Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hardness assurance for proton direct ionization-induced SEEs using a high-energy proton beam

The low-energy proton energy spectra of all shielded space environments have the same shape. This shape is easily reproduced in the laboratory by degrading a high-energy proton beam, producing a high-fidelity test environment. We use this test environment to dramatically simplify rate prediction for proton direct ionization effects, allowing the work to be done at high-energy proton facilities, on encapsulated parts, without knowledge of the IC design, and with little or no computer simulations required. Proton direct ionization (PDI) is predicted to significantly contribute to the total error rate under the conditions investigated. Scaling effects are discussed using data from 65-nm, 45-nm, and 32-nm SOI SRAMs. These data also show that grazing-angle protons will dominate the PDI-induced error rate due to their higher effective LET, so PDI hardness assurance methods must account for angular effects to be conservative. As a result, we show that this angular dependence can be exploited to quickly assess whether an IC is susceptible to PDI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Under-Constrained SEE Data: Implications for Estimating and Bounding SEE Rates

Increasingly scarce SEE testing resources and rapid growth of the New Space sector have increased the prevalence of under-constrained SEE data. We develop Monte Carlo tools to assess implications for SEE rate estimation. We also show that Bayesian Priors based on large datasets of SEL susceptible parts can augment under-constrained data and improve bounds on SEL rates. The resulting Bayesian Priors are also useful for bounding system SEL risk.

Single-event effect↗

Use of Proton SEE Data as a Proxy for Bounding Heavy-Ion SEE Susceptibility

Although heavy-ion single-event effects (SEE) pose serious threats to semiconductor devices in space, many missions face difficulties testing such devices at heavy-ion accelerators. Low-cost missions often find such testing too costly. Even well funded missions face issues testing commercial off the shelf (COTS) due to packaging and integration. Some missions wish to fly COTS systems with little insight into their components. Heavy-ion testing such parts and systems requires access to expensive and hard-to-access ultra-high energy ion accelerators, or significant system modification. To avoid these problems, some have proposed using recoil ions from high-energy protons as a proxy to bound heavy-ion SEE rates.

reliability estimation↗

Relaxation dynamics in see-saw shaped Dy( iii ) single-molecule magnets

Unusual see-saw shaped Dy( iii ) single-molecule magnets, [K(DME) n ][L Ar Dy(X) 2 ] (L Ar = {C 6 H 4 [(2,6- i PrC 6 H 3 )NC 6 H 4 ] 2 } 2− ), X = Cl ( 1 ) and X = I ( 2 ) were synthesized and display high effective energy barriers ( U eff = 1278–1334 K) in zero field.

Harriman, Katie L. M.↗

Seeing the invisible: Direct visualization of therapeutic radiation beams using air scintillation

Purpose: To assess whether air scintillation produced during standard radiation treatments can be visualized and used to monitor a beam in a nonperturbing manner. Methods: Air scintillation is caused by the excitation of nitrogen gas by ionizing radiation. This weak emission occurs predominantly in the 300–430 nm range. An electron-multiplication charge-coupled device camera, outfitted with an f/0.95 lens, was used to capture air scintillation produced by kilovoltage photon beams and megavoltage electron beams used in radiation therapy. The treatment rooms were prepared to block background light and a short-pass filter was utilized to block light above 440 nm. Results: Air scintillation from an orthovoltage unit (50 kVp, 30 mA) was visualized with a relatively short exposure time (10 s) and showed an inverse falloff (r{sup 2} = 0.89). Electron beams were also imaged. For a fixed exposure time (100 s), air scintillation was proportional to dose rate (r{sup 2} = 0.9998). As energy increased, the divergence of the electron beam decreased and the penumbra improved. By irradiating a transparent phantom, the authors also showed that Cherenkov luminescence did not interfere with the detection of air scintillation. In a final illustration of the capabilities of this new technique, the authors visualized air scintillation produced during a total skin irradiation treatment. Conclusions: Air scintillation can be measured to monitor a radiation beam in an inexpensive and nonperturbing manner. This physical phenomenon could be useful for dosimetry of therapeutic radiation beams or for online detection of gross errors during fractionated treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A matter of collection and detection for intraoperative and noninvasive near-infrared fluorescence molecular imaging: To see or not to see?

Purpose: Although fluorescence molecular imaging is rapidly evolving as a new combinational drug/device technology platform for molecularly guided surgery and noninvasive imaging, there remains no performance standards for efficient translation of “first-in-humans” fluorescent imaging agents using these devices. Methods: The authors employed a stable, solid phantom designed to exaggerate the confounding effects of tissue light scattering and to mimic low concentrations (nM–pM) of near-infrared fluorescent dyes expected clinically for molecular imaging in order to evaluate and compare the commonly used charge coupled device (CCD) camera systems employed in preclinical studies and in human investigational studies. Results: The results show that intensified CCD systems offer greater contrast with larger signal-to-noise ratios in comparison to their unintensified CCD systems operated at clinically reasonable, subsecond acquisition times. Conclusions: Camera imaging performance could impact the success of future “first-in-humans” near-infrared fluorescence imaging agent studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Do You See What I See? Exploring the Consequences of Luminosity Limits in Black Hole–Galaxy Evolution Studies

In studies of the connection between active galactic nuclei (AGNs) and their host galaxies, there is widespread disagreement on some key aspects of the connection. These disagreements largely stem from a lack of understanding of the nature of the full underlying AGN population. Recent attempts to probe this connection utilize both observations and simulations to correct for a missed population, but presently are limited by intrinsic biases and complicated models. We take a simple simulation for galaxy evolution and add a new prescription for AGN activity to connect galaxy growth to dark matter halo properties and AGN activity to star formation. We explicitly model selection effects to produce an “observed” AGN population for comparison with observations and empirically motivated models of the local universe. This allows us to bypass the difficulties inherent in models that attempt to infer the AGN population by inverting selection effects. We investigate the impact of selecting AGNs based on thresholds in luminosity or Eddington ratio on the “observed” AGN population. By limiting our model AGN sample in luminosity, we are able to recreate the observed local AGN luminosity function and specific star formation-stellar mass distribution, and show that using an Eddington ratio threshold introduces less bias into the sample by selecting the full range of growing black holes, despite the challenge of selecting low-mass black holes. We find that selecting AGNs using these various thresholds yield samples with different AGN host galaxy properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Eyes can See What Mind Can’t see

A 55 year old Caucasian female with a history of Iron deficiency anemia with hemoglobin of 6.1 gm/dl was admitted from her hematologist office for a Venofer infusion. She had profound confusion on presentation. Physical examination was pertinent for fever of 101οF, and laboratory data pertinent for elevated blood sugars of 590 mg/dl, leukocytosis of 10.3 K/UL with bandemia of 13%, elevated AST 170 U/L, ALT 184 U/L, and normal alkaline phosphate and total bilirubin. She was subsequently found to have Strep. Viridian bacteremia and CT scan of Chestabdomen- pelvis revealed multiple hepatosplenic masses consistent with malignancy or abscesses. Liver biopsy showed benign liver cells with a background of acute and chronic inflammatory cells and abscess (*image shown). She was treated with long term course of Ceftriaxone via PICC line.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Do You See What I See? Interactive Visualization of Mission Design and Navigation

Mission Design and Navigation (MDNav) is an intensive process requiring advanced computational resources, expert human intuition, and many successive human-in-the-loop iterations to converge on acceptable trajectory designs or navigation solutions. The current bottleneck in MDNav is not the underlying computational algorithms but the human cognitive capacity to prune through a multitude of simulated results to select high-value candidates. One approach to alleviate this burden is through the judicious application of visualizations that allow humans to interactively filter data in multiple dimensions to reveal salient patterns and highlight divergences. When designed efficiently, such interactive visualizations should aid human operators to get familiar with data faster, visually observe correlations, and communicate findings more effortlessly. In this work, we present three visualization case studies that have the potential to increase human operator efficiency in MDNav. While identifying the most critical “pain points” that operators face, and also working on potential solutions, we followed a human-centered design approach. We started with a series of interviews with potential users, and then rapidly created prototypes for alternative solutions, validated outcomes with feedback from users through out development of these proof of concept visualizations. With this survey of our current efforts, we demonstrate the transformative capability of interactive data visualizations for improving mission development and operations, enabling operators to grow intuition, and communicating key concepts across diverse mission teams.

Arora, Nitin↗

From LDEF to a national Space Environment and Effects (SEE) program: A natural progression

As the LDEF program draws to a close, it leaves in place the fundamental building blocks for a Space Environment and Effects (SEE) program. Results from LDEF data analyses and investigations now form a substantial core of knowledge on the long term effects of the space environment on materials, system and structures. In addition, these investigations form the basic structure of a critically-needed SEE archive and database system. An agency-wide effort is required to capture all elements of a SEE program to provide a more comprehensive and focused approach to understanding the space environment, determining the best techniques for both flight and ground-based experimentation, updating the models which predict both the environments and those effects on subsystems and spacecraft, and, finally, ensuring that this multitudinous information is properly maintained, and inserted into spacecraft design programs. Many parts and pieces of a SEE program already exist at various locations to fulfill specific needs. The primary purpose of this program, under the direction of the Office of Advanced Concepts and Technology (OACT) in NASA Headquarters, is to take advantage of these parts; apply synergisms where possible; identify and when possible fill-in gaps; coordinate and advocate a comprehensive SEE program. The SEE program must coordinate and support the efforts of well-established technical communities wherein the bulk of the work will continue to be done. The SEE program will consist of a NASA-led SEE Steering Committee, consisting of government and industry users, with the responsibility for coordination between technology developers and NASA customers; and Technical Working Groups with primary responsibility for program technical content in response to user needs. The Technical Working Groups are as follows: Materials and Processes; Plasma and Fields; Ionizing Radiation; Meteoroids and Orbital Debris; Neutral External Contamination; Thermosphere, Thermal, and Solar Conditions; Electromagnetic Effects; Integrated Assessments and Databases. Specific technology development tasks will be solicited through a NASA Research Announcement to be released in May of 1994. The areas in which tasks are solicited include: (1) engineering environment definitions, (2) environments and effects design guidelines, (3) environments and effects assessment models and databases, and (4) flight/ground simulation/technology assessment data.

Bowles, David E.↗

DESIGN AND TEST OF AN INSTRUMENT FOR MEASURING MICROTHERMAL SEEING ON THE MAGDALENA RIDGE

We have constructed and operated an automated instrument for measuring ground-level microthermal seeing at the Magdalena Ridge Observatory (MRO). The MRO is located at an altitude of 10500' in the Cibola National Forest in New Mexico, USA. It is the planned site for the MRO Optical Interferometer (MROI) planned for up to 10 collecting elements, each with a diameter of 1.4 m, and baselines eventually up to approximately 400 m. As part of the preparation for construction we deployed a system to characterize the ground-level seeing across the observatory site. The instrument is built largely of off-the-shelf components, with only the sensor head and power supply requiring electronic board assembly. Even in those cases the board architecture is very simple. The first proof-of-concept system was deployed for several weeks in the autumn of 2004, and has since undergone several iterations. The latest configuration operates entirely off batteries, incorporates wireless data acquisition, and is thus able to operate in an area with no shelter, power, or communications. In this paper we present the design of the instrument, and show initial data. The microthermal tower has four sensor pairs at heights from 0.8 to 4.41 m, significantly lower than other microthermal experiments, because of the need to characterize the seeing near the ground. We find significant variation in the contribution of this range of heights to the seeing, contributing up to 0.''3 of the seeing at some times and only 0.''02 at other times. The individual sensor power spectra have a slope in the range of 1.4--1.5, which is lower than the 1.67 slope predicted by Kolmogorov turbulence theory. We measure the well known effect of improved seeing immediately around sunset. While we find significant variation in the microthermal seeing, we did not find a pattern of corresponding variations in weather conditions, suggesting that a complicated set of factors control microthermal turbulence.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-event Effect Report for EPC Series eGaN FETs: Proton Testing for SEE and TNID Effects

Previous testing of the Enhanced Power Conversion (EPC) eGaN FETs showed sensitivity to destructive single-event effects (SEE) effects to heavy ions. The presence of tungsten plugs in the gate area raises concerns that the device may be vulnerable to SEE from protons. Irradiation of biased and unbiased devices with heavy ion has results in some damage suspected of being due to total non-ionizing dose (TNID). Proton irradiation is a better radiation type to study this effect. This study presents the results of testing device with protons for SEE and TNID. No SEE in the EPC2012 device, the most sensitive device to SEE, were seen with 53 MeV protons at several angles. The devices continued to function after 1.5 Mrad (Si) of proton dose with only a slight shift in parameters. These results suggest that gross TNID will not be a factor in using these devices nor suffer from SEE due to protons. However, the device should be tested at with 500 MeV protons to guarantee to immunity proton SEE.

Scheick, Leif↗

In-Flight Observations of Long-Term Single Event Effect(SEE)Performance on Orbview-2 and Xray Timing Explorer(XTE)Solid State Recorders (SSR)

This paper presents Single Event Effect (SEE) in-flight data on Solid State Recorders (SSR) that have been collected over a long period of time for two NASA spacecraft: Orbview-2 and XTE. SEE flight data on solid-state memories give an opportunity to study the behavior in space of SEE sensitive commercial devices. The actual Single Event Upset (SEU) rates can be compared with the calculated rates based on environment models and ground test data. The SEE mitigation schemes can also be evaluated in actual implementation. A significant amount of data has already been published concerning observed SEE effects on memories in space. However, most of the data presented cover either a short period of time or a small number of devices. The data presented here has been collected on a large number of devices during several years. This allows statistically significant information about the effect of space weather fluctuations on SEU rates, and the effectiveness of SEE countermeasures used to be analyzed. Only Orbview-2 data is presented in this summary. XTE data will be included in the final paper.

Poivey, Christian↗