At least 19 records

Testing of an Integrated Iodine Scrubber and Polishing Bed System

In 2016 an initial engineering evaluation and design of the off-gas abatement systems required for a hypothetical 1000 t/yr used nuclear fuel (UNF) reprocessing facility treating 5 yr–cooled, 60 GWd/tIHM UNF was completed. In this study two types of silver-based iodine sorbents were considered. The first was a silver-exchanged mordenite (AgZ), and the second was a silver-functionalized silica aerogel. In the initial design of the dissolver off-gas (DOG) iodine capture beds, the sorbent capacity was assumed to be 40 mg I/g sorbent. The total iodine released from the fuel, used as input for the design of the DOG system, was 1.635 kg/day. Tramp halogens increased this to ~5.1 kg/day on an iodine equivalent basis. The daily consumption of iodine sorbent was ~166 kg (including the mass transfer zones that have lower iodine loading). The iodine capture system was designed to utilize five beds in parallel. In this design each bed was ~1 m in diameter and 1.5 m long. This design allowed the beds to remain on line for 20 days, but at that point all five beds would need to be replaced, resulting in considerable material handling. It was proposed that the bed life could be extended and the number of parallel beds reduced if an aqueous iodine scrubber preceded the solid sorbent iodine capture beds. The testing described in this report was intended to provide an evaluation of an integrated system in which bulk iodine would first be removed by an aqueous NaOH scrubber with a target iodine decontamination factor (DF) of 10 to 50. This would reduce the sorbent usage by 90 to 95% and significantly reduce the associated frequent remote handling of the iodine filter beds. The effluent from the scrubber would then be passed through an AgZ sorbent bed to remove residual iodine. The integration of these unit operations was intended to demonstrate an iodine DF of >1000, which would facilitate regulatory compliance with regards to total volatile radionuclide emission from a reprocessing facility. Initial baseline performance testing of the scrubber system includes the characterization of CO 2 removal by the aqueous NaOH scrubber as a function of temperature, caustic concentration, packing length, liquid-to-gas mass ratio, and liquid flow rate. It was found that when the column was well wetted, very high CO 2 DFs were achieved (>650 and potentially as high as 15,000), preventing the ability to elucidate the effects of each specific variable tested. The L/G ratio in this system was not representative of typical L/G ratios found in industrial-scale scrubber systems. By significantly lowering the liquid recirculation rate to the point that column wetting was marginal, some significant variations in the CO 2 DF or CO 2 effluent concentrations could be observed. The additional tests conducted under these more adverse conditions still showed CO 2 DFs >100. The only operational parameter with significant effects was determined to be column length, with increased column length resulting in higher CO 2 DFs. Following these CO 2 tests, a single iodine scrubber test was performed deliberately at a condition indicated by the CO 2 demonstration to result in poor column performance. This was intended to establish a lower performance bound for iodine removal by the aqueous scrubber. The result showed that even under the adverse operating conditions, an iodine DF of >100 could be achieved. Finally, the aqueous scrubber and a AgZ polishing bed were integrated. This simple caustic scrubber system achieved an iodine DF of >12,000 for just the scrubber portion. Using this iodine DF, the iodine loading on the polishing bed was reduced by 99.993%. The performance of that integrated system was compared to a system including only a AgZ sorbent bed. The system without the scrubber also showed iodine DFs >3000 until breakthrough was observed. The loading on the saturated portion of the bed averaged 87.2 mg I 2 /gm AgZ. Comparing the penetration of iodine into the sorbent beds for these two systems showed a marked difference; the penetration with the scrubber was only 0.65 cm at a maximum loading of 0.11 mg I 2 /gm AgZ, whereas for the case without the caustic scrubber, the bed was saturated for the first 7 cm and breakthrough of the 13.3 cm bed occurred.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pilot plant testing of elemental mercury reemission from a wet scrubber

This paper is to discuss the recent observations of elemental mercury (Hg{sup 0}) remission from a pilot-scale limestone wet scrubber. Simulated flue gas was generated by burning natural gas in a down-fired furnace and doped with 2000 ppm of sulfur dioxide (SO{sub 2}). Mercuric chloride (HgCl{sub 2}) solution was delivered to the scrubber at a controlled rate to simulate the absorption of ionized mercury (Hg{sup 2+}). Testing results have shown that, after Hg{sup 2+} was injected, elevated Hg{sup 0} concentrations were soon detected both in the scrubber effluent flue gas and the hold tank air, which reflected the occurrence of Hg{sup 0} reemission in both places. When the HgCl{sub 2} feed was stopped, the Hg{sup 0} reemission continued for more than 2 h. In addition, a significant Hg{sup 0} reemission was also detected outside the scrubber loop. In an attempt to understand the Hg{sup 0} reemission increase across the wet scrubber system under transient and steady states and to understand the underlying relationship with the mercury complexes retained in the wet scrubber system, a mercury reemission model was developed. With this model, it was found that the Hg{sup 0} reemission rate under the current testing conditions can be simulated by a first-order reaction, and only a portion of HgS(IV) complexes retained in the slurry were participating in the reemission reaction. 5 refs., 6 figs., 1 gab.

01 COAL, LIGNITE, AND PEAT↗

Value-Added Products from FGD Sulfite-Rich Scrubber Materials

According to the American Coal Ash Association, about 29.25 million tons of flue gas desulfurization (FGD) byproducts were produced in the USA in 2003. Out of 29.25 million tons, 17.35 million tons were sulfite-rich scrubber materials. At present, unlike its cousin FGD gypsum, the prospect for effective utilization of sulfite-rich scrubber materials is not bright. In fact, almost 16.9 million tons are leftover every year. In our pursuit to mitigate the liability of sulfite-rich FGD scrubber materials' disposal, we are attempting to develop value-added products that can commercially compete. More specifically, for this Innovative Concept Phase I project, we have the following objectives: to characterize the sulfite-rich scrubber material for toxic metals; to optimize the co-blending and processing of scrubber material and natural byproducts; to formulate and develop structural composites from sulfite-rich scrubber material; and to evaluate the composites' mechanical properties and compare them with current products on the market. After successfully demonstrating the viability of our research, a more comprehensive approach will be proposed to take these value-added materials to fruition.

01 COAL, LIGNITE, AND PEAT↗

Separation of Mercury from Flue Gas Desulfurization Scrubber Produced Gypsum

Frontier Geosciences (Frontier; FGS) proposed for DOE Grant No. DE-FG02-07ER84669 that mercury control could be achieved in a wet scrubber by the addition of an amendment to the wet-FGD scrubber. To demonstrate this, a bench-scale scrubber and synthetic flue-gas supply was designed to simulate the limestone fed, wet-desulfurization units utilized by coal-fired power plants. Frontier maintains that the mercury released from these utilities can be controlled and reduced by modifying the existing equipment at installations where wet flue-gas desulfurization (FGD) systems are employed. A key element of the proposal was FGS-PWN, a liquid-based mercury chelating agent, which can be employed as the amendment for removal of all mercury species which enter the wet-FGD scrubber. However, the equipment design presented in the proposal was inadequate to demonstrate these functions and no significant progress was made to substantiate these claims. As a result, funding for a Phase II continuation of this work will not be pursued. The key to implementing the technology as described in the proposal and report appears to be a high liquid-to-gas ratio (L/G) between the flue-gas and the scrubber liquor, a requirement not currently implemented in existing wet-FGD designs. It may be that this constraint can be reduced through parametric studies, but that was not apparent in this work. Unfortunately, the bench-scale system constructed for this project did not function as intended and the funds and time requested were exhausted before the separation studies could occur.

20 FOSSIL-FUELED POWER PLANTS↗

HYDROFLUORIC ACID SCRUBBER SYSTEMS

Each year over a million gallons of water are used to scrub hydrogen fluoride (HP) vapors from waste off-gas streams. Use of other potential scrubber solutions such as potassium hydroxide (KOH), aluminum nitrate nonahydrate (ANN), and monobasic aluminum nitrate (monoban) would result in significant volume reductions. A laboratory study was initiated to (1) demonstrate the effectiveness of these scrubber solutions to sorb HF, (2) determine if unexpected reactions occurred at flowsheet conditions, and (3) determine the consequences of deviation from flowsheet conditions. Caustic or aluminum scrubber solutions remove hydrogen fluoride from off-gas streams. Solids which appear with aluminum could be avoided by heating the scrubber solution.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of a Zirconium Recycle Scrubber System

A hot-cell demonstration of the zirconium recycle process is planned as part of the Materials Recovery and Waste Forms Development (MRWFD) campaign. The process treats Zircaloy® cladding recovered from used nuclear fuel with chlorine gas to recover the zirconium as volatile ZrCl4. This releases radioactive tritium trapped in the alloy, converting it to volatile tritium chloride (TCl). To meet regulatory requirements governing radioactive emissions from nuclear fuel treatment operations, the capture and retention of a portion of this TCl may be required prior to discharge of the off-gas stream to the environment. In addition to demonstrating tritium removal from a synthetic zirconium recycle off-gas stream, the recovery and quantification of tritium may refine estimates of the amount of tritium present in the Zircaloy cladding of used nuclear fuel. To support these objectives, a bubbler-type scrubber was fabricated to remove the TCl from the zirconium recycle off-gas stream. The scrubber was fabricated from glass and polymer components that are resistant to chlorine and hydrochloric acid solutions. Because of concerns that the scrubber efficiency is not quantitative, tests were performed using DCl as a stand-in to experimentally measure the scrubbing efficiency of this unit. Scrubbing efficiency was ~108% ± 3% with water as the scrubber solution. Variations were noted when 1 M NaOH scrub solution was used, values ranged from 64% to 130%. The reason for the variations is not known. It is recommended that the equipment be operated with water as the scrubbing solution. Scrubbing efficiency is estimated at 100%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Process optimization of caustic scrubber and iodine-129 immobilization in sodalite-based waste forms

Caustic scrubbers are proposed to remove vaporized iodine from nuclear fuel reprocessing plants. Resulting caustic slurries of radioactive iodine ( 129 I) and other anions can be captured and immobilized into the cage structures of sodalite-type minerals. Here, mixed anion sodalites were hydrothermally synthesized from a simulated caustic scrubber solution containing hydroxide/water, carbonate, chlorine, bromine, iodine, nitrate, and nitrite ions with added kaolinite. Experiments were conducted with twenty-five different sets of process conditions. Resulting powders were characterized by quantitative X-ray diffraction (XRD) and multi-functional thermal analysis, including gravimetry, calorimetry, and mass spectrometry. Using statistical analysis, process variables were tailored to maximize conversion of kaolinite into cage silicates, immobilize caustic scrubber anions, and minimize amorphous content. Further, chemical analysis showed the incorporation of all the targeted ions into the solids. Detailed investigation of a batch characterized after washing (creating secondary waste) and one without washing but subsequent calcination is given. This work contributes to defining the constraints required for subsequent consolidation process steps of the waste form to avoid volatilization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simultaneous removal of SO{sub 2}, NOx, and Hg from coal flue gas using a NaClO{sub 2}-enhanced wet scrubber

A bench-scale study was conducted on the simultaneous removal Of SO{sub 2}, NOx, and mercury (both Hg{sup 0} and Hg{sup 2+}) from a simulated coal flue gas using a wet calcium carbonate scrubber. The multipollutant capacity of the scrubber was enhanced with the addition of the oxidizing salt, sodium chlorite. The results showed a maximum scrubbing of 100% for SO{sub 2} and Hg species and near complete NO oxidation with about 60% scrubbing of the resulting NOx species. The chlorite additive was less effective as an oxidant in the absence of SO{sub 2} and NO in the flue gas. Oxidation of NO and mercury were only about 50% and 80%, respectively, in the case of no SO{sub 2} in the simulated flue gas. The mercury oxidation was similarly affected by the absence of NO in the flue gas.

01 COAL, LIGNITE, AND PEAT↗

Novel Adsorbent-Reactants for Treatment of Ash and Scrubber Pond Effluents

The overall goal of this project was to evaluate the ability of novel adsorbent/reactants to remove specific toxic target chemicals from ash and scrubber pond effluents while producing stable residuals for ultimate disposal. The target chemicals studied were arsenic (As(III) and As(V)), mercury (Hg(II)) and selenium (Se(IV) and Se(VI)). The adsorbent/reactants that were evaluated are iron sulfide (FeS) and pyrite (FeS{sub 2}). Procedures for measuring concentrations of target compounds and characterizing the surfaces of adsorbent-reactants were developed. Effects of contact time, pH (7, 8, 9, 10) and sulfate concentration (0, 1, 10 mM) on removal of all target compounds on both adsorbent-reactants were determined. Stability tests were conducted to evaluate the extent to which target compounds were released from the adsorbent-reactants when pH changed. Surface characterization was conducted with x-ray photoelectron spectroscopy (XPS) to identify reactions occurring on the surface between the target compounds and surface iron and sulfur. Results indicated that target compounds could be removed by FeS{sub 2} and FeS and that removal was affected by time, pH and surface reactions. Stability of residuals was generally good and appeared to be affected by the extent of surface reactions. Synthesized pyrite and mackinawite appear to have the required characteristics for removing the target compounds from wastewaters from ash ponds and scrubber ponds and producing stable residuals.

54 ENVIRONMENTAL SCIENCES↗

Glass-bonded ceramic waste forms for immobilization of radioiodine from caustic scrubber wastes

Glass-bonded sodalite composite waste forms have been developed for the immobilization of liquid radioactive wastes resulting from off-gas treatment during aqueous reprocessing of used nuclear fuel, with a particular focus on 129I. The proposed composite waste form is comprised of aluminosilicate ceramic phases containing volatile radionuclides bonded with a glassy matrix. In this work, a suite of ten candidate low-temperature glass binders (ZnO-Bi2O3-based glasses and a Na2O-B2O3-SiO2 glass) were examined. Six glasses were mixed with caustic scrubber waste simulant previously converted into a sodalite-rich material (to provide glass fractions of 10 and 20 wt.%), uniaxially pressed into pellets, and sintered at 350 °C or 550 °C for 8 h in air. Iodine retention after heat treatment was assessed by neutron activation analysis, showing retention of 67-100 % of expected iodine. The aqueous durabilities of the resulting materials were then determined, following the ASTM C1308 standard test, showing iodine releases of 1 to 23 g m-2 after 4 d. The cumulative iodine release for the best performing system (a zinc-bismuth-borate glass binder) was <1 g m-2, and its iodine retention from processing was 67 %. The iodine releases compared favorably with other waste forms. In parallel, this best-performing composition was also consolidated via hot isostatic pressing (HIP) in a stainless-steel canister at 550 °C for 2 h under 100 MPa pressure. The HIPed sample was produced at the ~20 g scale and showed improved densification and minimal reaction with the canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Polycyclic aromatic hydrocarbon emission profiles and removal efficiency by electrostatic precipitator and wetfine scrubber in an iron ore sintering plant

A monitoring campaign of polychlorinated dibenzo-p-dioxins and dibenzofurans, polyaromatic hydrocarbons (PAHs), and polychlorinated biphenyl was carried out in an Italian iron ore sintering plant by sampling the combustion gases at the electrostatic precipitator (ESP) outlet, at the Wetfine scrubber (WS) outlet, and by collecting the ESP dust. Few data are available on these micropollutants produced in iron ore sintering plants, particularly from Italian plants. This study investigates the PAH emission profiles and the removal efficiency of ESPs and WS. PAHs were determined at the stack, ESP outlet flue gases, and in ESP dust to characterize the emission profiles and the performance of the ESP and the WS for reducing PAH emission. The 11 PAHs monitored are listed in the Italian legislative decree 152/2006. The mean total PAH sum concentration in the stack flue gases is 3.96 {mu}g/N m{sup 3}, in ESP outlet flue gases is 9.73 {mu}g/N m{sup 3}, and in ESP dust is 0.53 {mu}g/g. Regarding the emission profiles, the most abundant compound is benzo(b)fluoranthene, which has a relative low BaP toxic equivalency factors (TEF) value, followed by dibenzo(a,l)pyrene, which has a very high BaP(TEF) value. The emission profiles in ESP dust and in the flue gases after the ESP show some changes, whereas the fingerprint in ESP and stack flue gases is very similar. The removal efficiency of the ESP and of WS on the total PAH concentration is 5.2 and 59.5%, respectively. 2 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Update: what's that scrubber going to cost?

Power published a summary of the flue gas desulfurization system scrubber cost survey conducted by the EUCG's Fossil Productivity Committee in the July 2007 issue. Although the detailed results of the latest survey are proprietary to EUCG members that participated in it, the paper presents the newest summary data. The bottom line is costs continue to rise but appear to be more predictable. 7 figs.

01 COAL, LIGNITE, AND PEAT↗

Waste Treatment and Immobilization Plant U. S. Department of Energy Office of River Protection Submerged Bed Scrubber Condensate Disposition Project - 13460

The Hanford Waste Treatment and Immobilization Plant (WTP) will generate an off-gas treatment system secondary liquid waste stream [submerged bed scrubber (SBS) condensate], which is currently planned for recycle back to the WTP Low Activity Waste (LAW) melter. This SBS condensate waste stream is high in Tc-99, which is not efficiently captured in the vitrified glass matrix [1]. A pre-conceptual engineering study was prepared in fiscal year 2012 to evaluate alternate flow paths for melter off-gas secondary liquid waste generated by the WTP LAW facility [2]. This study evaluated alternatives for direct off-site disposal of this SBS without pre-treatment, which mitigates potential issues associated with recycling. This study [2] concluded that SBS direct disposal is a viable option to the WTP baseline. The results show: - Off-site transportation and disposal of the SBS condensate is achievable and cost effective. - Reduction of approximately 4,325 vitrified WTP Low Activity Waste canisters could be realized. - Positive WTP operational impacts; minimal WTP construction impacts are realized. - Reduction of mass flow from the LAW Facility to the Pretreatment Facility by 66%. - Improved Double Shell Tank (DST) space management is a benefit. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of Submerged Bed Scrubber Assumptions in the Hanford Waste Treatment and Immobilization Plant Bases and Requirements Document

A review was performed of the assumptions in the Hanford Waste Treatment and Immobilization Plant Bases and Requirements Document (BARD) for the Low Activity Waste (LAW) Submerged Bed Scrubber (SBS). This review was performed to evaluate how the assumptions impact the TOPSim process models that utilize the assumptions for system modeling. The RPP Integrated Flowsheet uses TOPSim to model the entire waste retrieval and treatment process for the Hanford tank waste. This model relies on a number of inputs, including the BARD. The BARD represents the basis for the WTP process models; as such, it contains some assumptions that are valid for the models that will not accurately reflect actual operation. For example, the amount of LAW condensate generated is overstated in the BARD to allow for conservatism in the design of the condensate handling unit operations. The assumptions in the BARD for the LAW SBS were reviewed to evaluate how actual operation could differ from the design basis assumptions. It should be noted that this review did not evaluate nor is it intended to address issues related to design of the WTP facility such that the information in this report is should not be viewed as issues with the design of the WTP facility nor should the information be used without additional evaluation to generate design concerns.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Treatment And Immobilization Plant U. S. Department Of Energy Office Of River Protection Submerged Bed Scrubber Condensate Disposition Project - Abstract # 13460

The Hanford Waste Treatment and Immobilization Plant (WTP) will generate an off-gas treatment system secondary liquid waste stream [submerged bed scrubber (SBS) condensate], which is currently planned for recycle back to the WTP Low Activity Waste (LAW) melter. This SBS condensate waste stream is high in Tc-99, which is not efficiently captured in the vitrified glass matrix. A pre-conceptual engineering study was prepared in fiscal year 2012 to evaluate alternate flow paths for melter off-gas secondary liquid waste generated by the WTP LAW facility. This study evaluated alternatives for direct off-site disposal of this SBS without pre-treatment, which mitigates potential issues associated with recycling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗