Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Resolving small signal measurements in experimental plasma environments using calibrated subtraction of noise signals

The performance of many diagnostic and control systems within fusion and other fields of research are often detrimentally affected by spurious noise signals. This is particularly true for those (such as radiation or particle detectors) working with very small signals. Common sources of radiated and conducted noise in experimental fusion environments include the plasma itself and instrumentation. The noise complicates data analysis, as illustrated by noise on signals measured with the heavy ion beam probe (HIBP) installed on the Madison Symmetric Torus. The noise is time-varying and often exceeds the secondary ion beam current (in contrast with previous applications). Analysis of the noise identifies the dominant source as photoelectric emission from the detectors induced by ultraviolet light from the plasma. This has led to the development of a calibrated subtraction technique, which largely removes the undesired temporal noise signals from data. The advantages of the technique for small signal measurement applications are demonstrated through improvements realized on HIBP fluctuation measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying Different Classes of Seismic Noise Signals Using Unsupervised Learning

Abstract Proper classification of nontectonic seismic signals is critical for detecting microearthquakes and developing an improved understanding of ongoing weak ground motions. We use unsupervised machine learning to label five classes of nonstationary seismic noise common in continuous waveforms. Temporal and spectral features describing the data are clustered to identify separable types of emergent and impulsive waveforms. The trained clustering model is used to classify every 1 s of continuous seismic records from a dense seismic array with 10–30 m station spacing. We show that dominate noise signals can be highly localized and vary on length scales of hundreds of meters. The methodology demonstrates the complexity of weak ground motions and improves the standard of analyzing seismic waveforms with a low signal‐to‐noise ratio. Application of this technique will improve the ability to detect genuine microseismic events in noisy environments where seismic sensors record earthquake‐like signals originating from nontectonic sources.

Johnson, Christopher W.↗

Analysis of pump-to-signal noise transfer in two-stage ultra-broadband optical parametric chirped-pulse amplification

In optical parametric chirped-pulse amplification (OPCPA), pump temporal intensity modulation is transferred to the chirped-signal spectrum via instantaneous parametric gain and results in contrast degradation of the recompressed signal. We investigate, for the first time to our knowledge, the pump-to-signal noise transfer in a two-stage ultra-broadband OPCPA pumped by a single laser and show the dependence of pump-induced signal noise, characterized both before and after pulse compression, on the difference in pump-seed delay in the two stages. We demonstrate an up-to-15-dB reduction of the pump-induced contrast degradation via pump-seed delay optimization. Experiments and simulations show that, even when parametric amplifiers are operated in saturation, the pump-seed delay can be used to minimize the pump-induced contrast degradation that is attributed largely to the noises from the unsaturated edges of the pulse and that of the beam.

47 OTHER INSTRUMENTATION↗

Using time reversal with long duration broadband noise signals to achieve high amplitude and a desired spectrum at a target location

Time Reversal (TR) is a signal processing technique that can be used to focus acoustic waves to a specific location in space, with most applications aiming to create an impulsive focus. Here, this study instead aims to focus long-duration noise signals using TR. This paper seeks to generate higher amplitude noise at a desired location over an existing method of broadcasting equalized noise. Additionally, this paper explores various characteristics associated with focusing long duration noise using TR. The dependence of the focal amplitude on the duration of the focused signal is explored as well as the implications of using multiple sources when focusing noise. The focal amplitude decreases with longer duration and then levels off when the duration exceeds a few seconds. Coherent addition of focused noise is observed if all loudspeakers have coherent noise signals convolved with their reversed impulse responses. Lastly, focusing noise with a desired spectrum is explored.

42 ENGINEERING↗

Noise signal identification in time projection chamber data using deep learning model

Deep learning has been employed in various scientific fields and has provided promising results. Here, in this study, a deep learning classifier was implemented to improve the quality of data obtained from a time projection chamber. Digital waveforms of the detected signals were classified into the following three categories: particles, noises, and particles piled up with noises. A simple 1-dimensional convolutional neural network was developed for the classification. The model demonstrated an excellent performance on the test dataset. Its practical performance was also examined using track images and particle identification plots by comparing the original and clean data without the noise signals. The comparison clearly showed that the deep learning model improved the quality of data. The current study presents an effective application of the deep learning model for the time projection chamber data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multimachine data–based prediction of high-frequency sensor signal noise for resistive wall mode control in ITER

The high-frequency noise measured by magnetic sensors, at levels above the typical frequency of resistive wall modes, is analyzed across a range of present tokamak devices including DIII-D, JET, MAST, ASDEX Upgrade, JT-60U, and NSTX. A high-pass filter enables identification of the noise component with Gaussian-like statistics that shares certain common characteristics in all devices considered. A conservative prediction is made for ITER plasma operation of the high-frequency noise component of the sensor signals, to be used for resistive wall mode feedback stabilization, based on the multimachine database. The predicted root-mean-square n = 1 (n is the toroidal mode number) noise level is 10 4 to 10 5 G/s for the voltage signal, and 0.1 to 1 G for the perturbed magnetic field signal. The lower cutoff frequency of the Gaussian pickup noise scales linearly with the sampling frequency, with a scaling coefficient of about 0.1. As a result, these basic noise characteristics should be useful for the modeling-based design of the feedback control system for the resistive wall mode in ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving Signal-to-Noise Ratio (SNR) for Readout Signals Using Adaptive Filters on Reconfigurable Controls Hardware

This study investigates the optimization of Signal-to-Noise Ratio (SNR) in superconducting quantum computing readout signals through adaptive filtering. Quantum computing technology has the potential to revolutionize various fields by delivering exponential speedup in solving certain computational problems. However, the technology's practical implementation is hindered by the difficulty of extracting clean, reliable signals during the readout phase, with various sources of noise presenting a significant barrier to clean signals. This noise, often present in readout profiles due to imperfect isolation, degrades the system's overall SNR, thus impeding the ability to extract the quantum state accurately. The research leverages the power of adaptive filtering to improve the SNR of quantum computing readout signals. Specifically, an adaptive filter is implemented in a PYNQ overlay on an FPGA, and eventually will be connected to a quantum computing system. The system models the noise with a Least Mean Squares (LMS) adaptive filter, and then subtracts the estimated noise from the received signal to improve the SNR. A Direct Memory Access (DMA) channel is used to handle the signal processing, delivering efficient, high-speed data transfer between the PYNQ system and the hardware. The study explores the benefits of this adaptive filtering technique, potentially providing a significant contribution to practical and fast quantum computing.

Johnson, Hans↗

Improving Signal-to-Noise Ratio (SNR) for Readout Signals Using Adaptive Filters on Reconfigurable Controls Hardware

This study investigates the optimization of Signal-to-Noise Ratio (SNR) in superconducting quantum computing readout signals through adaptive filtering. Quantum computing technology has the potential to revolutionize various fields by delivering exponential speedup in solving certain computational problems. However, the technology's practical implementation is hindered by the difficulty of extracting clean, reliable signals during the readout phase, with various sources of noise presenting a significant barrier to clean signals. This noise, often present in readout profiles due to imperfect isolation, degrades the system's overall SNR, thus impeding the ability to extract the quantum state accurately. The research leverages the power of adaptive filtering to improve the SNR of quantum computing readout signals. Specifically, an adaptive filter is implemented in a PYNQ overlay on an FPGA, and eventually will be connected to a quantum computing system. The system models the n oise with a Least Mean Squares (LMS) adaptive filter, and then subtracts the estimated noise from the received signal to improve the SNR. A Direct Memory Access (DMA) channel is used to handle the signal processing, delivering efficient, high-speed data transfer between the PYNQ system and the hardware. The study explores the benefits of this adaptive filtering technique, potentially providing a significant contribution to practical and fast quantum computing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration of improvement in the signal-to-noise ratio of Thomson scattering signal obtained by using a multi-pass optical cavity on the Tokyo Spherical Tokamak-2

The multi-pass Thomson scattering (TS) scheme enables obtaining many photons by accumulating multiple TS signals. The signal-to-noise ratio (SNR) depends on the accumulation number. In this study, we performed multi-pass TS measurements for ohmically heated plasmas, and the relationship between SNR and the accumulation number was investigated. As a result, improvement of SNR in this experiment indicated similar tendency to that calculated for the background noise dominant situation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-FG-209-04: Testing of Digital Image Receptors Using AAPM TG-150’s Draft Recommendations - Investigating the Impact of Different Processing Parameters

Purpose: To evaluate implementation of AAPM TG-150’s draft recommendations via a parameter study for testing the performance of digital image receptors. Methods: Flat field images were acquired from 9 calibrated digital image receptors associated with 9 new portable digital radiography systems (Carestream Health, Inc.) based on the draft recommendations and manufacturer-specified calibration conditions (set of 4 images at input detector air kerma ranging from 1 to 25 µGy). Effects of exposure response function (linearized and logarithmic), ‘Presentation Intent Type’ (‘For Processing’ and ‘For Presentation’), detector orientation with respect to the anode-cathode axis (4 orientations; 900 rotations per iteration), different ROI sizes (5×5–40×40 mm{sup 2}) and elimination of varying dimensions of image border (0 mm i.e., without boundary elimination to 150 mm) on signal, noise, signal-to-noise ratio (SNR) and the associated nonuniformities were evaluated. Images were analyzed in Matlab and quantities were compared using ANOVA. Results: Signal, noise and SNR values averaged over 9 systems with default parameter values in draft recommendations were 4837.2±139.4, 19.7±0.9 and 246.4±10.1 (mean ± standard deviation), respectively (at input detector air kerma: 12.5 µGy). Signal, noise and SNR showed characteristic dependency on exposure response function and on ‘Presentation Intent Type’. These values were not affected by ROI size and detector orientation, but analysis showed that eliminating the edge pixels along the boundary was required for the noise parameter (coefficient of variation range for noise: 72%–106% and 3%–4% without and with boundary elimination; respectively). Local and global nonuniformities showed a similar dependence on the need for boundary elimination. Interestingly, computed non-uniformities showed agreement with manufacturer-reported values except for noise non-uniformities in two units; artifacts were seen in images from these two units highlighting the importance of independent evaluations. Conclusion: The effect of different parameters on performance characterization of digital image receptors was evaluated based on TG-150’s draft recommendations.

60 APPLIED LIFE SCIENCES↗

Improving Signal-to-Noise Ratio (SNR) for Quantum Readout Signals Using Adaptive Hardware Filters on FPGA

This research presents an innovative approach to improving the Signal-to-Noise Ratio (SNR) in superconducting quantum computing readout signals, utilizing FPGA-based adaptive filtering on the control board. Our solution aims to bolster quantum computations' reliability by providing a more accurate and precise way to obtain our readout traces and achieve a higher discernability between excitation states in real-time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apparatus, system, and method for sensor authentication

A method includes receiving an output signal from a sensor, recovering a noise signal from the output signal, comparing the noise signal with a stored baseline noise signature, and reporting authentication of the sensor if the comparison is within a pre-determined error limit. A sensor authentication apparatus, comprises a processor and a memory operably coupled with the processor. Instructions, when executed, cause the processor to separate a noise signal from a measured signal, and detect a noise signature match by comparing the noise signal with at least one stored baseline noise signature associated with the sensor. A sensor authentication system comprises a sensor authentication unit and a data acquisition unit. At least one of the sensor authentication unit and the data acquisition unit is configured to compare a noise signal with a baseline noise signature to authenticate the at least one sensor from among a plurality of sensors.

Svoboda, John M.↗

Lineshape spectroscopy with a very high resolution, very high signal-to-noise crystal spectrometer

We have developed a high-resolution x-ray spectrometer for measuring the shapes of spectral lines produced from laser-irradiated targets on the Orion laser facility. The instrument utilizes a spherically bent crystal geometry to spatially focus and spectrally analyze photons from foil or microdot targets. The high photon collection efficiency resulting from its imaging properties allows the instrument to be mounted outside the Orion chamber, where it is far less sensitive to particles, hard x-rays, or electromagnetic pulses than instruments housed close to the target chamber center in ten-inch manipulators. Moreover, Bragg angles above 50° are possible, which provide greatly improved spectral resolution compared to radially viewing, near grazing-incidence crystal spectrometers. These properties make the new instrument an ideal lineshape diagnostic for determining plasma temperature and density. We describe its calibration on the Livermore electron beam ion trap facility and present spectral data of the K-shell emission from highly charged sulfur produced by long-pulse as well as short-pulse beams on the Orion laser in the United Kingdom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Signal Signal-to -Noise Ratio (SNR) for Quantum Readout Signals Using Adaptive Hardware Filters on FPGA

This research presents an innovative approach to improving theSignalSignal-to -Noise Ratio (SNR) in superconducting quantumcomputing readout signals, utilizing adaptive filtering on thecontrol board. Our solution FPGA FPGA-based aims to bolsterquantum computations' reliability by providing a more accurateand precise way to obtain our readout traces and achieve ahigher discernability between excitation states in real real-time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗

Wireless Communications Based on the Spectral Interference of Ultrawideband Noise Random Signals

A method of transmitting information with the expansion of the spectrum based on spectral interference between the reference noise and the information noise signal with a delay of different time according to the stream of binary bits is proposed. The occurrence of intrasystem noises with a shift in evaluation of the autocorrelation effect at the output of a two-channel correlation receiver is found. The possibility of noise-resistant transmission of information during spectral modulation as a result of the superposition of completely incoherent ultrawideband noise chaotic signals is shown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Matrix9 silicon photomultiplier array for small-animal PET

Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm{sup 2} and the total size of the detector head is 47.8 × 46.3 mm{sup 2}. Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can resolve high-resolution scintillator arrays common in small-animal PET with adequate energy resolution and timing resolution over a large detector area. The modular design of the Matrix9 detector allows it to be used as a building block for simple, low channel-count, yet high performance, small animal PET or PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗