Compression testing of ceramics

The techniques for determining the compressive strengths of the rapidly developing family of super-strong, but brittle, materials is considered. The uniaxial column compression test is discussed, taking into account the loading block size mismatch, the loading block compliance mismatch, the load transmitting surfaces, and the eccentricity of loading. A description of the uniaxial hollow cylinder compression test is also provided, giving attention to premature failure from compliance tube splitting, stresses from compliance mismatch of the loading block, and premature failure from local rotations. The ring compression test is considered along with the hollow cylinder biaxial compression test.

Sines, G.

Producing Zirconium Diboride Components with Complex, Near-Net Shape Geometries by Aqueous Room-Temperature Injection Molding

Room-temperature injection molding is proposed as a novel, low-cost and more energy efficient manufacturing process capable of forming complex-shaped zirconium diboride (ZrB2) parts. This innovative processing method utilized aqueous suspensions with high powder loading and a minimal amount (5 vol.) of water-soluble polyvinylpyrrolidone (PVP), which was used as a viscosity modifier. Rheological characterization was performed to evaluate the room-temperature flow properties of ZrB2-PVP suspensions. ZrB2 specimens were fabricated with high green body strength and were machinable prior to binder removal despite their low polymer content. After binder burnout and pressureless sintering, the bulk density and microstructure of specimens were characterized using Archimedes technique and scanning electron microscopy. X-Ray Diffraction was used to determine the phase compositions present in sintered specimens. Ultimate strength of sintered specimens will be determined using ASTM C1323-10 compressive C-ring test.

Near-Net Shape Forming

Device For Testing Compatibility Of An O-Ring

Fixture designed for use in exposing compressed elastomeric O-ring or other ring seal to test fluid. Made of metal or plastic, with threaded recess into which O-ring placed. Opposite threaded end is opening through which test fluid introduced and placed in contact with O-ring. After exposure, compression set and swell or shrinkage of ring measured. Fixture set to compress ring by selected amount, providing for reproducible compression.

Davis, Dennis D.

Double-O-Ring Plug For Leak Tests

Pressure plug features redundant O-ring bore seals and axial port opening laterally into space between O-rings to enable testing of seals. Axial passage in plug connected through radial passage to space between O-rings. Opening used to test O-rings, then sealed with smaller O-ring compressed by machine screw. Useful to seal test or cleanout holes normally kept closed in hydraulic actuators, pumps, and other pressurized systems.

Greene, James H.

Long-term compression effects on elastomeric O-ring behavior

This paper discusses the results of testing performed on elastomeric seal materials that had been under compression for extended periods of time. Elastomeric seals used in the Space Shuttle redesigned solid rocket motors can experience compression times of up to six months. These seals must be capable of sealing internal motor pressure upon ignition. The tests described herein were performed in order to verify that the seals, which had experienced long-term compression could seal throughout motor operation. Testing was divided into two phases: (1) dynamic high pressure testing, and (2) resiliency testing. Dynamic testing was performed using specialized test fixtures that allowed simulation of the field joint movements during initial motor operation along with high pressure gas. Resiliency testing was performed using specialized test fixtures that also simulated field joint movements and also had the ability to measure the sealing force of the O-ring. Results from all testing indicated that the current elastomeric seals used in the redesigned solid rocket motors will seal during motor operations in the currently defined launch environments.

Clinton, R. G.

Design detail verification tests for a lightly loaded open-corrugation graphite-epoxy cylinder

Flat corrugated graphite-epoxy panels were tested in compression to verify selected design details of a ring-stiffened cylinder that was designed to support an axial compressive load of 157.6 kN/m without buckling. Three different sizes of subcomponent panels, with the same basic corrugation geometry, were tested: (1) 60.96-cm-long by 45.72-cm-wide panels to evaluate the local buckling strength of the shell wall design; (2) 91.44-cm-long by 45.72-cm-wide panels to evaluate a longitudinal joint and the load-introduction method; and (3) 254.0-cm-long by 91.44-cm-wide panels with four simulated-ring stiffeners to evaluate the ring-attachment method. The test results indicate that the modified shell-wall design, the longitudinal joint, the load-introduction method, and the stiffener-attachment method for the proposed cylinder have adequate strength to support the design load.

Davis, R. C.

Experimental Comparison of Piezoelectric and Magnetostrictive Shunt Dampers

A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (piezoceramic) and PMN-30PT (single crystal) stacks, as well as a Tb_0.3 Dy_0.7 Fe_1.92 (Terfenol-D) rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

energy conversion

Experimental Comparison of Piezoelectric and Magnetostrictive Shunt Dampers

A novel mechanism called the vibration ring is being developed to enable energy conversion elements to be incorporated into the driveline of a helicopter or other rotating machines. Unwanted vibration is transduced into electrical energy, which provides a damping effect on the driveline. The generated electrical energy may also be used to power other devices (e.g., health monitoring sensors). PZT (piezoceramic) and PMN-30%PT (single crystal) stacks, as well as a Tb_0.3 Dy_0.7 Fe_1.92 (Terfenol-D) rod with a bias magnet array and a pickup coil, were tested as alternative energy conversion elements to use within the vibration ring. They were tuned for broadband damping using shunt resistors, and dynamic compression testing was conducted in a high-speed load frame. Energy conversion was experimentally optimized at 750Hz by tuning the applied bias stress and resistance values. Dynamic testing was conducted up to 1000Hz to determine the effective compressive modulus, shunt loss factor, internal loss factor, and total loss factor. Some of the trends of modulus and internal loss factor versus frequency were unexplained. The single crystal device exhibited the greatest shunt loss factor whereas the Terfenol-D device had the highest internal and total loss factors. Simulations revealed that internal losses in the Terfenol-D device were elevated by eddy current effects, and an improved magnetic circuit could enhance its shunt damping capabilities. Alternatively, the Terfenol-D device may be simplified to utilize only the eddy current dissipation mechanism (no pickup coil or shunt) to create broadband damping.

piezoelectric

O-Ring-Testing Fixture

Fixture tests O-rings for sealing ability under dynamic conditions after extended periods of compression. Hydraulic cylinder moves plug in housing. Taper of 15 degrees on plug and cavity of housing ensures that gap created between O-ring under test and wall of cavity. Secondary O-rings above and below test ring maintain pressure applied to test ring. Evaluates effects of variety of parameters, including temperature, pressure, rate of pressurization, rate and magnitude of radial gap movement, and pretest compression time.

Turner, James E.

Impact tests on rubber compression springs for airplane landing gears

The present report gives the results of tests which were made for the purpose of solving the problem of whether diagrams obtained from pressure tests could be conclusive for the determination of the safe impact coefficients. It is first established that the rubber rings adhere firmly to the compression surfaces during deformation. Suggestions are thus obtained for a constructive simplification of the rubber rings. The hysteresis phenomenon is ascribed to external and internal friction forces. A device for falling tests is then described with which the process of shock absorption with rubber rings was tested.

Hohenemser, K

Stresses in and General Instability of Monocoque Cylinders with Cutouts I : Experimental Investigation of Cylinders with a Symmetric Cutout Subjected to Pure Bending

Ten 24S-T alclad cylinders of 20-inch diameter, 45- or 58-inch length, and 0.012-inch wall thickness, reinforced with 24S-T aluminum alloy stringers and rings were tested in pure bending. In the middle of the compression side of the cylinders there was a cutout extending over 19 inches in the longitudinal direction, and over an angle of 45 degrees, 90 degrees, or 135 degrees in the circumferential direction. The strain in the stringers and in the sheet covering was measured with metal electric strain gages. The stress distribution in the cylinders deviate considerably from the linear law valid for cylinders without a cutout. The maximum strain measured was about four-thirds of the value calculated from the Mc/I formula when I was taken as the moment of inertia of the cross section of the portion of the cylinder where the cutout was situated. A diagram is presented containing the strain factors defined as the ratios of measured strain to strain calculated with the Mc/I formula. All the 10 cylinders tested failed in general instability. Two symmetric and one antisymmetric pattern of buckling were observed and the buckling load appeared to be independent of the method of manufacture and the length of the cylinder. The buckling load of the cylinders having cutouts extending over 45 degrees, 90 degrees, and 135 degrees was 66, 47, and 31 percent, respectively, of the buckling load of the cylinder without a cutout.

CYLINDERS, MONOCOQUE-BUCKLING

Silicon Nitride Creep Under Various Specimen-Loading Configurations

Extensive creep testing of a hot-pressed silicon nitride (NC 132) was performed at 1300 C in air using five different specimen-loading configurations: (1) pure tension, (2) pure compression, (3) four-point uniaxial flexure, (4) ball-on-ring biaxial flexure, and (5) ring-on-ring biaxial flexure. This paper reports experimental results as well as test techniques developed in this work. Nominal creep strain and its rate for a given nominal applied stress were greatest in tension, least in compression, and intermediate in uniaxial and biaxial flexure. Except for the case of compression loading, nominal creep strain generally decreased with time, resulting in a less-defined steady-state condition. Of the four creep formulations-power-law, hyperbolic sine, step, and redistribution--the conventional power-law formulation still provides the most convenient and reasonable estimation of the creep parameters of the NC 132 material. The data base to be obtained will be used to validate the NASA Glenn-developed design code CARES/Creep (ceramics analysis and reliability evaluation of structures and creep).

Choi, Sung R.

Experimental Investigation of a Graphite-Composite Intertank Section for a Reusable Launch Vehicle

The use of graphite-composites as primary structure is essential for the development of a cost effective single-stage-to-orbit reusable launch vehicle (RLV). A full-scale segment of a graphite-composite intertank was designed and fabricated by an industry team and tested at NASA Langley Research Center as a part of the RLV technology development program. The intertank test component was approximately 3.0 m long by 6.7 m wide and included slightly less than a 90deg section of a cylindrical intertank. The test article was fabricated using graphite-bismaelimide composite material and consisted of a hat-stiffened skin with five ring frames. The stiffeners were secondarily bonded to the panel skin and the ring frames were mechanically attached. The test article was loaded to failure with a uniform compression load applied by 21 individually controlled hydraulic actuators. Resistance strain gages, linear variable differential transformers and video cameras were used to measure and record the test results. A linear f d t e element analysis of the test article and test fixture was performed. The test results verified the structural integrity cf the intertank test article up to the design limit load. However, the test article failed in general skin buckling between the ring frames at a load 1.08 times design limit load. This load was considerably lower than the expected failure load. The cause of premature failure is being investigated. Good correlation of the test and analysis results was obtained for loads up to the design limit load.

Sawyer, James Wayne

Development of Advanced In-Cylinder Components and Tribological Systems for Low Heat Rejection Diesel Engines

In-cylinder components and tribological system concepts were designed, fabricated and tested at conditions anticipated for a 55% thermal efficiency heavy duty diesel engine for the year 2000 and beyond. A Cummins L10 single cylinder research engine was used to evaluate a spherical joint piston and connecting rod with 19.3 MPa (2800 psi) peak cylinder pressure capability, a thermal fatigue resistant insulated cylinder head, radial combustion seal cylinder liners, a highly compliant steel top compression ring, a variable geometry turbocharger, and a microwave heated particulate trap. Components successfully demonstrated in the final test included spherical joint connecting rod with a fiber reinforced piston, high conformability steel top rings with wear resistant coatings, ceramic exhaust ports with strategic oil cooling and radial combustion seal cylinder liner with cooling jacket transfer fins. A Cummins 6B diesel was used to develop the analytical methods, materials, manufacturing technology and engine components for lighter weight diesel engines without sacrificing performance or durability. A 6B diesel engine was built and tested to calibrate analytical models for the aluminum cylinder head and aluminum block.

Yonushonis, T. M.

Nitrile/Buna N Material Failure Assessment for an O-Ring used on the Gaseous Hydrogen Flow Control Valve (FCV) of the Space Shuttle Main Engine

After the rollout of Space Shuttle Discovery in April 2005 in preparation for return-to-flight, there was a failure of the Orbiter (OV-103) helium signature leak test in the gaseous hydrogen (GH2) system. Leakage was attributed to the Flow Control Valve (FCV) in Main Engine 3. The FCV determined to be the source of the leak for OV-103 is designated as LV-58. The nitrile/Buna N rubber O-ring seal was removed from LV-58, and failure analysis indicated radial cracks providing leak paths in one quadrant. Cracks were eventually found in 6 of 9 FCV O-rings among the three Shuttle Orbiters, though none were as severe as those for LV-58, OV-103. Testing by EM10 at MSFC on all 9 FCV O- rings included: laser dimensional, Shore A hardness and properties from a dynamic mechanical analyzer (DMA) and an Instron tensile machine. The following test data was obtained on the cracked quadrant of the LV-58, OV-103 O-ring: (1) the estimated compression set was only 9.5%, compared to none for the rest of the O-ring; (2) Shore A hardness for the O.D. was higher by almost 4 durometer points than for the rest of the O-ring; and (3) DMA data showed that the storage/elastic modulus E was almost 25% lower than for the rest of the O-ring. Of the 8 FCV O-rings tested on an Instron, 4 yielded tensile strengths that were below the MIL spec requirement of 1350 psi-a likely influence of rubber cracking. Comparisons were made between values of modulus determined by DNA (elastic) and Instron (Young s). Each nitrile/Buna N O-ring used in the FCV conforms to the MIL-P-25732C specification. A number of such O-rings taken from shelf storage at MSFC and Kennedy Space Center (KSC) were used to generate a reference curve of DMA glass transition temperature (Tg) vs. shelf storage time ranging from 8 to 26 years. A similar reference curve of TGA onset temperature (of rubber weight loss) vs. shelf storage time was also generated. The DMA and TGA data for the used FCV O-rings were compared to the reference curves. Correlations were also made between the DMA modulus (at 22 C) and Shore A hardness for all 9 of the FCV O-rings used among the three Shuttle Orbiters. The radial cracking in the FCV O-rings was determined to be due to ozone attack, as nitrile/Buna N rubber is susceptible to such attack. Nitrile/Buna N material under MIL-P25732C should be used in a hydraulic fluid environment to help protect it from cracking. However, the FCV O-rings were used in an air only environment. The FCV design has as much as a 9-mil gap that allows the O.D. of the O-ring to be directly exposed to ozone, pressurized air and some elevated temperatures, accelerating the weathering process that leads to O-ring cracking. Space Shuttle flights will likely not continue past 2010. Therefore, Shuttle management decided to continue using the nitrile/Buna N material for the FCVs, but have each O-ring replaced after 3 years to minimize any chances for crack initiation.

Wingard, Doug

Buckling tests of a 10 foot diameter stiffened cylinder with rectangular cutouts

A 10-foot diameter aluminum cylinder with rectangular cutouts in its ring and stringer stiffened wall was loaded to failure by an end bending moment. A 24x27 inch cutout, centered on the compression side of the shell, was first cut into the cylinder. After testing, the cutout area was enlarged to a 36/36 inch square cutout that removed the material damaged by buckling during the first test. After the second buckling test, the cutout area was patched with an equivalent stiffness plate bolted over the cutout hole. The cylinder was rotated 120 deg. and a 18x18 inch square hole cut into the center of the new compression side of the shell. Test specimen details, test procedures, and test results are presented.

Davis, Randall C.

Method for compression testing of composite materials at high strain rates

A method is presented for testing composite materials in compression at strain rates up to approximately 500 per s. The method uses a thin ring specimen (4 in. in diameter, 1 in. wide, six-eight plies thick) loaded dynamically by an external pressure pulse applied explosively through a liquid. Strains in the specimen and in a steel calibration ring are recoorded with a digital processing oscilloscope. Results are plotted by an x-y plotter in the form of a dynamic stress-strain curve. Data analysis is based on a numerical solution of the equation of motion. A computer program is used which involves smoothing and approximation of the strain magnitude, strain rate, and strain acceleration. Dynamic stress-strain curves obtained for 0-deg and 90-deg specimens of two graphite/epoxy composites are presented.

Daniel, I. M.

Testing of molded high temperature plastic actuator road seals for use in advanced aircraft hydraulic systems

Molded high temperature plastic first and second stage rod seal elements were evaluated in seal assemblies to determine performance characteristics. These characteristics were compared with the performance of machined seal elements. The 6.35 cm second stage Chevron seal assembly was tested using molded Chevrons fabricated from five molding materials. Impulse screening tests conducted over a range of 311 K to 478 K revealed thermal setting deficiencies in the aromatic polyimide molding materials. Seal elements fabricated from aromatic copolyester materials structurally failed during impulse cycle calibration. Endurance testing of 3.85 million cycles at 450 K using MIL-H-83283 fluid showed poorer seal performance with the unfilled aromatic polyimide material than had been attained with seals machined from Vespel SP-21 material. The 6.35 cm first stage step-cut compression loaded seal ring fabricated from copolyester injection molding material failed structurally during impulse cycle calibration. Molding of complex shape rod seals was shown to be a potentially controllable technique, but additional molding material property testing is recommended.

Waterman, A. W.