Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Resolving small signal measurements in experimental plasma environments using calibrated subtraction of noise signals

The performance of many diagnostic and control systems within fusion and other fields of research are often detrimentally affected by spurious noise signals. This is particularly true for those (such as radiation or particle detectors) working with very small signals. Common sources of radiated and conducted noise in experimental fusion environments include the plasma itself and instrumentation. The noise complicates data analysis, as illustrated by noise on signals measured with the heavy ion beam probe (HIBP) installed on the Madison Symmetric Torus. The noise is time-varying and often exceeds the secondary ion beam current (in contrast with previous applications). Analysis of the noise identifies the dominant source as photoelectric emission from the detectors induced by ultraviolet light from the plasma. This has led to the development of a calibrated subtraction technique, which largely removes the undesired temporal noise signals from data. The advantages of the technique for small signal measurement applications are demonstrated through improvements realized on HIBP fluctuation measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstructing WIMP properties through an interplay of signal measurements in direct detection, Fermi-LAT, and CTA searches for dark matter

We examine the projected ability to reconstruct the mass, scattering, and annihilation cross section of dark matter in the new generation of large underground detectors, XENON-1T, SuperCDMS, and DarkSide-G2, in combination with diffuse gamma radiation from expected 15 years of data from Fermi-LAT observation of 46 local spiral dwarf galaxies and projected CTA sensitivity to a signal from the Galactic Center. To this end we consider several benchmark points spanning a wide range of WIMP mass, different annihilation final states, and large enough event rates to warrant detection in one or more experiments. As previously shown, below some 100 GeV only direct detection experiments will in principle be able to reconstruct WIMP mass well. This may, in case a signal at Fermi-LAT is also detected, additionally help restricting σ v and the allowed decay branching rates. In the intermediate range between some 100 GeV and up a few hundred GeV, direct and indirect detection experiments can be used in complementarity to ameliorate the respective determinations, which in individual experiments can at best be rather poor, thus making the WIMP reconstruction in this mass range very challenging. At large WIMP mass, ∼ 1 TeV, CTA will have the ability to reconstruct mass, annihilation cross section, and the allowed decay branching rates to very good precision for the τ{sup +}τ{sup -} or purely leptonic final state, good for the W {sup +} W {sup -} case, and rather poor for b b-bar . A substantial improvement can potentially be achieved by reducing the systematic uncertainties, increasing exposure, or by an additional measurement at Fermi-LAT that would help reconstruct the annihilation cross section and the allowed branching fractions to different final states.

79 ASTRONOMY AND ASTROPHYSICS↗

Chandra measurements of gas homogeneity and turbulence at intermediate radii in the Perseus Cluster

ABSTRACT We present a Chandra study of surface brightness fluctuations in the diffuse intracluster medium of the Perseus Cluster. Our study utilizes deep, archival imaging of the cluster core as well as a new mosaic of 29 short $\, 5\,$-ks observations extending in eight different directions out to radii of $r_{500} \sim 2.2\, r_{2500}$. Under the assumption that the distribution of densities at a given radius is log-normally distributed, two important quantities can be derived from the width of the log-normal density distribution on a given spatial scale: the density bias, that is equal to the square root of the clumping factor C; and the one-component turbulent velocity, vk,1D. We forward-model all contributions to the measured surface brightness, including astrophysical and particle background components, and account for the Poisson nature of the measured signal. Measuring the distribution of surface brightness fluctuations in 1 arcmin2 regions, spanning the radial range $0.3\rm {-}2.2\, r_{2500}$ ($7.8\rm {-}57.3\,$ arcmin), we find a small to moderate average density bias of around $3{{\ \rm per\ cent}}$ at radii below $1.6\, r_{2500}$. We also infer an average turbulent velocity at these radii of V1D < 400 km s−1. Direct confirmation of our results on turbulent velocities inferred from surface brightness fluctuations should be possible using the X-ray calorimeter spectrometers to be flown aboard the XRISM and Athena observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of glycolytic pathways for inhibiting or measuring oncogenic signaling

Disclosed are methods in which glucose metabolism is correlated to oncogenesis through certain specific pathways; inhibition of certain enzymes is shown to interfere with oncogenic signaling, and measurement of certain enzyme levels is correlated with patient survival. The present methods comprise measuring level of expression of at least one of the enzymes involved in glucose uptake or metabolism, wherein increased expression of the at least one of the enzymes relative to expression in a normal cell correlates with poor prognosis of disease in a patient. Preferably the genes whose expression level is measured include GLUT3, PFKP, GAPDH, ALDOC, LDHA and GFPT2. Also disclosed are embodiments directed towards downregulating the expression of some genes in glucose uptake and metabolism.

59 BASIC BIOLOGICAL SCIENCES↗

Fatigue of extracted lead zirconate titanate multilayer actuators under unipolar high field electric cycling

Testing of large prototype lead zirconate titanate (PZT) stacks presents substantial technical challenges to electronic testing systems, so an alternative approach that uses subunits extracted from prototypes has been pursued. Extracted 10-layer and 20-layer plate specimens were subjected to an electric cycle test under an electric field of 3.0/0.0 kV/mm, 100 Hz to 10{sup 8} cycles. The effects of measurement field level and stack size (number of PZT layers) on the fatigue responses of piezoelectric and dielectric coefficients were observed. On-line monitoring permitted examination of the fatigue response of the PZT stacks. The fatigue rate (based on on-line monitoring) and the fatigue index (based on the conductance spectrum from impedance measurement or small signal measurement) were developed to quantify the fatigue status of the PZT stacks. The controlling fatigue mechanism was analyzed against the fatigue observations. The data presented can serve as input to design optimization of PZT stacks and to operation optimization in critical applications, such as piezoelectric fuel injectors in heavy-duty diesel engines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of a new DIII-D Doppler backscattering system for higher wavenumber measurement and signal enhancement

The high density fluctuation poloidal wavenumber, k θ (k θ > 8 cm –1 , k θ ρ s > 5, ρs is the ion gyro radius using the ion sound velocity), measurement capability of a new Doppler backscattering (DBS) system at the DIII-D tokamak has been experimentally evaluated. In DBS, wavenumber (k) matching becomes more important at higher wavenumbers, owing to the exponential dependence of the measured signal loss factor on wave vector mismatch. Wave vector matching allows for the Bragg scattering condition to be satisfied, which minimizes the signal loss at higher k’s. In the previous DBS system, without toroidal wave vector matching, the measured DBS signal-to-noise ratio at higher k θ (>8 cm –1 ) is substantially reduced, making it difficult to measure higher k θ turbulence. The new DBS system has been optimized to access higher wavenumber, k θ ≤ 20 cm –1 , density turbulence measurement. The optimization hardware addresses fluctuation wave vector matching using toroidal steering of the launch mirror to produce a backscattered signal with improved intensity. The probe’s sensitivity to high-k density fluctuations has been increased by approximately an order of magnitude compared to the old system that has been in use at DIII-D. Note that typical measurement locations are above or below the tokamak midplane on the low field side with normalized radial ranges of 0.5–1.0. As a result, the new DBS probe system with the toroidal matching of fluctuation wave vectors is thought to be critical to understanding high-k turbulent transport in fusion-relevant research at DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bridge-bursting and the action-integral in exploding bridge-wire (EBW) detonators

Methods of simulating the electrical characteristics of exploding bridge-wire detonators using only inert materials are reported. Specifically, it is found that both pressed finely powdered sucrose (confectioners sugar) and 3 µm aluminum oxide powder match the signals measured in a real EBW detonator with PETN fill. The exact pressing density of the inert powder is found not to affect to the measured electrical signals. Additionally, the action-integral (the time integral of bridge current squared) and energy-to-burst are measured for the same gold bridge design with several capacitor discharge units at different charge voltages and inductances as well as pseudo-constant current fireset made from charged coaxial-cables. It is found that in contrast to some reports, the action-integral to burst is not a constant for a specific bridge geometry and material, but instead is a function of the rate of current change in the bridge around the time of burst. This is explained by the confining effects of bridge-wire inertia affecting the rapid expansion of the bridge around burst time and hence the dynamic resistance.

36 MATERIALS SCIENCE↗

Prototypes of self-powered radiation detectors employing intrinsic high-energy current

Purpose: The authors experimentally investigate the effect of direct energy conversion of x-rays via selfpowered Auger- and photocurrent, potentially suitable to practical radiation detection and dosimetry in medical applications. Experimental results are compared to computational predictions. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. This paper focuses on the experiments while a companion paper introduces the fundamental concepts of high-energy current (HEC) detectors. Methods: The energy of ionizing radiation is directly converted to detector signal via electric current induced by high-energy secondary electrons generated in the detector material by the incident primary radiation. The HEC electrons also ionize the dielectric and the resultant charge carriers are selfcollected due to the contact potential of the disparate electrodes. Thus, an electric current is induced in the conductors in two different ways without the need for externally applied bias voltage or amplification. Thus, generated signal in turn is digitized by a data acquisition system. To determine the fundamental properties of the HEC detector and to demonstrate its feasibility for medical applications, the authors used a planar geometry composed of multilayer microstructures. Various detectors with up to seven conducting layers with different combinations of materials (250 μm Al, 35 μm Cu, 100 μm Pb) and air gaps (100 μm) were exposed to nearly plane-parallel 60–120 kVp x-ray beams. For the experimental design and verification, the authors performed coupled electron–photon radiation transport computations. The detector signal was measured using a commercial data acquisition system with 24 bits dynamic range, 0.4 fC sensitivity, and 0.9 ms sampling time. Results: Measured signals for the prototype detector varied depending on the number of layers, material type, and incident photon energy, and it was in the range of 30–150 nA/cm{sup 2} for unit air kerma (1 Gy), which is viable for practical applications. The experiments had an excellent agreement with the computations. Within the examined range of 60–120 kVp, the energy dependence of the HEC (normalized to the x-ray tube output) was relatively small. Conclusions: Based on the experimental results for 100 ms sampling time, it would be possible to measure the time dependence of x-ray beams for x-ray tube current of 0.1 mA or higher. Significant advantages of the HEC device are that generation of its signal does not require external power supply, it can be made in any size and shape, including flexible curvilinear forms, and it is inexpensive. It remains to be determined, which of the potential applications in medical dosimetry (both in vivo and external), or radiation protection would benefit from such selfpowered detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Sampler for Broad-Spectrum Sensing

We investigated the feasibility of using non-uniform optical sampling to measure wide bandwidth RF signals more efficiently. This combined two areas of signal measurement research: optical sampling, which uses optics to alleviate the bandwidth limitations of traditional electronic sampling, and compressed sensing, which seeks to measure signals with fewer samples than typically necessary. This can both increase accuracy and reduce cost over current state-of-the-art sampling devices. However, several different compressed sensing architectures and algorithms offer varying levels of performance, robustness and complexity. In this work, we compared the tradeoffs between several of these methods in simulation of a remote sensing application. We found that while feasible, compressed sensing is inherently less sensitive than fully sampled systems, and so must be paired with a very low noise optical system. We also built an experimental prototype of the system and took initial measurements.

47 OTHER INSTRUMENTATION↗

CGS-MSFSS Project report

From January 2015 to July 2015, I was doing research at Sandia National Laboratories in Albuquerque, United States. My work there consisted of performing experimental measurements using Sandia’s unique silicon quantum computing platform. The project is about coupling donor spin quantum bits, or qubits, to quantum dots in a silicon nanostructure based on conventional microchip technology. During the project, I devised a new quantum state readout mechanism that allow better, longer lived measurement signals. The measurement (or readout) mechanism is key to any qubit architecture. Next, I was able to demonstrate a quantum manipulation of the two-electron spin states of the coupled donor and quantum dot system. This constitutes a breakthrough for donor spin qubits in silicon because it could enable larger systems consisting of many qubits. This project will lead to publications in scientific journals, presentations in international conferences, and generates exciting new opportunities for manipulating nature at the nanoscale.

Harvey-Collard, Patrick↗

Exploiting Spatial Signatures of Power ENF Signal for Measurement Source Authentication

Electric Network Frequency (ENF) signals are the signatures of power systems that are either directly recorded from the power outlets or extracted from multimedia recordings near the electrical activities. Variations of ENF signals collected at different locations possess local environmental characteristics, which can be used as a potential fingerprint for authenticating measurements' source information. Within this paper is proposed a computational intelligence-based framework to recognize the source locations of power ENF signals within a distribution network in the US. To be more specific, a set of informative location-sensitive signatures from ENF measurements are initially extract with such measurements representative of local grid characteristics. Then these distinctive location-dependent signatures are further fed into a data mining algorithm yielding the “source-of-origin” of ENF measurements. Experimental results using ENF data at multiple intra-grid locations have validated the proposed methodology.

CUI, YI↗

Noise reduction methods for nucleic acid and macromolecule sequencing

Methods, systems, and devices are disclosed for processing macromolecule sequencing data with substantial noise reduction. In one aspect, a method for reducing noise in a sequential measurement of a macromolecule comprising serial subunits includes cross-correlating multiple measured signals of a physical property of subunits of interest of the macromolecule, the multiple measured signals including the time data associated with the measurement of the signal, to remove or at least reduce signal noise that is not in the same frequency and in phase with the systematic signal contribution of the measured signals.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of Higgs boson decay into $b$-quarks in associated production with a top-quark pair in $pp$ collisions at $ \sqrt{s} $ = 13 TeV with the ATLAS detector

The associated production of a Higgs boson and a top-quark pair is measured in events characterized by the presence of one or two electrons or muons. The Higgs boson decay into a b-quark pair is used. The analyzed data, corresponding to an integrated luminosity of 139 fb –1 , were collected in proton-proton collisions at the Large Hadron Collider between 2015 and 2018 at a centre-of-mass energy of √s = 13 TeV. The measured signal strength, defined as the ratio of the measured signal yield to that predicted by the Standard Model, is $0.35$ $^{+0.36}_{–0.34}$. This result is compatible with the Standard Model prediction and corresponds to an observed (expected) significance of 1.0 (2.7) standard deviations. The signal strength is also measured differentially in bins of the Higgs boson transverse momentum in the simplified template cross-section framework, including a bin for specially selected boosted Higgs bosons with transverse momentum above 300 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Thermoacoustic Sensors for Sodium-cooled Fast Reactors

This Final Report refers to the project “Development of Thermoacoustic Sensors for Sodium-cooled Fast Reactor Systems”, which was led by Westinghouse Electric Company (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and University of Pittsburgh. Thermo-acoustic Power Sensors (TAPS) are self-powered, wireless sensors envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. This project was intended to specifically investigate their applicability to Sodium-cooled Fast Reactors (SFR). TAPS are non-invasive (wireless) and passive (self-powered) devices. The passivity derives from their ability to use conditions that “naturally” exist in a nuclear reactor, such as gamma and neutron flux, as power sources. They generate oscillating pressure waves (i.e., sound waves) which, with a frequency and amplitude dependent upon these conditions, can travel through the core and associated structures, and reach the outside of the reactor vessel where a properly designed network of receivers can detect and interpret them. These receivers require a very small amount of power which, during loss of power events, can be provided for example by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. The project aimed at TAPS development through a series of tasks which are listed and briefly discussed as follows. TASK 1 – Sensor hardware design Subtask 1a: Assessment of sensor applications to SFRs Subtask 1b: Development of sensor functional requirements Subtask 1c: Definition of sensor hardware design specifications Task description: TAPS design was informed by considerations on their application (Subtask 1a), both the ultimate one in an SFR and the actual one in the ANL testing facilities that was intended to be used in support of the project. Considerations were made to identify optimum sensor design features that optimize the sensor size, materials, and output signal, for installation inside an SFR core. These considerations led to the development of Functional Requirements (Subtask 1b) and Design Requirements (Subtask 1c). TASK 2 – Sensor Hardware Manufacture Subtask 2a: Sensor hardware construction drawing development Subtask 2b: Sensor manufacture and assembly Task description: TAPS technical drawings were developed (Subtask 2a) using the Design Requirements established under Task 1. Subsequently, in spite of some problems which ultimately caused the program to be delayed, TAPS manufacturing was completed based on drawings (Subtask 2b). TASK 3 – Development of TAPS Signal Measurement System and TAPS Testing in Water Subtask 3a: Design, assembly and testing of signal measurement system, and TAPS testing in water Subtask 3b: Signal prediction-correction methodology development Task description: An assessment was performed on the techniques that can potentially be used to detect the signals emitted by the TAPS, e.g. a fiber-optic based acoustic signal measurement system, a laser vibrometer system, or an accelerometer-based system. The most suited technology, i.e. the accelerometer-based system, was developed further, and tested in water (Subtask 3a). Moreover, efforts were made to develop the methodology required to determine the actual system temperature and neutron flux distribution using differences between the measured and predicted TAPS responses (Subtask 3b). TASK 4 – Sensor System Testing in Sodium Subtask 4a: Test plan development Subtask 4b: Design, assembly and testing in small-scale sodium facility Subtask 4c: Design, assembly and testing in large-scale sodium and structures facility Task description: Upon proper test plan development (Subtask 4a), the fabricated TAPS was planned to be tested in sodium, by using two sodium facilities at ANL having different size and different purpose. The Under Sodium Viewing (USV) small-scale facility was intended to be used to investigate the effect of sodium on the sensor and its performance (Subtask 4b). The Mechanism Engineering Test Loop (METL) large-scale facility was instead intended to be used to assess the additional effect of prototypical SFR structures, such as fuel assembly mockup or parts of the core restrain structure, on sensor performance (Subtask 4c). As discussed in Section 3.2.2.7, unexpected issues during the TAPS manufacturing process resulted in some activities being delayed, with the TAPS and USV facility developed to the point to be ready for testing in sodium, however without the possibility to actually perform such testing (including the testing in METL) due to the end of the program’s performance period. Overall, through the development and testing (in water only) of two TAPS devices (a First-Generation TAPS followed by an optimized Second-Generation TAPS), the project confirmed the capability of this technology to generate acoustic signals proportional to temperature, which can be detected through a network of accelerometers identified as the best-suited type of receivers for acoustic signal detection. Moreover, the project also developed a computational model to predict the characteristics of the acoustic signals being generated, which combines thermal analysis of the TAPS with Finite Element Modeling (FEM)-aided acoustic characterization of the system. This model was benchmarked against experimental data collected during the project and, although general agreement was obtained, some limitations of the modeling methods were identified, which require additional development. Additional testing is needed in order to assess the effect, on TAPS operation and performance, of environmental changes resulting from the transition from water to liquid sodium. Such testing, which is suggested to be performed in the future, should look specifically at 1) both the effect resulting from the different thermoacoustic behavior of sodium (relative to water) and the effects of higher temperature on TAPS performance, and 2) the performance of the sensor-receiver system when multiple TAPS are used simultaneously and prototypical reactor structures are positioned in the testing environment. The latter testing is needed to assess the effects that potential signal attenuation/ distortion phenomena, as well as potential interference between signals emitted simultaneously, have on the performance of the technology for ultimate application in a nuclear reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Chiral cavity ring down polarimetry: Chirality and magnetometry measurements using signal reversals

We present the theory and experimental details for chiral-cavity-ring-down polarimetry and magnetometry, based on ring cavities supporting counterpropagating laser beams. The optical-rotation symmetry is broken by the presence of both chiral and Faraday birefringence, giving rise to signal reversals which allow rapid background subtractions. We present the measurement of the specific rotation at 800 nm of vapors of α-pinene, 2-butanol, and α-phellandrene, the measurement of optical rotation of sucrose solutions in a flow cell, the measurement of the Verdet constant of fused silica, and measurements and theoretical treatment of evanescent-wave optical rotation at a prism surface. Therefore, these signal-enhancing and signal-reversing methods open the way for ultrasensitive polarimetry measurements in gases, liquids and solids, and at surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗