Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ross filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ross Filter Diode Array Analysis for Red Sage

A Ross Filter Diode Array (RFDA) diagnostic was fielded on the Cygnus x-ray source during the final stages of the Red Sage campaign. This report briefly describes the motivation for the diagnostic, its construction and operating principles, and the raw data that it produces followed by an in-depth look at the procedures used to analyze this data. RFDA signals from eight Cygnus shots conducted after the conclusion of Nightshade C are analyzed and those results are discussed. Finally, recommendations are made to improve the diagnostic for future experiments.

42 ENGINEERING↗

Imaging of high-energy x-ray emission from cryogenic thermonuclear fuel implosions on the NIF

Accurately assessing and optimizing the implosion performance of inertial confinement fusion capsules is a crucial step to achieving ignition on the NIF. We have applied differential filtering (matched Ross filter pairs) to provide broadband time-integrated absolute x-ray self-emission images of the imploded core of cryogenic layered implosions. This diagnostic measures the temperature- and density-sensitive bremsstrahlung emission and provides estimates of hot spot mass, mix mass, and pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of Inferred Electron Temperature from X-ray Emission of NIF Cryogenic DT Implosions

The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory seeks to achieve thermonuclear ignition through inertial confinement fusion. The accurate assessment of the performance of each implosion experiment is a crucial step. Here we report on work to derive a reliable electron temperature for the cryogenic deuteriumtritium implosions completed on the NIF using the xray signal from the Ross filter diagnostic. These Xrays are dominated by bremsstrahlung emission. By fitting the xray signal measured through each of the individual Ross filters, the source bremsstrahlung spectrum can be inferred, and an electron temperature of the implosion hot spot inferred. Currently, each filter is weighted equally in this analysis. We present work quantifying the errors with such a technique and the results from investigating the contribution of each filter to the overall accuracy of the temperature inference. Using this research, we also compare the inferred electron temperature against other measured implosion quantities to develop a more complete understanding of the hotspot physics.

42 ENGINEERING↗

Pseudomonoenergetic x-ray diffraction measurements using balanced filters for coherent-scatter computed tomography

Coherent-scatter computed tomography (CSCT) is a method of ''composition'' imaging based on measurements of diffraction patterns from tissues. Use of an x-ray tube degrades scatter pattern angular resolution due to the x-ray spectral width, making it difficult to uniquely identify some materials. The use of two transmission filters with similar atomic numbers (balanced ''Ross filters'') to generate pseudomonoenergetic scatter patterns is described as it applies to CSCT. An analysis of angular-blur mechanisms reveals that focal spot size and beam width are the most important factors determining Bragg-peak width when Er-Tm filters are used. A relative RMS spectral width of 1% can be achieved in the difference spectrum and a Bragg-peak RMS angular width of approximately 0.14 deg. (relative width of 3% at 5 deg. scatter angle) can be achieved with an effective energy of 58 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and fabrication of a multi-purpose soft x-ray array diagnostic system for KSTAR

A multi-purpose soft x-ray array diagnostic system was developed for measuring two-dimensional x-ray emissivity profile, electron temperature, Ar impurity transport, and total radiation power. A remotely controlled filter wheel was designed with three different choices of filters. The electron temperature profile can be determined from the ratio of two channels having different thickness of Be layer, and the Ar impurity concentration transport can be determined from a pair of Ar Ross filters (CaF{sub 2} and NaCl thin films). Without any filters, this diagnostic system can also be used as a bolometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a short duration backlit pinhole for radiography on the National Ignition Facility

Experiments on the National Ignition Facility (NIF) will require bright, short duration, near-monochromatic x-ray backlighters for radiographic diagnosis of many high-energy density systems. This paper details a vanadium pinhole backlighter producing (1.8{+-}0.5)x10{sup 15} x-ray photons into 4{pi} sr near the vanadium He-like characteristic x-ray energy of 5.18 keV. The x-ray yield was quantified from a set of Ross filters imaged to a calibrated image plate, with the Dante diagnostic used to confirm the quasimonochromatic nature of the spectrum produced. Additionally, an x-ray film image shows a source-limited image resolution of 26 {mu}m from a 20 {mu}m diameter pinhole.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband and filter radiometers at Ross Island, Antarctica: detection of cloud ice phase versus liquid water influences on shortwave and longwave radiation

Abstract. Surface radiometer data from Ross Island, Antarctica, collected during the austral summer 2015–2016 by the US Department of Energy Atmospheric Radiation Measurement (ARM) program West Antarctic Radiation Experiment (AWARE), are used to evaluate how shortwave and longwave irradiance respond to changing cloud properties as governed by contrasting meteorological regimes. Shortwave atmospheric transmittance is derived from pyranometer measurements, and cloud conservative-scattering optical depth is derived from filter radiometer measurements at 870 nm. With onshore flow associated with marine air masses, clouds contain mostly liquid water. With southerly flow over the Transantarctic Mountains, orographic forcing induces substantial cloud ice water content. These ice and mixed-phase clouds attenuate more surface shortwave irradiance than the maritime-influenced clouds and also emit less longwave irradiance due to colder cloud base temperature. These detected irradiance changes are in a range that can mean onset or inhibition of surface melt over ice shelves. This study demonstrates how basic and relatively low-cost broadband and filter radiometers can be used to detect subtle climatological influences of contrasting cloud microphysical properties at very remote locations.

54 ENVIRONMENTAL SCIENCES↗

NSRD-20, Functional Testing of Novel MTC HEPA Filtration Media

To improve the safety of Department of Energy (DOE) nuclear facilities, this project aimed to develop ceramic high efficiency particulate air (HEPA) filters that also create a low pressure-drop (dP) in use. The filters under consideration use mini-tubular ceramic (MTC) HEPA filtration media made with different architectures. Once successful, this project will reduce life-cycle costs, including safety basis, operational, and waste-disposal costs. The technology’s mini-tubular geometry is known to reduce dP when compared to flow through membranes of equivalent mass and surface area. Low dP facilitates retrofitting advanced filters into existing DOE facilities to make them safer while simultaneously reducing operational costs. Operations of ventilation systems are a key cost driver for DOE nuclear facilities; reducing dP can significantly reduce DOE’s operational costs. However, the filtration efficiency (FE) of this type of filtration media depends on the architecture of the filter media in an unknown way and requires testing. Functional testing of filtration media with different architectures will establish the performance of the filtration media and will enable development of guidance on design requirements to optimize filter performance.

36 MATERIALS SCIENCE↗

Removing Rotational Variations from Shoulder Thermocouples in Friction Stir Welding

Thick plate and lower temperature friction stir welding results in good post-weld properties by welding at very low tool rotational speeds. Low speeds cause large variations in the measured shoulder temperature, making temperature control difficult. This paper describes a computationally light method to correct for oscillating measured temperatures. Data is collected over the previous two revolutions and used to build a compensation table and calculate a derivative. In simulation, measured temperature variations are reduced by a factor of five to ten. Temperature data is preserved and not cornered, nor is any time delay induced by this method, unlike with filtering methods.

Friction Stir Welding, Temperature↗

ARM West Antarctic Radiation Experiment (AWARE) Fourier Transform Infrared Filter Sampling Systems Field Campaign Report

West Antarctica is one of the most rapidly warming regions in the world (Bromwich et al. 2013; Steig et al. 2009) and the warming can directly cause sea level rise (King et al. 2012). In situ measurements are needed to examine and quantify the meteorological conditions in order to precisely understand the effect of warm air and clouds on the West Antarctic Ice Shelf (WAIS). The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE) is designed to collect measurements with advanced cloud and aerosol instrumentation at West Antarctica. The Fourier Transform Infrared (FTIR) filter sampling systems were deployed as part of the ARM West Antarctic Radiation Experiment (AWARE) campaign to measure organic aerosol characteristics at McMurdo Station. As a coastal station at the southern end of Ross Island, McMurdo Station has a meteorological relationship with the WAIS via circulation patterns in the Ross and Amundsen Seas. Thirteen months of continuous observations of aerosol particle composition extended from December 2016 to January 2017. Filter samples were collected at McMurdo on pre-scanned Teflon filters (Teflon, Pall Inc., 37mm diameter) behind PM1 sharp-cut cyclones (SCC2.229 PM1, BGI Inc). Samples were collected each week with approximately 50-90 m3 air filtered per sample. Samples were frozen and transported below 0°C to the Scripps laboratory for FTIR spectroscopy analysis. A Bruker Tensor 27 FTIR spectrometer with a deuterated triglycine sulfate (DTGS) detector (Bruker, Waltham, MA) was used to scan the filters both before and after sampling. An automated algorithm (Takahama et al. 2013) was applied to quantify the mass of the organic functional groups. Four groups (alkane, amine, alcohol, and carboxylic acid) had absorption peaks above the limits of quantification, and the sum of the mass of the four functional groups is the quantified organic mass (OM). Absorption peaks for other groups (organosulfate, organonitrate, aromatic, and alkene group) were identified and fit but they were below the limit of quantification for more than 90% of the samples and are excluded. Similar FTIR measurements has been conducted in dozens of field campaigns around the world, including arctic regions (Russell et al. 2011). Local particle emissions from airports, diesel generators, and local transportation affected all aerosol measurements at various times during this project. The ARM Aerosol Measurement Science Group is aware of the issue and is working to develop algorithms to flag the data. This influence is evident in the FTIR measurements as it is associated with specific chemical signatures. DOE and the National Science Foundation, which manages the U.S. Antarctic Program, supported this collaboration for AWARE.

ARM West Antarctic Radiation Experiment, Fourier T↗

A Strategy for Forced Oscillation Suppression

Wide-area time-synchronized measurements have recently revealed troublesome forced oscillations (FOs) within modern synchronized power grids. In some cases, these FOs represent a dangerous hazard to the system. Recent research has focused on locating the source of FOs to provide operators with knowledge for mitigating their impact locally. This paper presents a complementary mitigation strategy, which is to purposely induce a second oscillation into the grid which cancels the impact of the FO. Such a strategy is complementary in that it may provide valuable time to operators attempting to locate the FOs source and to determine how to rectify it. This paper presents a suppression control strategy which modulates controllable devices to automatically cancel the impact of the FO without the need for locating the source of the original FO. The strategy is based upon tuned feedback control. In this study, the approach is demonstrated on a simulation system via modulation of inverter-based generation.

42 ENGINEERING↗

Ceramic High Efficiency Particulate Air (HEPA) Filter Research and Development at Lawrence Livermore National Laboratory

Ceramic high efficiency particulate air (HEPA) filter development program began at Lawrence Livermore National Laboratory (LLNL) over 20 years ago. Historical incidents motivated current safety systems at nuclear facilities. A ceramic filter that can survive a fire can provide robust, passive safety protection. Research has been conducted to improve the safety of nuclear facilities and to reduce operational and lifecycle costs, through ceramic filter technology that can survive fire conditions. Here, the research focused on applications in both new facilities as well as meeting operational requirements necessary to retrofit filters into existing DOE facilities. The research has developed multiple filter technologies spanning traditional HEPA filter materials to advanced manufacturing technologies (e.g., electrospinning, additive manufacturing, etc.). This communication will present highlights of selected development efforts for ceramic HEPA filter research, current state-of-the-art for ceramic filters, and future needs including technical, regulatory, and commercial efforts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-energy x-ray backlighter spectrum measurements using calibrated image plates

The x-ray spectrum between 18 and 88 keV generated by a petawatt laser driven x-ray backlighter target was measured using a 12-channel differential filter pair spectrometer. The spectrometer consists of a series of filter pairs on a Ta mask coupled with an x-ray sensitive image plate. A calibration of Fuji{trademark} MS and SR image plates was conducted using a tungsten anode x-ray source and the resulting calibration applied to the design of the Ross pair spectrometer. Additionally, the fade rate and resolution of the image plate system were measured for quantitative radiographic applications. The conversion efficiency of laser energy into silver K{alpha} x rays from a petawatt laser target was measured using the differential filter pair spectrometer and compared to measurements using a single photon counting charge coupled device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EGS Collab Experiment 2: Continuous Broadband Seismic Waveform Data

Two broadband seismometers were installed on the 4100 level and recorded for the duration of EGS Collab Experiment #2. Inspired by published data from similar instruments installed in the Aspo Hard Rock Lab, these long-period instruments aimed to measure the tilting of the drift in response to the injection of fluid into the testbed. One instrument was installed underneath the wellheads in Site A (aka the "battery" alcove) and the other was installed along the east wall of the drift, south of Site B. Due to the feet of gravel (ballast) laid along the floor of the drift, we were unable to anchor the sensors directly to the rock. As a result, the coupling of the sensors to the experiment rock volume is likely poor. In addition, there are a number of noise sources that complicate the interpretation of the data. For example, sensor BBB is installed adjacent (within 3 ft) to the rail line that runs towards the Ross shaft. Trains (motors) run along this line almost daily and produce a large signal in these data. Careful extraction of periods of interest, as well as filtering for specific signals, is necessary. The sensors are Nanometrics Trillium Compact Posthole seismometers, sensitive down to 120 seconds period. They were installed as close to the drift wall and as deep as we could manually excavate (only about 1 ft or so). The holes were leveled with sand and the sensors were placed on a paver before backfilling with sand. The hole was then covered by a bucket filled with insulation to improve the sensor's isolation from daily temperature variations, which are minor but present due to drift ventilation from the surface. Data were recorded on Nanometrics Centaur digitizers at 100 Hz. The full response information is available in the StationXML file provided here, or by querying the sensors through the IRIS DMC (see links below). These instruments were provided free of charge through the IRIS PASSCAL instrument center. The network code is XP and the station codes are BBA and BBB. The waveform data can be queried through the IRIS FDSN server using any method the user likes. One convenient option is to use the Obspy python package: https://docs.obspy.org/packages/obspy.clients.fdsn.html

15 GEOTHERMAL ENERGY↗