Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SENSOR BIASES EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High temporal resolution estimates of Arctic snowfall rates emphasizing gauge and radar-based retrievals from the MOSAiC expedition

This article presents the results of snowfall rate and accumulation estimates from a vertically pointing 35-GHz radar and other sensors deployed during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition. The radar-based retrievals are the most consistent in terms of data availability and are largely immune to blowing snow. The total liquid-equivalent accumulation during the snow accumulation season is around 110 mm, with more abundant precipitation during spring months. About half of the total accumulation came from weak snowfall with rates less than approximately 0.2 mmh–1. The total snowfall estimates from a Vaisala optical sensor aboard the icebreaker are similar to those from radar retrievals, though their daily and monthly accumulations and instantaneous rates varied significantly. Compared to radar retrievals and the icebreaker optical sensor data, measurements from an identical optical sensor at an ice camp are biased high. Blowing snow effects, in part, explain differences. Weighing gauge measurements significantly overestimate snowfall during February–April 2020 as compared to other sensors and are not well suited for estimating instantaneous snowfall rates. The icebreaker optical disdrometer estimates of snowfall rates are, on average, relatively little biased compared to radar retrievals when raw particle counts are available and appropriate snowflake mass-size relations are used. These counts, however, are not available during periods that produced more than a third of the total snowfall. While there are uncertainties in the radar-based retrievals due to the choice of reflectivity-snowfall rate relations, the major error contributor is the uncertainty in the radar absolute calibration. The MOSAiC radar calibration is evaluated using comparisons with other radars and liquid water cloud–drizzle processes observed during summer. Overall, this study describes a consistent, radar-based snowfall rate product for MOSAiC that provides significant insight into Central Arctic snowfall and can be used for many other purposes.

54 ENVIRONMENTAL SCIENCES↗

Projection-Based Constrained Fusion Performance with Link Loss and Measurement Bias

Sensor networks have been deployed in many real-world applications for tracking and monitoring of dynamic targets over large geographical areas. We consider a scenario where a number of ground and/or airborne sensors are used to jointly track a ground target with certain constraints on its motion dynamics, such as those defined by roadways. The state estimates from these sensors are sent over a lossy communications network to a remote fusion center for fusion. We propose both centralized and distributed projection-based methods to incorporate known constraints into the estimation and fusion process. In addition to presenting simple closed-form projected fusion solutions, we also show how to utilize knowledge of the constraints into the fusion process by two distance-based weighting methods. Wealso explore the effect of link loss and sensor measurement bias on tracking accuracy performance of constrained fusion using illustrative tracking examples. Performance evaluation results demonstrate the potential of adopting weighted average fusers in improving the overall tracking performance in the presenceof link loss and measurement bias.

Liu, Qiang↗

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

Planar Hall effect bridge magnetic field sensors

Until now, the planar Hall effect has been studied in samples with cross-shaped Hall geometry. We demonstrate theoretically and experimentally that the planar Hall effect can be observed for an exchange-biased ferromagnetic material in a Wheatstone bridge topology and that the sensor signal can be significantly enhanced by a geometric factor. For the samples in the present study, we demonstrate an enhancement of the sensor output by a factor of about 100 compared to cross-shaped sensors. The presented construction opens a new design and application area of the planar Hall effect, which we term planar Hall effect bridge sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Consequences of CCD imperfections for cosmology determined by weak lensing surveys: from laboratory measurements to cosmological parameter bias

Weak gravitational lensing causes subtle changes in the apparent shapes of galaxies due to the bending of light by the gravity of foreground masses. By measuring the shapes of large numbers of galaxies (millions in recent surveys, up to tens of billions in future surveys) we can infer the parameters that determine cosmology. Imperfections in the detectors used to record images of the sky can introduce changes in the apparent shapes of galaxies, which in turn can bias the inferred cosmological parameters. In this paper we consider the effect of two widely discussed sensor imperfections: tree rings, due to impurity gradients that cause transverse electric fields in the charge-coupled devices (CCDs), and pixel size variation, due to periodic CCD fabrication errors. These imperfections can be observed when the detectors are subject to uniform illumination (flat-field images). We develop methods to determine the spurious shear and convergence (due to the imperfections) from the flat-field images. We calculate how the spurious shear when added to the lensing shear will bias the determination of cosmological parameters. We apply our methods to candidate sensors of the Large Synoptic Survey Telescope (LSST) as a timely and important example, analyzing flat-field images recorded with LSST prototype CCDs in the laboratory. We find that tree rings and periodic pixel size variation present in the LSST CCDs will introduce negligible bias to cosmological parameters determined from the lensing power spectrum, specifically w, Ω{sub m}, and σ{sub 8}.

79 ASTRONOMY AND ASTROPHYSICS↗

Can We Rely on Satellite Visible/Infrared Microphysical Retrievals of Boundary Layer Clouds in Partially Cloudy Scenes? Implications for Climate Research

This study addresses the longstanding question of the reliability of gridded visible/infrared satellite cloud properties in partially cloudy scenes. By using in-situ cloud probes and airborne Research Scanning Polarimeter (RSP) observations, we analyze bias changes in satellite retrievals from the Spinning Enhanced Visible Infra-Red Imager (SEVIRI) geostationary sensor during the ORACLES campaign. Biases in cloud optical depth (τ) and droplet effective radius (r e ) modestly change for cloud area fraction greater than 35%. The agreement between SEVIRI and RSP r e substantially improves when the retrievals are averaged after removing pixels with τ < 3.0, yielding biases indistinguishable from overcast scenes. In addition, satellite and RSP show an excellent agreement for closed- and open-cell stratocumulus clouds, showing that the satellite retrievals capture spatial changes of r e , and confirming that satellites can faithfully reproduce real physical features for optically thick and partially cloudy scenes. We demonstrate that a simple methodology can minimize uncertainties in satellite-based climate studies.

Painemal, David [NASA Langley Research Center, Ham↗

Ultra-high speed burst-mode imager for multi-frame radiography

A 720 x 720 pixel hybrid-CMOS imager was fabricated by Rockwell Scientific (now Teledyne Imaging Sensors). Several cameras have been in operation for 5 years, in a variety of static and dynamic experiments, at the 800MeV proton radiography (pRAD) facility at the LANSCE accelerator. The cameras can operate with a per-pulse adjustable inter-frame time of 250ns to 2s, and with an exposure/integration-time as short as 150 ns. Given the 800 ms total readout time, the imager can be externally synchronized to 0.1-to-5Hz, 50-ns wide proton beam pulses, and record 1000-frame radiographic movies of 5-to-30 minute duration. The effectiveness and dependence of the global electronic shutter on the pixelated Si photo-sensor bias voltage is discussed. The spatial resolution dependence of the full imaging system on various monolithic and structured scintillators is presented. We also present features of a new-generation 10-frame, 1024 x 1024 pixel, 50-ns exposure, 12-bit dynamic range imager, which is now in the design phase.

47 OTHER INSTRUMENTATION↗

Quantum resonance of nanometre-scale metal-ZnO-metal structure and its application in sensors

Analysis of the thickness dependence of the potential profile of the metal-ZnO-metal (MZM) structure has been conducted based on Poisson’s equation and Schottky theory. Quantum scattering theory is then used to calculate the transmission probability of an electron passing through the MZM structure. Results show that the quantum resonance (QR) effect becomes pronounced when the thickness of the ZnO film reaches to around 6 nm. Strain induced piezopotentials are considered as biases to the MZM, which significantly changes the QR according to the analysis. This effect can be potentially employed as nanoscale strain sensors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evidence of Dopant Type-Inversion and Other Radiation Damage Effects of the CDF Silicon Detectors

The aim of this document is to study the effect of radiation damage on the silicon sensors. The reflection of the effect of radiation can be observed in two fundamental parameters of the detector: the bias current and the bias voltage. The leakage current directly affects the noise, while the bias voltage is required to collect the maximum signal deposited by the charged particle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of deposition rate and ion energy distribution in a pulsed dc magnetron sputtering system using a retarding field analyzer with embedded quartz crystal microbalance

A compact retarding field analyzer with embedded quartz crystal microbalance has been developed to measure deposition rate, ionized flux fraction, and ion energy distribution arriving at the substrate location. The sensor can be placed on grounded, electrically floating, or radio frequency (rf) biased electrodes. A calibration method is presented to compensate for temperature effects in the quartz crystal. The metal deposition rate, metal ionization fraction, and energy distribution of the ions arriving at the substrate location are investigated in an asymmetric bipolar pulsed dc magnetron sputtering reactor under grounded, floating, and rf biased conditions. The diagnostic presented in this research work does not suffer from complications caused by water cooling arrangements to maintain constant temperature and is an attractive technique for characterizing a thin film deposition system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of intrinsic magnetostriction on tube-topology magnetoelectric sensors with high magnetic field sensitivity

Three quasi-one-dimensional magnetoelectric (ME) magnetic field sensors, each with a different magnetostrictive wire material, were investigated in terms of sensitivity and noise floor. Magnetostrictive Galfenol, iron-cobalt-vanadium, and iron-nickel wires were examined. Sensitivity profiles, hysteresis effects, and noise floor measurements for both optimally biased and zero-biased conditions are presented. The FeNi wire (FN) exhibits high sensitivity (5.36 mV/Oe) at bias fields below 22 Oe and an optimal bias of 10 Oe, whereas FeGa wire (FG) exhibits higher sensitivity (6.89 mW/Oe) at bias fields >22 Oe. The sensor of FeCoV wire (FC) presents relatively low sensitivity (2.12 mV/Oe), due to low magnetostrictive coefficient. Each ME tube-topology sensor demonstrates relatively high sensitivity at zero bias field, which results from a magnetic shape anisotropy and internal strain of the thin magnetostrictive wire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A multi-prong approach towards the development of high performance Temperature sensor using MWCNTs/Al2O3 composite film

Highlights: • MWCNTs/Al{sub 2}O{sub 3} composite based self-standing highly sensitive temperature sensor. • Optimization of film thickness to achieve best performance of the device. • Effect of carrier drift under strong electron-phonon coupling is examined. • Non-contact measurements reveal possibilities of ambient environment monitoring. • Highly stable and reproducible response bidding commercial scale production. - Abstract: We report fabrication of high-performance temperature sensor from free-standing MWCNTs/Al{sub 2}O{sub 3} composite film where a multi-prong approach was undertaken to enhance sensor performance. Film thickness was varied until a threshold value was reached by playing surface-area to volume-ratio factor leading to enormous improvements in crucial sensor parameters–temperature coefficient of resistance (TCR) and thermal hysteresis. Increased TCR resulted in high sensitivity, ultrafast response and negligible hysteresis loss. Besides, effect of carrier-drift transport under strong electron-phonon scattering is investigated by permutation of channel-length and external DC bias. Observed TCR value is −0.96%/°C for 16.53 μm thick film, at 2 V applied-bias voltage for 1 mm channel-length. Moreover, the sensor exhibited negligible hysteresis loss along-with response and recovery times of ∼40 s and ∼185 s respectively. Non-contact mode temperature measurements also demonstrated excellent performance. Fabricated sensors exhibited good stability and negligible drift for six-months. These studies are significant towards fabricating simple, highly-sensitive, economic heat sensor with high reproducibility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary benchmarks and analysis of boundary conditions in a trenched microstructured silicon radiation detector

Microstructured neutron detectors have the benefit of enhanced neutron detection efficiency as compared to planar devices, achieved by etching 6 LiF-filled trenches on the top surface of a silicon PIN diode. This sensor geometry results in a complex electric field distribution and depletion characteristics within the diode under reverse bias. For the first time on record, the effects of a fixed oxide charge on the microstructured device depletion characteristics and mobile carrier transport is investigated. Prototype detectors were fabricated with non-conformal surface doping. Capacitance voltage and current voltage measurements were performed for these prototypes and compared with COMSOL Multiphysics simulations. A spectral response from an 241Am alpha particle source was acquired and analyzed. It was found that monoenergetic alpha particles produce three prominent peaks in the pulse height spectrum output by the device. The peaks were confirmed by simulations to correlate with dead layers and incident trajectories into the microstructure. It was also found that significant differences in pulse rise time result, corresponding with events arriving in a low-field region in the fins and a high-field region in the bulk. Geant4 was utilized for radiation transport, interaction modeling, and benchmarking the spectral data. The results of this simulation work provide confidence in the ability to attain and benchmark electrical characteristics and spectral data for semiconductor radiation detectors employing complex microstructures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Langmuir probes for SPIDER (source for the production of ions of deuterium extracted from radio frequency plasma) experiment: Tests in BATMAN (Bavarian test machine for negative ions)

A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors’ holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Low-Power and In Situ Annealing Mitigation Technique for Fast Neutrons Irradiation of Integrated Temperature Sensing Diodes

High doses of fast neutrons is detrimental to the performance of most common solid-state devices such as diodes and transistors. The ionizing effect is observed in particular for diodes used as simple integrated temperature sensors, or thermo-diodes, when their junction voltage is measured at constant current bias. In this work, we present a low-power and in situ mitigation technique based on Silicon-on-Insulator (SOI) micro-hot-plates to recover thermo-diodes. The basic operating principle consists in annealing the temperature-sensitive diodes integrated on the membrane during or after their irradiation in order to restore similar sensing characteristics over time. We measured thermo-diodes integrated to micro-hot-plates during their irradiation by fast neutrons (23 MeV peak) with total doses about 2.97±0.08 kGy. The membrane annealing is taking place at 450 deg. C using 40 mW of electrical power. Thanks to the annealing, the diode keeps a total measurement error below 0.5 deg. C. In this harsh radiation environment and beside the good tolerance of the thermo-diodes and the membrane materials to the total ionizing dose, the thermo-diode located on the heating membrane keeps a constant sensitivity. The demonstrated resistance of micro-hot-plates and the integrated thermo-diodes to fast neutron radiations can extend their use in nuclear plants and for radiation detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carrier behavior in special multilayer device composed of different transition metal oxide-based intermediate connectors

The impact of illumination on the connection part of the tandem organic light-emitting diodes was studied by using a special organic multilayer sample consisted of two organic active layers coupled with different transition metal oxide (TMO)-based intermediate connectors (ICs). Through measuring the current density-voltage characteristic, interfacial electronic structures, and capacitance-voltage characteristic, we observe an unsymmetrical phenomenon in current density-voltage and capacitance-voltage curves of Mg:Alq{sub 3}/MoO{sub 3} and MoO{sub 3} composed devices, which was induced by the charge spouting zone near the ICs region and the recombination state in the MoO{sub 3} layer. Moreover, Mg:Alq{sub 3}/MoO{sub 3} composed device displays a photovoltaic effect and the V{sub oc} shifts to forward bias under illumination. Our results demonstrate that the TMO-based IC structure coupled with photovoltaic effect can be a good approach for the study of photodetector, light sensor, and so on.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fundamental Piezotronic and Piezo-phototronic Effects in Nanowires

The piezo-phototronic effect is about the use of the piezoelectric potential created inside some materials for enhancing the charge carrier generation or separation at the metal-semiconductor contact or p-n junction. We demonstrate the impact of the piezo-phototronic effect on the photon sensitivity for a ZnO-CdS core-shell micro/nanowire based visible and UVsensor. CdS nanowire arrays were grown on the surface of a ZnO micro/nanowire to form a ZnO-CdS core-shell nanostructure by a facile hydrothermal method. With the two ends of a ZnO-CdS wire bonded on a polymer substrate, a flexible photodetector was fabricated, which is sensitive simultaneously to both green light (548 nm) and UV light (372 nm). The photocurrent and sensitivity of the ZnO_CdS wire photodetector is 103 times higher than that of CdS nanoribbon, and the responsivity (11 A W -1 , 548 nm, at 2 V bias) is nearly 100 times higher than that of ZnSe-nanobelt-based blue/UV-light sensor (0.12 AW -1 , 400 nm, at 30 V bias). Moreover, the performance of the ZnO-CdS wire photodetector upon illumination of visible and UV light can be both further enhanced for more than 10 times with the participation of the piezo-phototronic effect when the device is subjected to a -0.31% compressive strain. This investigation extends the application of the piezo-phototronic effect in a wide spectrum photon detector.

14 SOLAR ENERGY↗