Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAVANNAH RIVER PLANT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Airborne lidar experiments at the Savannah River Plant

The results of remote sensing experiments at the Department of Energy (DOE) Savannah River Nuclear Facility utilizing the NASA Airborne Oceanographic Lidar (AOL) are presented. The flights were conducted in support of the numerous environmental monitoring requirements associated with the operation of the facility and for the purpose of furthering research and development of airborne lidar technology. Areas of application include airborne laser topographic mapping, hydrologic studies using fluorescent tracer dye, timber volume estimation, baseline characterization of wetlands, and aquatic chlorophyll and photopigment measurements. Conclusions relative to the usability of airborne lidar technology for the DOE for each of these remote sensing applications are discussed.

Krabill, William B.↗

Utilization of Unmanned Aircraft Systems for Environmental Purposes at the Savannah River Site – 26578

Born in the 1950s, the Savannah River Plant was constructed as a plutonium and tritium production plant. As the Cold War era came and went, a change of direction was signaled when the name of the facility changed from Savannah River Plant to Savannah River Site (1989) – the main mission at Savannah River shifted from “production” to “cleanup.” The Department of Energy is responsible for managing the 310 square miles of land that is the Savannah River Site and the cleanup/remediation activities that occur. The Savannah River National Laboratory utilizes unmanned aircraft systems to assist with some of those environmental monitoring and remediation activities. One function of unmanned aircraft systems at the Savannah River National Laboratory is conducting aerial photography and videography. Various infrastructure evaluations have been performed with unmanned aircraft – facility rooftop inspections, water tower lock verifications, earthen dam surveys, etc. An unmanned aircraft system has been used for progress footage of remediation projects – Dunbarton Bay remediation, Saltstone Disposal Unit construction, etc. Thermal cameras on an unmanned aircraft system are used to help identify cracks/leaks in structures from vantage points not readily accessible by personnel. Virtual tours of different waste units are conducted with unmanned aircraft systems for Site groups and federal/state regulators to save costs and travel time. Additionally, advanced remote sensing technologies are used on unmanned aircraft systems at the Savannah River Site. Light Detection and Ranging uses laser pulses to measure distances to the Earth's surface or other targets to create highly detailed topographic maps that accurately portray terrain (e.g., elevation changes, slopes, and contours). Data collection with a Light Detection and Ranging unit mounted on an unmanned aircraft system is quick and efficient – large-area surveys are conducted in shorter time frames. Because Light Detection and Ranging can penetrate through foliage and vegetation to ground level, it is being used in conjunction with a watershed model to study the General Separations Area of the Site to determine stormwater flow volume and direction, monitor stream stability, and forecast river flow behavior. A hyperspectral camera captures a wide spectrum of electromagnetic wavelengths across numerous narrow bands, beyond what the human eye can see. It provides detailed spectral information about the objects or surfaces in an image, which can be used to identify and analyze materials based on their spectral signatures. A hyperspectral camera mounted on an unmanned aircraft system has been used at the Savannah River Site for non-destructive evaluation of concrete and concrete structures. Unmanned aircraft systems at the Savannah River Site are also used for the application of herbicide on identified rooftops. P-Reactor and R-Reactor are entombed nuclear reactors at the Savannah River Site. Unwanted vegetation is often present on these rooftops – over time roots can penetrate seams, cracks, and joints of the general roof and concrete caps, leading to water ingress and deterioration of the structural components. For time and cost efficiencies as well as in the interest of personnel safety, an unmanned aircraft is used to dispense herbicide on rooftop areas where vegetation is noticed to help alleviate the issues/hazards.

Lorier, Troy [Savannah River National Laboratory (↗

Panel Session 34: US DOE Featured Site: Savannah River Operations Office: 70 Years of Service

The Savannah River Site celebrates its 70. anniversary on November 28, 2020. On this date in 1950, President Harry S. Truman requested the Dupont Company to design, build and operate what was then known as the Savannah River Plant in response to the Soviet Union's detonation of its first atomic weapon, which set the Cold War into motion. During the 1950's, six South Carolina towns were relocated for the construction of SRS and by 1953, the 310 square mile site was complete. Nearly 40,000 workers were employed t build five nuclear reactors and support facilities, two chemical separations plants, heavy water extraction plant, nuclear fuel and target fabrication facility tritium extraction facility and waste management facilities. SRS played a key role in winning the Cold War and for seven decades, SRS has been a leader within the DOE complex. Today, the site supports environmental stewardship and maintains the nation's nuclear deterrent while ensuring the safekeeping and disposal of domestic and international nuclear materials. The site continues to support the nation's nuclear defense as it explores new potential NNSA missions. SRS has a proud 70- year history and looks forward to a future of service as a national asset and strong community partner. The session was kicked off with a video message from Secretary of Energy, Dan Brouillette, who thanked employees past and current for their efforts. The video also provided an overview of the history and future of the Site. This panel provided an overview of the Savannah River Site's 70 years of service (history, challenges, opportunities, and future) presented by the SRS's Senior leadership and the local Aiken, South Carolina Mayor. Panelists with presentations: US DOE Secretary Dan Brouillette's Overview of DOE and SRS - A Legacy of 70 Years of Service (Amy Boyette); 70 Years of Service (Michael Budney); 70 Years of Service (Stuart MacVean); SRS Liquid Waste (Thomas Foster); National Nuclear Security Administration (Nicole Nelson-Jean)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CMP Pits and D-Area Watershed Infiltrometer Testing

Savannah River National Laboratory (SRNL) conducted saturated hydraulic conductivity field testing at the Chemical, Metals, and Pesticide Pits (CMP Pits) and the D-Area watershed to develop infiltration rates for use in future updates to the CMP Pits groundwater flow model. Approximately 18 testing locations were selected at each site based on the soil series that were identified in the Soil Survey of Savannah River Plant Area, Parts of Aiken, Barnwell, and Allendale Counties, South Carolina.

54 ENVIRONMENTAL SCIENCES↗

CMP Pits and D-Area Watershed Infiltrometer Testing

Savannah River National Laboratory (SRNL) conducted saturated hydraulic conductivity field testing at the Chemical, Metals, and Pesticide Pits (CMP Pits) and the D-Area watershed to develop infiltration rates for use in future updates to the CMP Pits groundwater flow model. Approximately 18 testing locations were selected at each site based on the soil series that were identified in the Soil Survey of Savannah River Plant Area, Parts of Aiken, Barnwell, and Allendale Counties, South Carolina.

54 ENVIRONMENTAL SCIENCES↗

Influence of tritium exposure route on vegetation types at the Savannah River Site

Plant, soil, water, and other media from various locations at the Savannah River Site were measured for total tritium (T) content and T speciation to characterize T in these areas, as well as investigate its uptake behavior and the transport of T species in these media. This characterization included the isolation and measurement of T in tritiated water (HTO), and (when possible) exchangeable organic bound T (E-OBT) and non-exchangeable organic bound T (NE-OBT). Two areas of interest were investigated: (1) a holding pond with T-contaminated water and (2) open basins or streams with low to background levels of T. Water in the holding pond is used to irrigate forest plots in the local area as a T remediation approach. This study compares the analytical data for water, soil/sediment, plants, and lichens from these locations. Here, the results indicate that the behavior of T in plants from these areas can be a function of one or more of the following: seasonal precipitation, the plant's primary route of access to the T-contamination (such as water uptake through the root vs. shoot), plant physical location (relative to T-contaminated water sources), plant rooting depth, pond water level, and plant height above the ground. Total T concentrations were lowest in the un-irrigated forest plants, followed by irrigated forest plants, shallow rooting plants near the pond, deep rooting plants further from the pond, and then water-saturated plants. The OBT:HTO and NE-OBT:E-OBT ratios were always greater for plants from irrigated forest plots compared to those from the holding pond.

36 MATERIALS SCIENCE↗

Mapping diverse vegetation with multichannel radar images

Airborne-SAR, SIR-A, Seasat SAR, and Landsat TM images of the Savannah River Plant, a gently sloping area of South Carolina covered with diverse vegetation, are presented and briefly characterized. Preliminary results indicate that multiple-polarization images constructed from the airborne-SAR data give some indication of forest density and understory growth but do not permit discrimination between evergreen and deciduous forests. Heat-tolerant vegetation growing on sand bars in streams bearing thermal effluents from nuclear reactors on the site is found to have a distinguishing polarization signature.

Ford, J. P.↗

Zero-Valent Iron Permeable Reactive Barrier to Remediate Volatile Organic Compounds in Groundwater - 20209

The US DOE-SRS, the US EPA, and the South Carolina Department of Health and Environmental Control determined it was appropriate to perform a non-time critical removal action at the P-Area Groundwater Operable Unit at the SRS to reduce the mass and downgradient transport of trichloroethylene in the P-Area groundwater plume. Contaminated groundwater discharges to a nearby stream, Steel Creek, within the SRS boundaries, resulting in trichloroethylene concentrations above the maximum contaminant level. Impact to surface water is limited in areal extent and supported by recently collected characterization data. The P-Area Groundwater Operable Unit encompasses the groundwater beneath an industrial area within SRS, P Area, where the P-Reactor once operated. The boundaries of the P-Area Groundwater Operable Unit extend northwest to Steel Creek, northeast toward PAR Pond, and southeast to Meyers Branch. Groundwater in the Upper Three Runs Aquifer of the P-Area Groundwater Operable Unit has been impacted by reactor and facility operations between 1954 and 1991, including tritium and volatile organic compounds. The P-Area surface units contributing to groundwater contamination were remediated as part of the P-Area Operable Unit in 2011. The P-Reactor closure is one of the first of its kind in the DOE Complex and is one of only a few full-sized production reactors in the US to undergo completion of final closure activities. The nature and extent of groundwater contamination was determined using a variety of investigative approaches such as groundwater monitoring wells, direct-push technology, and surface water samples. Groundwater contamination associated with trichloroethylene is primarily exhibited in a narrow plume that extends from the source area at P-Reactor and west to Steel Creek. Maximum contaminant level exceedances in groundwater occur over an area of ∼6.9 hectares for trichloroethylene with concentrations as high as 7.7 milligrams per liter. To the west of the P-Area facility area, the trichloroethylene groundwater plume is controlled by a buried geologic feature, assumed to be an old stream bed, that further narrows the groundwater plume in what has been designated as the 'neck area.' This narrowing of the groundwater plume provides an ideal location for a treatment barrier. The non-time critical removal action alternative chosen is to install a zero-valent iron permeable reactive barrier within the neck area of the trichloroethylene groundwater plume, perpendicular to groundwater flow direction. This technology will provide a treatment barrier that will reduce trichloroethylene groundwater concentrations by 90% and has an anticipated useful life of at least 25 years. A pre-design investigation was performed in the neck area to confirm site lithology, hydrogeology, geochemistry, and extent of trichloroethylene contamination prior to a final design. A treatability study, conducted as part of the pre-design investigation, indicated that the subsurface and groundwater in the PArea Groundwater Operable Unit is compatible with the zero-valent iron and will not lead to excessive buildup from mineralization/precipitation or biofouling. Probabilistic modeling was conducted using field and laboratory data to determine the expected performance of the zero-valent iron permeable reactive barrier. The model simulations indicated that a 3.81-centimeter thick barrier would provide greater than 90% reduction of trichloroethylene groundwater concentration. The final design of the zero-valent iron permeable reactive barrier is a barrier that will extend 80.5 linear meters in a 'zigzag' orientation to best transect the trichloroethylene plume and account for varying groundwater flow. The barrier will be installed from 13.7 meters below ground surface to 41.1 meters below ground surface for 65.8 linear meters and from 13.7 meters below ground surface to 36.6 meters below ground surface for 14.6 linear meters, the base of which is 'keyed' into a low permeability zone. The barrier is designed to a thickness of 10.2 centimeters, which was determined to reduce the trichloroethylene groundwater concentrations by greater than 90% with a safety factor of 2.67. A total of approximately 689 metric tons of zero-valent iron will be injected through 22 injection wells spaced 3.66 meters apart, using guar to suspend the zero-valent iron. Zero-valent iron permeable reactive barrier construction will be monitored through 23 installed resistivity receivers offset 7.32 meters from the zerovalent iron permeable reactive barrier. The zero-valent iron will be energized with a low-voltage 100 Hertz signal during injection and will be monitored using the resistivity receivers to ensure complete coalescence of the zero-valent iron permeable reactive barrier. The zero-valent iron was sized to have a hydraulic conductivity greater than the natural subsurface, thus promoting groundwater flow through the barrier. As contaminated groundwater contacts the zero-valent iron, volatile organic compounds, including trichloroethylene, are immediately degraded to harmless compounds such as ethylene. The performance of the zero-valent iron permeable reactive barrier will be monitored using three upgradient monitoring well clusters, six downgradient monitoring well clusters, and four in-wall monitoring wells. The in-wall monitoring wells will indicate immediate reduction of trichloroethylene mass in the groundwater and allow analyses of the zero-valent iron permeable reactive barrier health. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testing of Crystalline Silicotitanate to Support Tank-Side Cesium Removal System Operations - 20458

The direct feed of waste from the Hanford tank farms to the Low-Activity Waste Facility at the Hanford Waste Treatment and Immobilization Plant requires an intermediate treatment step that prepares the waste for vitrification. Washington River Protection Solutions (WRPS) selected a near-tank treatment system known as the Tank-Side Cesium Removal (TSCR) system to perform the required intermediate treatment functions. The approach in the TSCR system is to filter waste supernatant with a sintered metal dead-end filter and then use a series of ion exchange columns to remove cesium; this system has several similarities to the Tank Closure Cesium Removal system that has been deployed on the Savannah River Site. The ion exchange media proposed for use is crystalline silicotitanate (CST), which is a non-elutable media with a high affinity for cesium. Because the media is non-elutable, loaded columns will be blown down with compressed air, moved into interim storage, and replaced with new columns when cesium capacity is reached. The assumed extent and rate of drying that could be achieved in the TSCR column geometry lacked confirmation by experimental data. In addition, once the columns are loaded with cesium, they generate flammable gases (primarily hydrogen) via radiolysis acting on any resident liquids, i.e., moisture, remaining in the media bed. An assessment of available information on CST concluded that gas generation data that bounds expected operational conditions were needed to support the TSCR system safety basis and planned operations. Working with WRPS, Pacific Northwest National Laboratory (PNNL) designed and conducted testing with CST media to address the need for (a) representative in-column drying data, and (b) bounding flammable gas generation data. Drying testing was performed using a full-height column with a diameter of approximately 2 inches with injected air at temperatures of 18 deg. C and 30 deg. C. Gas generation testing was conducted in an engineered bunker that allowed simultaneous irradiation of up to eight samples at a time. These two experimental approaches used at PNNL for the CST testing are summarized and the major outcomes are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of DWPF Sludge Batch 6 (Macrobatch 7): Pour Stream Glass Samples

The Defense Waste Processing Facility (DWPF) began processing Sludge Batch 6 (SB6), also referred to as Macrobatch 7 (MB7), in June 2010. SB6 is a blend of the heel of Tank 40 from Sludge Batch 5 (SB5), H-Canyon Np transfers and SB6 that was transferred to Tank 40 from Tank 51.1 SB6 was processed using Frit 418. Sludge is received into the DWPF Chemical Processing Cell (CPC) and is processed through the Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator Tank (SME). The treated sludge slurry is then transferred to the Melter Feed Tank (MFT) and fed to the melter. During processing of each sludge batch, the DWPF is required to take at least one glass sample to meet the objectives of the Glass Product Control Program (GPCP) and to complete the necessary Production Records so that the final glass product may be disposed of at a Federal Repository. The DWPF requested various analyses of radioactive glass samples obtained from the melter pour stream during processing of SB6 as well as reduction/oxidation (REDOX) analysis of MFT samples to determine the impact of Argon bubbling. Sample analysis followed the Task Technical and Quality Assurance Plan (TTQAP) and an Analytical Study Plan (ASP). Four Pour Stream (PS) glass samples and two MFT slurry samples were delivered to the Savannah River National Laboratory (SRNL) from the DWPF. Table 1-1 lists the sample information for each pour stream glass sample. SB6 PS3 (S03472) was selected as the official pour stream sample for SB6 and full analysis was requested. This report details the visual observations of the as-received SB6 PS No.3 glass sample as well as results for the chemical composition, Product Consistency Test (PCT), radionuclide content, noble metals, and glass density. REDOX results will be provided for all four pour stream samples and vitrified samples of MFT-558 and MFT-568A. Where appropriate, data from other pour stream samples will be provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Amplicon Sequencing Assessment to Measure Microbial Community Response from Heavy Metal Contaminated Soils in Savannah River site, Tims Branch watershed

Long-term presence of heavy metal contamination in soils is correlated with changes in microbial community structures and can lead to the reduction of indigenous species. Tolerance to soil heavy metal toxicity varies among different microbial communities. It remains unclear whether long term effects caused by metal perturbations are associated with soil microbial community dysregulation in Tims Branch watershed. Research Questions: Does heavy metal contamination in Tims Branch soils decrease microbial species diversity significantly compared to non-contaminated soils? Does the species richness decrease in contaminated samples? between samples? Is diversity in low, mid and high contamination soils significantly different compared to control samples? Hypothesis: The relative abundance and diversity of species are significantly altered in soils which are contaminated with heavy metals in the Tims Branch watershed. Objectives: Use amplicon sequencing technology along with bioinformatics to compare bacterial communities between four sites in Tims Branch watershed. Evaluate the percent relative abundance and diversity across the site. Conclusions: All bacterial communities exposed to different heavy metal concentrations were dominated by four major groups (Proteobacteria, Acidobacteria, Chloroflexi and Verrucomicrobia). The dominant phyla Proteobacteria, Acidobacteria and Chloroflexi accounted for 61 % of the relative abundance. Soil bacterial α-diversity, expressed as observed species richness metric and Shannon's diversity index, was the highest in sample location four (high contamination). The lowest observed was at the control location. Species richness increased when concentrations of heavy metals were localized, inferring that the metals can alter microbial community structure. PERMANOVA analysis between contaminated groups tested significant using the Adonis (F (4,29) =1.9712; p < 0.001). There is a 20 percent variation explained between groups (R2 = 0.214). This analysis proves to be beneficial in detecting microbial communities altered by contaminated soils. Moreover, certain concentrations of heavy metals can alter microbial community structures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 120: Roundtable: Waste Management - Energy Facilities Contractor Operating Group (EFCOG WM)

This Roundtable focused on the WM EFCOG working group as they met to discuss a variety of issues of importance to US DOE waste management operations. The purpose of the WM EFCOG is to seek out and promote the best management and operating practices, cost effective technologies and disposal options for all waste streams generated at US DOE facilities whether destined for US DOE or commercial facilities. Each site representative provided a radioactive waste management lessons learned briefing. Panelists with presentations: Savannah River Site (SRS) Solid Waste Program Update (Kerri Crawford); Idaho Clean-up Project Status (Frederick Hughes); West Valley Demonstration Project Update - EFCOG Waste Management Working Group (John Rendall); Key Project Challenges and Successes (Kalli Shupe); EFCOG WMWG Challenging Waste Subgroup Update (Tammy Monday); CH TRU Difficult Waste Stream Processing Challenges (Daniel Pancake); Argonne Building 350 Clean-up Success Using Effective Work Control (Daniel Dilday); Problematic Waste Streams on the Oak Ridge Reservation (John Wrapp)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 45: Savannah River National Laboratory Advancing the EM Mission Through Technology

This panel focused on Savannah River National Laboratory (SRNL) activities and addressed: 1) Initial development work that SRNL performed to develop the technologies and processes, as well as design the equipment for the DOE EM HLW tank waste treatment and soil and groundwater mission, 2) Implemented technology and process improvements to the EM systems, and 3) Current technologies being evaluated for future implementation to improve throughput and reduce cost/schedule. Panelists with presentations: Advancing the EM Mission: SRNL Technology Approach (Connie Herman); Nuclear Materials Management (William Bates); Adjust, Adapt, Attest, and Adjudicate (Bruce Wiersma); SRNL Research and Development for Technological Advancements in the Liquid Waste Mission at SRS (Frank Pennebaker); EM TD Applies Solutions at SRS (Andrew Fellinger); Remediation of Complex Groundwater Plumes: Three Decades of Cleanup Success (Carol Eddy-Dilek)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Savannah River Site H-Canyon Process Exhaust Tunnel Inspection Crawler Development - 20036

This paper covers development of a remote crawler used to inspect a subterranean radiochemical process ventilation tunnel located at the Savannah River Site near Aiken, SC. The purpose of the inspection was to ascertain the apparent structural condition of the tunnel with video footage. Manned entry is prohibited due to the hazardous environment requiring a fully-remote approach. The inspection system used high-definition cameras to archive over 1000 linear feet in the tunnel. While previous inspections had been undertaken, this crawler was developed to overcome obstacles that had put tunnel regions out of reach of prior inspection platforms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternative Treatment of Defense Waste Processing Facility Recycle via Reuse of Existing Liquid Waste Facilities - 20097

The Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) has been immobilizing high level waste since 1996. The chemical process within DWPF generates a large volume of condensate, which is recycled to the SRS H-Area Tank Farm. The recycle stream includes a small quantity of sludge solids, as well as soluble cesium that is volatilized during melter operation. The recycle waste is currently received into a large, underground waste tank that separates insoluble solids via decanting. The supernate is treated by an evaporator with a concentrate stream that is stored for future processing. The evaporator overheads are collected and sent to the Effluent Treatment Project (ETP) for final polishing and testing prior to discharge to local surface water. Recycle storage and treatment as described above complicates the overall mission within the tank farms, which are primarily engaged in waste retrieval and preparation activities that support sludge and salt disposition, as well as tank characterization and closure. The need to devote a portion of available storage space to recycle treatment limits operational flexibility, and ultimately the DWPF recycle stream must be diverted to fully close all the SRS waste tanks. An alternative treatment process is being explored to decouple the recycle stream from the tank farm. The proposed treatment process will accomplish solids separation via crossflow filtration and will utilize a wiped film evaporator to volume-reduce the filtrate stream. Evaporator overheads will continue to be further processed in ETP while the solids stream and evaporator concentrate stream will be returned for reprocessing with the DWPF and Salt Waste Processing Facility (SWPF). This process will utilize existing facilities within DWPF and the tank farm that were previously dedicated to Interim Salt Disposition (ISD), but no longer have an identified mission with the startup of SWPF. The reuse of these facilities will remove several constraints from the current Liquid Waste (LW) System Plan without expanding the current footprint of Department of Energy Environmental Management (EM) infrastructure within LW. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Emulsified Oil Bio-Barrier to Remediate CEE in the Distal Portion of a Groundwater Plume - 20210

A non-time critical (NTC) removal action (RA) was designed at the Savannah River Site (SRS) to inject an emulsified oil mixture with a bioaugmentation culture to prevent trichloroethylene (TCE) discharging to surface water above maximum contaminant levels (MCLs). The emulsified oil mixture is expected to sequester the TCE and then be broken down into harmless compounds through microbial biodegradation. At 15 locations 8,290 L (2,190 gal) of oil mixture, buffer and chase water were injected into the subsurface creating two bio-barriers. At each location half of the oil mixture was injected, then 2 L (0.528 gal) of an enriched bioaugmentation culture was injected, and then the second half of the oil mixture was injected into the subsurface. Finally, at each location 151 L (40 gal) of buffer mixed with 575 L (200 gal) of dilution water was then injected followed by 1,135 L (300 gal) of chase water. SRS estimates this created two emulsified oil barriers totaling 73 m (240 ft) long, approximately 3 m (10 ft) high and 4.9 m (16 ft) wide in the subsurface. Similar emulsified oil barriers have been effective for 3 to 5 years, and SRS anticipates a similar longevity for these barriers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Acquisition and Implementation of a Comprehensive Environmental Permits Linking Tool at Savannah River Site - 20234

Historically, Savannah River Nuclear Solutions LLC (SRNS) tracked environmental regulatory commitments and the requirements from hundreds of permits at the Savannah River Site (SRS) using several separate methods, making integrated compliance assurance cumbersome and labor-intensive. When SRNS experienced an increase in environmental issues in 2017, SRNS management and U.S. Department of Energy - Savannah River (DOE-SR) management decided a single, proactive approach was needed to capture environmental permit information (including regulations, Consent Orders, DOE Orders, and any other state or federally issued statement of requirements), track the tasks necessary to ensure compliance with these requirements, and thereby mitigate the risk of noncompliance. SRNS developed a list of mandatory objectives that the tool must meet to function as a Comprehensive Environmental Permits Linking Tool (CEPLT). A key requirement was the ability to map Site permits to their governed locations and display the associated requirements at the compliance point (e.g., outfall, stack, waste unit, etc.). Several options included modifying existing onsite resources, building a custom onsite solution, purchasing an off-the-shelf solution, and contracting an offsite developer to build a custom solution. SRNS concluded an off-the-shelf solution with configuration and customization options would provide the flexibility to fit the unique needs of Savannah River Site (SRS) while taking advantage of industry-tested software and providing a reduced deployment timeline. SRNS chose Gensuite{sup R} a, a cloud-based solution that offers numerous a la carte applications in the environmental, health, and safety arenas, as the best candidate. SRNS selected three (3) integrated applications (Compliance Calendar, Permit Manager, and Mapper) to function as the CEPLT. The Compliance Calendar module allows for creation and tracking of regulatory commitment tasks assigned to responsible environmental professionals. Permit Manager organizes permits and other requirement documents, linking the commitments in each to Compliance Calendar tasks and/or implementing procedures. Mapper provides GIS capability for mapping the data from the other two modules to their physical onsite locations. The CEPLT was configured to allow for other SRS Site Tenants to eventually utilize the applications. Additionally, DOE-SR uses the CEPLT to provide an overview of contractor environmental compliance activities and to organize DOE-specific documents and tasks. The CEPLT fulfilled the requirement of meeting current compliance needs as well as providing the ability to grow as new organizations are incorporated and functionality is expanded. SRNS now uses the CEPLT to more effectively manage permit requirements, improve knowledge transfer, and increase the Site's overall protection of the environment, the Site worker, and the public. Possible future uses of the system include integration of mobile applications for timely communication of potential non-compliant conditions and DOE complex-wide deployment allowing for enhanced DOE site and Head Quarters oversight. Implementation of CEPLT will result in cost savings, both in terms of dollars and man-hours. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling Interfaces to Support Low-Level Waste Disposal System Performance Assessments - 20366

In low-level waste (LLW) disposal sites, interfaces between cementitious materials, used as waste forms and/or engineered barriers, and the surrounding soil or backfill material are often encountered. Reactions across these interfaces may lead to chemical and structural alteration of the cementitious and backfill materials that may ultimately affect long-term performance. For example, the ingress of carbon dioxide from soil gas into a waste tank concrete shell at the Hanford Site or Savannah River Site (SRS) or a low-level waste disposal vault at SRS leads to carbonation of cement hydration products (e.g. portlandite, calcium-silicate hydrate or C-S-H, and ettringite). The result of carbonation is a decrease in pH in the cement paste portion of the tank wall or vault concrete structure that could ultimately lead to de-passivation of the embedded structural steel and, eventually, to cracking. Cracking can lead to increased ingress of water into the structure, corresponding increased release of constituents of concern, and to subsequent increased transport of these constituents to the surrounding environment. The mobility of trace constituents (e.g., radionuclides of concern) in waste forms may increase in response to changes in pH, pore structure, and mineralogical gradients. Depletion of portlandite results in subsequent decalcification of C-S-H that leads to changes in the cement strength and may lead to structural failure. At the boundary between waste forms and concrete vaults, the migration of sulfate ions from the salt waste form (e.g., the saltstone waste form used for LLW disposal at the Savannah River Site in Saltstone Disposal Units, or SDUs) into the barrier or vault concrete has been predicted to result in expansive mineral phase formation (or 'sulfate attack'). Expansive mineral formation could result in cracking and potential loss of structural integrity in the vault concrete. In the performance assessment (PA) for the SRS SDUs, prediction of both the carbonation and sulfate attack fronts are critical to assessing the long-term performance of these LLW disposal vaults. A general purpose geochemical reactive transport model has been developed in LeachXS/ORCHESTRA to evaluate typical interfaces for LLW disposal environments, including SDUs at SRS. The model may be used to predict the long-term performance of interfaces between cementitious materials and saltstone or backfill materials with respect to primary phases by considering mass transport, cement chemistry, geochemical speciation, and multi-ionic diffusion over interfaces between different materials. The present study compares the performance and interactions between vault concrete and saltstone waste form for a representative SDU scenario. The materials were characterized using pH-dependence leaching test (EPA 1313) and semi-dynamic transport tests (EPA 1315) with test results used to parameterize the interface model. The development of a credible inter model provides an important basis for supporting future PAs where carbonation and sulfate attack are important aging and degradation mechanisms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗