Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Roof Top Unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

What's in a Name? Developing a Standardized Taxonomy for HVAC System Faults

Faults occurring in heating, ventilation and air-conditioning (HVAC) systems have significantly negative impacts on building energy consumption, occupant comfort, and indoor air quality. In the past thirty years, extensive research has been conducted on fault detection and diagnostics (FDD) methods, and there are now dozens of commercially available FDD software tools. Growing adoption of FDD tools has the potential to generate a massive and useful data set on fault characteristics. However, the lack of a unifying taxonomy is a significant barrier to efficient analysis and evaluation of FDD outputs. Therefore, there is a strong need to develop a robust taxonomy which can better represent and interpret FDD output data. This paper documents the development of a unifying taxonomy for HVAC system faults in commercial buildings, with initial focus on air handling units, variable air volume terminal units, and roof top unit systems. The developed fault taxonomy employs both a physical hierarchy of HVAC equipment and a cause-effect relationship model as tools to better understand and support root cause analysis for HVAC faults. A variable air volume terminal unit is used as an example to demonstrate the application of the developed fault taxonomy. The taxonomy has short-term application in a major U.S. study on fault prevalence, and promises longer term benefits to FDD software developers and building operators by creating a foundation for improved approaches to identifying and resolving HVAC faults.

Chen, Yimin↗

High Efficiency Low Global Warming Potential Compressor

During this project UTRC designed a novel compressor for use with new low Global-Warming-Potential (GWP) refrigerants. Through two design and testing iterations, UTRC advanced the compressor technology from TRL3 to TRL5. The target application was a 5 Tons of Refrigeration (TR) capacity Roof-Top Unit (RTU), although this technology may be applied to other low-capacity systems such as residential. The prototype unit met all design goals at the ARI-A rating condition and requires high efficiency motor to meet high performance targets at the ARI-B condition. This technology may be used in high efficiency units and with seasonal energy efficiency rating (SEER) exceeding 20. A preliminary cost analysis estimated that there would be less than $25/kbtuh cost impact to the customer.

30 DIRECT ENERGY CONVERSION↗

Empirical Modeling of Direct Expansion (DX) Cooling System for Multiple Research Use Cases

This study provides a general procedure to generate a direct expansion (DX) cooling coil system for a roof top unit (RTU), which is a typical heating ventilation and air-conditioning (HVAC) system for commercial buildings in the United States. Experimental data from a full-scale unoccupied 2-story commercial building is used for the HVAC modeling. The regression for identifying the model coefficients was carried out with multiple stages, and the results were validated with measured data. The model’s applicability was evaluated with multiple case studies, including a building energy simulation (BES) program validation, model-based predictive control (MPC), and fault diagnostics and detection (FDD).

42 ENGINEERING↗

Field test and simulation evaluation of variable refrigerant flow systems performance

Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. The same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating operation. As a result, energy consumption of the VRF system was reduced by more than that of the RTU by 55% approximately.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of flammable volume in the case of a catastrophic leak of R-32 from a rooftop unit

With the effort to use alternative refrigerants with lower global warming potential (GWP), the majority of these alternative refrigerants are classified as slightly flammable. Here in this paper we report on the numerical evaluation of a catastrophic leak scenario of R-32 refrigerant from a 3-ton roof top air conditioning unit (RTU) which serves a 12.2 × 9.14 × 2.4 m room. A full rupture of a 6.35 mm (¼ inch) pipe downstream of the evaporator coil is simulated. Two separate cases with refrigerant releases of 1.81 kg and 3.62 kg charge have been studied. The two charges are released in 10.2 and 20.4 s, respectively, just after the end of a unit cooling cycle. The flammable volume inside the room existed only for about 40 s with a maximum flammable volume inside the room of 1.12% of the total room volume for the 3.62 kg charge case.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced HVAC System for Smart Grid

Rocky Research (Boulder City, NV) has developed an advanced roof top air conditioning unit (RTU) with the potential for providing smart grid functions such as regulation services and PV integration. The RTU contains advanced technologies that have been demonstrated to enable 1) improved coefficient of performance (COP) during start-up transients, 2) improved steady-state efficiency, and 3) blending of DC and AC power with high conversion efficiency. Technologies incorporated by Rocky Research include a pulsing thermal expansion valve (PTXV) to dynamically optimize refrigerant flow, a variable frequency drive (VFD) for the compressor, and on-board integrated power conversion electronics for inverting and blending DC and AC power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Issaquah Highlands Zero Energy Affordable Housing (WA) - YWCA

The YWCA Family Village at Issaquah, Net Zero Energy Approach Project provides a compelling model for how the nation can seriously respond to the critical need for affordable housing while advancing environmental standards and reducing economic inequities. Affordable housing developments for vulnerable members of the community and in today's workforce cannot overlook issues, such as climate impact, energy security and water conservation. This project's advanced building design was based on the goal of creating a 100 year building that could achieve net zero energy usage if funding had been available to support the final pieces of energy generation. The team worked closely with community stakeholders to ensure the baseline components of high quality and efficient building envelopes along with efficient systems were in place to set the stage for future incorporation of energy generating systems such as solar panels. As built, these 146 homes, large child care center and community services areas are proving the value of investing upfront for the benefit of future generations by reducing ongoing utility and maintenance costs with an eye toward environmental stewardship and community/resident education. The DOE award helped fund two critical energy conservation features for the YWCA Family Village at Issaquah campus: 1) super-insulated roof assembly with a continuous air barrier and 2) domestic hot water preheat system. The roof system at the YWCA Family Village at Issaquah project was built to include 6" of Polyiso rigid insulation (R-38) on top of the roof sheathing to provide a super-insulated roof in line with the other green features of the project. Placing the rigid insulation on top of the roof sheathing allows the building to have a continuous layer of insulation and provides a continuous air barrier. The domestic hot water preheat system includes flat panel arrays on roofs of the buildings that heat the water using solar power, which reduces the amount of heating needed from the gas-fired boilers. The flat-plate panels on the roof of the building heats the water using solar power. A heat exchanger transfers heat from water warmed by the panels to potable water for the units. The warmed potable water mixes with the tap water supply to create hot water for the buildings. This boost of water warmed by the solar panels reduces the heating costs for eh project by reducing the need to heat the water via gas-fired boilers. Both of these energy upgrades were chosen because they significantly improve the energy efficiency for the life of the building and are reducing monthly utility costs for both the residents and the owners. Since the owner is a not-for-profit dedicated to long-term ownership and serving households with very-low and low-incomes, the costs savings will ultimately benefit current and future residents as the dollars saved will either be realized directly by the resident or be invested in the project. Technically, the design of these systems is easily understood and the principles could be applied to other projects. The incremental costs depend largely on the existing market rate of the components-none of which are considered "cutting edge" so a market does currently exist.

14 SOLAR ENERGY↗

Small Business Voucher CRADA Report: Natural Gas Powered HVAC System for Commercial and Residential Buildings

Be Power Tech is commercializing BeCool, the first integrated electricity-producing heating, ventilation, and air conditioning (HVAC) system using a non-vapor compression cycle (VCC), packaged rooftop HVAC unit that also produces base-load electricity, heating, ventilation, and air conditioning. BeCool is a distributed energy resource with energy storage that eliminates the tremendous peak electricity demand associated with commonly used electricity-powered vapor compression air conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pecan Street Grid Demonstration Program. Final technology performance report

This document represents the final Regional Demonstration Project Technical Performance Report (TPR) for Pecan Street Inc.’s (Pecan Street) Smart Grid Demonstration Program, DE-OE-0000219. Pecan Street is a 501(c)(3) smart grid/clean energy research and development organization headquartered at The University of Texas at Austin (UT). Pecan Street worked in collaboration with Austin Energy, UT, Environmental Defense Fund (EDF), the City of Austin, the Austin Chamber of Commerce and selected consultants, contractors, and vendors to take a more detailed look at the energy load of residential and small commercial properties while the power industry is undergoing modernization. The Pecan Street Smart Grid Demonstration Program signed-up over 1,000 participants who are sharing their home or businesses’s electricity consumption data with the project via green button protocols, smart meters, and/or a home energy monitoring system (HEMS). Pecan Street completed the installation of HEMS in 750 homes and 25 commercial properties. The program provided incentives to increase the installed base of roof-top solar photovoltaic (PV) systems, plug-in electric vehicles with Level 2 charging, and smart appliances. Over 200 participants within a one square mile area took advantage of Austin Energy and Pecan Street’s joint PV incentive program and installed roof-top PV as part of this project. Of these homes, 69 purchased or leased an electric vehicle through Pecan Street’s PV rebate program and received a Level 2 charger from Pecan Street. Pecan Street studied the impacts of these technologies along with a variety of consumer behavior interventions, including pricing models, real-time feedback on energy use, incentive programs, and messaging, as well as the corresponding impacts on Austin Energy’s distribution assets.The primary demonstration site was the Mueller community in Austin, Texas. The Mueller development, located less than three miles from the Texas State Capitol, is a 711-acre LEED Neighborhood Development mixed-use, urban infill redevelopment on the site of Austin’s former airport, currently under development through a public-private project between the City of Austin, and Catellus Austin LLC. Currently, Mueller is less than 50% complete and more than 3,500 people live or work at Mueller. At full build-out, the project will include more than 3 million square feet of commercial and institutional space, more than 13,000 residents from approximately 5,700 single-family and multi-family dwelling units. Figure 1 shows a Google Map image of the Mueller community, zoomed in on the residential streets participating in the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bringing Fault Detection and Diagnostics (FDD) Tools into the Mainstream: Retro Commissioning and Continuous Commissioning of HVAC and Refrigeration Systems

HVAC systems in the commercial building sector consume about 3.4 quads of energy annually. Of all the HVAC systems, packaged rooftop air–conditioning units (RTUs) provide cooling and heating for over 60 percent of the commercial building floorspace (about 90 billion ft2) in the U.S. and they are a significant source of energy consumption and peak demand. All HVAC systems suffer from faults that impact thermal comfort and increase energy consumption. There are several commercially available Automated Fault Detection and Diagnostic (AFDD) tools on the market that can detect and diagnose faults, and if those faults are corrected, can save significant national energy. However, there are multiple market barriers for these tools including lack of independent verification of their performance in the field in terms of their technical capabilities, ease of use and installation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The SURE House (Solar Decathlon 2015)

Coastal towns and cities across the Northeastern US, with their high population density, aged utility infrastructure, and unique geography, are increasingly vulnerable to climate change related storm events. In October 2012 superstorm Sandy highlighted the fragility of our current coastal building types and made clear the need for a new model of design and construction which works to understand and mitigate these weaknesses. Dramatic changes in public policy, championed by both The Federal Emergency Management Agency (FEMA) and the National Flood Insurance Program (NFIP) are driving the rebuilding of these shore communities, often resulting in costly renovations, un-sustainable neighborhood configurations and in direct conflict with concurrent government policies such as The American with Disabilities Act (ADA). The SURE HOUSE demonstrates a series of new design solutions to these conflicting public policies and environmental imperatives. At Stevens Institute of Technology, the 2015 Solar Decathlon started with the challenge: Can we design a home for coastal New Jersey that dramatically reduces its energy use while protecting itself from the realities of a changing, more extreme climate? The SURE HOUSE merges the iconic 20th century shore home with 21st century building science. Utilizing innovative renewable energy technologies, a ‘Passive House’ level building envelope, and rugged glass-fiber-composite materials to flood-proof the home, the SURE HOUSE is a high-performance, net-zero-energy home, armored against extreme weather, designed for the contemporary lifestyle of the Jersey Shore and other vulnerable coastal communities. SUSTAINABLE At Stevens, we recognize that energy use in the home and workplace is directly connected to the growing problem of climate change. Reducing our energy consumption by designing higher performing, compact homes that are both functional, comfortable and desirable is the first critical step towards a modern, sustainable architecture for New Jersey and beyond. This is what informed the architectural design of the house. Configured about a compact form, thickly insulated and air-sealed walls eliminate thermal bridging and minimize energy losses while advanced glazing brings in free solar heat during the winter months. As a result of these passive design strategies, the SURE HOUSE has a greatly reduced carbon footprint requiring 91% less energy than a typical New Jersey home. Photovoltaic (PV) arrays on both the rooftop and operable shutters easily provide energy in excess of the home’s modest demands. The Stevens team considers a truly sustainable home in the era of climate change, one that prioritizes low energy use, and integrates right-sized renewable generation to supply the home’s needs. Low consumption, low production. RESILIENT In October of 2012, Hurricane Sandy wreaked havoc along the east coast of the US. In New Jersey alone there was an estimated 29.4 billion dollars in damages, 346,000 homes affected, and almost two and a half million people left without power, in some cases for over 10 days. Recovery from this storm and associated flooding is ongoing to this day, as many New Jersey homeowners grapple with the large costs of rebuilding and struggle to adapt to complicated new home building regulations. Damage from this storm to Hoboken, the home of the Stevens Institute of Technology’s campus, and to the New Jersey shore was extensive and many students on the SURE HOUSE team were directly affected by this historic event. The Stevens design team recognizes that in a world of more frequent and stronger storms, the ability to absorb and adapt to change is more important than ever. Successfully weathering the next storm and its aftermath is one of the primary goals in the design of the SURE HOUSE prototype. The SURE HOUSE introduces unique ‘dry flood-proofing’ methods to residential construction. Innovative wall and floor flood-proofing, utilizing durable composite sheathing materials adapted from the boating industry, were developed by the student team to render the SURE House’s building envelope flood proof up to the FEMA AE 6/7 Zone (+ 6/7 feet of water above sea-level). Designed and fabricated utilizing glass-fiber composite materials, the custom storm shutter system serves to protect the large glazed openings of the home from both air-borne debris impact and water infiltration during a storm event while also providing deterrence from the vandalism that often occurs in the aftermath of a calamitous event. During extended power outages, a ‘resilient’ solar array is capable of supplying critical amounts of energy and hot water to the home, without the use of battery storage or grid infrastructure. PV Description AC GRID-TIED PV SYSTEM The SURE HOUSE solar system consists of two distinct arrays, the grid-tied rooftop array which produces AC Powerand the shutter-mounted array which converts DC power generated by the modules directly into usable heat for the domestic hot water (DHW). The roof-mounted AC grid-tied array is comprised of three strings, two 11 module strings connected to an SMA SB 5000TL-US-223 inverter and a single 10 module string equipped and an SMA SB 3000TL-US-22 central inverter. All modules for the rooftop AC array are LG MonoX 2804 watt solar panels, chosen for their durability and efficiency. Inverter sizing and string size are optimized to the electrical characteristics of the chosen PV modules and the desired energy production, see Appendix 5B. The SURE HOUSE is projected to produce 12,353 kWh per year to meet 6,157 kWh per year of estimated consumption. Solar modules for the two AC grid-tied sub arrays are mounted on the main roof surface of the SURE HOUSE with a 10 degree tilt angle using a partially-ballasted polyethylene roof mounting system made by Renusol, which is particularly suited to the corrosive salt air of a coastal environment. This method was chosen for its installation simplicity and to limit detrimental roof penetrations. The 10 degree tilt optimizes the energy generated per roof area at a lower price, see Appendix 5A, and ensures that there is minimal wind uplift. DC SOLAR ELECTRIC DOMESTIC HOT WATER The SURE HOUSE’s approach to sustainable and resilient domestic hot water (DHW) consists of a unique, custom engineered DC solar electric hot water system. Employing the use of Advanced Energy’s DC electric PV heater (DCPVH)5 to heat domestic water well beyond the draw temperature, the SURE HOUSE is able to obtain a remarkably high solar fraction of 75% or more. The custom modified 80 gallon Vaughn DHW tank acts as a large solar ‘battery’ that stores heat energy in the form of hot water at almost 150 degrees, harvesting energy when the sun is out for use later in the day or overnight. The system, which uses electricity rather than heated fluid, is distinct from traditional ‘solar thermal’ systems by eliminating the dangers and associated maintenance issues of fluid based systems. By forgoing the use of external fluid loops, overheated solar collectors and pipes are not an issue for the SURE HOUSE system which never needs any yearly or seasonal flushing. In weather conditions where the integrated DCPVH unit cannot produce enough hot water via solar energy alone, the Vaughn hot water tank comes factory made with an AC powered 2.6 COP heat pump and a AC heating coil that serve as back-up heating elements. The DCPVH is powered by a DC array consisting of 10 custom-made Solbian by PVilion 180 watt, monocrystalline, flexible solar modules6. The Solbian modules are directly mounted to the top half of the operable storm shutters on the south façade of the SURE HOUSE. The SURE HOUSE team worked closely with PVillion, a PV system designer specializing in flexible architectural photovoltaics, to design an adhesive system that works with the glass-fiber storm shutter surface in a reliable manner over an extended period. Because this system operates in DC-only mode and never connects to the municipal power grid, the system can continue to create hot water safely and effectively even during grid disruption events. This hot water, and the energy stored within it, could be used for a range of activities including washing and cooking to more elaborate hydronic heating systems as desired. See Appendix 6 for system engineering, sizing and modeling.

14 SOLAR ENERGY↗

Sensing Electrical Networks Securely & Economically (SENSE)

The growing adoption of distributed energy resources (DERs) like battery energy storage systems and roof top solar/PV and the rapid penetration of electric vehicles (EVs), the electric grid is undergoing a major transformation with elevated stress on legacy grid assets. Despite a lot of expenditure to address these challenges, both in dollars and manpower, utilities have not been able to receive the value that was promised. The gains have been most visible at the transmission and substation level, especially where the main objective was improving operational and economic efficiency for the utility. Improving visibility and control at a few select points enhances the existing and established paradigm of centralized command and control. With changing load patterns, load types and the overall transition to an “active grid”, the centralized control and coordination paradigm gets challenged. To address the challenges, a new architecture and mechanism is needed, one that supports decentralized control and decision making, extracting value streams at the grid edge, particularly as the changes are fueled by transitions occurring in the distribution system. To address this, a communications and data processing platform, “GAMMA” was developed and demonstrated through the project. At the heart of the platform, are distributed, intelligent edge nodes with sensing and compute capabilities, that can record and analyze information locally. They are embedded in sensors and actuators specific to different distribution system applications. Phase 1 of the project focused on developing novel sensor technology that can be used for monitoring utility pole top distribution transformers. The sensors were designed with the objective of being low-cost, communicating with the GAMMA cloud using novel “delay-tolerant” networking using Bluetooth and a secure mobile application. They were non-intrusive in nature so that they can be installed quickly in the field, resulting in overall low cost of deployment and operations. Following the successful completion of Phase 1, the team manufactured 100 units for a field demonstration in Phase 2. The field demonstration was carried out on two real feeder systems with the local utility partner. In total, 100 sensors were installed and operated over a period of 6 months in the state of Georgia. The platform is operational end to end, with the cloud infrastructure deployed on a distributed, serverless environment that can serve multiple data streams, an analytics engine and a portal to securely view the data from multiple assets. The data collected through the GAMMA Mobile Phone app showcased the viability of the novel delay tolerant networking architecture, and the data processing algorithms developed through the course of the project, were successful in extracting important information about the overall network, improving the utility’s visibility and situational awareness in the distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Leave-in-Place Slab Edge Insulating Form System

Concrete slabs represent the primary foundation type in residential buildings in the fast-growing markets throughout the southern and southwestern United States. Nearly 75% of the 2005 U.S. population growth occurred in these southern tier states. Virtually all of these homes have uninsulated slab perimeters that transfer a small, but steady, flow of heat from conditioned space to outdoors during the heating season. It is estimated that new home foundations constructed each year add 0.016 quads annually to U.S. national energy consumption; we project that roughly one quarter of this amount can be attributed to heat loss through the slab edge and the remaining three quarters to deep ground transfers, depending upon climate. With rising concern over national energy use and the impact of greenhouse gas emissions, it is becoming increasingly imperative that all cost-effective efforts to improve building energy efficiency be implemented. Unlike other building envelope components that have experienced efficiency improvements over the years, slab edge heat loss has largely been overlooked. From our vantage point, a marketable slab edge insulation system would offer significant benefits to homeowners, builders, and the society as a whole. Conventional slab forming involves the process of digging foundation trenches and setting forms prior to the concrete pour. Conventional wood form boards (usually 2 x 10's) are supported by vertical stakes on the outer form board surface, and by supporting 'kickers' driven diagonally from the top of the form board into soil outside the trench. Typically, 2 x 10's can be used only twice before they become waste material, contributing to an additional 400 pounds of construction waste per house. Removal of the form boards and stakes also requires a follow-up trip to the jobsite by the concrete subcontractor and handling (storage/disposal) of the used boards. In the rare cases where the slab is insulated (typically custom homes with radiant floor heating), the most practical insulation strategy is to secure rigid foam insulation, such as Dow Styrofoam{trademark}, to the inside of the wooden slab edge forms. An alternative is to clad insulation to the perimeter of the slab after the slab has been poured and cured. In either case, the foam must have a 'termite strip' that prevents termites from creating hidden tunnels through or behind the foam on their way to the wall framing above. Frequently this termite strip is a piece of sheet metal that must be fabricated for each project. The above-grade portion of the insulation also needs to be coated for appearance and to prevent damage from construction and UV degradation. All these steps add time, complexity, and expense to the insulating process.

09 BIOMASS FUELS↗