Nonlinear model predictive control and H robust control for a post-combustion CO2 capture process
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not provided.
Integrated control of the toroidal current density profile, or alternatively the q-profile, and plasma stored energy is essential to achieve advanced plasma scenarios characterized by high plasma confinement, magnetohydrodynamics stability, and noninductively driven plasma current. The q-profile evolution is closely related to the evolution of the poloidal magnetic flux profile, whose dynamics is modeled by a nonlinear partial differential equation (PDE) referred to as the magnetic-flux diffusion equation (MDE). The MDE prediction depends heavily on the chosen models for the electron temperature, plasma resistivity, and non-inductive current drives. To aid control synthesis, control-oriented models for these plasma quantities are necessary to make the problem tractable. However, a relatively large deviation between the predictions by these control-oriented models and experimental data is not uncommon. For this reason, the electron temperature, plasma resistivity, and non-inductive current drives are modeled for control synthesis in this work as the product of an “uncertain” reference profile and a nonlinear function of the different auxiliary heating and current-drive (H&CD) source powers and the total plasma current. The uncertainties are quantified in such a way that the family of models arising from the modeling process is able to capture the q-profile and plasma stored energy dynamics from a typical EAST shot. A control-oriented nonlinear PDE model is developed by combining the MDE with the “uncertain” models for the electron temperature, plasma resistivity, and non-inductive current drives. This model is then rewritten into a control framework to design a controller that is robust against the modeled uncertainties. The resulting controller utilizes EAST's H&CD powers and total plasma current to regulate the q profile and plasma stored energy even when mismatches between modeled and actual dynamics are present. The effectiveness of the controller is demonstrated through nonlinear simulations.
Variable neural adaptive robust control strategies are proposed for the output tracking control of a class of multi-input multi-output uncertain systems. The controllers incorporate a variable-structure radial basis function (RBF) network as the self-organizing approximator for unknown system dynamics. The variable-structure RBF network solves the problem of structure determination associated with fixed-structure RBF networks. It can determine the network structure on-line dynamically by adding or removing radial basis functions according to the tracking performance. The structure variation is taken into account in the stability analysis of the closed-loop system using a switched system approach with the aid of the piecewise quadratic Lyapunov function. The performance of the proposed variable neural adaptive robust controllers is illustrated with simulations.
This paper presents a systematic approach to the multivariable robust control of a hybrid fuel cell gas turbine plant. The hybrid configuration under investigation comprises a physical simulation of a 300kW fuel cell coupled to a 120kW auxiliary power unit single spool gas turbine. The facility provides for the testing and simulation of different fuel cell models that in turn help identify the key issues encountered in the transient operation of such systems. An empirical model of the facility consisting of a simulated fuel cell cathode volume and balance of plant components is derived via frequency response data. Through the modulation of various airflow bypass valves within the hybrid configuration, Bode plots are used to derive key input/output interactions in Transfer Function format. A multivariate system is then built from individual transfer functions, creating a matrix that serves as the nominal plant in an H-Infinity robust control algorithm. The controller’s main objective is to track and maintain hybrid operational constraints in the fuel cell’s cathode airflow, and the turbo machinery states of temperature and speed, under transient disturbances. This algorithm is then tested on a Simulink/MatLab platform for various perturbations of load and fuel cell heat effluence.
This work presents a systematic approach to the multivariable robust control of a hybrid fuel cell gas turbine plant. The hybrid configuration under investigation built by the National Energy Technology Laboratory comprises a physical simulation of a 300kW fuel cell coupled to a 120kW auxiliary power unit single spool gas turbine. The public facility provides for the testing and simulation of different fuel cell models that in turn help identify the key difficulties encountered in the transient operation of such systems. An empirical model of the built facility comprising a simulated fuel cell cathode volume and balance of plant components is derived via frequency response data. Through the modulation of various airflow bypass valves within the hybrid configuration, Bode plots are used to derive key input/output interactions in transfer function format. A multivariate system is then built from individual transfer functions, creating a matrix that serves as the nominal plant in an H{sub {infinity}} robust control algorithm. The controller’s main objective is to track and maintain hybrid operational constraints in the fuel cell’s cathode airflow, and the turbo machinery states of temperature and speed, under transient disturbances. This algorithm is then tested on a Simulink/MatLab platform for various perturbations of load and fuel cell heat effluence. As a complementary tool to the aforementioned empirical plant, a nonlinear analytical model faithful to the existing process and instrumentation arrangement is evaluated and designed in the Simulink environment. This parallel task intends to serve as a building block to scalable hybrid configurations that might require a more detailed nonlinear representation for a wide variety of controller schemes and hardware implementations.
In the design of ocean wave energy converters, proper control design is essential to the maximization of the power generation performance for the device. However, in realistic applications, this control design must be undertaken in the presence of model uncertainty. This paper considers the use of robust control theory to optimize the nominal performance for a wave energy converter in stochastic waves, subject to the constraint that the controller be stability-robust to unstructured uncertainties. We formulate the problem as a multi-objective optimal control problem, in which the primary objective is the maximization of power generation for the nominal system, and the competing objective is the norm of the uncertainty input/output channel. This optimal control problem is nonconvex, and we therefore propose an iterative algorithm that can be used to arrive at a local optimal solution. This iterative approach employs the concept of Iterative Convex Overbounding, in the context of the classical Method of Centers. Here, the methodology is demonstrated on a model of a single, buoy- type wave energy converter.
We prove the missing uniqueness theorem for the viscosity solution of a quasi-variational inequality related to a minimax impulse control problem modeling the option pricing with proportional transactions costs. This result makes our robust control approach of option pricing in the interval market model essentially complete.
Low-temperature gasoline combustion (LTGC) engines can provide high efficiencies with very low NOx and particulate emissions. Despite these major advantages, methods for controlling LTGC combustion timing, achieving robust autoignition, and good low-load performance have challenged the development of practical LTGC engines. A key reason is that the ideal reactivity of the fuel varies with operating conditions, with low-reactivity fuels working well at high loads and higher-reactivity fuels working better at low loads. This article introduces a new technique called Additive Mixing Fuel Injection (AMFI) that adjusts the reactivity of the gasoline to obtain good performance over the operating map. Moreover, AMFI can provide robust combustion-timing control because it precisely meters very small amounts (0.01–0.6 mm 3 ) of an ignition-enhancing additive into the fuel each engine cycle. The additive used was 2-ethylhexyl nitrate (EHN), a common, inexpensive diesel-fuel ignition improver, but other additives could be used. Because additive amounts are so small, a 2-gal reservoir would be sufficient for medium-duty applications with refilling only at service intervals of about 8000 mi. The AMFI system has been installed on a single-cylinder LTGC research engine and demonstrated to provide robust combustion-timing control over wide ranges of combustion phasing, fueling rate, intake boost, engine speed, and intake temperature. AMFI also increases the fuel’s reactivity sufficiently to greatly reduce or eliminate the need for charge heating, simplifying engine design and significantly increasing thermal efficiency and the maximum load at low-boost conditions. The nitrogen in the EHN produced a modest increase in NOx, but it was mitigated by lower intake temperatures, and NOx emissions remained very low. Finally, the additive increases the sensitivity of autoignition reactions to variations in the local fuel/air mixture within the charge. This allows the use of controlled fuel stratification for improved LTGC-engine performance, and its potential to improve low-load operation was demonstrated.
In a recent paper, we reported that the position and depth of the minima in the harmonic spectra of CO 2 molecules can be dramatically manipulated by a slight change of the degree of alignment, thus providing a convenient method of shaping attosecond pulses which could lead to the splitting of a typical single attosecond burst into two. Here, we demonstrate that harmonic minima can also be dramatically controlled by changing the pump-probe angles to shape attosecond pulses. In the meanwhile, since the pump-probe angle-dependent harmonic spectra are very sensitive to the degree of alignment, harmonic spectra can also be used to calibrate the alignment distribution of molecules. In this work we identify such robust control of harmonic generation is due to the optical property of CO 2 and the coherent harmonic emission from the oriented molecules. The photoionization transition dipoles (PITDs) of CO 2 exhibit deep minima that change rapidly with molecular orientations accompanied by large phase changes of π in PITDs, thus leading to strong interference when the dipoles are added up coherently.
Summary The problem of global robust stabilization is studied by both continuous‐time and sampled‐data output feedback for a family of nonminimum‐phase nonlinear systems with uncertainty. The uncertain nonlinear system considered in this paper has an interconnect structure consisting of a driving system and a possibly unstable zero dynamics with uncertainty, ie, the uncertain driven system. Under a linear growth condition on the uncertain zero dynamics and a Lipschitz condition on the driving system, we show that it is possible to globally robustly stabilize the family of uncertain nonminimum‐phase systems by a single continuous‐time or a sampled‐data output feedback controller. The sampled‐data output feedback controller is designed by using the emulated versions of a continuous‐time observer and a state feedback controller, ie, by holding the input/output signals constant over each sampling interval. The design of either continuous‐time or sampled‐data output compensator uses only the information of the nominal system of the uncertain controlled plant. In the case of sampled‐data control, global robust stability of the hybrid closed‐loop system with uncertainty is established by means of a feedback domination method together with the robustness of the nominal closed‐loop system if the sampling time is small enough.
Critical infrastructures such as cyber-physical energy systems (CPS-E) integrate information flow and physical operations that are vulnerable to natural and targeted failures. Safe, secure, and reliable operation and control of CPS-E is critical to ensure societal well-being and economic prosperity. Automated control is key for real-time operations and may be mathematically cast as a sequential decision-making problem under uncertainty. Emergence of data-driven techniques for decision making under uncertainty, such as reinforcement learning (RL), have led to promising advances for addressing sequential decision-making problems for risk-based robust CPS-E control. However, existing research challenges include understanding the applicability of RL methods across diverse CPS-E applications, addressing the effect of risk preferences across multiple RL methods, and development of open-source domain-aware simulation environments for RL experimentation within a CPS-E context. This article systematically analyzes the applicability of four types of RL methods (model-free, model-based, hybrid model-free and model-based, and hierarchical) for risk-based robust CPS-E control. Problem features and solution stability for the RL methods are also discussed. We demonstrate and compare the performance of multiple RL methods under different risk specifications (risk-averse, risk-neutral, and risk-seeking) through the development and application of an open-source simulation environment. Motivating numerical simulation examples include representative single-zone and multizone building control use cases. Finally, six key insights for future research and broader adoption of RL methods are identified, with specific emphasis on problem features, algorithmic explainability, and solution stability.
Cyber-physical systems (CPSs) consist of computing and communication devices integrated with physical components such as sensors and actuators. Increasing connectivity to the Internet for remote monitoring and control has made CPSs more vulnerable to deliberate attacks, which are distinctly different from random perturbations in the system. This provides a way for purely cyber attacks to have physical consequences. Stuxnet is a prominent example of such an attack, one in which the malware acted over an extended period of time while deliberately remaining undetected. Such attacks can be described as Advanced Persistent Threats (APTs) -- long-term, stealthy attacks. Here, we extend our previous work on hypergames to develop defender strategies that are robust to deception and do not rely on attack detection. We prove that the defender can bound the attacker payoff with these strategies even when the attacker can choose between different attack modes, and we numerically demonstrate our approach on a realistic building control system. Finally, we discuss next steps in extending this approach towards an operational capability.
Not Available
Modern safety-critical energy infrastructures are increasingly operated in a hierarchical and modular control framework which allows for limited data exchange between the modules. In this context, it is important for each module to synthesize and communicate constraints on the values of exchanged information in order to assure system-wide safety. To ensure transient safety in inverter-based microgrids, we develop a set invariance-based distributed safety verification algorithm for each inverter module. Applying Nagumo's invariance condition, we construct a robust polynomial optimization problem to jointly search for safety-admissible set of control set-points and design parameters, under allowable disturbances from neighbors. We use sum-of-squares (SOS) programming to solve the verification problem and we perform numerical simulations using grid-forming inverters to illustrate the algorithm.
Short-term forecasting is frequently identified as an important tool for the effective management of wind generation. However, forecasting errors, inherent to the point forecasts, increase requirements for energy storage and can affect optimal system operation. Probabilistic forecasts can help tackle this issue by providing a proper characterization of forecasting errors in the optimization process. This paper proposes a multivariate model of forecasting data for wind generation. Predictive uncertainty intervals of wind power can be obtained by sampling from the proposed model. The main goal is to use empirical data models without linear or Gaussian approximations of the distributional or temporal variations. The predictive modeling is utilized within a case study of an energy storage system. Finally, a modified robust convex programming is used to maintain the practical robustness and feasibility of the solution based on the sampled scenarios from the model.
Not provided.