Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHOWER COUNTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Observation of Central Exclusive Diphoton Production at the Tevatron

We have observed exclusive γγ production in proton-antiproton collisions at the Tevatron at √ s = 1.96 TeV. We use data corresponding to 1.11 ± 0.07 fb-1 integrated luminosity taken by the Run II Collider Detector at Fermilab, with a trigger requiring two electromagnetic showers, each with transverse energy ET > 2 GeV, and vetoing on hits in the forward beam shower counters. We select events with two electromagnetic showers, each with transverse energy ET > 2.5 GeV and pseudorapidity |η| < 1.0, with no other particles detected in -7.4 < η < +7.4. The two showers have similar ET and an azimuthal angle separation Δφ ~ π; we find 34 events with exactly two matching charged particle tracks, agreeing with expectations for the QED process p¯p → p+e+e- + ¯p by two photon exchange; and we find 43 events with no tracks. The latter are candidates for the exclusive process p¯p → p + γγ + ¯p by double pomeron exchange. We use the strip and wire chambers at the longitudinal shower maximum position within the calorimeter to measure a possible exclusive background from IP + IP → π0π0, and conclude that it is consistent with zero and is < 15 events at 95% C.L. The measured cross section is σγγ,excl(|η| < 1, ET (γ) > 2.5 GeV) = 2.48 +0.40 -0.35(stat) +0.40 -0.51(syst) pb and in agreement with the theoretical predictions. This process is closely related to exclusive Higgs boson production pp → p + H + p at the Large Hadron Collider. The observation of the exclusive production of diphotons shows that exclusive Higgs production can happen and could be observed with a proper experimental setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting Diffraction at the LHC

Forward spectrometers and leading proton detectors--when combined with the powerful mainstream experiments at the LHC--will open up unparalleled physics opportunities in detecting complete high energy collision events in extreme conditions. The range of physics that will be accessed is huge: the small angle extensions of the ATLAS and CMS will effectively transform the LHC into a laboratory of gluon jets, deeply inelastic scattering and novel phenomena not accessed so far in any other experiment. A rapidity gap physics program of a superb potential can be realized at the LHC by adding a few simple forward shower counters (FSCs) along the beam line on both sides of the CMS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diffractive and Exclusive Production at the Tevatron

Exclusive Higgs production, in which the event consists of nothing but the leading protons and a Higgs boson, has been proposed as a channel in which to study the properties of the Higgs boson at the Large Hadron Collider (LHC). Although we do not expect to observe exclusive Higgs-boson production at the Tevatron, we can observe similar processes which provide a calibration for theoretical predictions of exclusive Higgs production at the LHC. The CDF measurements of exclusive dijet and diphoton production, examples of such processes, are presented in Sec. 2. Single diffraction has been studied extensively at the Tevatron in Run I, including diffractive dijet and W/Z-boson production. New results with extended kinematical reach allowed by the larger Run II dataset are presented in Sec. 3. CDF II includes forward detectors designed for studying diffractive physics. The MiniPlug calorimeters cover the pseudorapidity region 3.5<|{eta}|<5.1. Beam Shower Counters (BSC) surrounding the beampipe in several locations detect particles in the forward region 5.4<|{eta}|<7.4. A spectrometer consisting of three Roman-pot detectors preceded by Tevatron dipoles is used to track diffractive antiprotons which have lost a fraction 0.03<{zeta}<0.10 of the beam momentum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BROADBAND, TIME-DEPENDENT, SPECTROSCOPY OF THE BRIGHTEST BURSTS OBSERVED BY BATSE LAD AND EGRET TASC

The Energetic Gamma Ray Experiment Telescope (EGRET) calorimeter, Total Absorption Shower Counter (TASC), was triggered by the Burst And Transient Source Experiment (BATSE) and thus observed several bursts in the energy range of 1-200 MeV. The analysis of combined BATSE Large Area Detector and EGRET TASC data have been developed and discussed previously. Spectroscopy of GRB941017 based on this analysis uncovered an MeV component that would be hidden in the brightness of the synchrotron component in a time-integrated spectrum of the whole burst, while separation into shorter time intervals allowed a unique identification of a new component different from the synchrotron component. In this paper the spectral temporal evolution of the 68 brightest long BATSE bursts, in the broadest energy range yet reported, is studied using the analysis used for GRB941017. We consider the Band function to describe the spectra from keV to MeV energies. Only 21 of the 68 bursts showed MeV emission detectable by TASC. We observed three bursts that contained spectra with peak energy E {sub peak}>2 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small angle detectors for study diffractive processes with CMS

The approach and detectors for diffractive physics based on two current projects—Forward Shower Counter (FSC) and Proton Precision Spectrometer (PPS) are presented. FSC system consists of six (3+3) Stations of scintillator counters, which surround closely the beam pipes along 59 m < |z| < 140 m from IP5 on both plus (+) and minus (-) sides. These will detect showers from very forward particles with rapidity 7.5 < |η| < 10 interacting in the beam pipe and surrounding material. FSC allow measurements of single diffraction: p+p → p+G+X (where G is rapidity gap) for lower masses and double diffraction p+p → X+G+X with a large central rapidity gap. The counters can also be used for beam real-time monitoring and will make an invaluable contribution to the understanding of the background environment and its topology. PPS is designed for study the central exclusive production pp → p+X+p, where the + signs denote the absence of hadronic activity (that is, the presence of a rapidity gap) between the outgoing protons and the decay products of the central system X. The precise measurement of the kinematical parameters of the outgoing protons enables to study the properties of the central state X. In PPS part we consider the detector for high precision timing of these protons—QUARTIC. It consists of L-shape bars with quartz or sapphire radiator. The time resolution of the QUARTIC prototypes achieved ≈ 10 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electron catcher (EC) of SciBooNE

In this paper we describe the electromagnetic calorimeter of the SciBooNE experiment. First we will give some technical details and then we will describe the response of this detector to electrons and muons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Detectors: Research and Development at CERN

Over the past 15 years a worldwide Detector R and D Programme has made the LHC experiments possible. These experiments operate at a new level of event rate and detection capabilities. Based on these advances, Detector R and D is continuing at CERN in close collaboration with University and Research Institutes. Several main directions are being pursued for solid-state and gaseous tracking devices, advanced crystal and noble liquid calorimetry, particle identification methods, and advanced signal-processing techniques. This effort is directed towards experiments at even higher collision rates at the LHC, the requirements for the next generation of linear electron-positron colliders and for applications outside particle physics, such as medical diagnostics instrumentation. We shall illustrate this challenging, stimulating and creative programme with examples and show how these developments are taking place in close collaboration between CERN and institutions around the globe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The status of the AGILE GRB observations and the noticeable case of GRB 080514B

Since Summer 2007, the AGILE mission is successfully detecting and localizing Gamma Ray Bursts by using its wide-field hard X-ray monitor SuperAGILE (17-60 keV) and its CsI Minicalorimeter (0.3-20 MeV). Moreover, all the events with a known localization in the field of view of the Gamma Ray Imaging Detector are searched for in the 30 MeV-50 GeV energy range. Among the several bursts occurred in the field of view of the Gamma Ray Imaging Detector during more than one year of operations, at the time of writing the remarkable GRB 080514B is detected at high significance and GRB 080721 and GRB 081001 are detected at low significance. GRB 080514B is the first Gamma Ray Burst showing a significant emission above 20 MeV after EGRET, and the first ever associated with an afterglow, measured at X-rays and in the IR/Optical/UV. Significant upper limits are derived for the other GRBs. In this paper we report about the status and the scientific performances of the AGILE instrumentation in the study of GRBs and we discuss the properties of GRB 080514B in the context of the long Gamma Ray Bursts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High Resolution Phoswich Detector: LaBr{sub 3}(Ce) Coupled With LaCl{sub 3}(Ce)

An innovative solution for the forward end-cap CALIFA calorimeter of R{sup 3}B is under investigation consisting of two scintillation crystals, LaBr{sub 3} and LaCl{sub 3}, stacked together in a phoswich configuration with one readout only. This dispositive should be capable of a good determination of the energy of protons and gamma radiation. This composite detector allows to deduce the initial energy of charged particles by DELTAE1+DELTAE2 identification. For gammas, the simulations show that there is a high probability that the first interaction occurs inside the scintillator at few centimeters, with a second layer, the rest of the energy is absorbed, or it can be used as veto event in case of no deposition in the first layer. One such a detector has been tested at the Centro de MicroAnalisis de Materiales (CMAM) in Madrid. Good resolution and time signal separation have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LuAG:Ce fibers for high energy calorimetry

The main objective of this contribution is to point out the potentialities of cerium doped LuAG single crystal as pixels and fibers. We first show that after optimization of growth conditions using Bridgman technology, this composition exhibits very good performances for scintillating applications (up to 26 000 photons/MeV). When grown with the micropulling down technology, fiber shapes can be obtained while the intrinsic performances are preserved. For the future high energy experiments requiring new detector concepts capable of delivering much richer informations about x- or gamma-ray energy deposition, unusual fiber shaped dense materials need to be developed. We demonstrate in this frame that cerium doped LuAG is a serious candidate for the next generation of ionizing radiation calorimeters.

36 MATERIALS SCIENCE↗