Engineering PapersSearch

SEARCH · Engineering Papers

Results for “SBN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Pandora-based muon neutrino disappearance search in the SBN program with 1muonNp quasi-elastic like channel

The Short-Baseline Neutrino (SBN) program at Fermilab aims to perform a definitive search for light sterile neutrinos using multiple liquid argon time projection chamber detectors. We present the status of an analysis of muon neutrino charged-current interactions in two SBN detectors (SBND and ICARUS), selecting fully contained events with one muon and at least one proton in the final state, inspired by the recent ICARUS standalone results. This topology-driven selection reduces dependence on neutrino interaction cross-section modeling while preserving high statistics and good neutrino energy resolution, enabled by robust reconstruction and particle identification. Fully contained events enable precise kinematic reconstruction and support relative measurements between detectors, directly addressing the core goals of the SBN program. A detailed evaluation of systematic uncertainties is currently underway, with the objective of reducing the dominant systematics to the percent level. The current status of this analysis, with a particular focus on the event selection performance, will be presented in this poster.

Artero Pons, Maria [Padua U.; INFN, Padua]

Constraining Systematics at SBND to Reduce Uncertainties in SBN Oscillation Analyses

The Short Baseline Near Detector (SBND) is a crucial component of the Short Baseline Neutrino (SBN) Program, situated 110 meters from the Booster Neutrino Beam (BNB) target. This 112-ton Liquid Argon Time Projection Chamber (LArTPC) Near Detector is optimally positioned to investigate the potential existence of an additional flavor of neutrino through neutrino oscillation. Due to its proximity to the BNB target, SBND is uniquely positioned to receive a high rate of un-oscillated neutrino events. This setup offers a valuable opportunity to examine exclusive channels, thereby enhancing our understanding of various neutrino interaction modes, aiding in the understanding and mitigation of various sources of uncertainties. By fully utilizing the detector's capabilities, we aim to mitigate significant uncertainties in neutrino oscillation studies, primarily those related to neutrino interactions and flux. Achieving a deeper understanding of these uncertainties and controlling them with near detector data is essential. In this poster I will present an SBND event selection to control these uncertainties for the SBN oscillation analyses.

Yadav, Shweta [Texas U., Arlington]

Latest Results from the ICARUS Experiment at the SBN Program

The ICARUS Collaboration is now entering its fifth year of continuing operations of the 760-ton liquid argon T600 detector. The T600 was overhauled at CERN after operations at the LNGS underground laboratory in Italy and moved to its present location at FNAL - as part of the Short-Baseline Neutrino (SBN) program - where it successfully completed its commissioning phase in June 2022. At FNAL ICARUS collects neutrino interactions from both the Booster Neutrino Beam (BNB) and off-axis from the Main Injector Neutrino beam (NuMI). To date, ICARUS has accumulated approximately $7.5\cdot 10^20$ protons on target (POT) with the BNB and about $6.2\cdot 10^20$ POT with NuMI. Within the SBN program ICARUS will search for evidence of short-baseline oscillations, potentially explained by eV-scale sterile neutrinos, jointly with the Short-Baseline Near Detector (SBND). In addition, ICARUS is performing stand-along oscillation searches in disappearance mode and measuring neutrino cross sections on argon with both the BNB and NuMI beams. It is also performing searches for additional Beyond the Standard Model signatures. Preliminary results from the ICARUS experiment, using data from the BNB and NuMI neutrino beams, will be presented.

Ricci, Alessandro Maria [U. Pisa (main); INFN, Pis

Search for muon neutrino disappearance with multi-topologically splitted Inclusive events at SBN

The Short-Baseline Neutrino (SBN) program at Fermilab searches for signatures of sterile neutrinos with mass-squared splittings at the O(1) eV2 scale, motivated by anomalies previously reported by the LSND and MiniBooNE experiments. We present a search for such signatures using the muon neutrino disappearance channel. This analysis exploits the large statistics of fully inclusive charged-current interactions collected by the SBND and ICARUS detectors to maximize sensitivity. The inclusive samples in both detectors are further subdivided into multiple exclusive topological channels, a strategy designed to enhance sensitivity by isolating differences in interaction-mode composition and reconstructed energy response. This multi-topology approach represents a novel analysis technique within SBN, enabling improved constraints on systematic uncertainties arising from neutrino flux, interaction modeling, and detector response. We will present comparisons of data with detailed predictions incorporating a comprehensive treatment of systematic uncertainties and constraints on the systematics obtained by the multi-topology method.

Yadav, Shweta [Texas U., Arlington]

Commissioning of the trigger system for the ICARUS T600 LAr-TPC detector in SBN Program

The ICARUS experiment at Fermilab is the far detector of the Short Baseline Neutrino Program (SBN), aimed at studing the neutrino oscillation to find a fourth type of neutrino, called sterile neutrino. A key component for this detector is the trigger system, which aims to identify and isolate the physical interactions from the background events. In this framework my internship program was dedicated to the development of trigger logic and trigger inhibit mechanism in order to select the genuine neutrino interaction and to guarantee a correct functioning of the readout system. These two steps, that represent a part of the commissioning of the trigger system, were implemented with LabVIEW Software. The obtained results are a fundamental step towards a succesful activation of the detector in the next few months.

43 PARTICLE ACCELERATORS

Search for Neutral Current Disappearance at the SBN Program

● The Short Baseline Neutrino (SBN) Program is a multi-detector oscillation program located at Fermilab. ● The program has world-leading sensitivity to neutrino oscillations and will be able to make a definitive rejection or acceptance of the sterile neutrino hypothesis.

Pallat, Nicole [Minnesota U.]

Electron Neutrino Selection for Neutrino Oscillation Searches in the SBN Program

The Short- Baseline Neutrino (SBN) Pprogram at Fermilab employs a near detector, SBND, and a far detector, ICARUS, to search for baseline-dependent changes to the measure muon neutrino disappearance and electron neutrino appearance and disappearance from the muon neutrino-dominated Booster Neutrino Beam flux. The use of the same liquid argon time projection chamber (LArTPC) technology in both detectors and the same neutrino beam enables a systematically well-constrained oscillation measurement, by leveraging the high statistics of O(10 million) neutrino interactions expected at SBND through 2027 to constrain flux and cross-section systematics. In this poster, we present high-statistics, high-purity electron neutrino selections in SBND and ICARUS and related electron shower energy calibration measurements in SBND enabled by the SPINE deep learning-based particle reconstruction framework. Furthermore, we discuss how these samples can enable high sensitivity to '3+1' sterile neutrino oscillations in a combined fit accounting for systematic uncertainties and correlations.

Oza, Nupur [Nevis Labs, Columbia U.; Columbia U.]

Machine Learning-Based Anomaly Detection for PMT Data Quality Monitoring in the SBN and DUNE

Maintaining high-quality detector data is essential for achieving the scientific objectives of the Short-Baseline Neutrino (SBN) Program at Fermilab. Current data quality monitoring (DQM) procedures rely primarily on threshold-based metrics and manual inspection of detector monitoring plots, making the detection of subtle or gradually developing anomalies both time-consuming and dependent on expert interpretation. This project developed and evaluated a machine-learning workflow for automatically identifying anomalous photomultiplier tube (PMT) channels in the Short-Baseline Near Detector (SBND) using optical-hit amplitude data. A Python-based analysis program was developed to process ROOT files, extract statistical features describing individual PMT amplitude distributions, and generate feature vectors for anomaly detection. These features were used to train an Isolation Forest model using data representing normal detector operation. The trained model was subsequently applied to independent detector runs to identify channels exhibiting statistically unusual behavior relative to the learned reference response. To support expert interpretation, the workflow generated complementary diagnostic products, including anomaly score distributions, normalized amplitude comparisons, decision-tree visualizations, and principal component analysis (PCA) projections. This project demonstrated the feasibility of integrating unsupervised machine learning into detector data-quality monitoring and developed a complete workflow for automated PMT performance assessment to aid expert-driven review. Beyond its technical contributions, the VFP appointment fostered a research collaboration between Aurora University and Fermilab and provided direct workforce development benefits by training the visiting faculty member in detector-scale machine-learning methods that are now being incorporated into undergraduate coursework and research. The methodology developed here provides a foundation for future applications to ProtoDUNE and other liquid argon time projection chamber (LArTPC) detectors, contributing to ongoing efforts to improve detector reliability, reduce manual monitoring requirements, and enable scalable data quality monitoring for future large-scale neutrino experiments, including the Deep Underground Neutrino Experiment (DUNE).

Colón Santana, Juan A. [Unlisted, US, IL]

Comparison of ACHILLES and GENIE observables for DUNE-PRISM and the SBN program, with new 2p2h predictions

Several DUNE ND off axis locations were simulated using GENIE and ACHILLES, and generator differences and FSI contributions were examined for various observables. Predictions were compared with those of existing experiments, and it is shown that the DUNE ND 20m off axis predictions are similar to that of MicroBooNE for various observables. Finally, the 2p2h interaction mode was simulated for ACHILLES for the first time for ICARUS, and a preliminary comparison is made to MicroBooNE data and simulations from different event generators.

Dumont, Daniel [Fermilab]

Comparison of ACHILLES and GENIE Observables for DUNE-PRISM and the SBN Program, with New 2p2h Predictions

The DUNE near detector LAr-TPC can be moved to different off-axis positions to sample different neutrino fluxes, which in turn will yield different cross section distributions for observables. Several DUNE ND off axis locations were simulated using GENIE and ACHILLES, and generator differences and FSI contributions were examined for various observables. Additionally, the predictions were compared with those of existing experiments, and it is shown that the DUNE ND 20m off axis predictions are similar to that of MicroBooNE for various observables. Finally, the 2p2h interaction mode was simulated for ACHILLES for the first time for ICARUS, and a preliminary comparison is made to MicroBooNE data and simulations from different event generators.

Dumont, Daniel [Fermilab]

Search for numu Disappearance in the Short-Baseline Neutrino Program Utilizing an Exclusive 1mu1p QE-Like Final State

The Short-Baseline Neutrino (SBN) program at Fermilab is searching for neutrino oscillations over a short baseline as a signature of a sterile neutrino with a mass splitting of about 1eV2. Such oscillations would drive the disappearance of muon neutrinos in the Booster Neutrino Beam between the detectors of the SBN Program. We present progress on an analysis to search for muon neutrino disappearance between the SBND and ICARUS detectors (the SBN Program's near and far detectors, respectively). This analysis leverages the one muon, one proton, quasi-elastic-like final state, which provides the best resolution for reconstructing the neutrino energy. The analysis incorporates a comprehensive set of systematic uncertainties in the neutrino flux, interaction, and detector model. This analysis will soon be completed as part of the first oscillation results at SBN.

Rowe, Nathaniel [U. Chicago (main)]

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]

Status and Prospects of SBND

The Short-Baseline Near Detector (SBND) is one of the neutrino detectors positioned along the the Booster Neutrino Beam (BNB) at Fermilab. It is the near detector in the Short-Baseline Neutrino (SBN) Program, as well as having a wide-ranging independent physics program. The detector began taking neutrino data in the summer of 2024 and has already collected over 1 million neutrino events. Thanks to its unique combination of measurement resolution and statistics, SBND will soon carry out a rich program of neutrino interaction measurements and novel searches for physics beyond the Standard Model (BSM). As the SBN near detector, it will enable the full potential of the SBN sterile neutrino program by performing a precise characterisation of the unoscillated event rate and constraining BNB flux and neutrino-argon cross-section systematic uncertainties. In this talk, the physics reach, current status, and future prospects of SBND are discussed.

Paton, Josephine [Fermilab]

Analysis of the automatic reconstruction of protons from simulated neutrino interactions in the ICARUS detector: study of the performance of track vs shower discrimination algorithms

ICARUS, Imaging Cosmic and Rare Underground Signals, is the far detector of the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). This program was born with the purpose of definitely explaining some anomalies in the field of neutrino oscillation physics, that can suggest the existence of a 4-type of neutrino: the sterile neutrino. It doesn’t interact directly with ordinary matter through the weak interaction, but we can observed the effect of its oscillation. In this chapter I will briefly observe: • the physics goals of the SBN Program; • the role of ICARUS as SBN far detector; • the detection technology.

43 PARTICLE ACCELERATORS

Performance of Muon Neutrino Reconstruction at ICARUS using SPINE Machine Learning.

ICARUS is a liquid argon time projection chamber (LArTPC) neutrino experiment at Fermilab. Located ~600 m from the Booster Neutrino Beam (BNB) target, it serves as the far detector in the Short-Baseline Neutrino (SBN) Program. The primary objective of the SBN Program is to probe neutrino oscillation physics at short baselines using multiple detectors, including measurements of both muon neutrino disappearance and electron neutrino appearance. A key requirement for the neutrino oscillation measurements is robust event reconstruction, including accurate and precise particle identification (PID) and kinematic reconstruction across a wide range of topologies. To achieve the required performance, we employ the SPINE (“Scalable Particle Imaging with Neural Embeddings”) package, a state-of-the-art machine learning reconstruction framework. This talk presents the status of muon neutrino reconstruction using SPINE at ICARUS, including the evaluation of reconstruction performance that will enable the full physics program at ICARUS and at the SBN Program.

Totani, Dante [Colorado State U.] (ORCID:000000019