Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHIELDING MATERIALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Material Open Test Assembly Specimen Retrieval from Hanford's Shielded Material Facility

Hanford’s 324 Building, the Shielded Material Facility (SMF), was developed to provide containment for research and fabrication development studies on highly radioactive metallic and ceramic nuclear reactor fuels and structural materials. Between 1983 and 1992, the SMF was used in support of the Department of Energy (DOE)-funded Fast Flux Test Facility (FFTF) Materials Open Test Assembly (MOTA) program. In this program, metallurgical specimens were irradiated in FFTF and then sent to SMF for processing and storage in two cabinets. This effort was abruptly ended in early 1990s due to programmatic shifts within the DOE, leaving many specimens unexamined. In recent years, these specimens have become of high value to new DOE programs. Pacific Northwest National Laboratory (PNNL) was tasked with retrieving specimens from one of the cabinets in support of fuel clad and duct development for the Advanced Fuel Cycle Initiative. Cesium contamination of the cell and failure of the overhead crane system utilized for opening the cabinets prevented PNNL from using the built-in hot cell equipment to gain access to the cabinets. PNNL designed and tested a lifting device to fit through a standard 10 inch diameter mechanical manipulator port in the SMF South Cell wall. The tool was successfully deployed in June 2008 with the support of Washington Closure Hanford.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cosmic Ray Interactions in Shielding Materials

This document provides a detailed study of materials used to shield against the hadronic particles from cosmic ray showers at Earth’s surface. This work was motivated by the need for a shield that minimizes activation of the enriched germanium during transport for the MAJORANA collaboration. The materials suitable for cosmic-ray shield design are materials such as lead and iron that will stop the primary protons, and materials like polyethylene, borated polyethylene, concrete and water that will stop the induced neutrons. The interaction of the different cosmic-ray components at ground level (protons, neutrons, muons) with their wide energy range (from kilo-electron volts to giga-electron volts) is a complex calculation. Monte Carlo calculations have proven to be a suitable tool for the simulation of nucleon transport, including hadron interactions and radioactive isotope production. The industry standard Monte Carlo simulation tool, Geant4, was used for this study. The result of this study is the assertion that activation at Earth’s surface is a result of the neutronic and protonic components of the cosmic-ray shower. The best material to shield against these cosmic-ray components is iron, which has the best combination of primary shielding and minimal secondary neutron production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-523: Investigation of Various MR-Compatible Shielding Materials for Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer Treatment

Purpose: To evaluate various shielding materials such as Gold (Au), Osmium (Os), Tantalum (Ta), and Tungsten (W) based alloys for use with a novel intensity modulation capable direction modulated brachytherapy (DMBT) tandem applicator for image guided cervical cancer HDR brachytherapy. Methods: The novel MRI-compatible DMBT tandem, made from nonmagnetic tungsten-alloy rod with diameter of 5.4 mm, has 6 symmetric peripheral holes of 1.3 mm diameter with 2.05 mm distance from the center for a high degree intensity modulation capacity. The 0.3 mm thickness of bio-compatible plastic tubing wraps the tandem. MCNPX was used for Monte Carlo simulations of the shields and the mHDR Ir-192 V2 source. MC-generated 3D dose matrices of different shielding materials of Au, Os, Ta, and W with 1 mm3 resolution were imported into an in-house-coded inverse optimization planning system to evaluate 19 clinical patient plans. Prescription dose was 15Gy. All plans were normalized to receive the same HRCTV D90. Results: In general, the plan qualities for various shielding materials were similar. The OAR D2cc for bladder was very similar for Au, Os, and Ta with 11.64±2.30Gy. For W, it was very close 11.65±2.30Gy. The sigmoid D2cc was 9.82±2.46Gy for Au and Os while it was 9.84±2.48Gy for Ta and W. The rectum D2cc was 7.44±3.06Gy for Au, 7.43±3.07Gy for Os, 7.48±3.05Gy for Ta, and 7.47±3.05Gy for W. The HRCTV D98 and V100 were very close with 16.37±1.87 Gy and 97.37±1.93 Gy, on average, respectively. Conclusion: Various MRI-compatible shielding alloys were investigated for the DMBT tandem applicator. The clinical plan qualities were not significantly different among these various alloys, however. Therefore, the candidate metals (or in combination) can be used to select best alloys for MRI image guided cervical cancer brachytherapy using the novel DMBT applicator that is capable of unprecedented level of intensity modulation.

60 APPLIED LIFE SCIENCES↗

Transmission of broad W/Rh and W/Al (target/filter) x-ray beams operated at 25-49 kVp through common shielding materials

Purpose: To provide transmission data for broad 25-39 kVp (kilovolt peak) W/Rh and 25-49 kVp W/Al (target/filter, W-tungsten, Rh-rhodium, and Al-aluminum) x-ray beams through common shielding materials, such as lead, concrete, gypsum wallboard, wood, steel, and plate glass. Methods: The unfiltered W-target x-ray spectra measured on a Selenia Dimensions system (Hologic Inc., Bedford, MA) set at 20-49 kVp were, respectively, filtered using 50-{mu}m Rh and 700-{mu}m Al, and were subsequently used for Monte Carlo calculations. The transmission of broad x-ray beams through shielding materials was simulated using Geant4 low energy electromagnetic physics package with photon- and electron-processes above 250 eV, including photoelectric effect, Compton scattering, and Rayleigh scattering. The calculated transmission data were fitted using Archer equation with a robust fitting algorithm. Results: The transmission of broad x-ray beams through the above-mentioned shielding materials was calculated down to about 10{sup -5} for 25-39 kVp W/Rh and 25-49 kVp W/Al. The fitted results of {alpha}, {beta}, and {gamma} in Archer equation were provided. The {alpha} values of kVp Greater-Than-Or-Slanted-Equal-To 40 were approximately consistent with those of NCRP Report No. 147. Conclusions: These data provide inputs for the shielding designs of x-ray imaging facilities with W-anode x-ray beams, such as from Selenia Dimensions.

36 MATERIALS SCIENCE↗

Neutronics Analysis of Shielding Material Alternative to Tungsten Carbide in the FESS-FNSF Facility

Neutron transport calculations have been performed on advanced shielding materials. Metal hydrides and borohydrides were evaluated to find an alternative to tungsten carbide (WC), which is used in the in-vessel components. The study was conducted using a 22.5° sector and a detailed 360° geometry of the Fusion Energy System Studies-Fusion Nuclear Science Facility (FESS-FNSF) using OpenMC and FENDL-3.2b nuclear data library. Here, the neutronics analysis in this article was concentrated on calculating total nuclear (neutron and photon) heating at the magnet and the radiation damage of the inboard vacuum vessel (IBVV). For example, yttrium hydride (YH 2 ) and vanadium hydride (VH 2 ) showed lower radiation damage values compared to WC and other metals. Whereas alternative shielding materials did not show a significant change in the magnet nuclear heating.

36 MATERIALS SCIENCE↗

Warpage-Resistant, Under-Extrusion-Free, High-Surface-Quality Additive Manufacturing Process for Polyethylene-Based Composite Radiation Shielding Material

Polyethylene (PE) is one of the best shielding materials for primary space radiation due to its high hydrogen content. For effective secondary neutron shielding, boron-rich fillers are incorporated to enhance performance. The semicrystalline nature and high thermal expansion coefficient of PE impede its adoption for in situ additive manufacture in space via the fused deposition modeling (FDM) 3D printing. Here, we developed an optimized PE blend to mitigate the effects of under-extrusion and warpage. Guided by studies on extrusion and warpage, we developed an optimal set of printing parameters for the proposed PE blend. The optimum PE blend─both in its pure form and when doped with fillers─has been tested on different FDM printers. The printed structures exhibit high and uniform density, smooth surfaces, no warpage, and competitive mechanical properties. The FDM-printed plates demonstrate efficient shielding from thermal neutrons, predicted via modeling and confirmed experimentally using extended Q-range small-angle neutron scattering.

additive manufacturing↗

Update of the nuclear criticality slide rule calculations: studies with common shielding materials - 25467

This paper presents preliminary results from the third phase of the current update to the nuclear criticality slide rule, in which MCNP, MAVRIC/Monaco, and COG have simulated the prompt neutron and photon dose from critical spheres of 4.95% enriched uranyl fluoride solution and 93.2% enriched uranium metal. New to this phase is the inclusion of various thicknesses of lead, steel, concrete, and water shielding. This phase also evaluated the effects of humidity on the unshielded configurations in the first phase, as well as the effects of changing the ground composition used in the first phase from concrete to dry soil. The small sample of results presented show that MCNP, MAVRIC/Monaco, and COG results are statistically the same or different by only a few percent. The impact of the shielding materials depends on their thickness, but doses decreased by nearly a factor of 100 are presented. In a few instances, buildup of gamma doses occurs due to neutron interactions in shielding materials. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimizing non-Pb radiation shielding materials using bilayers

Purpose: The objective of this study was to demonstrate that the weight of non-Pb radiation shielding materials can be minimized by structuring the material as a bilayer composed of different metal-powder-embedded elastomer layers. Methods: Measurements and Monte Carlo (MC) calculations were performed to study the attenuation properties of several non-Pb metal bilayers over the x-ray energy range 30-150 keV. Metals for the layers were chosen on the basis of low cost, nontoxicity, and complementary photoelectric absorption characteristics. The EGSnrc user code cavity.cpp was used to calculate the resultant x-ray fluence spectra after attenuation by these metal layers. Air kerma attenuation was measured using commercially manufactured metal/elastomer test layers. These layers were irradiated using the primary standard calibration beams at the Institute for National Measurement Standards in Ottawa, Canada utilizing the six x-ray beam qualities recommended in the German Standard DIN 6857. Both the measurements and the calculations were designed to approximate surface irradiation as well as penetrating radiation at 10 mm depth in soft tissue. The MC modeling point and the position of the measurement detector for surface irradiation were both directly against the downstream face of the attenuating material, as recommended in DIN 6857. Results: The low-Z upstream/high-Z downstream ordering of the metal bilayers provided substantially more attenuation than the reverse order. Optimal percentages of each metal in each bilayer were determined for each x-ray radiation beam quality. Conclusions: Depending on the x-ray quality, appropriate choices of two complementary metal-embedded elastomer layers can decrease the weight of radiation shielding garments by up to 25% compared to Pb-based elastomer garments while providing equivalent attenuation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo simulation of photon buildup factors for shielding materials in diagnostic x-ray facilities

Purpose: A simulation of buildup factors for ordinary concrete, steel, lead, plate glass, lead glass, and gypsum wallboard in broad beam geometry for photons energies from 10 keV to 150 keV at 5 keV intervals is presented. Methods: Monte Carlo N-particle radiation transport computer code has been used to determine the buildup factors for the studied shielding materials. Results: An example concretizing the use of the obtained buildup factors data in computing the broad beam transmission for tube potentials at 70, 100, 120, and 140 kVp is given. The half value layer, the tenth value layer, and the equilibrium tenth value layer are calculated from the broad beam transmission for these tube potentials. Conclusions: The obtained values compared with those calculated from the published data show the ability of these data to predict shielding transmission curves. Therefore, the buildup factors data can be combined with primary, scatter, and leakage x-ray spectra to provide a computationally based solution to broad beam transmission for barriers in shielding x-ray facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Shielding Material in Radioactive Waste Management - 13009

In this study, various waste packages have been prepared by using different materials. Experimental work has been performed on radiation shielding for gamma and neutron radiation. Various materials were evaluated (e.g. concrete, boron, etc.) related to different application areas in radioactive waste management. Effects of addition boric compound mixtures on shielding properties of concrete have been investigated for neutron radiation. The effect of the mixture addition on the shielding properties of concrete was investigated. The results show that negative effects of boric compounds on the strength of concrete decreasing by increasing boric amounts. Shielding efficiency of prepared mixture added concrete up to 80% better than ordinary concretes for neutron radiation. The attenuation was determined theoretically by calculation and practically by using neutron dose rate measurements. In addition of dose rate measurements, strength tests were applied on test shielding materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Printing of electromagnetic interference shielding materials

Here, the proliferation of electronic devices has made electromagnetic interference (EMI) shielding an exponentially growing business. Regulatory requirements change constantly as new technologies continue to emerge. Innovations in materials and new advances in shielding implementation techniques are needed to pass regulatory compliance tests at an affordable cost. Here, we print various EMI shielding materials such as copper, silver and a composite of copper with Fe 3 O 4 using plasma jet printing. Printing enables shields only a few microns thick capable of high shielding effectiveness. Copper's EMI shielding performance is primarily contributed by reflection mechanism, as expected and this is known to cause secondary pollution. A Green Index for EMI shielding, given by the ratio of absorption and reflection contributions to shielding, indicates values lower than 0.1 for printed copper films.

36 MATERIALS SCIENCE↗

Characterization of shielding materials used in neutron scattering instrumentation

The nuclear cross-sections of certain isotopes make some materials excellent candidates for neutron shielding. We have performed a series of measurements examining the transmission, reflection, and nuclear Bragg scattering of a series of common materials used for neutron shielding. Here, we concentrate on characterizing the materials most likely to be used in neutron scattering instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron radiation shielding material polyethylene: consequences of gamma irradiation - 15062

High and ultra-high molecular weight polyethylenes are high performance materials, which are predestined for a wide range of applications due to characteristics like high density, low weight, good dimensional stability, high chemical resistance, and high hydrogen content. These polymers are used in two demanding areas: as implant material in medical technology (only ultra-high molecular weight polyethylenes) and as a component for neutron shielding purposes in casks for storage and transport of radioactive waste. In the medical field (joint replacements) as well as during neutron radiation shielding application, high and ultra-high molecular weight polyethylenes are exposed to gamma irradiation: in the first case requested as sterilization process and for surface-crosslinking and in the second case existing as a side effect of inserting the radioactive material in the cask. Given that polyethylene as shielding material has to withstand any type of degradation affecting safety relevant aspects to be applicable for long-term radiation shielding purposes for instance over a period of 40 years, the durability of the material is of special interest. High molecular weight polyethylene (HMW-PE; LUPOLEN 5261Z; Lyondell Basell) and ultra-high molecular weight polyethylene (UHMW-PE; GUR 4120; Ticona) were subjected to gamma radiation and afterwards thermally treated. The gamma doses used are in the range of 50 to 600 kGy and irradiation takes place at RT using a Co-60 source. The planned thermal treatment will take place at a temperature of 125 deg.C for periods of minimum 30 days and maximum of five years. With the applied conventional analytical techniques it is possible to detect structural changes of both types of polyethylene induced by gamma irradiation and certainly of thermal treatment. Through gamma irradiation melting temperature, crystallinity, and density, respectively increased. Furthermore both polyethylenes get oxidized and cross-linked. With regard to the special application as neutron radiation shielding material in casks for storage and transport of radioactive materials, the impact of irradiation lead to changes of material properties. A consolidated view indicates that the detected changes of the irradiated (U)HMW-PE are not safety relevant for long-term neutron radiation shielding purposes over a period of 40 years in Germany. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multiplication and Presence of Shielding Material from Time-Correlated Pulse-Height Measurements of Subcritical Plutonium Assemblies

Here, we present the results from the first measurements of the Time-Correlated Pulse-Height (TCPH) distributions from 4.5 kg sphere of α-phase weapons-grade plutonium metal in five configurations: bare, reflected by 1.27 cm and 2.54 cm of tungsten, and 2.54 cm and 7.62 cm of polyethylene. A new method for characterizing source multiplication and shielding configuration is also demonstrated. The method relies on solving for the underlying fission chain timing distribution that drives the spreading of the measured TCPH distribution. We found that a gamma distribution fits the fission chain timing distribution well and that the fit parameters correlate with both multiplication (rate parameter) and shielding material types (shape parameter). The source-to-detector distance was another free parameter that we were able to optimize, and proved to be the most well constrained parameter. MCNPX-PoliMi simulations were used to complement the measurements and help illustrate trends in these parameters and their relation to multiplication and the amount and type of material coupled to the subcritical assembly.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Identification of Shielding Material Configurations Using NMIS Imaging

The Nuclear Materials Identification System (NMIS) uses fast neutron tomographic imaging to nonintrusively examine the interior structure of shielded objects. The pixel values in such images represent the attenuation coefficients of the time and directionally tagged fast neutrons from a deuterium-tritium (DT) neutron generator. The reconstruction techniques use either a filtered back projection or a maximum likelihood expectation maximization algorithm. As a first test of the capabilities of these reconstruction techniques to correctly identify individual parts inside of an object, fast neutron imaging was used to identify the regions of shielding surrounding a depleted uranium casting from a library of possible parts. The shielding consisted of multiple regions of common materials such as steel, lead, aluminum, and polyethylene. First, the full object was imaged, and then each of the individual parts was imaged. Several additional parts that were not present in the original object were also imaged to form a library. The individual parts were compared to the full object, and the correct ones were identified using three different methods. These methods included a visual match, an iterative fit of each part, and a mathematical test comparing the sum of squared errors. The successful results demonstrate an initial application of matching. This suggests that it should be possible to implement more sophisticated matching techniques using automated pixel-by-pixel comparison methods in the future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Elastomer Heat-Shielding Materials Containing Aluminosilicate Microspheres

The influence of hollow aluminosilicate microspheres on the efficiency of elastomeric thermoprotective materials based on ethylene—propylene rubber is considered. The introduction of hollow aluminosilicate microspheres, even in small quantities, decreases the density and heat conductivity of such materials, with no loss of physical and mechanical properties.

36 MATERIALS SCIENCE↗

Monte Carlo simulation of photon buildup factors for shielding materials in radiotherapy x-ray facilities

Purpose: This paper presents the results of a series of calculations to determine buildup factors for ordinary concrete, baryte concrete, lead, steel, and iron in broad beam geometry for photons energies from 0.125 to 25.125 MeV at 0.250 MeV intervals.Methods: Monte Carlo N-particle radiation transport computer code has been used to determine the buildup factors for the studied shielding materials.Results: The computation of the primary broad beams using buildup factors data was done for nine published megavoltage photon beam spectra ranging from 4 to 25 MV in nominal energies, representing linacs made by the three major manufacturers. The first tenth value layer and the equilibrium tenth value layer are calculated from the broad beam transmission for these nine primary megavoltage photon beam spectra.Conclusions: The results, compared with published data, show the ability of these buildup factor data to predict shielding transmission curves for the primary radiation beam. Therefore, the buildup factor data can be combined with primary, scatter, and leakage x-ray spectra to perform computation of broad beam transmission for barriers in radiotherapy shielding x-ray facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Olive bagasse and nutshell as gamma shielding material

Gamma ray linear attenuation coefficients have been measured experimentally for olive bagasse and nutshell by using narrow beam geometry for Co-60 and the values have been compared with soil. These values have been used calculate mean free path, half value layer and tenth value layer parameters. Besides, effect of multi-layered systems (soil + olive bagasse and soil + nutshell) has been analyzed in terms of half value layer.

54 ENVIRONMENTAL SCIENCES↗