Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SERI QC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Developing the Proof of Concept for the SERI QC Flag Translation

SERI QC is a robust solar data quality assessment software tool that has been in continuous use for more than three decades. This report, the second of six in the Data Quality and Uncertainty Integration project, develops the proof of concept, including programming in C and a collection of spreadsheet tools, for estimating the operational uncertainty from three-component solar irradiance measurements using information available from SERI QC. The report establishes a field reference for determining the operational uncertainty for each irradiance component based on the SERI QC coupling. Results demonstrate that the operational uncertainty estimates based on global irradiance best represent the collective results for all sky conditions.

14 SOLAR ENERGY↗

Evaluation and Suitability of Using SERI QC Software for Estimating Measurement Uncertainty

SERI QC is a robust solar data quality assessment software tool that has been in continuous use for more than three decades. This report (the first of six in the Data Quality and Uncertainty Integration project) reviews and evaluates the software to determine its suitability for determining the estimated expanded measurement uncertainty of solar measurement data by including operational factors. Using redundancy incorporated in three-component (global, direct, diffuse) solar measurements, SERI QC can quantify the standard uncertainty estimates for estimating uncertainty. With minor modifications, SERI QC will provide an operational uncertainty to be used in conjunction with the National Renewable Energy Laboratory method for instrument uncertainty to provide an integrated estimate of solar measurement data sets. These modifications will capitalize on SERI QC's evaluation of data quality, including data input validation and a variety of built-in solar routines, and will further develop the utility of the software.

14 SOLAR ENERGY↗

A Refined Method to Translate Solar Data Quality Assessment Flags to Estimated Measurement Uncertainty

Integrating solar resource uncertainties due to radiometer measurement performance and operational data quality assessment can provide improved estimates of economic bankability, system design performance, and compliance of solar energy conversion systems. Estimating radiometer measurement uncertainty is an established procedure consistent with recognized best practices and international guidelines. SERI QC is a robust solar data quality assessment software tool that has been in continuous use for more than three decades. This report, the fourth of six for the Data Quality and Uncertainty Integration Project, presents a refined algorithm description for software to translate solar resource data quality assessment results into estimated uncertainty values in a Solar Resource Operational Uncertainty Integrator (SROUI) application. This algorithm requires three-component solar irradiance measurements - global horizontal irradiance, direct normal irradiance, and diffuse horizontal irradiance - collected at 1- to 60-minute intervals, as described in the previous deliverables. The development of this report as Deliverable 6.4 was an iterative process that included reviews and feedback from the project team on initial drafts designed to refine how the new software could best support determining solar resource data uncertainty. The results of this effort will contribute to the final software system development by National Renewable Energy Laboratory staff.

14 SOLAR ENERGY↗

Solar Radiometer Instrumentation Evaluation: Cooperative Research and Development (Final Report, CRADA Number CRD-16-00619)

The purpose and intent of this agreement is to evaluate newly manufactured thermopile pyranometers and spectroradiometers. The purpose also extends to provide a framework for Participant to conduct research to improve and develop new radiometric devices and application in the future. The overall objective is to provide more accurate, site-specific, long-term, continuous measurements of the solar resources needed by industry to increase the deployment and improve the operations of photovoltaic and concentrating solar power plants. This CRADA addresses the needs for proven solar irradiance measurement to validate resource assessment models and generate high quality data used for site selection, energy system design, deployment, maintenance, and operation. This work will be conducted at NREL and Participant facilities. This project will place instrumentation at the NREL Solar Radiation Research Laboratory (SRRL) in cooperation with EKO Instruments, USA. Participant instruments will be deployed for the purpose of evaluation under controlled conditions. The scope of the project will be a 3 years-long segmented comparison of the instruments vs. other NREL baseline instruments with a well-characterized history. These evaluations will include planned improvements to instruments as well as extensions of future instrument applications. The final evaluation will be a written report similar to the work done by Wilcox and Myers (see http://www.nrel.gov/docs/fy09osti/44627.pdf).

14 SOLAR ENERGY↗

Solar Resource Measurements in Eugene, OR: Cooperative Research and Development Final Report, CRADA Number CRD-07-00252

Site-specific, long-term, continuous, and high-resolution measurements of solar irradiance are important for developing renewable resource data. These data are used for several research and development activities consistent with the NLR mission: establish a national 3-year climatological database of measured solar irradiances; provide high quality ground-truth data for satellite remote sensing validation; support development of radiative transfer models for estimating solar irradiance from available meteorological observations; provide solar resource information needed for technology deployment and operations. Data acquired under this agreement will be available to the public through NLR's Measurement & Instrumentation Data Center – MIDC (http://www.nlr.gov/midc) Or the Renewable Resource Data Center - RReDC (http://rredc.nlr.gov). The MIDC offers a variety of standard data display, access, and analysis tools designed to address the needs of a wide user audience (e.g., industry, academia, and government interests).

14 SOLAR ENERGY↗

Silicon strip defects and their impact on electrical performance of readout electronics

Abstract In preparation for the High Luminosity LHC (HL-LHC) runs, the ATLAS inner detector will be completely replaced with an all silicon Inner Tracker (ITk). Hybrid silicon pixel modules will be used for the innermost tracking layers, and silicon micro-strip detectors will be used the outer layers of the tracker. During the production of the detector, the sensors, readout electronics, and other components will undergo a series of quality control (QC) and quality assurance tests. Defects in the fabrication of the sensors will be flagged early in the manufacturer's and ATLAS QC tests. A study of the influence of sensor defects was performed to assess the characteristics of these defects in completed modules, and whether any defect posed a risk to the operation of the front-end readout electronics. All defects were found to have no impact on the performance of the front-end readout electronics for healthy amplifier channels, and defects that short the coupling between the strip implant and the metal readout electrode were only noticeable for strip leakage currents in excess of 250 nA, beyond the end-of-life currents expected for most sensors at the HL-LHC.

Instruments & Instrumentation↗

Silicon pinhole strip defects and their impact on ATLAS Inner Tracker HV current measurement

In preparation for the High-Luminsity LHC (HL-LHC) [1], the ATLAS detector will undergo major detector upgrades, including the replacement of the current Inner Detector with the new all-silicon Inner Tracker (ITk) [2]. The ITk consists of a pixel detector close to the beamline surrounded by a large-area strip detector. During detector production, the electrical properties of silicon sensors and readout electronics must be characterized through a series of quality control (QC) and quality assurance tests. These tests ensure any defect is captured at the earliest possible stage. One such defect, callled a pinhole, occurs when the strip implant and the metal readout electrode are shorted through the intermediary dielectric layer. Notably, the introduction of pinholes during module assembly and pinhole effects on completed modules, especially on leakage current measurement circuitry, have never been studied. In this paper, we investigate the effect of such connections on the sensor leakage current measurements of completed modules and introduce new ways to locate pinholed strips. Here, with minor modifications to testing procedures, such defects are shown not to impede module testing or performance.

FOS: Physical sciences↗

Ongoing quality control in digital radiography: Report of AAPM Imaging Physics Committee Task Group 151

Quality control (QC) in medical imaging is an ongoing process and not just a series of infrequent evaluations of medical imaging equipment. The QC process involves designing and implementing a QC program, collecting and analyzing data, investigating results that are outside the acceptance levels for the QC program, and taking corrective action to bring these results back to an acceptable level. The QC process involves key personnel in the imaging department, including the radiologist, radiologic technologist, and the qualified medical physicist (QMP). The QMP performs detailed equipment evaluations and helps with oversight of the QC program, the radiologic technologist is responsible for the day-to-day operation of the QC program. The continued need for ongoing QC in digital radiography has been highlighted in the scientific literature. The charge of this task group was to recommend consistency tests designed to be performed by a medical physicist or a radiologic technologist under the direction of a medical physicist to identify problems with an imaging system that need further evaluation by a medical physicist, including a fault tree to define actions that need to be taken when certain fault conditions are identified. The focus of this final report is the ongoing QC process, including rejected image analysis, exposure analysis, and artifact identification. These QC tasks are vital for the optimal operation of a department performing digital radiography.

60 APPLIED LIFE SCIENCES↗

Quality-Controlled Meteorological Data from the Flood Control District of Maricopa County (FCDMC) Network, Phoenix, Arizona (1987-2024)

This dataset contains 15- or 30-minute interval meteorological data from the Flood Control District of Maricopa County (FCDMC), Arizona, USA, covering eight key variables across multiple sensor stations between 1987 and 2024. Each variable is stored as a separate CSV file, containing time-series data that have undergone rigorous quality control (QC) procedures and, where appropriate, short-gap interpolation for consistency. The quality control (QC) pipeline consisted of four sequential tests: (1) a range test to ensure all values fall within physically realistic limits, (2) a step test to identify abrupt and implausible changes between consecutive records, (3) a proximity test that validates flagged values from step test using data from nearby stations and exceedance probability thresholds, and (4) a persistence test to detect and remove periods of unrealistically constant readings. These thresholds were calibrated to Arizona’s environmental conditions and sensor specifications. After QC, short gaps (≤2 hours) were linearly interpolated to ensure consistent temporal resolution, except for wind variables. Due to a major upgrade in FCDMC’s data transmission system, only ALERT-2 protocol data (2016–2024) for wind variables are included; earlier ALERT-1 data were excluded because of irregular sampling and high missing rates. This dataset supports regional climate and infrastructure resilience studies by providing standardized, high-resolution meteorological data for the greater Phoenix metropolitan area.

54 ENVIRONMENTAL SCIENCES↗

Quality Assurance and Quality Control (QA/QC) of Meteorological Time Series Data for Billy Barr, East River, Colorado USA

A comprehensive Quality Assurance (QA) and Quality Control (QC) statistical framework consists of three major phases: Phase 1—Preliminary raw data sets exploration, including time formatting and combining datasets of different lengths and different time intervals; Phase 2—QA of the datasets, including detecting and flagging of duplicates, outliers, and extreme values; and Phase 3—the development of time series of a desired frequency, imputation of missing values, visualization and a final statistical summary. The time series data collected at the Billy Barr meteorological station (East River Watershed, Colorado) were analyzed. The developed statistical framework is suitable for both real-time and post-data-collection QA/QC analysis of meteorological datasets.The files that are in this data package include one excel file, converted to CSV format (Billy_Barr_raw_qaqc.csv) that contains the raw meteorological data, i.e., input data used for the QA/QC analysis. The second CSV file (Billy_Barr_1hr.csv) is the QA/QC and flagged meteorological data, i.e., output data from the QA/QC analysis. The last file (QAQC_Billy_Barr_2021-03-22.R) is a script written in R that implements the QA/QC and flagging process. The purpose of the CSV data files included in this package is to provide input and output files implemented in the R script.

54 ENVIRONMENTAL SCIENCES↗

Putative quantum criticality in the (Cr{sub 90}Ir{sub 10}){sub 100−y}V{sub y} alloy system

Quantum criticality (QC) in spin-density-wave antiferromagnetic Cr and Cr alloy systems is a topic of current interest. In the present study, V was used as a tuning parameter to drive the Néel transition temperature (T{sub N}) of the (Cr{sub 90}Ir{sub 10}){sub 100−y}V{sub y} alloy series with 0 ≤ y ≤ 14.3 to zero and search for effects of QC in the process. The magnetic properties and possible QC behaviour (QCB) in this alloy system were investigated through electrical resistivity (ρ), specific heat (C{sub p}), and susceptibility (χ) measurements as a function of temperature (T), indicating that T{sub N} is suppressed to zero at a critical concentration y{sub c} ≈ 9. The Sommerfeld coefficient (γ) is considered a key indicator of QCB and a peak is observed in γ(y) at y{sub c} on decreasing y through this concentration, followed by a sharp decreasing trend. This behaviour is reminiscent of that observed for γ of the prototypical Cr{sub 100−x}V{sub x} QC system and allows for the classification of y{sub c} in the (Cr{sub 90}Ir{sub 10}){sub 100−y}V{sub y} alloy system as a possible QC point.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Challenging problems of quality assurance and quality control (QA/QC) of meteorological time series data

Abstract Representativeness and quality of collected meteorological data impact accuracy and precision of climate, hydrological, and biogeochemical analyses and predictions. We developed a comprehensive Quality Assurance (QA) and Quality Control (QC) statistical framework, consisting of three major phases: Phase I—Preliminary data exploration, i.e., processing of raw datasets, with the challenging problems of time formatting and combining datasets of different lengths and different time intervals; Phase II—QA of the datasets, including detecting and flagging of duplicates, outliers, and extreme data; and Phase III—the development of time series of a desired frequency, imputation of missing values, visualization and a final statistical summary. The paper includes two use cases based on the time series data collected at the Billy Barr meteorological station (East River Watershed, Colorado), and the Barro Colorado Island (BCI, Panama) meteorological station. The developed statistical framework is suitable for both real-time and post-data-collection QA/QC analysis of meteorological datasets.

54 ENVIRONMENTAL SCIENCES↗

Total metals, sulfur and organic carbon data; Slate River floodplain, Crested Butte, CO; March 2021-October 2021

This data package includes processed and undiluted measurements for metal, sulfur and organic carbon concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between March and October of 2021. These measurements were all recorded at the Environmental Measurements Facility (EM-1) at Stanford University in Stanford, CA. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 2C until measured at EM-1.Analysis by ICP-MS:Measurements for total metals were performed on an inductively coupled plasma optical emission spectrometer (ICP-OES; iCAP 6300, Thermo Scientific, Cambridge, U.K.). Calibration standards were prepared from the mulit element stock solution (Sigma-Aldrich Multielement standard for ICP, St. Louis, MO) using matrix matched to sample solutions (2% HNO3). Calibration curves included 5 points with correlation coefficients of >0.99. The QC protocol includes a continuing calibration blank and quality control samples that are analyzed just after calibration and again every 20 samples and at the completion of the run. Acceptable QC responses must be between 90-110% of the certified value. Analysis by Total Organic Carbon:Dissolved organic carbon concentrations were quantified on a total organic carbon (TOC) analyzer (TOC-L, Shimadzu, Kyoto, Japan) running the NPOC method. Standard curves were developed using an Organic Carbon Standard from RICCA Chemical Company (Arlington,TX). A series of 4 to 6 standards were automatically diluted by the instrument in a concentration range that spans that of the samples. A blank sample was run just after the calibration curve and at the end of the run. A QC sample was run every 25 samples. Acceptable QC responses must be between 90-110% of the certified value.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

The Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating conversion of negative muons into electrons in the coulomb field of an Al nucleus, planning to reach a single event sensitivity of about $3\cdot10^{−17}$, four orders of magnitude beyond the current best limit.The conversion electron has a clear monoenergetic signature at 104.967 MeV, slightly below the muon rest mass, and will be identified by a complementary measurement carried out by a high-resolution tracker and an electromagnetic calorimeter (EMC). The calorimeter is composed of 1348 pure CsI crystals, each read by two custom UV-extended SiPMs, that are arranged in two annular disks. The EMC should achieve better than 10% energy resolution and 500 ps timing resolution for 100 MeV electrons and maintain extremely high levels of reliability and stability and in a harsh operating environment with high vacuum, 1 T B-field and radiation exposures up to 100 krad and $10^{12} \rm{n}_\rm{1MeVeq}/\rm{cm}^{2}$.The calorimeter technological choice, along with the design of the custom front-end electronics, cooling and mechanical systems were validated through an electron beam test on a large-scale 51-crystals prototype (Module-0) and extensive test campaigns that characterised and verified the performance of crystals, photodetectors, analogue and digital electronics. This included hardware stress tests and irradiation campaigns with neutrons, protons, and photons.The production and QC phases of all calorimeter components is completed apart for the digital electronics that has been revised for improving its resilience to SEU and SEL. A series of vertical slice tests with the final electronics is being carried out on the Module-0 at LNF along with the implementation and validation of the calibration procedures. The first disk has been assembled in 2022 while the second disk is under assembly at the moment of writing. Status of construction will be summarised, along with plans for commissioning and first calibration of the fully assembled disks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy transfer networks: Quasicontinuum photoluminescence linked to high densities of defects

In a series of studies related to laser-induced damage of optical materials and deposition of plastics, we discovered a broadly emitting photoluminescence with fast lifetimes that we termed quasicontinuum photoluminescence (QC-PL). Here in this paper, we suggest that a high density of optically active defects leads to QC-PL, where interactions between defects affect the temporal and spectral characteristics of both excitation and emission. We develop a model that predicts the temporal characteristics of QC-PL, based on energy transfer interactions between high densities of defects. Our model does not explain all spectral broadening and redshifts found in QC-PL, since we do not model spectral changes in defects due to proximity to other defects. However, we do provide an example of a well-defined system that exhibits the QC-PL characteristics of a distribution in shortened lifetimes and broadened, redshifted energy levels: an organic chromophore (fluorescein) that has been dried rapidly on a fused silica surface. Recently, we showed that regions of fused silica exposed to up to 1 billion high-fluence laser shots at 351 rm nm at subdamage fluences exhibit significant transmission losses at the surface. Here, we find that these laser-exposed regions also exhibit QC-PL. Increases in the density of induced defects on these laser-exposed surfaces, as measured by the local transmission loss, lead to decreases in the observed lifetime and redshifts in the spectrum of the QC-PL, consistent with our explanation for QC-PL. In conclusion, we have found QC-PL in an increasing variety of situations and materials, and we believe it is a phenomenon commonly found on surfaces and nanostructured materials.

36 MATERIALS SCIENCE↗