Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SACLA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental and Computational Insights into the Structural Dynamics of the Fc Fragment of IgG1 Subtype from Biosimilar VEGF‐Trap

The constant fragment (Fc) of the immunoglobulin G1 (IgG1) subtype is increasingly recognized as a crucial scaffold in the development of advanced therapeutics due to its enhanced specificity, efficacy, and extended half‐life. A prime example is VEGF‐Trap (Aflibercept), a recombinant fusion protein that merges the Fc region of the IgG1 subtype with the binding domains of vascular endothelial growth factor receptors (VEGFR)‐1 and VEGFR‐2. The Fc region's role in N‐glycosylation is particularly important, as it significantly influences protein stability. Herein, the first near‐physiological temperature structures of the N‐glycan‐bound Fc fragment of IgG1 subtype from a biosimilar VEGF‐Trap are presented, determined using the SPring‐8 Angstrom Compact free electron LAser (SACLA) and the Turkish Light Source (Turkish DeLight). Comparative analysis with cryogenic structures, including existing data, reveals alternate conformations within the glycan‐binding pocket. Furthermore, molecular dynamics simulations indicate the presence of a high degree of structural plasticity, explaining how the protein adapts its structure through conformational changes. The observed structural fluctuations/conformational changes demonstrate the effect of N‐glycans on protein stability. These findings offer new insights into the molecular basis of Fc‐mediated functions and provide valuable information for the design of next‐generation therapeutics.

60 APPLIED LIFE SCIENCES↗

Wavefront preserving X-ray optics for Synchrotron and Free Electron Laser photon beam transport systems

We report in the last two decades, after the first light from the new Free Electron Lasers, either in the UV (FLASH and FERMI@Elettra) or X-ray (LCLS and SACLA), more and more new diffraction limited sources have been either constructed or planned. Third generation storage rings are upgraded to provide a more collimated, brighter, and coherent light for the next generation experimental techniques. X-ray optics are the bridge between the light sources and the experimental stations. They are the key to the success of advanced experiments but also the potential bottleneck preventing the exploitation of the full characteristics of the source. The beam degradation originated by any mirror defect (either from mirror polishing or from contamination) is amplified with a coherent source. Delivering diffraction-limited spots, including the option for variable spot sizes in and out of focus, requires the control of the surface of the optics at the 1 nm rms level, if not better. At LCLS, only very recently an almost perfectly uniform beam out of focus has been obtained in the hard X-rays. It has been obtained after two 1-m long mirrors with 0.5 nm rms shape precision (after installation). Those mirrors were not readily available just a decade ago. But, thanks to the pioneering work performed at the Osaka University, those optics are now commercially available with arbitrary tangential profiles. This new generation of mirrors permits achieving unprecedented results. However, they do not remove all road blocks to a perfect photon transport system. Instead, they highlighted the critical importance of mirror mounting, handling of the thermal deformation, and the need of advanced diagnostics to properly exploit all the new potentiality of these optics. Besides the need of “perfect” mirrors, other aspects of the beamline design and elements may impact the quality of the beam in the experimental station, from the lack of blaze gratings to the need of advanced simulation tools, just to cite two. In this article, after a brief historical excursus, we will present the current state of the art of mirrors, gratings, crystals, lenses, diagnostics, and simulation tools. The main problems yet to solve and a look ahead at what would be achievable in the next decade will give the reader an idea on the search for an almost ideal photon transport system and how the path toward experiments, not conceivable today, will unfold.

47 OTHER INSTRUMENTATION↗

Nucleophilic Displacement Reactions of Silver-Based Metal–Organic Chalcogenolates

Here, we report nucleophilic displacement reactions that can increase the dimensionality or coordination number of silver-based metal–organic chalcogenolates (MOChas). MOChas are crystalline ensembles containing one-dimensional (1D) or two-dimensional (2D) inorganic topologies with structures and properties defined by the choice of metal, chalcogen, and ligand. MOChas can be readily prepared from a variety of small-molecule ligands and metals or metal ions. Although MOChas offer ligand diversity, most reported examples use relatively small ligands, typically involving short alkyl chains, aryl rings, or molecular cages. This is because larger, more complex molecules often yield poor product morphologies with indeterminate structures. In this study, we overcame this limitation by employing a ligand exchange strategy whereby a 1D MOCha, silver(I) methyl 2-mercaptobenzoate (2MMB), is used as a silver source for preparing 2D examples. The reaction proceeds generally toward products composed of the stronger nucleophile. We show that the reaction prefers displacing 1D topologies to yield 2D ones and replacing thiolates with selenolates. We performed a study to characterize the mechanism by which organic chalcogenols and dichalcogenides exchange with MOChas. The collected data and product analysis support a proposed mechanism of nucleophilic substitution, explaining how both organic chalcogenols and dichalcogenides can displace ligands in MOChas. This work provides a new synthetic route that will enable the preparation of more elaborate MOChas and heterostructures thereof. This approach enabled the preparation of previously inaccessible oligophenyl MOChas, which were successfully solved via small-molecule serial femtosecond crystallography (smSFX) at the SPring-8 Ångström Compact Free Electron LAser (SACLA) facility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evidence of shock-compressed stishovite above 300 GPa

SiO 2 is one of the most fundamental constituents in planetary bodies, being an essential building block of major mineral phases in the crust and mantle of terrestrial planets (1–10 M E ). Silica at depths greater than 300 km may be present in the form of the rutile-type, high pressure polymorph stishovite (P4 2 /mnm) and its thermodynamic stability is of great interest for understanding the seismic and dynamic structure of planetary interiors. Previous studies on stishovite via static and dynamic (shock) compression techniques are contradictory and the observed differences in the lattice-level response is still not clearly understood. Here, laser-induced shock compression experiments at the LCLS- and SACLA XFEL light-sources elucidate the high-pressure behavior of stishovite on the lattice-level under in situ conditions on the Hugoniot to pressures above 300 GPa. We find stishovite is still (meta-)stable at these conditions, and does not undergo any phase transitions. This contradicts static experiments showing structural transformations to the CaCl 2 , α-PbO 2 and pyrite-type structures. However, rate-limited kinetic hindrance may explain our observations. These results are important to our understanding into the validity of EOS data from nanosecond experiments for geophysical applications.

58 GEOSCIENCES↗

A self-referenced in-situ arrival time monitor for X-ray free-electron lasers

We present a novel, highly versatile, and self-referenced arrival time monitor for measuring the femtosecond time delay between a hard X-ray pulse from a free-electron laser and an optical laser pulse, measured directly on the same sample used for pump-probe experiments. Two chirped and picosecond long optical supercontinuum pulses traverse the sample with a mutually fixed time delay of 970 fs, while a femtosecond X-ray pulse arrives at an instant in between both pulses. Behind the sample the supercontinuum pulses are temporally overlapped to yield near-perfect destructive interference in the absence of the X-ray pulse. Stimulation of the sample with an X-ray pulse delivers non-zero contributions at certain optical wavelengths, which serve as a measure of the relative arrival time of the X-ray pulse with an accuracy of better than 25 fs. We find an excellent agreement of our monitor with the existing timing diagnostics at the SACLA XFEL with a Pearson correlation value of 0.98. We demonstrate a high sensitivity to measure X-ray pulses with pulse energies as low as 30 μJ. Using a free-flowing liquid jet as interaction sample ensures the full replacement of the sample volume for each X-ray/optical event, thus enabling its utility even at MHz repetition rate XFEL sources.

47 OTHER INSTRUMENTATION↗

Non-thermal structural transformation of diamond driven by x-rays

Intense x-ray pulses can cause the non-thermal structural transformation of diamond. At the SACLA XFEL facility, pump x-ray pulses triggered this phase transition, and probe x-ray pulses produced diffraction patterns. Time delays were observed from 0 to 250 fs, and the x-ray dose varied from 0.9 to 8.0 eV/atom. The intensity of the (111), (220), and (311) diffraction peaks decreased with time, indicating a disordering of the crystal lattice. From a Debye–Waller analysis, the rms atomic displacements perpendicular to the (111) planes were observed to be significantly larger than those perpendicular to the (220) or (311) planes. At a long time delay of 33 ms, graphite (002) diffraction indicates that graphitization did occur above a threshold dose of 1.2 eV/atom. These experimental results are in qualitative agreement with XTANT+ simulations using a hybrid model based on density-functional tight-binding molecular dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast time-resolved 2D imaging of laser-driven fast electron transport in solid density matter using an x-ray free electron laser

High-power, short-pulse laser-driven fast electrons can rapidly heat and ionize a high-density target before it hydrodynamically expands. The transport of such electrons within a solid target has been studied using two-dimensional (2D) imaging of electron-induced Kα radiation. However, it is currently limited to no or picosecond scale temporal resolutions. Here, we demonstrate femtosecond time-resolved 2D imaging of fast electron transport in a solid copper foil using the SACLA x-ray free electron laser (XFEL). An unfocused collimated x-ray beam produced transmission images with sub-micron and ~10 fs resolutions. The XFEL beam, tuned to its photon energy slightly above the Cu K-edge, enabled 2D imaging of transmission changes induced by electron isochoric heating. Time-resolved measurements obtained by varying the time delay between the x-ray probe and the optical laser show that the signature of the electron-heated region expands at ~25% of the speed of light in a picosecond duration. Time-integrated Cu Kα images support the electron energy and propagation distance observed with the transmission imaging. The x-ray near-edge transmission imaging with a tunable XFEL beam could be broadly applicable for imaging isochorically heated targets by laser-driven relativistic electrons, energetic protons, or an intense x-ray beam.

47 OTHER INSTRUMENTATION↗

Characterizing crystalline defects in single nanoparticles from angular correlations of single-shot diffracted X-rays

Characterizing and controlling the uniformity of nanoparticles is crucial for their application in science and technology because crystalline defects in the nanoparticles strongly affect their unique properties. Recently, ultra-short and ultra-bright X-ray pulses provided by X-ray free-electron lasers (XFELs) opened up the possibility of structure determination of nanometre-scale matter with Å spatial resolution. However, it is often difficult to reconstruct the 3D structural information from single-shot X-ray diffraction patterns owing to the random orientation of the particles. This report proposes an analysis approach for characterizing defects in nanoparticles using wide-angle X-ray scattering (WAXS) data from free-flying single nanoparticles. The analysis method is based on the concept of correlated X-ray scattering, in which correlations of scattered X-ray are used to recover detailed structural information. WAXS experiments of xenon nanoparticles, or clusters, were conducted at an XFEL facility in Japan by using the SPring-8 Ångstrom compact free-electron laser (SACLA). Bragg spots in the recorded single-shot X-ray diffraction patterns showed clear angular correlations, which offered significant structural information on the nanoparticles. The experimental angular correlations were reproduced by numerical simulation in which kinematical theory of diffraction was combined with geometric calculations. We also explain the diffuse scattering intensity as being due to the stacking faults in the xenon clusters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated structural dynamics uncover new modes of B12 photoreceptor activation

**SACLA** A crystallographic pump-power titration was first carried-out with pump laser fluences of 12, 30, 60 and 120 uJ.cm-2 and a time delay of 3 us. Then, a time-series was performed with a pump-laser fluence of 30 uJ.cm-2 (~2.4 absorbed photon per chromophore) and time-delays of 10 ns, 300 ns, 3 µs, 100 us and 3 ms. Finally, two time-delays (10 ns and 3 us) were collected with a pump laser fluence of 12 uJ.cm-2. Raw images, crystFEL streams and merged mtzs are available for all collected dat **SwissFEL** A time series with a pump laser fluence of 30 mJ.cm-2 was performed at time delys of 3 µs and 10 ms. Raw images, crystFEL streams and merged mtzs are available for all collected datasets. Refined detector geometry for each experimental campaign is also provided (crystFEL format)

RIOS-SANTACRUZ, Ronald↗

Integrated structural dynamics uncover new modes of B12 photoreceptor activation

**SACLA** A crystallographic pump-power titration was first carried-out with pump laser fluences of 12, 30, 60 and 120 ??J.cm-2 and a time delay of 3 ??s. Then, a time-series was performed with a pump-laser fluence of 30 ??J.cm-2 (~2.4 absorbed photon per chromophore) and time-delays of 10 ns, 300 ns, 3 ??s, 100 ??s and 3 ms. Finally, two time-delays (10 ns and 3 ??s) were collected with a pump laser fluence of 12 ??J.cm-2. Raw images, crystFEL streams and merged mtzs are available for all collected dat **SwissFEL** A time series with a pump laser fluence of 30 mJ.cm-2 was performed at time delys of 3 ??s and 10 ms. Raw images, crystFEL streams and merged mtzs are available for all collected datasets. Refined detector geometry for each experimental campaign is also provided (crystFEL format)

RIOS-SANTACRUZ, Ronald↗

X-ray Parametric Down Conversion at an XFEL

Understanding and harnessing X-ray quantum effects could open new frontiers in imaging and quantum optics. In this study, we measured the process of X-ray Parametric Down Conversion, where a single high-energy X-ray photon splits into two lower-energy photons. Using the SACLA X-ray Free Electron Laser in Japan at 9.83 keV, we found clear evidence that pairs of photons were produced along the energy-angle relationship that conserved both energy and momentum, as predicted for down-conversion, and consistent with quantum entanglement of X-ray photons. By matching specific photon pairs for energy and momentum conservation, we observe a signal rate of 1,250 pairs per hour, confirming that correlated photon pairs can be generated and observed in the absence of explicit time correlations. Our results show that with further refinement, the number of entangled photons produced per laser pulse could increase by an order of magnitude. This paves the way for demonstrating quantum-enhanced X-ray imaging, and confirmation of X-ray photon entanglement.

47 OTHER INSTRUMENTATION↗

Ultrafast probing of charge transfer dynamics with an XUV free-electron laser

We study charge transfer in dissociating molecules of 2-iodopropane (C 3 H 7 I) in a UV pump – XUV probe regime at the SACLA free-electron laser. Signatures of charge transfer from the recently dissociated iodine atom to the neutral propyl radical are observed in recorded 3D ion momentum distributions. This signature has evaded observation in previous related experiments. Detailed analysis of these signatures allows the identification of a region of internuclear separation where charge transfer occurs.

74 ATOMIC AND MOLECULAR PHYSICS↗

High Harmonic Generation Seeding Echo-Enabled Harmonic Generation toward a Storage Ring-Based Tender and Hard X-ray-Free Electron Laser

To align with the global trend of integrating synchrotron light source (SLS) and free electron laser (FEL) facilities on one site, in line with examples such as SPring-8 and SACLA in Japan and ELETTRA and FERMI in Italy, we actively explore FEL options leveraging the ultralow-emittance electron beam of the NSLS-II upgrade. These options show promising potential for synergy with storage ring (SR) operations, thereby significantly enhancing our facility’s capabilities. Echo-enabled harmonic generation (EEHG) is well-suited to SR-based FELs, and has already been demonstrated with the capability of generating extremely narrow bandwidth as well as high brightness, realized using diffraction-limited short pulses in transverse planes and Fourier transform-limited bandwidth in the soft X-ray spectrum. However, regarding a conventional EEHG scheme, the combination of the shortest seed laser wavelength (256 nm) and highest harmonic (200) sets the short wavelength limit to λ = 1.28 nm. To further extend the short wavelength limit down to the tender and hard X-ray region, a vital option is to shorten the seed laser wavelength. Thanks to recent advances in high harmonic generation (HHG), packing 10 9 photons at one harmonic within a few-femtosecond pulse could turn such a novel HHG source into an ideal seeding for EEHG. Thus, compared to the cascaded EEHG, the HHG seeding option could not only lower the cost, but also free the SR space for accommodating more user beamlines. Moreover, to mitigate the SASE background noise on the sample and detector, we combine the HHG seeding EEHG with the crab cavity short pulse scheme for maximum benefit.

36 MATERIALS SCIENCE↗

Using Diffuse Scattering to Observe X-Ray-Driven Nonthermal Melting

We present results from the SPring-8 Angstrom Compact free electron LAser (SACLA) XFEL facility, using a high intensity ($\sim\!10^{20}\,$W/cm$^2$) X-ray pump X-ray probe scheme to observe changes in the ionic structure of silicon induced by X-ray heating of the electrons. By avoiding Laue spots in the scattering signal from a single crystalline sample, we observe a rapid rise in diffuse scattering, which we attribute to a loss of lattice order and a transition to a liquid state within 100 fs of irradiation, a timescale which agrees well with first principles simulations, but is faster than that predicted by purely inertial behavior. This method is capable of observing liquid scattering without masking or filtering of signal from the ambient solid, allowing the liquid structure to be measured throughout and beyond the phase change.

Hartley, Nicholas J.↗