coordinates using 3.5 mCi seeds with treatment times set to deliver 70 Gy to tumour apexes of 3.5, 5, and 10 mm height. Results: The majority of seeds showed length-wise displacement, and all seeds showed displacement radially outward from the eye center. The average radial displacement was 0.15 mm larger than the expected 1.4 mm offset, approximately half of which was due to increased Silastic thickness beneath each slot. The CAX doses for the modified seed positions were consistently lower for all tumour heights due to geometric displacement of the seeds; dose differences were found to increase to a maximum of 2.6% at a depth of ∼10 mm, after which they decreased due to the inverse square dose fall-off minimizing this effect. Conclusion: This work presents initial results of a broader dosimetric uncertainty evaluation for fully loaded COMS eye plaques and demonstrates the effects of seed positioning uncertainties. The small shifts in seed depths had noticeable effects on the CAX doses indicating the importance of careful Silastic loading. Funding provided by Alberta Cancer Foundation Grant #26655, Vanier Canada Graduate Scholarship, and Alberta Innovates Health Sciences Graduate Studentship.

60 APPLIED LIFE SCIENCES↗